test report

FCC ID: 2APPZ-I33V

Test Report

Download: PDF
FCCID_4380943

                            CTC Laboratories, Inc.
2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District,
Shenzhen, Guangdong, China
Tel: +86-755-27521059 Fax: +86-755-27521011 Http://www.sz-ctc.com.cn


                                                    TEST REPORT
 Report No. ...................................... :      GTI20191250E-2

 FCC ID……………………………...…:                                   2APPZ-I33V

 Applicant......................................... :     Fanvil Technology Co., LTD.
                                                          4F, Block A, Bldg#1, GaoXinQi Hi-TechPark Phase-II, 67th District,
 Address…………………..………..….:
                                                          Bao'An, Shenzhen, China
 Manufacturer....................................:        Fanvil Technology Co., LTD.
                                                          4F, Block A, Bldg#1, GaoXinQi Hi-TechPark Phase-II, 67th District,
 Address............................................:
                                                          Bao'An, Shenzhen, China
 Product Name ................................ :          IP Door Phone

 Trade Mark....................................... :      Fanvil

 Model/Type reference ...................... :            i33V

 Listed Model(s) ................................ :       i33VF

 Standard ....................................... :       FCC CFR Title 47 Part 15 Subpart C

 Date of receipt of test sample……:                        Jul. 04, 2019

 Date of testing……………………..:                               Jul. 05, 2019 ~ Jul. 22, 2019

 Date of issue……………………....:                               Jul. 22, 2019

 Result………………………………:                                      PASS

 Compiled by:
 (Printed name + signature)                               Terry Su

 Supervised by:
 ( Printed name + signature)                              Eric Zhang

 Approved by:
 ( Printed name + signature)                              Walter Chen


 Testing Laboratory Name.............. :                  CTC Laboratories, Inc.

 Address ............................................ :   2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan
                                                          High-Tech Park, Longhua District, Shenzhen, Guangdong, China
 This test report may be duplicated completely for legal use with the approval of the applicant. It should not be
 reproduced except in full, without the written approval of our laboratory. The client should not use it to claim
 product endorsement by CTC. The test results in the report only apply to the tested sample. The test report
 shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be
 raised to CTC within 15 days since the date when the report is received. It will not be taken into consideration
 beyond this limit. The test report merely correspond to the test sample.


                                                                           Page 2 of 29                                           Report No.: GTI20191250E-2



                                                                       Table of Contents                                                                                      Page
1.     TEST SUMMARY.................................................................................................................................................... 3
     1.1.     TEST STANDARDS.......................................................................................................................................................... 3
     1.2.     REPORT VERSION .......................................................................................................................................................... 3
     1.3.     TEST DESCRIPTION ........................................................................................................................................................ 4
     1.4.     TEST FACILITY .............................................................................................................................................................. 5
     1.5.     MEASUREMENT UNCERTAINTY ........................................................................................................................................ 5
     1.6.     ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 6
     1.7.     EUT OPERATION STATE.................................................................................................................................................. 6
1.     GENERAL INFORMATION....................................................................................................................................... 7
     1.1.     CLIENT INFORMATION ................................................................................................................................................... 7
     1.2.     GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 7
     1.3.     ACCESSORY EQUIPMENT INFORMATION ............................................................................................................................ 7
     1.4.     MEASUREMENT INSTRUMENTS LIST ................................................................................................................................. 8
2.     TEST ITEM AND RESULTS ..................................................................................................................................... 10
     2.1.     CONDUCTED EMISSION ................................................................................................................................................ 10
     2.2.     RADIATED EMISSION ................................................................................................................................................... 13
     2.3.     OCCUPIED BANDWIDTH 20 DB BANDWIDTH .................................................................................................................... 21
     2.4.     FIELD STRENGTH OF THE FUNDAMENTAL ......................................................................................................................... 23
     2.5.     ANTENNA REQUIREMENT ............................................................................................................................................. 26
3.     LABEL AND LABEL LOCATION .............................................................................................................................. 27
4.     EUT TEST PHOTOS ............................................................................................................................................... 28
3.     PHOTOGRAPHS OF EUT CONSTRUCTIONAL ......................................................................................................... 29




                                                                CTC Laboratories, Inc.
      2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                                Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                             For anti-fake verification, please visit the official website of Certification and
                                                             Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                           Page 3 of 29                           Report No.: GTI20191250E-2



 1. TEST SUMMARY
 1.1. Test Standards
The tests were performed according to following standards:
FCC Rules Part 15C: Intentional Radiators
ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices.


