RF Exposure

FCC ID: 2APN5-S55

RF Exposure Info

Download: PDF
FCCID_4013509

Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG180809004-00A

FCC §15.247 (i) , §1.1310 , §2.1091- MAXIMUM PERMISSIBLE EXPOSURE
(MPE)
Applicable Standard
According to subpart 15.247(i)and subpart §1.1310, systems operating under the provisions of this section
shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in
excess of the Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                          (B) Limits for General Population/Uncontrolled Exposure
Frequency Range         Electric Field       Magnetic Field        Power Density            Averaging Time
     (MHz)             Strength (V/m)        Strength (A/m)           (mW/cm2)                (minutes)
    0.3–1.34                 614                   1.63                 *(100)                    30
    1.34–30                 824/f                 2.19/f               *(180/f²)                  30
    30–300                   27.5                 0.073                   0.2                     30
   300–1500                   /                      /                  f/1500                    30
 1500–100,000                 /                      /                    1.0                     30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.

Calculation Formula:

Prediction of power density at the distance of the applicable MPE limit:
S = PG/4R² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);


Calculated Data:

                                           Maximum Power
       Frequency                                                Evaluation       Power
                        Antenna Gain          Including                                      MPE Limit
         Range                                                   Distance       Density
                                              Tolerance                                      (mW/cm2)
         (MHz)                                                    (cm)         (mW/cm2)
                       (dBi)   (numeric)   (dBm)     (mW)
        2412-2462        1        1.26       24     251.19         20.00          0.06           1.0

Note:
The Maximum Power Including Tolerance was declared by manufacturer.

Result: Compliance, The device meets FCC MPE at 20 cm distance




                                                                                                 Page 11 of 45



Document Created: 2018-09-19 17:53:57
Document Modified: 2018-09-19 17:53:57

© 2024 FCC.report