Test Report

FCC ID: 2APMD-PA136A

Test Report

Download: PDF
FCCID_4131437

                                             FCC PART 15C

                                             TEST REPORT
                                                              For


                     Shenzhen Xintuo Supply Chain LTD
    F1 Building 2 Snow Industrial Park SnowElephant Community, Bantian Street, Longgang,
                                 Shenzhen, Guangdong, China


                                        FCC ID: 2APMD-PA136A



            Report Type:                                 Product Name:
            Original Report                              Fast Wireless Charger



                  Report Number:           RDG181219003-00


                      Report Date:         2019-01-07
                                           Jerry Zhang
                                           EMC Manager
                     Reviewed By:

                 Test Laboratory:          Bay Area Compliance Laboratories Corp. (Dongguan)
                                           No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
      used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must
      not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the
      Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with
      an asterisk “*”.


  Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RDG181219003-00




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC §1.1310, §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) .............................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  TEST DATA ..................................................................................................................................................................9
FCC§15.203 - ANTENNA REQUIREMENT............................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA CONNECTED CONSTRUCTION ....................................................................................................................11
FCC §15.207 – AC LINE CONDUCTED EMISSION .............................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  TEST PROCEDURE ......................................................................................................................................................13
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................13
  TEST RESULTS SUMMARY ..........................................................................................................................................14
  TEST DATA ................................................................................................................................................................14
FCC §15.205 & §15.209 - RADIATED EMISSIONS TEST ....................................................................................17
  APPLICABLE STANDARD ............................................................................................................................................17
  EUT SETUP ................................................................................................................................................................17
  EMI TEST RECEIVER SETUP .......................................................................................................................................18
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................18
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  TEST RESULTS SUMMARY ..........................................................................................................................................19
  TEST DATA ................................................................................................................................................................19




                                                                                                                                                            Page 2 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG181219003-00

GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)

                          EUT Name:      Fast Wireless Charger
                          EUT Model:     PA136A
                  Rated Input Voltage:   DC 5V form adapter
                  External Dimension:    Length (165 mm)*Width (99.5 mm)*High (125.7 mm)
                       Serial Number:    181219003
                  EUT Received Date:     2018.12.21


Objective
This Type approval report is prepared on behalf of Shenzhen Xintuo Supply Chain LTD in accordance with
Part 2, Subpart J, and Part 15, Subparts A and C of the Federal Communications Commission’s rules.

The objective is to determine the compliance of the EUT with FCC rules, 15.203, 15.205, 15.207, 15.209.


Related Submittal(s)/Grant(s)
No related submittal(s)/grant(s).


Test Methodology
All measurements detailed in this Test Report were performed in accordance with ANSI C63.10-2013
“American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices”.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).
The radiated testing was performed at an antenna-to-EUT distance of 3 meters.


Measurement Uncertainty
               Parameter                                 Measurement Uncertainty
       Occupied Channel Bandwidth                                   ±5 %
                                                           9kHz~30MHz: 4.12dB
             radiated Emissions             30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for Vertical
                                             200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical
               Temperature                                          ±1℃
                 Humidity                                           ±5%
       DC and low frequency voltages                               ±0.4%
                Duty Cycle                                           1%
        AC Power Lines Conducted                          3.12 dB (150 kHz to 30 MHz)
                 Emission




                                                                                                Page 3 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG181219003-00

Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier : CN0022.




                                                                                             Page 4 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG181219003-00

SYSTEM TEST CONFIGURATION
Justification

The system was configured for testing in a test mode

The device is a wireless charger operation on frequency 110 kHz - 205 kHz.


EUT Exercise Software

No software used in test.


Support Equipment List and Details

        Manufacturer                Description             Model                     Serial Number
          APPLE                       Phone               MGAA2CG/A                  FK1R96UYG5QT
          APPLE                       Phone               MQ8E2CH/A                  FD3X40UEJCU0
          Unknown                    Adapter               QC24-US                           /


Support Cable List and Details

                            Shielding                    Length
     Cable Description                   Ferrite Core                         From              To
                              Type                        (m)
         USB Cable             No              No           1                Adapter           EUT
         USB Cable             No              No           1                  EUT             Phone




                                                                                               Page 5 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG181219003-00

Block Diagram of Test Setup




                                                                      Page 6 of 23


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG181219003-00

SUMMARY OF TEST RESULTS

             FCC Rules                       Description of Test                 Result
           FCC§1.1310 &
                                    Maximum Permissible Exposure(MPE)          Compliance
             §2.1091
            FCC§15.203                      Antenna Requirement                Compliance
            FCC§15.207                  AC Line Conducted Emission             Compliance
          §15.209 §15.205                  Radiated Emission Test              Compliance




                                                                                            Page 7 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG181219003-00

FCC §1.1310, §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Applicable Standard
According to subpart §1.1310, systems operating under the provisions of this section shall be operated in a
manner that ensures that the public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                         (B) Limits for General Population/Uncontrolled Exposure
Frequency Range        Electric Field       Magnetic Field        Power Density           Averaging Time
     (MHz)            Strength (V/m)        Strength (A/m)           (mW/cm2)               (minutes)
    0.3–1.34                614                   1.63                 *(100)                   30
     1.34–30               824/f                 2.19/f               *(180/f²)                 30
     30–300                 27.5                 0.073                   0.2                    30
    300–1500                 /                       /                  f/1500                  30
  1500–100,000               /                       /                   1.0                    30

f = frequency in MHz; * = Plane-wave equivalent power density;

According with KDB 680106 D01 RF Exposure Wireless Charging Apps v03 clause 3 c)




According to 680106 D01 RF Exposure Wireless Charging App v03 clause 5 b)




                                                                                                Page 8 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG181219003-00

Block Diagram of Test Setup




                                                      15cm




Note: 20 cm for Top test.


Test Equipment List and Details

                                                                        Serial     Calibration    Calibration
     Manufacturer               Description              Model
                                                                       Number         Date         Due Date
         Narda          Exposure Level Tester           ELT-400        N-0229       2017-11-15    2019-11-15
                                                       ELT Probe
         Narda                 B Field Probe                           M-0666       2017-11-15    2019-11-15
                                                        100cm2
       Amplifier
                            Isotropic Field Probe       FP5000         301825       2018-11-22    2021-11-22
       Research

    * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
     have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

             Temperature:                     24 oC
        Relative Humidity:                    40 %
            ATM Pressure:                 100.2 kPa

     * The testing was performed by Neil Liao on 2018-12-27.

Test mode: Transmitting




                                                                                                     Page 9 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                                     Report No.: RDG181219003-00

H-field Strength
          Frequency      Position     Position     Position     Position      Position       50%       Limit
            Range           A            B            C            D             E          Limit       Test
            (kHz)         (A/m)        (A/m)        (A/m)        (A/m)         (A/m)        (A/m)      (A/m)

           110-205        0.190        0.191        0.196        0.189         0.190       0.815       1.63


Note: Test with 15cm distance from the center of the probe(s) to the edge of the device, 20 cm for top test.

E-field Strength
          Frequency      Position     Position     Position     Position      Position       50%       Limit
            Range           A            B            C            D             E          Limit       Test
            (kHz)         (V/m)        (V/m)        (V/m)        (V/m)         (V/m)        (V/m)      (V/m)

           110-205        4.136        4.23         4.05         4.215         2.983        307         614


Note: Test with 15cm distance from the center of the probe(s) to the edge of the device, 20 cm for top test.

Result: Compliance

Considerations of compliance 680106 D01 RF Exposure Wireless Charging App v03 clause 5 b:

(1) Power transfer frequency is less than 1 MHz.

Yes, the operation frequency is 110-205 kHz.

(2) Output power from each primary coil is less than or equal to 15 watts.

Yes, the maximum output power of primary coil is 10 Watts, less than 15 watts.

(3) The transfer system includes only single primary and secondary coils. This includes charging systems
that may have multiple primary coils and clients that are able to detect and allow coupling only between
individual pairs of coils.

The transfer system includes only single primary coils to detect and allow coupling only between
individual pairs of coils.

(4) Client device is placed directly in contact with the transmitter.

Yes, client device is placed directly in contact with the transmitter

(5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).

Yes, mobile exposure conditions only

 (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from
all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

Yes, the test result for H and E-field strength less than 50% of the MPE limit.




                                                                                                         Page 10 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG181219003-00

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.


Antenna Connected Construction
The EUT has an integral antenna arrangement, which was permanently attached and fulfill the requirement
of this section. Please refer to the EUT photos.

Result: Compliance.




                                                                                                Page 11 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG181219003-00


FCC §15.207 – AC LINE CONDUCTED EMISSION

EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207 limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main LISN with an AC 120V/60Hz power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




                                                                                              Page 12 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG181219003-00

Test Equipment List and Details

                                                                     Serial        Calibration    Calibration
      Manufacturer              Description           Model
                                                                    Number            Date         Due Date
           R&S               EMI Test Receiver      ESCS 30        830245/006      2018-12-10      2019-12-10
         Unknown               Coaxial Cable       C-NJNJ-50        C-0200-01      2018-09-05      2019-09-05
           R&S                 Test Software         EMC32        Version8.53.0        N/A            N/A
           R&S              Two-line V-network      ENV 216          101614        2018-12-10      2019-12-10
           R&S                    L.I.S.N           ESH2-Z5        892107/021      2018-09-19      2019-09-19

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure
During the conducted emission test, the adapter was connected to the outlet of the LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.

According FCC publication number 174176,for a device with a permanent antenna operating at or below
30 MHz, the measurements done with a suitable dummy load, in lieu of the permanent antenna under the
following conditions: (1) perform the AC line conducted tests with the permanent antenna to determine
compliance with the Section 15.207 limits outside the transmitter's fundamental emission band; (2) retest
with a dummy load in lieu of the permanent antenna to determine compliance with the Section 15.207
limits within the transmitter's fundamental emission band.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF

Herein,
VC: corrected voltage amplitude
VR: reading voltage amplitude

Ac: attenuation caused by cable loss

VDF: voltage division factor of AMN or ISN

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

                                    Margin = Limit – Corrected Amplitude



                                                                                                    Page 13 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG181219003-00

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207.


Test Data
    Environmental Conditions

              Temperature:            21.4 C
         Relative Humidity:            40 %
             ATM Pressure:          100.9 kPa

      The testing was performed by Lily Xie on 2019-01-03.




                                                                                           Page 14 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                                             Report No.: RDG181219003-00

Test Mode: Transmitting
AC 120V, 60 Hz, Line:


                         80

                         70
                                                                                                     Quasi-Peak Limit
                         60
                                                                                                        Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300    400 500     800 1M        2M     3M     4M 5M 6   8 10M          20M     30M
                                                                Frequency in Hz



     Frequency                  Quasi Peak          Bandwidth               Corr.      Margin      Limit
                                                                   Line                                          Comment
       (MHz)                     (dBμV)               (kHz)                 (dB)        (dB)      (dBμV)
      0.152410                     40.6               9.000         L1      11.1        25.2        65.9         Compliance
      0.180171                     36.3               9.000         L1      10.8        28.1        64.5         Compliance
      0.507637                     41.7               9.000         L1       9.9        14.3        56.0         Compliance
      0.515791                     32.7               9.000         L1       9.9        23.3        56.0         Compliance
      0.549741                     34.5               9.000         L1       9.9        21.5        56.0         Compliance
      0.604902                     33.2               9.000         L1       9.8        22.8        56.0         Compliance

     Frequency                   Average            Bandwidth               Corr.      Margin      Limit
                                                                   Line                                          Comment
       (MHz)                     (dBμV)               (kHz)                 (dB)        (dB)      (dBμV)
      0.503608                     30.0               9.000         L1       9.9        16.0        46.0         Compliance
      0.558572                     26.3               9.000         L1       9.8        19.7        46.0         Compliance
      0.845331                     24.3               9.000         L1       9.8        21.8        46.0         Compliance
      1.181325                     20.5               9.000         L1       9.8        25.5        46.0         Compliance
      3.519348                     23.8               9.000         L1       9.8        22.2        46.0         Compliance
      6.196694                     23.5               9.000         L1       9.8        26.5        50.0         Compliance




