RF Exposure Info

FCC ID: 2APNH-AWC1040

RF Exposure Info

Download: PDF
FCCID_4306098

                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch




                                                                    Report No.: SZEM190101017503
                                                                    Page:        1 of 9


1     COVER PAGE

                       Human Exposure Report
Application No.:               SZEM1901010175CR
Applicant:                     SHENZHEN LANNENGSHITONG ELECTRONICS CO., LTD
                               Floor3 No.40 xinhe road shangmugu village Pinghu neighborhood Longgang
Address of Applicant:
                               District, Shenzhen, 518110, China.
Manufacturer:                  SHENZHEN LANNENGSHITONG ELECTRONICS CO., LTD
                               Floor3 No.40 xinhe road shangmugu village Pinghu neighborhood Longgang
Address of Manufacturer:
                               District, Shenzhen, 518110, China.
Factory:                       SHENZHEN LANNENGSHITONG ELECTRONICS CO., LTD
                               Floor3 No.40 xinhe road shangmugu village Pinghu neighborhood Longgang
Address of Factory:
                               District, Shenzhen, 518110, China.
Equipment Under Test (EUT):
EUT Name:                      Ubiolabs Wireless Charging Dock and Hub
Model No.:                     AWC1040
Trade mark:                    Ubiolabs
FCC ID:                        2APNH-AWC1040
Standards:                     47 CFR PART 1, Subpart I, Section 1.1310
Date of Receipt:               2019-01-09
Date of Test:                  2019-01-09 to 2019-05-14
Date of Issue:                 2019-05-17
Test Result :                    Pass*
* In the configuration tested, the EUT complied with the standards specified above




           Keny Xu
     EMC Laboratory Manager


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                           Report No.: SZEM190101017503
                                                           Page:       2 of 9




                                        Revision Record
     Version       Chapter               Date                 Modifier       Remark

     01                              2019-05-17                              Original




Authorized for issue by:




                             Bill Chen /Project Engineer




                             Eric Fu /Reviewer


                                               SGS-CSTC Standards Technical Services Co., Ltd.
                                               Shenzhen Branch
                                                                                                    Report No.: SZEM190101017503
                                                                                                    Page:       3 of 9




2         Contents
1      COVER PAGE ............................................................................................................................................1

2      CONTENTS ................................................................................................................................................3

3      GENERAL INFORMATION ........................................................................................................................4
    3.1    DETAILS OF E.U.T. ...................................................................................................................................4
    3.2    DESCRIPTION OF SUPPORT UNITS .............................................................................................................4
    3.3    TEST LOCATION ........................................................................................................................................5
    3.4    TEST FACILITY ..........................................................................................................................................5
    3.5    DEVIATION FROM STANDARDS ...................................................................................................................5
    3.6    ABNORMALITIES FROM STANDARD CONDITIONS..........................................................................................5
4      EQUIPMENTS USED DURING TEST ........................................................................................................6

5      TEST RESULTS .........................................................................................................................................7
    5.1 RF EXPOSURE TEST .................................................................................................................................7
       5.1.1 E.U.T. Operation ............................................................................................................................7
       5.1.2 Measurement Data.........................................................................................................................8
6      PHOTOGRAPHS ........................................................................................................................................9
    6.1    TEST SETUP PHOTOS ................................................................................................................................9


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                               Report No.: SZEM190101017503
                                                               Page:       4 of 9




3     General Information
3.1     Details of E.U.T.
      Power supply:            Input:DC 5-15V/3.5A Max
                               Output:Wireless 5V 10W Max
                                       Double USB 1/2: 5V2.4A each
      Test voltage:            110V
      Cable:                   USB cable:175cm unshielded
      Antenna Type:            Loop Antenna
      Modulation Type:         Load Modulation
      Operation Frequency:     110.77kHz to 206.15kHz
      Remark:                  Tests were conducted in all three load modes and the worst case 10W(DC
                               9V/1.1A) is reported only.



3.2    Description of Support Units
       The EUT has been tested as an independent unit.


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                  Report No.: SZEM190101017503
                                                                  Page:       5 of 9




3.3    Test Location
      All tests were performed at:
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab,
      No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China
      518057.
      Tel: +86 755 2601 2053         Fax: +86 755 2671 0594
      No tests were sub-contracted.

3.4    Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      • CNAS (No. CNAS L2929)
      CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
      Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
      Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
      Laboratories) for the competence in the field of testing.
      • A2LA (Certificate No. 3816.01)
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
      American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
      • VCCI
      The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
      Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
      Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
      been registered in accordance with the Regulations for Voluntary Control Measures with Registration
      No.: G-20026, R-14188, C-12383 and T-11153 respectively.
      • FCC –Designation Number: CN1178
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
      as an accredited testing laboratory.
      Designation Number: CN1178. Test Firm Registration Number: 406779.
      • Innovation, Science and Economic Development Canada
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
      by ISED as an accredited testing laboratory.
      CAB identifier: CN0006.
      IC#: 4620C.

3.5    Deviation from Standards
      None.

3.6    Abnormalities from Standard Conditions
      None.


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                         Report No.: SZEM190101017503
                                                         Page:       6 of 9




4   Equipments Used during Test

    Item     Test Equipment        Manufacturer   Model No.   Inventory No. Cal. Due date

           Electric and Magnetic
     1                                Narda       EHP-50F       EMC092        2020-02-06
              Field Analyzer


                                  SGS-CSTC Standards Technical Services Co., Ltd.
                                  Shenzhen Branch
                                                                      Report No.: SZEM190101017503
                                                                      Page:       7 of 9




5       Test Results
5.1       RF Exposure test
        Test Requirement:               47 CFR PART 1, Subpart I, Section 1.1310
        Measurement Distance:           15cm
        Limit:

    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                              (A) Limits for Occupational/Controlled Exposures
           0.3-3.0                 614                      1.63                *(100)             6
           3.0-30                1842/f                    4.89/f              *(900/f2)           6
           30-300                 61.4                     0.163                   1.0             6
          300-1500                  /                         /                  f/300             6
        1500-100,000                /                         /                    5               6
                          (B) Limits for General Population/Uncontrolled Exposure
          0.3-1.34                 614                      1.63                *(100)             30
           1.34-30                824/f                    2.19/f              *(180/f2)           30
           30-300                 27.5                     0.073                   0.2             30
          300-1500                  /                         /                 f/1500             30
        1500-100,000                /                         /                    1.0             30
    F=frequency in MHz
    *=Plane-wave equivalent power density
    RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules.
    The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
    150kHz:614V/m,1.63A/m).
5.1.1     E.U.T. Operation

        Operating Environment:
        Temperature:      24.5 °C           Humidity:    52 % RH         Atmospheric Pressure: 1015 mbar

        EUT Operation:
        This device has been tested the worst status of full load and the device has been tested with mobile
         phone at zero charge, intermediate charge, and full charge.


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                   Report No.: SZEM190101017503
                                                                   Page:       8 of 9




5.1.2   Measurement Data



        Magnetic Field Emissions
          Operation     Test Distance     Test Position         Probe Measure      50% Limit
          frequency                                              Result (A/m)
                                (cm)                                                     (A/m)
                                                 Side 1              0.0192              0.815
                                                 Side 2              0.0237              0.815
           147.2 kHz              15             Side 3              0.0212              0.815
                                                 Side 4              0.0234              0.815
                                                  Top                0.0161              0.815



        Magnetic Field Emissions

         Operation       Test                             Probe Measure Result(A/m)
                                        Test                                                50%Limit
         frequency     Distance
                                       Position     zero        intermediate   full
                                                    charge         charge      charge            (A/m)
                           (cm)
                                        Side 1       0.0206        0.0177       0.0143           0.815
                                        Side 2       0.0244        0.0213       0.0192           0.815
          147.2 kHz        15           Side 3       0.0225        0.0194       0.0177           0.815
                                        Side 4       0.0229        0.0218       0.0203           0.815
                                         Top         0.0174        0.0156       0.0134           0.815


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                 Report No.: SZEM190101017503
                                                                 Page:       9 of 9




6     Photographs
6.1    Test setup photos
      Please refer to RF Exposure Setup Photos.




                                         - End of the Report -



Document Created: 2019-05-27 07:53:50
Document Modified: 2019-05-27 07:53:50

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC