LCS180529041AEB report-DTS

FCC ID: 2APP6AG-40A

Test Report

Download: PDF
FCCID_3906016

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB




                                                  FCC TEST REPORT

                                                                 For

                                                 Aroma Music Co., Ltd.
                                              ACOUSTIC GUITAR AMP
                                                  Test Model: AG-40A




 Prepared for                             :    Aroma Music Co., Ltd.
 Address                                  :    Floor 6 , Building 56 Baotian Industry Zone, Baotian 3 Road Bao An
                                               District, Shenzhen 518102 China

 Prepared by                              :    Shenzhen LCS Compliance Testing Laboratory Ltd.
 Address                                  :    1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an
                                               District, Shenzhen, Guangdong, China
 Tel                                      :    (+86)755-82591330
 Fax                                      :    (+86)755-82591332
 Web                                      :    www.LCS-cert.com
 Mail                                     :    webmaster@LCS-cert.com

 Date of receipt of test sample           :    May 31, 2018
 Number of tested samples                 :    1
 Serial number                            :    Prototype
 Date of Test                             :    May 31, 2018~ June 11, 2018
 Date of Report                           :    June 13, 2018




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 1 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


                                                 FCC TEST REPORT
                                             FCC CFR 47 PART 15 C(15.247)

 Report Reference No. ................. : LCS180529041AEB

 Date of Issue .................................. : June 13, 2018

 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd.

 Address .......................................... : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue,
                                                      Bao'an District, Shenzhen, Guangdong, China
 Testing Location/ Procedure .......... : Full application of Harmonised standards ■
                                                      Partial application of Harmonised standards □
                                                      Other standard testing method □
 Applicant’s Name ......................... : Aroma Music Co., Ltd.

 Address .......................................... : Floor 6 , Building 56 Baotian Industry Zone, Baotian 3 Road Bao An
                                                      District, Shenzhen 518102 China
 Test Specification

 Standard ........................................ : FCC CFR 47 PART 15 C(15.247)

 Test Report Form No. .................. : LCSEMC-1.0

 TRF Originator ............................... : Shenzhen LCS Compliance Testing Laboratory Ltd.

 Master TRF .................................... : Dated 2011-03
 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
 This publication may be reproduced in whole or in part for non-commercial purposes as long as the
 Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the
 material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
 assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
 placement and context.
 EUT Description. .......................... : ACOUSTIC GUITAR AMP

 Trade Mark ..................................... : AROMA

 Model/ Type reference ................... : AG-40A

 Ratings ........................................... : DC18V by Rechargeable Li-ion Battery(2200mAh)
                                                       Recharge Voltage: 24V ,1.5A
 Result ........................................... : Positive

            Compiled by:                                    Supervised by:                                Approved by:




   Raing Ye/ File administrators                Calvin Weng/ Technique principal                     Gavin Liang/ Manager




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 2 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


                                                      FCC -- TEST REPORT

                                                                                                 June 13, 2018
       Test Report No. :                           LCS180529041AEB                               Date of issue



   Type / Model...........................          : AG-40A

   EUT.........................................     : ACOUSTIC GUITAR AMP


   Applicant...............................         : Aroma Music Co., Ltd.
   Address..................................        : Floor 6 , Building 56 Baotian Industry Zone, Baotian 3 Road Bao An
                                                      District, Shenzhen 518102 China
   Telephone...............................         : /
   Fax..........................................    : /


   Manufacturer........................             : Aroma Music Co., Ltd.
   Address...................................       : Floor 6 , Building 56 Baotian Industry Zone, Baotian 3 Road Bao An
                                                      District, Shenzhen 518102 China
   Telephone...............................         : /
   Fax..........................................    : /


   Factory...................................       : Aroma Music Co., Ltd.
   Address...................................       : Floor 6 , Building 56 Baotian Industry Zone, Baotian 3 Road Bao An
                                                      District, Shenzhen 518102 China
   Telephone...............................         : /
   Fax..........................................    : /




                              Test Result                                                        Positive
   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test laboratory.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 3 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


                                                         Revision History

           Revision                         Issue Date                         Revisions                        Revised By
              000                         June 13, 2018                       Initial Issue                     Gavin Liang




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 4 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                  FCC ID: 2APP6AG-40A                      Report No.: LCS180529041AEB


                                                                  TABLE OF CONTENTS
1. GENERAL INFORMATION ................................................................................................................................... 6
   1.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................................ 6
   1.2. HOST SYSTEM CONFIGURATION LIST AND DETAILS .......................................................................................... 6
   1.3. EXTERNAL I/O CABLE ......................................................................................................................................... 6
   1.4. DESCRIPTION OF TEST FACILITY ........................................................................................................................ 6
   1.5. STATEMENT OF THE MEASUREMENT UNCERTAINTY .......................................................................................... 7
   1.6. MEASUREMENT UNCERTAINTY ........................................................................................................................... 7
   1.7. DESCRIPTION OF TEST MODES .......................................................................................................................... 7
2. TEST METHODOLOGY ......................................................................................................................................... 8
   2.1. EUT CONFIGURATION......................................................................................................................................... 8
   2.2. EUT EXERCISE ................................................................................................................................................... 8
   2.3. GENERAL TEST PROCEDURES ........................................................................................................................... 8
3. SYSTEM TEST CONFIGURATION ...................................................................................................................... 9
   3.1. JUSTIFICATION..................................................................................................................................................... 9
   3.2. EUT EXERCISE SOFTWARE ................................................................................................................................ 9
   3.3. SPECIAL ACCESSORIES ...................................................................................................................................... 9
   3.4. BLOCK DIAGRAM/SCHEMATICS........................................................................................................................... 9
   3.5. EQUIPMENT MODIFICATIONS .............................................................................................................................. 9
   3.6. TEST SETUP ........................................................................................................................................................ 9
4. SUMMARY OF TEST RESULTS ........................................................................................................................ 10
5. TEST RESULT ....................................................................................................................................................... 11
   5.1. ON TIME AND DUTY CYCLE .............................................................................................................................. 11
   5.2. MAXIMUM CONDUCTED OUTPUT POWER MEASUREMENT ............................................................................... 12
   5.3. POWER SPECTRAL DENSITY MEASUREMENT .................................................................................................. 13
   5.4. 6 DB SPECTRUM BANDWIDTH MEASUREMENT ................................................................................................ 14
   5.5. RADIATED EMISSIONS MEASUREMENT ............................................................................................................. 15
   5.6. CONDUCTED SPURIOUS EMISSIONS AND BAND EDGES TEST ......................................................................... 24
   5.7. AC POWER LINE CONDUCTED EMISSIONS ........................................................................................................ 25
   5.8. BAND-EDGE MEASUREMENTS FOR RADIATED EMISSIONS ................................................................................ 27
   5.9. ANTENNA REQUIREMENTS ................................................................................................................................ 29
6. LIST OF MEASURING EQUIPMENTS .............................................................................................................. 31
7. TEST SETUP PHOTOGRAPHS OF EUT .......................................................................................................... 32
8. EXTERIOR PHOTOGRAPHS OF THE EUT ..................................................................................................... 32
9. INTERIOR PHOTOGRAPHS OF THE EUT ...................................................................................................... 32




      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                     Page 5 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


1. GENERAL INFORMATION
  1.1. Description of Device (EUT)
         EUT                                      : ACOUSTIC GUITAR AMP

         Test Model                               : AG-40A

         Power Supply                             : DC18V by Rechargeable Li-ion Battery(2200mAh)
                                                    Recharge Voltage: 24V            ,1.5A
         Hardware version                         : V20180316

         Software version                         : 1.0

         BluetoothOperation frequency : 2402MHz-2480MHz

         Bluetooth Version                        : V4.1

         Bluetooth Channel Number                 : 79 Channels for Bluetooth V3.0 (DSS)
                                                    40 Channels for Bluetooth V4.0 (DTS)

         Bluetooth Channel Spacing                : 1MHz for Bluetooth V3.0 (DSS)
                                                    2MHz for Bluetooth V4.0 (DTS)

         Bluetooth Modulation Type                : GFSK, π/4-DQPSK, 8-DPSK for Bluetooth V3.0 (DSS)
                                                    GFSK, for Bluetooth V4.0 (DTS)

         Antenna Description                      : PCB Antenna, -5.47dBi


  1.2. Host System Configuration List and Details

                   Manufacturer                Description              Model            Serial Number          Certificate
            ShenZhen Xinspower
                                                 Adapter         A361-2401500I                   --               FCC
            Technology Co., Ltd.

  1.3. External I/O Cable

                I/O Port Description                          Quantity                                  Cable
                     MIC Port                                      1                                    N/A
                     Guitar Port                                   1                                    N/A
                     AMP Port                                      1                                    N/A

  1.4. Description of Test Facility
    FCC Registration Number. is 254912.
    Industry Canada Registration Number. is 9642A-1.
    ESMD Registration Number. is ARCB0108.
    UL Registration Number. is 100571-492.
    TUV SUD Registration Number. is SCN1081.
    TUV RH Registration Number. is UA 50296516-001

   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 6 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB
    NVLAP Registration Code is 600167-0

   The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.10:2013 and CISPR
   16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.

  1.5. Statement of the Measurement Uncertainty
    The data and results referenced in this document are true and accurate. The reader is cautioned that
    there may be errors within the calibration limits of the equipment and facilities. The measurement
    uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
    “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty
    in EMC Measurements” and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025.
    Furthermore, component and process variability of devices similar to that tested may result in additional
    deviation. The manufacturer has the sole responsibility of continued compliance of the device.

  1.6. Measurement Uncertainty
                     Test Item                       Frequency Range                      Uncertainty                Note
                                                       9KHz~30MHz                           ±3.10dB                   (1)
                                                      30MHz~200MHz                          ±2.96dB                   (1)
             Radiation Uncertainty           :      200MHz~1000MHz                          ±3.10dB                   (1)
                                                      1GHz~26.5GHz                          ±3.80dB                   (1)
                                                     26.5GHz~40GHz                          ±3.90dB                   (1)
            Conduction Uncertainty           :        150kHz~30MHz                          ±1.63dB                   (1)
               Power disturbance             :        30MHz~300MHz                          ±1.60dB                   (1)

    (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
    level using a coverage factor of k=2.


