DSS REPORT 2

FCC ID: 2APP6TM-15

Test Report

Download: PDF
FCCID_4400172

                                                                         Report No.: TCT190703E017
                                   and staying aimed at the emission source for
                                   receiving the maximum signal. The final
                                   measurement antenna elevation shall be that which
                                   maximizes the emissions. The measurement
                                   antenna elevation for maximum emissions shall be
                                   restricted to a range of heights of from 1 m to 4 m
                                   above the ground or reference ground plane.
                                3. Set to the maximum power setting and enable the
                                    EUT transmit continuously.
                                4. Use the following spectrum analyzer settings:
                                    (1) Span shall wide enough to fully capture the
                                        emission being measured;
                                    (2) Set RBW=120 kHz for f < 1 GHz, RBW=1MHz
                                        for f>1GHz ; VBW≥RBW;
                                          Sweep = auto; Detector function = peak; Trace
                                          = max hold for peak
                                     (3) For average measurement: use duty cycle
                                         correction factor method per
                                        15.35(c). Duty cycle = On time/100 milliseconds
                                        On time =N1*L1+N2*L2+...+Nn-1*LNn-1+Nn*Ln
                                          Where N1 is number of type 1 pulses, L1 is
                                          length of type 1 pulses, etc.
                                          Average Emission Level = Peak Emission
                                          Level + 20*log(Duty cycle)
                                         Corrected Reading: Antenna Factor + Cable
                                         Loss + Read Level - Preamp Factor = Level
Test results:                   PASS




                                                                                 Page 41 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                             Report No.: TCT190703E017

6.11.2.         Test Instruments

                                   Radiated Emission Test Site (966)
       Name of                                                                 Serial
                                Manufacturer               Model                              Calibration Due
      Equipment                                                               Number
                              ROHDE&SCHW
     Test Receiver                                         ESIB7               100197           Sep. 17, 2019
                                  ARZ
                              ROHDE&SCHW
 Spectrum Analyzer                                         FSQ40               200061           Sep. 20, 2019
                                  ARZ
                               EM Electronics
     Pre-amplifier              Corporation              EM30265             07032613           Sep. 16, 2019
                                 CO.,LTD
     Pre-amplifier                        HP               8447D           2727A05017           Sep. 16, 2019

     Loop antenna                   ZHINAN              ZN30900A                12024           Oct. 20, 2019

Broadband Antenna                Schwarzbeck            VULB9163                 340            Sep. 02, 2019

     Horn Antenna                Schwarzbeck           BBHA 9120D                631            Oct. 20, 2019

     Horn Antenna                    A-INFO           LB-180400-KF J211020657                   Sep. 16, 2019
    Antenna Mast                     Keleto                RE-AM                 N/A                   N/A
      Coax cable
                                          TCT           RE-low-01                N/A            Sep. 16, 2019
     (9KHz-1GHz)
      Coax cable
                                          TCT           RE-high-02               N/A            Sep. 16, 2019
    (9KHz-40GHz)
      Coax cable
                                          TCT           RE-low-03                N/A            Sep. 16, 2019
     (9KHz-1GHz)
      Coax cable
                                          TCT           RE-high-04               N/A            Sep. 16, 2019
    (9KHz-40GHz)

                                    Shurple
  EMI Test Software                                       EZ-EMC                 N/A                   N/A
                                  Technology

Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to
        international system unit (SI).




                                                                                                       Page 42 of 57

 Hotline: 400-6611-140         Tel: 86-755-27673339        Fax: 86-755-27673332          http://www.tct-lab.com


                                                                                              Report No.: TCT190703E017

  6.11.3.      Test Data

Duty cycle correction factor for average measurement

  2DH5 on time (One Pulse) Plot on Channel 39




  2DH5 on time (Count Pulses) Plot on Channel 39




 Note:
    1. Worst case Duty cycle = on time/100 milliseconds = (2.896*16)/100= 0.4634
    2. Worst case Duty cycle correction factor = 20*log (Duty cycle) = -6.68dB
    3. 2DH5 has the highest duty cycle worst case and is reported.
    4. The average levels were calculated from the peak level corrected with duty cycle correction factor (-6.68dB)
        derived from 20log (dwell time/100ms). This correction is only for signals that hop with the fundamental signal,
        such as band-edge and harmonic. Other spurious signals that are independent of the hopping signal would not
        use this correction.




                                                                                                        Page 43 of 57

  Hotline: 400-6611-140        Tel: 86-755-27673339         Fax: 86-755-27673332          http://www.tct-lab.com


                                                                             Report No.: TCT190703E017

Please refer to following diagram for individual
                                              Below 1GHz
Horizontal:




                                                                                     Page 44 of 57

   Hotline: 400-6611-140    Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                          Report No.: TCT190703E017


Vertical:




Note: 1.The low frequency, which started from 9KHz~30MHz, was pre-scanned and the result which was 20dB lower than
        the limit line per 15.31(o) was not reported

       2. Measurements were conducted in all three channels (high, middle, low) and two modulation (GFSK,
          Pi/4DQPSK) and the worst case Mode (Highest channel and Pi/4DQPSK) was submitted only.