 1.2. Report version
        Revised No.                        Date of issue                                           Description
              01                           Jul. 22, 2019                                             Original




                                                              CTC Laboratories, Inc.
    2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                              Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                           For anti-fake verification, please visit the official website of Certification and
                                                           Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                           Page 4 of 29                           Report No.: GTI20191250E-2



1.3. Test Description
                                                      FCC Part 15 Subpart C

                       Test Item                                   Standard Section                   Result          Test Engineer

                Conducted Emission                                        15.207                       Pass                Terry Su
                Radiated Emissions                                        15.209                       Pass                Terry Su
       Field Strength of the Fundamental                                  15.209                       Pass                Terry Su
 Occupied Bandwidth and 20dB Bandwidth                                    15.215                       Pass                Terry Su
               Antenna requirement                                        15.203                       Pass                Terry Su

Note: N/A: Not applicable.
     The measurement uncertainty is not included in the test result.




                                                              CTC Laboratories, Inc.
    2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                              Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                           For anti-fake verification, please visit the official website of Certification and
                                                           Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                           Page 5 of 29                           Report No.: GTI20191250E-2



1.4. Test Facility
Address of the report laboratory

CTC Laboratories, Inc.
Add: 2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District,
Shenzhen, Guangdong, China

Laboratory accreditation

The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L5365
CTC Laboratories, Inc. has been assessed and proved to be in compliance with CNAS-CL01 Accreditation
Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025: 2005 General Requirements)
for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No.: CN1208
CTC Laboratories, Inc. EMC Laboratory has been accredited by A2LA for technical competence in the field of
electrical testing, and proved to be in compliance with ISO/IEC 17025: 2005 General Requirements for the
Competence of Testing and Calibration Laboratories and any additional program requirements in the identified
field of testing.


IC Registration No.: 9783A-1
The 3m alternate test site of CTC Laboratories, Inc. EMC Laboratory has been registered by Certification and
Engineer Bureau of Industry Canada for the performance of with Registration NO.: 9783A-1 on Jan, 2016.


FCC-Registration No.: 951311
CTC Laboratories, Inc. EMC Laboratory has been registered and fully described in a report filed with the (FCC)
Federal Communications Commission. The acceptance letter from the FCC is maintained in our files.
Registration 951311, Aug 26, 2017



 1.5. Measurement Uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there may
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to TR-100028-01” Electromagnetic compatibility and
Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio equipment characteristics; Part
1” and TR-100028-02 “Electromagnetic compatibility and Radio spectrum Matters (ERM);Uncertainties in the
measurement of mobile radio equipment characteristics; Part 2 “ and is documented in the CTC Laboratories, Inc.
quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar
to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.

Below is the best measurement capability for CTC Laboratories, Inc.




                                                              CTC Laboratories, Inc.
    2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                              Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                           For anti-fake verification, please visit the official website of Certification and
                                                           Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                           Page 6 of 29                           Report No.: GTI20191250E-2



                          Test Items                                         Measurement Uncertainty                          Notes
Transmitter power conducted                                                               0.42 dB                               (1)
Transmitter power Radiated                                                                2.14 dB                               (1)
Conducted spurious emissions 9kHz~40GHz                                                   1.60 dB                               (1)
Radiated spurious emissions 9kHz~40GHz                                                    2.20 dB                               (1)
Conducted Emissions 9kHz~30MHz                                                            3.20 dB                               (1)
Radiated Emissions 30~1000MHz                                                             4.70 dB                               (1)
Radiated Emissions 1~18GHz                                                                5.00 dB                               (1)
Radiated Emissions 18~40GHz                                                               5.54 dB                               (1)
Occupied Bandwidth                                                                         ---------                            (1)
Note (1): This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=1.96.



  1.6. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                                          15~35°C
Relative Humidity:                                                    30~60 %
Air Pressure:                                                         950~1050kPa


  1.7. EUT Operation state
The EUT has been tested under typical operating condition. The Applicant provides software to control the EUT
for staying in continuous transmitting mode for testing.