  1.7. Description of Test Modes
    The EUT has been tested under operating condition.
    This test was performed with EUT in X, Y, Z position and the worst case was found when EUT in X
    position.
    Pre-test AC conducted emission at both voltage AC 120V/60Hz and AC 240V/50Hz, recorded worst case.
    Worst-case mode and channel used for 150 KHz-30 MHz power line conducted emissions was the mode
    and channel with the highest output power, which was determined to be BT LE mode (Low Channel).
    Worst-case mode and channel used for 9 KHz-1000 MHz radiated emissions was the mode and channel
    with the highest output power, that was determined to be BT LE mode(Low Channel).
    Worst-Case data rates were utilized from preliminary testing of the Chipset, worst-case data rates used
    during the testing are as follows:
    BT LE: 1 Mbps, GFSK.

    BLE 4.1

         Frequency Band             Channel No.           Frequency(MHz)               Channel No.            Frequency(MHz)
                                         0                     2402                        20                      2442
                                         1                     2404                        --                       --
                                         2                     2406                        --                       --
          2402~2480MHz
                                        --                      --                         37                      2476
                                        --                      --                         38                      2478
                                        19                     2440                        39                      2480


   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 7 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


2. TEST METHODOLOGY
    All measurements contained in this report were conducted with ANSI C63.10-2013, American National
    Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.
    The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and
    conducted emissions measurement was performed at Shenzhen LCS Compliance Testing Laboratory Ltd.

  2.1. EUT Configuration
    The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions
    requirement and operating in a manner that intends to maximize its emission characteristics in a
    continuous normal application.

  2.2. EUT Exercise
    The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of the
    measurements.
    According to FCC’s request, Test Procedure KDB558074 D01 DTS Meas. Guidance is required to be
    used for this kind of FCC 15.247 digital modulation device.
    According to its specifications, the EUT must comply with the requirements of the Section 15.203, 15.205,
    15.207, 15.209 and 15.247 under the FCC Rules Part 15 Subpart C.

  2.3. General Test Procedures

   2.3.1 Conducted Emissions

    The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in
    Section 6.2.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the frequency range
    between 0.15 MHz and 30MHz using Quasi-peak and average detector modes.

   2.3.2 Radiated Emissions

    The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360
    degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving
    antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be
    maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find
    out the maximum emissions, exploratory radiated emission measurements were made according to the
    requirements in Section 6.3 of ANSI C63.10-2013.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 8 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


3. SYSTEM TEST CONFIGURATION
  3.1. Justification
    The system was configured for testing in a continuous transmit condition. The duty cycle is 100% and the
    average correction factor is 0.

  3.2. EUT Exercise Software
    The system was configured for testing in a continuous transmits condition and change test channels by
    software (BQB Test Tool) provided by application.

  3.3. Special Accessories
                                                                                          Serial
                                          Description                 Model                                  Certificate
              Manufacturer                                                               Number
                  Lenovo                       PC                     B470                    --                 DOC
                  Lenovo             AC/DC ADAPTER                ADP-90DDB                   --                 DOC


  3.4. Block Diagram/Schematics
    Please refer to the related document

  3.5. Equipment Modifications
    Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

  3.6. Test Setup
    Please refer to the test setup photo.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 9 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB



4. SUMMARY OF TEST RESULTS

                                       Applied Standard: FCC Part 15 Subpart C
                 FCC Rules                            Description of Test                                       Result
                 §15.247(b)                    Maximum Conducted Output Power                                  Compliant
                 §15.247(e)                                Power Spectral Density                              Compliant
               §15.247(a)(2)                                    6dB Bandwidth                                  Compliant
                 §15.247(a)                                  Occupied Bandwidth                                Compliant
           §15.209, §15.247(d)               Radiated and Conducted Spurious Emissions                         Compliant
                   §15.205                             Emissions at Restricted Band                            Compliant
                 §15.207(a)                                 Conducted Emissions                                Compliant
                   §15.203                                 Antenna Requirements                                Compliant
            §15.247(i)§2.1093                                    RF Exposure                                   Compliant




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 10 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB



5. TEST RESULT
  5.1. On Time and Duty Cycle
   5.1.1. Standard Applicable

    None; for reporting purpose only.

   5.1.2. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of the spectrum analyzer.

   5.1.3. Test Procedures

    1. Set the center frequency of the spectrum analyzer to the transmitting frequency;
    2. Set the span=0MHz, RBW=8MHz, VBW=50MHz, Sweep time=5ms;
    3. Detector = peak;
    4. Trace mode = Single hold.

   5.1.4. Test Setup Layout




   5.1.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.

   5.1.6. Test result
    The test data Please see the appendix of Duty Cycle B.1




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 11 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB
5.2. Maximum Conducted Output Power Measurement
   5.2.1. Standard Applicable

    For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands:
    1 Watt. As an alternative to a peak power measurement, compliance with the one Watt limit can be based
    on a measurement of the maximum conducted output power. Maximum Conducted Output Power is
    defined as the total transmit power delivered to all antennas and antenna elements averaged across all
    symbols in the signaling alphabet when the transmitter is operating at its maximum power control level.
    Power must be summed across all antennas and antenna elements. The average must not include any
    time intervals during which the transmitter is off or is transmitting at a reduced power level. If multiple
    modes of operation are possible (e.g., alternative modulation methods), the maximum conducted output
    power is the highest total transmit power occurring in any mode.

   5.2.2. Test Procedures

    The transmitter output (antenna port) was connected to the spectrum analyzer.
    According to KDB558074 D01 DTS Measurement Guidance Section 9.1 Maximum peak conducted output
    power 9.1.1.
    This procedure shall be used when the measurement instrument has available a resolution bandwidth that
    is greater than the DTS bandwidth.
    a) Set the RBW ≥ DTS bandwidth.
    b) Set VBW ≥ 3  RBW.
    c) Set span ≥ 3 x RBW
    d) Sweep time = auto couple.
    e) Detector = peak.
    f) Trace mode = max hold.
    g) Allow trace to fully stabilize.
    h) Use peak marker function to determine the peak amplitude level.

   5.2.3. Test Setup Layout




   5.2.4. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.

   5.2.5. Test Result of Maximum Conducted Output Power

Remark:
1. Test results including cable loss;
2. The test data Please see the appendix of Maximum peak conducted output power B.2




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 12 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


  5.3. Power Spectral Density Measurement

   5.3.1. Standard Applicable

    According to §15.247(e): For digitally modulated systems, the power spectral density conducted from the
    intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time
    interval of continuous transmission.

   5.3.2. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer.

    5.3.3. Test Procedures

    1. Use this procedure when the maximum peak conducted output power in the fundamental emission is
    used to demonstrate compliance.
    2. The power was monitored at the coupler port with a Spectrum Analyzer. The power level was set to the
    maximum level.
    3. Set the RBW = 3 kHz.
    4. Set the VBW ≥ 3*RBW
    5. Set the span to 1.5 times the DTS channel bandwidth.
    6. Detector = peak.
    7. Sweep time = auto couple.
    8. Trace mode = max hold.
    9. Allow trace to fully stabilize.
    10. Use the peak marker function to determine the maximum power level.
    11. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat.
    12. The resulting peak PSD level must be 8 dBm.

   5.3.4. Test Setup Layout




   5.3.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.


   5.3.6. Test Result of Power Spectral Density

Remark:
1. Test results including cable loss;
2. The test data Please see the appendix of Maximum Peak power spectral density B.3

   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 13 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


  5.4. 6 dB Spectrum Bandwidth Measurement

   5.4.1. Standard Applicable

    According to §15.247(a) (2): For digital modulation systems, the minimum 6 dB bandwidth shall be at least
    500 kHz.

   5.4.2. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of the Spectrum Analyzer.

           Spectrum Parameter                                  Setting
           Attenuation                                         Auto
           RBW                                                 100KHz
           VBW                                                 ≥3*RBW
           Span Frequency                                      > RBW
           Detector                                            Peak
           Trace                                               Max Hold
           Sweep Time                                          1ms
                                                                                                                                 5.4.3.
   Test Procedures

    1. The transmitter output (antenna port) was connected to the spectrum analyzer in peak hold mode.
    2. The resolution bandwidth and the video bandwidth were set according to KDB558074.
    3. Measured the spectrum width with power higher than 6dB below carrier.

   5.4.4. Test Setup Layout




   5.4.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.

   5.4.6. Test Result of 6dB Spectrum Bandwidth

Remark:
1. Test results including cable loss;
2. The test data Please see the appendix of 6dB Bandwidth B.4




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 14 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


  5.5. Radiated Emissions Measurement
   5.5.1. Standard Applicable

    15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in any
    of the frequency bands listed below:

                   MHz                            MHz                            MHz                     GHz
                0.090-0.110                  16.42-16.423                     399.9-410                4.5-5.15
                \1\ 0.495-0.505              16.69475-16.69525                608-614                  5.35-5.46
                2.1735-2.1905                16.80425-16.80475                960-1240                 7.25-7.75
                4.125-4.128                  25.5-25.67                       1300-1427                8.025-8.5
                4.17725-4.17775              37.5-38.25                       1435-1626.5              9.0-9.2
                4.20725-4.20775              73-74.6                          1645.5-1646.5            9.3-9.5
                6.215-6.218                  74.8-75.2                        1660-1710                10.6-12.7
                6.26775-6.26825              108-121.94                       1718.8-1722.2            13.25-13.4
                6.31175-6.31225              123-138                          2200-2300                14.47-14.5
                8.291-8.294                  149.9-150.05                     2310-2390                15.35-16.2
                8.362-8.366                  156.52475-156.52525              2483.5-2500               17.7-21.4
                8.37625-8.38675              156.7-156.9                      2690-2900                22.01-23.12
                8.41425-8.41475              162.0125-167.17                  3260-3267                23.6-24.0
                12.29-12.293.                167.72-173.2                     3332-3339                31.2-31.8
                12.51975-12.52025            240-285                          3345.8-3358              36.43-36.5
                12.57675-12.57725            322-335.4                        3600-4400                (\2\)
                13.36-13.41
    \1\ Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
    \2\ Above 38.6
    According to §15.247 (d): 20dBc in any 100 kHz bandwidth outside the operating frequency band. In case
    the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table
    below has to be followed.