                                                                                                    Page 45 of 57

   Hotline: 400-6611-140        Tel: 86-755-27673339      Fax: 86-755-27673332        http://www.tct-lab.com


                                                                                              Report No.: TCT190703E017


                                                    Above 1GHz
     Modulation Type: Pi/4DQPSK
     Low channel: 2402 MHz
                           Peak          AV    Correction Emission Level
     Frequency Ant. Pol. reading       reading  Factor                   Peak limit AV limit Margin
       (MHz)      H/V                                     Peak      AV   (dBµV/m) (dBµV/m)     (dB)
                          (dBµV)       (dBuV)   (dB/m) (dBµV/m) (dBµV/m)
        2390       H       45.73          ---    -8.27    37.46      ---    74        54     -16.54
        4804       H       46.85          ---     0.66    47.51      ---    74        54      -6.49
        7206       H       38.24          ---     9.50    47.74      ---    74        54      -6.26
         ---       H        ---           ---      ---     ---       ---    ---       ---       ---

       2390         V        43.88        ---      -8.27       35.61        ---        74         54        -18.39
       4804         V        44.96        ---       0.66       45.62        ---        74         54         -8.38
       7206         V        37.48        ---       9.50       46.98        ---        74         54         -7.02
        ---         V         ---         ---        ---        ---         ---        ---        ---          ---

     Middle channel: 2441 MHz
                           Peak          AV    Correction Emission Level
     Frequency Ant. Pol.                                                 Peak limit AV limit Margin
       (MHz)      H/V     reading      reading  Factor    Peak      AV   (dBµV/m) (dBµV/m)    (dB)
                          (dBµV)       (dBµV)   (dB/m) (dBµV/m) (dBµV/m)
        4882       H       43.63          ---    0.99     44.62      ---    74        54     -9.38
        7323       H       38.02          ---    9.87     47.89      ---    74        54      -6.11
         ---       H         ---          ---      ---     ---       ---    ---       ---      ---

       4882         V        44.17        ---       0.99       45.16         ---       74         54         -8.84
       7323         V        37.25        ---       9.87       47.12         ---       74         54         -6.88
        ---         V         ---         ---        ---        ---         ----       ---        ---          ---

     High channel: 2480 MHz
                          Peak           AV    Correction Emission Level
     Frequency Ant. Pol. reading       reading  Factor                   Peak limit AV limit Margin
       (MHz)       H/V                                    Peak      AV   (dBµV/m) (dBµV/m)     (dB)
                         (dBµV)        (dBµV)   (dB/m) (dBµV/m) (dBµV/m)
       2483.5       H     46.32           ---    -7.83    38.49      ---    74        54     -15.51
        4960        H     46.78           ---     1.33    48.11      ---    74        54      -5.89
        7440        H     38.01           ---    10.22    48.23      ---    74        54      -5.77
         ---        H       ---           ---      ---     ---       ---    ---       ---       ---

      2483.5        V        48.25        ---      -7.83       40.42        ---        74         54        -13.58
       4960         V        47.38        ---       1.33       48.71        ---        74         54         -5.29
       7440         V        37.44        ---      10.22       47.66        ---        74         54         -6.34
        ---         V         ---         ---        ---        ---         ---        ---        ---          ---
Note:
1.    Emission Level=Peak Reading + Correction Factor; Correction Factor= Antenna Factor + Cable loss – Pre-amplifier
2.    Margin (dB) = Emission Level (Peak) (dBµV/m)-Average limit (dBµV/m)
3.    The emission levels of other frequencies are very lower than the limit and not show in test report.
4.    Measurements were conducted from 1 GHz to the 10th harmonic of highest fundamental frequency.
5.    Data of measurement shown “---“in the above table mean that the reading of emissions is attenuated more than 20 dB
      below the limits or the field strength is too small to be measured.
6.    Measurements were conducted in all two modulation (GFSK, Pi/4DQPSK), and the worst case Mode (Pi/4DQPSK)
      was submitted only.




                                                                                                        Page 46 of 57

     Hotline: 400-6611-140       Tel: 86-755-27673339        Fax: 86-755-27673332         http://www.tct-lab.com


                                                                         Report No.: TCT190703E017


                   Appendix A: Photographs of Test Setup
                           Product: Electric Guitar Digital Amp
                                     Model: TM-15
                                   Radiated Emission




                                                                                 Page 47 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT190703E017


                                   Conducted Emission




                                                                                 Page 48 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT190703E017


                        Appendix B: Photographs of EUT
                         Product: Electric Guitar Digital Amp
                                    Model: TM-15
                                  External Photos




                                                                                 Page 49 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT190703E017




                                                                                 Page 50 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT190703E017




                                                                                 Page 51 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT190703E017


                         Product: Electric Guitar Digital Amp
                                    Model: TM-15
                                   Internal Photos




                                                                                 Page 52 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT190703E017




                                                                                 Page 53 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT190703E017




                                                                                 Page 54 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT190703E017




                                                                                 Page 55 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT190703E017




                                                                                 Page 56 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT190703E017




                            *****END OF REPORT*****




                                                                                 Page 57 of 57

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com



Document Created: 2019-08-02 09:57:54
Document Modified: 2019-08-02 09:57:54

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC