RF Exposure

FCC ID: 2APN5-MINI

RF Exposure Info

Download: PDF
FCCID_4291793

Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG181218004-00A

FCC §15.247 (i) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to§15.247(i) and §1.1310, systems operating under the provisions of this section shall be
operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess
of the Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                          (B) Limits for General Population/Uncontrolled Exposure
Frequency Range         Electric Field       Magnetic Field        Power Density               Averaging Time
     (MHz)             Strength (V/m)        Strength (A/m)           (mW/cm2)                   (minutes)
    0.3–1.34                 614                   1.63                 *(100)                       30
    1.34–30                 824/f                 2.19/f               *(180/f²)                     30
    30–300                   27.5                 0.073                   0.2                        30
   300–1500                   /                      /                  f/1500                       30
 1500–100,000                 /                      /                    1.0                        30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.


Calculated Formulary:

Predication of MPE limit at a given distance
S = PG/4R² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);


Calculated Data:

                                            Max. Target Power
       Frequency                                                    Evaluation        Power       MPE
                        Antenna Gain             including
         Range                                                       Distance        Density      Limit
                                                Tolerance
         (MHz)                                                        (cm)           (W/m2)      (W/m2)
                     (dBi)     (numeric)    (dBm)       (mW)
        2412-2462      2          1.58        18        63.10          20.00          0.02         1.0

Note: the Max. Target Power including Tolerance was declared by manufacturer.

Result: Compliance, The device meets MPE requirement for Devices Used by the General Public
(Uncontrolled Environment) at distance ≥20 cm.