                Frequencies                                Field Strength                        Measurement Distance
                   (MHz)                                 (microvolts/meter)                            (meters)
                0.009~0.490                                2400/F(KHz)                                   300
                0.490~1.705                                24000/F(KHz)                                   30
                1.705~30.0                                       30                                       30
                   30~88                                        100                                        3
                  88~216                                        150                                        3
                  216~960                                       200                                        3
                 Above 960                                      500                                        3

   5.5.2. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of spectrum analyzer and
    receiver.

     Spectrum Parameter                                       Setting
     Attenuation                                              Auto
     Start Frequency                                          1000 MHz
     Stop Frequency                                           10th carrier harmonic
     RB / VB (Emission in restricted band)                    1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average
     RB / VB (Emission in non-restricted band)                1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average

    Receiver Parameter                                           Setting
    Attenuation                                                  Auto
    Start ~ Stop Frequency                                       9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG
    Start ~ Stop Frequency                                       150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG
    Start ~ Stop Frequency                                       30MHz~1000MHz / RB/VB 120kHz/1MHz for QP


   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 15 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


   5.5.3. Test Procedures


    1) Sequence of testing 9 kHz to 30 MHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0° to 315° using 45° steps.
    --- The antenna height is 0.8 meter.
    --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
    emissions

    Final measurement:
    --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
    position (0° to 360°) and by rotating the elevation axes (0° to 360°).
    --- The final measurement will be done in the position (turntable and elevation) causing the highest
    emissions with QPK detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to
    the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be
    stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 16 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


    2) Sequence of testing 30 MHz to 1 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0° to 315° using 45° steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height changes from 1 to 3 meter.
    --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to
    find the maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software maximize
    the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter.
    --- The final measurement will be done with QP detector with an EMI receiver.
    --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable
    angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the
    premeasurement with marked maximum final measurements and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 17 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


    3) Sequence of testing 1 GHz to 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0° to 315° using 45° steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height scan range is 1 meter to 2.5 meter.
    --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the
    maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software maximize
    the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter. This
    procedure is repeated for both antenna polarizations.
    --- The final measurement will be done in the position (turntable, EUT-table and antenna polarization)
    causing the highest emissions with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna
    polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of
    the premeasurement with marked maximum final measurements and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 18 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


    4) Sequence of testing above 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 1 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The antenna is moved spherical over the EUT in different polarizations of the antenna.

    Final measurement:
    --- The final measurement will be performed at the position and antenna orientation for all detected
    emissions that were found during the premeasurements with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and limit
    will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 19 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


   5.5.4. Test Setup Layout




    Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20
    dB/decade form 3m to 1m.
    Distance extrapolation factor = 20 log (specific distanc [3m] / test distance [1m]) (dB);
    Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB].

   5.5.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 20 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


   5.5.6. Results of Radiated Emissions (9 KHz~30MHz)

             Temperature                        23.8℃                         Humidity                        53.7%
             Test Engineer                     Tom Liu                    Configurations                      BT LE

                Freq.                   Level                Over Limit               Over Limit
               (MHz)                   (dBuV)                  (dB)                    (dBuV)                   Remark
                  -                       -                      -                        -                    See Note

    Note:
    The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible
    value has no need to be reported.
    Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
    Limit line = specific limits (dBuV) + distance extrapolation factor.

   5.5.7. Results of Radiated Emissions (30MHz~1GHz)

             Temperature                        23.8℃                       Humidity                         53.7%
             Test Engineer                     Tom Liu                  Configurations                BT LE (Low CH)

Test result for BT LE (Low Channel)




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 21 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB

                  Vertical




                Horizontal




    Note:
    1). Pre-scan all modes and recorded the worst case results in this report (BT LE (Low Channel)). Emission
    level (dBuV/m) = 20 log Emission level (uV/m).
    2). Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.


   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 22 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


   5.5.8. Results for Radiated Emissions (Above 1GHz)

    BT LE
    Channel 0 / 2402 MHz
                                Ant.        Pre.       Cab.
   Freq.        Reading                                            Measured          Limit       Margin
                                Fac.        Fac.       Loss                                                   Remark           Pol.
   MHz           dBuV                                               dBuV/m          dBuV/m        dB
                               dB/m          dB         dB
  4804.00        54.34         33.06       35.04       3.94          56.30           74.00        -17.70        Peak       Horizontal
  4804.00        39.13         33.06       35.04        3.94         41.09           54.00        -12.91      Average      Horizontal
  4804.00        57.49         33.06       35.04        3.94         59.45           74.00        -14.55        Peak         Vertical
  4804.00        41.79         33.06       35.04        3.94         43.75           54.00        -10.25      Average        Vertical