                                                              CTC Laboratories, Inc.
    2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                              Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                           For anti-fake verification, please visit the official website of Certification and
                                                           Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                              Page 7 of 29                           Report No.: GTI20191250E-2


1. GENERAL INFORMATION
1.1. Client Information
    Applicant:                                  Fanvil Technology Co., LTD.
                                                4F, Block A, Bldg#1, GaoXinQi Hi-TechPark Phase-II, 67th District,
    Address:
                                                Bao'An, Shenzhen, China
    Manufacturer:                               Fanvil Technology Co., LTD.
                                                4F, Block A, Bldg#1, GaoXinQi Hi-TechPark Phase-II, 67th District,
    Address:
                                                Bao'An, Shenzhen, China



    1.2. General Description of EUT
    Product Name:                                 IP Door Phone
    Model/Type reference:                         Fanvil
    Marketing Name:                               i33V
    Listed Model(s):                              i33VF
                                                  All these models are identical in the same PCB, layout and electrical
    Model Difference:
                                                  circuit, the only difference is way to install.
    Power supply:                                 12Vdc/1A from External Adapter
                                                  Supplied from POE
    Hardware version:                             N/A
    Software version:                             N/A

    RF Parameter
    Operation frequency:                          125KHz
    Antenna type:                                 Loop Antenna


    1.3. Accessory Equipment information
Equipment Information
Name                           Model                                    S/N                                    Manufacturer
AC/DC Adapter                  LPL-V0121201100AT                        ---                                    Sagemcom
Cable Information
Name                           Shielded Type                            Ferrite Core                           Length
/                              /                                        /                                      /




                                                                 CTC Laboratories, Inc.
       2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                                 Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                              For anti-fake verification, please visit the official website of Certification and
                                                              Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                             Page 8 of 29                           Report No.: GTI20191250E-2


1.4. Measurement Instruments List
Tonscend JS0806-2 Test system

Item           Test Equipment                 Manufacturer               Model No.               Serial No.               Calibrated until

 1           Spectrum Analyzer             Rohde & Schwarz                 FSU26                   100105                  Dec. 27, 2019

 2           Spectrum Analyzer             Rohde & Schwarz               FUV40-N                   101331                  Dec. 27, 2019
             MXG Vector Signal
 3                                                Agilent                 N5182A               MY47420864                  Dec. 27, 2019
                Generator
 4            Signal Generator                    Agilent                 E8257D               MY46521908                  Dec. 27, 2019

 5              Power Sensor                      Agilent                U2021XA                MY5365004                  Dec. 27, 2019

 6              Power Sensor                      Agilent                U2021XA                MY5365006                  Dec. 27, 2019
               Simultaneous
 7                                                Agilent                 U2531A               TW54493510                  Dec. 27, 2019
               Sampling DAQ
 8            Climate Chamber                      TABAI                   PR-4G                 A8708055                  Dec. 27, 2019
            Wideband Radio
 9                                         Rohde & Schwarz               CMW500                    116410                  Dec. 27, 2019
          Communication Tester
 10           Climate Chamber                     ESPEC                   MT3065                       /                   Dec. 27, 2019
             300328 v2.1.1 test
 11                                            TONSCEND                      v2.6                      /                           /
                  system

Item          Test Equipment                 Manufacturer                Model No.                Serial No.              Calibrated until

 1          EMI Test Receiver             Rohde & Schwarz                   ESCI                    100658                 Dec. 27, 2019

 2             High pass filter              micro-tranics              HPM50111                      142                  Dec. 27, 2019

 3          Log-Bicon Antenna                Schwarzbeck                CBL6141A                     4180                  Dec. 27, 2019
               Ultra-Broadband
 4                                           SchwarzBeck                BBHA9170                     25841                 Dec. 27, 2019
                   Antenna
 5              Loop Antenna                     LAPLAC                    RF300                     9138                  Dec. 27, 2019

 6              Loop Antenna                        ETS                     6507                      146                  Aug. 26, 2019

 7          Spectrum Analyzer             Rohde & Schwarz                  FSU26                    100105                 Dec. 27, 2019

 8             Horn Antenna                  Schwarzbeck               BBHA 9120D                     647                  Dec. 27, 2019

 9              Pre-Amplifier                       HP                     8447D                1937A03050                 Dec. 27, 2019

 10             Pre-Amplifier                     EMCI                 EMC051835                    980075                 Dec. 27, 2019

 11            Antenna Mast                         UC                    UC3000                      N/A                        N/A

 12              Turn Table                         UC                    UC3000                      N/A                        N/A

 13         Cable Below 1GHz                 Schwarzbeck                 AK9515E                    33155                  Dec. 27, 2019

 14         Cable Above 1GHz                 Hubersuhner             SUCOFLEX102                   DA1580                  Dec. 27, 2019

 15                 Splitter                  Mini-Circuit                ZAPD-4                    400059                 Dec. 27, 2019

 16       RF Connection Cable             HUBER+SUHNER                    RE-7-FL                     N/A                  Dec. 27, 2019
                                              Chengdu
 17       RF Connection Cable                                                 ---                      ---                 Dec. 27, 2019
                                            E-Microwave
                                             Compliance
 18            High pass filter                                            BSU-6                     34202                 Dec. 27, 2019
                                          Direction systems

                                                                CTC Laboratories, Inc.
      2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                                Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                             For anti-fake verification, please visit the official website of Certification and
                                                             Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


sork ng   n merevere n qg n werbwe   on eor d nc nnnernnare en nos neren nenennn n n nere snn nuns nn nemnn rnenn n n rear n   n neten n n enr nne movn n nnarnaren nn ner n nar se un n narn ncb nar n n en neeen nnn en n en ne n n n nn




apccrsyptcree
                                             rvie qy rvv e vegvis                             roene qxeve sez d van r w a a                      va uen ie se vevvze en up en t


                                                                                             2o rer wn nernen i enb e bevra eb rra e sn sba db un seb en e eperee w n nepetme ie n uen in n n eapne gec s en e el en


                                                            Page 10 of 29                            Report No.: GTI20191250E-2



2. TEST ITEM AND RESULTS
 2.1. Conducted Emission
Limit

FCC CFR Title 47 Part 15 Subpart C Section 15.207/ RSS-Gen 7.2:
                                                                                          Limit (dBuV)
            Frequency range (MHz)
                                                                      Quasi-peak                                   Average
                      0.15-0.5                                          66 to 56*                                  56 to 46*
                        0.5-5                                               56                                         46
                         5-30                                               60                                         50
Notes:
(1) *Decreasing linearly with logarithm of the frequency.
(2) The lower limit shall apply at the transition frequencies.
(3) The limit decrease in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.


Test Configuration




Test Procedure

1.      The EUT was setup according to ANSI C63.10:2013 requirements.
2.      The EUT was placed on a platform of nominal size, 1 m by 1.5 m, raised 80 cm above the conducting
        ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces of
        EUT were at least 80 cm from any other grounded conducting surface.
3.      The EUT and simulators are connected to the main power through a line impedances stabilization network
        (LISN). The LISN provides a 50ohm /50uH coupling impedance for the measuring equipment.
         The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
         diagram of the test setup and photographs)
4.      Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor, was
        individually connected through a LISN to the input power source.
5.      The excess length of the power cord between the EUT and the LISN receptacle were folded back and forth
        at the center of the lead to form a bundle not exceeding 40 cm in length.
6.      Conducted Emissions were investigated over the frequency range from 0.15MHz to 30MHz using a receiver
        bandwidth of 9 kHz.
7.      During the above scans, the emissions were maximized by cable manipulation.


                                                               CTC Laboratories, Inc.
     2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                               Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                            For anti-fake verification, please visit the official website of Certification and
                                                            Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                           Page 11 of 29                           Report No.: GTI20191250E-2



Test Mode:
     Please refer to the clause 1.7.

Test Results
          Test Voltage:            AC 120V/60 Hz
          Terminal:                Line




          Emission Level= Read Level+ Correct Factor




                                                              CTC Laboratories, Inc.
    2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                              Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                           For anti-fake verification, please visit the official website of Certification and
                                                           Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                       Page 12 of 29                            Report No.: GTI20191250E-2



      Test Voltage:            AC 120V/60 Hz
      Terminal:                Neutral




      Emission Level= Read Level+ Correct Factor




                                                          CTC Laboratories, Inc.
2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                          Page 13 of 29                            Report No.: GTI20191250E-2