    Channel 19 / 2440 MHz
                                Ant.       Pre.       Cab.
   Freq.        Reading                                          Measured          Limit        Margin
                                Fac.       Fac.       Loss                                                   Remark            Pol.
   MHz           dBuV                                             dBuV/m          dBuV/m         dB
                               dB/m         dB         dB
  4880.00         54.99        33.16      35.15       3.96          56.96          74.00        -17.04         Peak        Horizontal
  4880.00         43.38        33.16      35.15       3.96          45.35          54.00         -8.65       Average       Horizontal
  4880.00         60.85        33.16      35.15       3.96          62.82          74.00        -11.18         Peak          Vertical
  4880.00         41.28        33.16      35.15       3.96          43.25          54.00        -10.75       Average         Vertical

    Channel 39 / 2480 MHz
                                Ant.       Pre.       Cab.
   Freq.        Reading                                          Measured          Limit        Margin
                                Fac.       Fac.       Loss                                                   Remark            Pol.
   MHz           dBuV                                             dBuV/m          dBuV/m         dB
                               dB/m         dB         dB
  4960.00         54.68        33.26      35.14       3.98          56.78          74.00        -17.22         Peak        Horizontal
  4960.00         41.15        33.26      35.14       3.98          43.25          54.00        -10.75       Average       Horizontal
  4960.00         60.74        33.26      35.14       3.98          62.84          74.00        -11.16         Peak          Vertical
  4960.00         42.89        33.26      35.14       3.98          44.99          54.00         -9.01       Average         Vertical



    Notes:
    1). Measuring frequencies from 9 KHz~10th harmonic or 26.5GHz (which is less), No emission found
    between lowest internal used/generated frequency to 30MHz.
    2). Radiated emissions measured in frequency range from 9 KHz~10th harmonic or 26.5GHz (which is
    less) were made with an instrument using Peak detector mode.
    3). Data of measurement within this frequency range shown “ --- ” in the table above means the reading of
    emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to
    be measured.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 23 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


  5.6. Conducted Spurious Emissions and Band Edges Test
   5.6.1. Standard Applicable

    According to §15.247 (d): In any 100 kHz bandwidth outside the frequency band in which the spread
    spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
    produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
    band that contains the highest level of the desired power, based on either an RF conducted or a radiated
    measurement. Attenuation below the general limits specified in Section 15.209(a) is not required. In
    addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also
    comply with the radiated emission limits specified in Section 15.209(a) (see Section 15.205(c)).

   5.6.2. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of the spectrum analyzer.

     Spectrum Parameter                                                     Setting
     Detector                                                               Peak
     Attenuation                                                            Auto
     RB / VB (Emission in restricted band)                                  100KHz/300KHz
     RB / VB (Emission in non-restricted band)                              100KHz/300KHz


   5.6.3. Test Procedures

    The transmitter output is connected to a spectrum analyzer. The resolution bandwidth is set to 100 kHz.
    The video bandwidth is set to 300 kHz
    The spectrum from 9 kHz to 26.5GHz is investigated with the transmitter set to the lowest, middle, and
    highest channels.

   5.6.4. Test Setup Layout

    This test setup layout is the same as that shown in section 5.4.4.

   5.6.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.

   5.6.6. Test Results of Conducted Spurious Emissions

                                       Frequency             Spurious RF Conducted Emission                     Limits
    Test Mode          Channel                                                                                               Verdict
                                         (MHz)                            (dBc)                                 (dBc)
                            0             2402                            <-20
   GFSK - BLE              19             2440                            <-20                                    -20         PASS
                           39             2480                            <-20
Remark:
1. Measured RF conducted spurious emissions at difference data rate for each mode and recorded worst
   case for each mode.
2. Test results including cable loss;
3. “---“means that the fundamental frequency not for 15.209 limits requirement.
4. The test data Please see the appendix of RF Conducted Spurious Emissions B.6
5. The test data Please see the appendix of Band-edge for RF Conducted Emissions B.7




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 24 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB



  5.7. AC Power line conducted emissions
   5.7.1 Standard Applicable

    According to §15.207 (a): For an intentional radiator which is designed to be connected to the public utility
    (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any
    frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit
    decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at
    specific frequency range are listed as follows:

                        Frequency Range                                         Limits (dBμV)
                              (MHz)                                   Quasi-peak                         Average
                           0.15 to 0.50                                66 to 56                          56 to 46
                            0.50 to 5                                    56                                46
                             5 to 30                                     60                                50

              * Decreasing linearly with the logarithm of the frequency

   5.7.2 Block Diagram of Test Setup


                                                              Vert. reference
                                                                 plane
                                                                                                        EMI receiver




                                                   EUT




                           LISN                                              Reference ground plane




   5.7.3 Test Results

    PASS
    The test data please refer to following page.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 25 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB



Test Results for AC 120V/60Hz @ GFSK (worst case)
          Temperature                  25.7℃                          Humidity                      53.4%
          Test Engineer                Tom Liu                        Configurations                BT

Line




Neutral




***Note: Pre-scan all modes and recorded the worst case results in this report

   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 26 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


   5.8. Band-edge measurements for radiated emissions
   5.8.1 Standard Applicable
   In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated
   intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall
   be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the
   desired power, based on either an RF conducted or a radiated measurement, provided the transmitter
   demonstrates compliance with the peak conducted power limits. If the transmitter complies with the
   conducted power limits based on the use of RMS averaging over a time interval, as permitted under
   paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20
   dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated
   emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated
   emission limits specified in §15.209(a) (see §15.205(c)).

   5.8.2. Test Setup Layout




   5.8.3. Measuring Instruments and Setting
   Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer.

   5.8.4. Test Procedures

    According to KDB 558074 D01 for Antenna-port conducted measurement. Antenna-port conducted
    measurements may also be used as an alternative to radiated measurements for demonstrating
    compliance in the restricted frequency bands. If conducted measurements are performed, then proper
    impedance matching must be ensured and an additional radiated test for cabinet/case spurious emissions
    is required.
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal from
     an external generator.
2. Remove the antenna from the EUT and then connect to a low loss RF cable from the antenna port to an
     EMI test receiver, then turn on the EUT and make it operate in transmitting mode. Then set it to Low
     Channel and High Channel within its operating range, and make sure the instrument is operated in its
     linear range.
3. Set both RBW and VBW of spectrum analyzer to 100 kHz with a convenient frequency span including
     100kHz bandwidth from band edge, for Radiated emissions restricted band RBW=1MHz, VBW=3MHz for
     peak detector and RBW=1MHz, VBW=1/B for Peak detector.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the graph
     with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.
6. Measure the conducted output power (in dBm) using the detector specified by the appropriate regulatory
     agency (see 12.2.2, 12.2.3, and 12.2.4 for guidance regarding measurement procedures for determining
     quasi-peak, peak, and average conducted output power, respectively).
7. Add the maximum transmit antenna gain (in dBi) to the measured output power level to determine the
     EIRP level (see 12.2.5 for guidance on determining the applicable antenna gain)
8. Add the appropriate maximum ground reflection factor to the EIRP level (6 dB for frequencies ≤ 30 MHz,
     4.7 dB for frequencies between 30 MHz and 1000 MHz, inclusive and 0 dB for frequencies > 1000 MHz).
9. For devices with multiple antenna-ports, measure the power of each individual chain and sum the EIRP of
     all chains in linear terms (e.g., Watts, mW).
10. Convert the resultant EIRP level to an equivalent electric field strength using the following relationship:

    E = EIRP – 20log D + 104.8

Where:
E = electric field strength in dBμV/m,
    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 27 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB
EIRP = equivalent isotropic radiated power in dBm
D = specified measurement distance in meters.
11. Since the out-of-band characteristics of the EUT transmit antenna will often be unknown, the use of a
    conservative antenna gain value is necessary. Thus, when determining the EIRP based on the measured
    conducted power, the upper bound on antenna gain for a device with a single RF output shall be selected
    as the maximum in-band gain of the antenna across all operating bands, or 2 dBi, whichever is greater.
    However, for devices that operate in multiple frequency bands while using the same transmit antenna, the
    highest gain of the antenna within the operating band nearest in frequency to the restricted band emission
    being measured may be used in lieu of the overall highest gain when the emission is at a frequency that is
    within 20 percent of the nearest band edge frequency, but in no case shall a value less than 2 dBi be used.
12. Compare the resultant electric field strength level to the applicable regulatory limit.
13. Perform radiated spurious emission test duress until all measured frequencies were complete.

   5.8.5 Test Results

Remark:
1. Test results including cable loss;
2. “---“means that the fundamental frequency not for 15.209 limits requirement.
3. Average Values = Average Reading Values - Duty Cycle Factor
4. The test data Please see the appendix of Restrict-band band-edge measurements B.8




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 28 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


  5.9. Antenna Requirements
   5.9.1 Standard Applicable

    According to antenna requirement of §15.203.
    An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
    responsible party shall be used with the device. The use of a permanently attached antenna or of an
    antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply
    with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can be
    re-placed by the user, but the use of a standard antenna jack or electrical connector is prohibited. This
    requirement does not apply to carrier current devices or to devices operated under the provisions of
    Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to
    intentional radiators that must be professionally installed, such as perimeter protection systems and some
    field disturbance sensors, or to other intentional radiators which, in accordance with Section 15.31(d),
    must be measured at the installation site. However, the installer shall be responsible for ensuring that the
    proper antenna is employed so that the limits in this Part are not exceeded.

    And according to §15.247(4)(1), system operating in the 2400-2483.5MHz bands that are used
    exclusively for fixed, point-to-point operations may employ transmitting antennas with directional gain
    greater than 6dBi provided the maximum peak output power of the intentional radiator is reduced by 1 dB
    for every 3 dB that the directional gain of the antenna exceeds 6dBi.

   5.9.2 Antenna Connected Construction
   5.9.2.1. Standard Applicable

    According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
    furnished by the responsible party shall be used with the device.

   5.9.2.2. Antenna Connector Construction

    The directional gains of antenna used for transmitting is -5.47dBi, and the antenna is an internal antenna
    connect to PCB board and no consideration of replacement. Please see EUT photo for details.

   5.9.2.3. Results: Compliance.

    Measurement
    The antenna gain of the complete system is calculated by the difference of radiated power in EIRP and
    the conducted power of the module.
    Conducted power refers ANSI C63.10:2013 Output power test procedure for DTS devices.
    Radiated power refers to ANSI C63.10:2013 Radiated emissions tests.

    Measurement parameters

                                                     Measurement parameter
         Detector:                                                Peak
         Sweep Time:                                              Auto
         Resolution bandwidth:                                    1MHz
         Video bandwidth:                                         3MHz
         Trace-Mode:                                              Max hold




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 29 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB


    Limits

                                    FCC                                                         ISED
                                                            Antenna Gain
                                                                6 dBi


    Note: The antenna gain of the complete system is calculated by the difference of radiated power in EIRP
    and the conducted power of the module.

                                                   Lowest Channel             Middle Channel             Highest Channel
               Tnom                Vnom
                                                     2402 MHz                   2440 MHz                    2480 MHz
             Conducted power [dBm]
                 Measured with                            2.661                      3.851                      4.302
                GFSK modulation
              Radiated power [dBm]
                 Measured with                            -3.203                    -2.158                     -1.811
                GFSK modulation
              Gain [dBi] Calculated                      -5.864                     -6.009                     -6.113
                        Measurement uncertainty                                  ± 1.6 dB (cond.) / ± 3.8 dB (rad.)




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 30 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB

6. LIST OF MEASURING EQUIPMENTS
   Item      Equipment           Manufacturer           Model No.              Serial No.           Last Cal.          Next Cal.
    1      Power Meter                 R&S                 NRVS                 100444             2017-06-17         2018-06-16
    2     Power Sensor                 R&S               NRV-Z81                100458             2017-06-17         2018-06-16
    3     Power Sensor                 R&S               NRV-Z32                 10057             2017-06-17         2018-06-16
          ESA-E SERIES
    4      SPECTRUM                  Agilent              E4407B            MY41440754             2017-11-17         2018-11-16
           ANALYZER
            MXA Signal
    5                                Agilent              N9020A            MY49100040             2017-06-17         2018-06-16
             Analyzer
           SPECTRUM
    6                                  R&S                  FSP                 100503             2017-06-17         2018-06-16
           ANALYZER
              3m Semi
                                    SIDT
    7         Anechoic                                   SAC-3M              03CH03-HY             2017-06-17         2018-06-16
                                 FRANKONIA
              Chamber
            Positioning
    8                                   MF               MF-7082                     /             2017-06-17         2018-06-16
            Controller
              EMI Test
    9                                AUDIX                   E3                    N/A             2017-06-17         2018-06-16
              Software
              EMI Test
   10                                  R&S                 ESR 7                101181             2017-06-17         2018-06-16
              Receiver
   11       AMPLIFIER               QuieTek           QTK-A2525G           CHM10809065             2017-11-17         2018-11-16
            Active Loop         SCHWARZBEC
   12                                      FMZB 1519B                            00005             2017-06-23         2018-06-22
             Antenna                K
                                SCHWARZBEC
   13     By-log Antenna                                VULB9163               9163-470            2018-05-02         2019-05-01
                                    K
   14      Horn Antenna               EMCO                  3115                  6741             2017-06-23         2018-06-22
          Broadband Horn SCHWARZBEC
   15                                                  BBHA 9170                   791             2017-09-21         2018-09-20
             Antenna         K
            Broadband           SCHWARZBEC
   16                                                   BBV 9719               9719-025            2017-09-21         2018-09-20
            Preamplifier            K
   17     RF Cable-R03m              Jye Bao              RG142                  CB021             2017-06-17         2018-06-16
                                                       SUCOFLEX
   18     RF Cable-HIGH             SUHNER                                   03CH03-HY             2017-06-17         2018-06-16
                                                          106
              TEST
   19                                  R&S                  ESCI                101142             2017-06-17         2018-06-16
            RECEIVER
   20     RF Cable-CON              UTIFLEX           3102-26886-4               CB049             2017-06-17         2018-06-16
                                SCHWARZBEC
   21     10dB Attenuator                  MTS-IMP136 261115-001-0032 2017-06-17                                      2018-06-16
                                    K
   22     Artificial Mains             R&S                ENV216                101288             2017-06-17         2018-06-16
                                 JS Tonscend
   23     RF Control Unit                                JS0806-2             178060073            2017-10-28         2018-10-27
                                  Corporation
            JS1120-3
                                 JS Tonscend
   24      BT/WIFI Test                                  JS1120-3                    /                  N/A                N/A
                                  Corporation
            Software
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 31 of 32


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2APP6AG-40A            Report No.: LCS180529041AEB



7. TEST SETUP PHOTOGRAPHS OF EUT
    Please refer to separated files for Test Setup Photos of the EUT.



8. EXTERIOR PHOTOGRAPHS OF THE EUT
    Please refer to separated files for External Photos of the EUT.


9. INTERIOR PHOTOGRAPHS OF THE EUT
   Please refer to separated files for Internal Photos of the EUT.




                            ----------------THE END OF REPORT---------------




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 32 of 32



Document Created: 2019-11-20 15:39:52