 2.2. Radiated Emission
FCC Limit

                                       Radiated Emission Limits (9 kHz~1000 MHz)

                    Frequency                                  Field Strength                        Measurement Distance
                      (MHz)                                   (microvolt/meter)                            (meters)

                   0.009~0.490                                   2400/F(KHz)                                     300

                   0.490~1.705                                  24000/F(KHz)                                        30

                    1.705~30.0                                         30                                           30

                       30~88                                          100                                           3

                      88~216                                          150                                           3

                     216~960                                          200                                           3

                    Above 960                                         500                                           3


                                        Radiated Emission Limit (Above 1000MHz)

                       Frequency                                             Distance Meters(at 3m)
                         (MHz)                                        Peak                                 Average

                      Above 1000                                        74                                     54

    Note:
    (1) The tighter limit applies at the band edges.
    (2) Emission Level (dBuV/m)=20log Emission Level (uV/m).

Test Configuration




                                                     Below 30MHz Test Setup




                                                             CTC Laboratories, Inc.
   2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                             Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                          For anti-fake verification, please visit the official website of Certification and
                                                          Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                            Page 14 of 29                            Report No.: GTI20191250E-2




                                                     Below 1000MHz Test Setup




                                                        Above 1GHz Test Setup

Test Procedure

1.    The EUT was setup and tested according to ANSI C63.10:2013
2.    The EUT is placed on a turn table which is 0.8 meter above ground for below 1 GHz, and 1.5 m for above 1
      GHz. The turn table is rotated 360 degrees to determine the position of the maximum emission level.
3.    The EUT was set 3 meters from the receiving antenna, which was mounted on the top of a variable height
      antenna tower.
4.    For each suspected emission, the EUT was arranged to its worst case and then tune the Antenna tower
      (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp
      and a high pass filter are used for the test in order to get better signal level to comply with the guidelines.
5.    Set to the maximum power setting and enable the EUT transmit continuously.
6.    Use the following spectrum analyzer settings
      (1) Span shall wide enough to fully capture the emission being measured;
      (2) Below 1 GHz:
      RBW=120 kHz, VBW=300 kHz, Sweep=auto, Detector function=peak, Trace=max hold;
      If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit, the
      peak emission level will be reported. Otherwise, the emission measurement will be repeated using the
      quasi-peak detector and reported.
      (3) From 1 GHz to 10th harmonic:
      RBW=1MHz, VBW=3MHz Peak detector for Peak value.
      RBW=1MHz, VBW=3MHz RMS detector for Average value.

                                                               CTC Laboratories, Inc.
     2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                               Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                            For anti-fake verification, please visit the official website of Certification and
                                                            Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                          Page 15 of 29                            Report No.: GTI20191250E-2



Test Mode
    Please refer to the clause 1.7.


Test Result

9KHz~0.15MHz
         Ant. Pol.                  Horizontal




         Remarks:
         1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
         2.Margin value = Level -Limit value




                                                             CTC Laboratories, Inc.
   2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                             Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                          For anti-fake verification, please visit the official website of Certification and
                                                          Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                       Page 16 of 29                            Report No.: GTI20191250E-2



      Ant. Pol.                  Vertical




      Remarks:
      1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
      2.Margin value = Level -Limit value




                                                          CTC Laboratories, Inc.
2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                          Page 17 of 29                            Report No.: GTI20191250E-2



0.15MHz~30MHz
         Ant. Pol.                  Horizontal




         Remarks:
         1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
         2.Margin value = Level -Limit value




                                                             CTC Laboratories, Inc.
   2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                             Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                          For anti-fake verification, please visit the official website of Certification and
                                                          Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                       Page 18 of 29                            Report No.: GTI20191250E-2



      Ant. Pol.                  Vertical




      Remarks:
      1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
      2.Margin value = Level -Limit value




                                                          CTC Laboratories, Inc.
2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                         Page 19 of 29                            Report No.: GTI20191250E-2

30MHz-1GHz
        Ant. Pol.                  Horizontal




        Remarks:
        1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
        2.Margin value = Level -Limit value




                                                            CTC Laboratories, Inc.
  2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                            Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                         For anti-fake verification, please visit the official website of Certification and
                                                         Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                       Page 20 of 29                            Report No.: GTI20191250E-2



      Ant. Pol.                  Vertical




      Remarks:
      1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
      2.Margin value = Level -Limit value




                                                          CTC Laboratories, Inc.
2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                            Page 21 of 29                            Report No.: GTI20191250E-2



 2.3. Occupied Bandwidth 20 dB Bandwidth
Limit

FCC CFR Title 47 Part 15 Subpart C Section 15.215
Intentional radiators must be designed to ensure that the 20dB emission bandwidth in the specific band.

Test Configuration




Test Procedure

1.   The EUT was directly connected to the spectrum analyzer and antenna output port as show in the block
     diagram above.
2.   Spectrum Setting:
     (1) Set RBW ≥ 1% of the 20 dB bandwidth.
     (2) Set the video bandwidth (VBW) ≥ RBW.
     (3) Detector = Peak.
     (4) Trace mode = Max hold.
     (5) Sweep = Auto couple.

Test Mode
        Please refer to the clause 1.7.

Test Results




                                                               CTC Laboratories, Inc.
     2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                               Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                            For anti-fake verification, please visit the official website of Certification and
                                                            Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                       Page 22 of 29                            Report No.: GTI20191250E-2



   Channel                   Occupied Bandwidth                          20dB Bandwidth
                                                                                                                        Result
Frequency(kHz)                     (kHz)                                     (kHz)
       125                             6.686                                     7.757                                   PASS




                                                          CTC Laboratories, Inc.
2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                           Page 23 of 29                            Report No.: GTI20191250E-2



 2.4. Field Strength of the Fundamental
Limit

FCC CFR Title 47 Part 15 Subpart C Section 15.209
                                                 Limit for frequency below 30MHz:
                                                                        Measurement
                 Frequency                    Limit (uV/m)                                                   Remark
                                                                        Distance(m)
                0.009~0.490                   2400/F(kHz)                     300                          Quasi-peak

                0.490~1.705                  24000/F(kHz)                      30                          Quasi-peak

                 1.705~30.0                         30                         30                          Quasi-peak

Note: Limit dBuV/m @3m = Limit dBuV/m @300m + 40*log(300/3)= Limit dBuV/m @300m +80,
        Limit dBuV/m @3m = Limit dBuV/m @30m +40*log(30/3)= Limit dBuV/m @30m + 40.

Test Configuration




                                                          Below 30MHz Test Setup

Test Procedure

1. The EUT was setup and tested according to ANSI C63.10:2013 requirements.
2. The EUT is placed on a turn table which is 0.8 meter above ground. The turn table is rotated 360 degrees to
determine the position of the maximum emission level.
3. The EUT was positioned such that the distance from antenna to the EUT was 3 meters.
4. The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. This is repeated
for both horizontal and vertical polarization of the antenna. In order to find the maximum emission, all of the
interface cables were manipulated according to ANSI C63.10:2013 on radiated measurement.

Test Mode
Please refer to the clause 1.7.




                                                              CTC Laboratories, Inc.
    2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                              Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                           For anti-fake verification, please visit the official website of Certification and
                                                           Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                          Page 24 of 29                            Report No.: GTI20191250E-2



Test Result

         Ant. Pol.                  Horizontal




         Emission Level= Read Level+ Correct Factor




                                                             CTC Laboratories, Inc.
   2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                             Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                          For anti-fake verification, please visit the official website of Certification and
                                                          Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                       Page 25 of 29                            Report No.: GTI20191250E-2



      Ant. Pol.                  Vertical




      Emission Level= Read Level+ Correct Factor




                                                          CTC Laboratories, Inc.
2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                           Page 26 of 29                            Report No.: GTI20191250E-2



 2.5. Antenna requirement
Requirement

FCC CFR Title 47 Part 15 Subpart C Section 15.203:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible
party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a
unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be
replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.

Refer to statement below for compliance.
The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a standard
antenna jack or electrical connector is prohibited. Further, this requirement does not apply to intentional radiators
that must be professionally installed.
The directional gain of the antenna less than 6dBi, please refer to the EUT internal photographs antenna photo.




                                                              CTC Laboratories, Inc.
    2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Longhua District, Shenzhen, Guangdong, China
                              Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                           For anti-fake verification, please visit the official website of Certification and
                                                           Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn



Document Created: 2019-07-29 10:07:03
Document Modified: 2019-07-29 10:07:03

© 2024 FCC.report