                                                                                                                    Page 15 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                                          Report No.: RDG181219003-00

AC120 V, 60 Hz, Neutral:


                         80

                         70
                                                                                                   Quasi-Peak Limit
                         60
                                                                                                      Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                               Frequency in Hz



     Frequency                  Quasi Peak         Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.503608                     42.7              9.000         N        9.9        13.3      56.0          Compliance
      0.549741                     39.8              9.000         N        9.8        16.2      56.0          Compliance
      0.604902                     36.5              9.000         N        9.8        19.5      56.0          Compliance
      3.098088                     31.0              9.000         N        9.8        25.0      56.0          Compliance
      3.750995                     29.3              9.000         N        9.8        26.7      56.0          Compliance
      4.726090                     31.4              9.000         N        9.8        24.6      56.0          Compliance

     Frequency                   Average           Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.503608                     35.3              9.000         N        9.9        10.7      46.0          Compliance
      0.558572                     28.8              9.000         N        9.8        17.2      46.0          Compliance
      2.771062                     27.9              9.000         N        9.8        18.1      46.0          Compliance
      3.098088                     27.6              9.000         N        9.8        18.4      46.0          Compliance
      3.750995                     28.7              9.000         N        9.8        17.3      46.0          Compliance
      4.726090                     27.7              9.000         N        9.8        18.3      46.0          Compliance




                                                                                                                  Page 16 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG181219003-00

FCC §15.205 & §15.209 - RADIATED EMISSIONS TEST
Applicable Standard
As per FCC Part 15.209

 (a) Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not
exceed the field strength levels specified in the following table:

  Frequency (MHz)             Field strength (microvolts/meter)             Measurement distance (meters)
0.009-0.490              2400/F(kHz)                                                                            300
0.490-1.705              24000/F(kHz)                                                                            30
1.705-30.0               30                                                                                      30
30-88                    100**                                                                                       3
88-216                   150**                                                                                       3
216-960                  200**                                                                                       3
Above 960                500                                                                                         3
      **Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this
section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz.
However, operation within these frequency bands is permItted under other sections of this part, e.g., §§15.231 and
15.241.


EUT Setup




The radiated emission tests were performed in the 3-meter chamber test site, using the setup accordance
with the ANSI C63.10-2013. The specification used was the FCC Part Subpart C limits.

The spacing between the peripherals was 10 cm.




                                                                                                      Page 17 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG181219003-00


EMI Test Receiver Setup
The system was investigated from 9 kHz to 1 GHz.

During the radiated emission test, the EMI test Receiver was set with the following configurations:

                       Frequency Range              RBW          Video B/W      Measurement
                       9 kHz – 150 kHz             200 Hz           1 kHz        QP/Average
                      150 kHz – 30 MHz              9 kHz          30 kHz        QP/Average
                     30 MHz – 1000 MHz             120 kHz         300 kHz            QP

The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak
detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated emission
limits in these three bands are based on measurements employing an average detector.

If the maximized peak measured value complies with the limit, then it is unnecessary to perform an
QP/Average measurement


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Amplitude reading. The basic equation is as follows:

                  Corr. Ampl. = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

                                           Margin = Limit - Corr. Ampl.


Test Equipment List and Details

                                                                      Serial       Calibration    Calibration
    Manufacturer            Description             Model
                                                                     Number           Date         Due Date
         R&S             EMI Test Receiver           ESCI            100224         2018-12-10    2019-12-10
         Farad             Test Software           EZ-EMC            V1.1.4.2          N/A            N/A
        EMCO               Passive Loop              6512           9706-1206       2017-03-05    2020-03-04
       Unknown             Coaxial Cable          C-NJNJ-50         C-0400-01       2018-09-05    2019-09-05
       Unknown             Coaxial Cable          C-NJNJ-50         C-0075-01       2018-09-05    2019-09-05
       Unknown             Coaxial Cable          C-NJNJ-50         C-1400-01       2018-05-06    2019-05-06
    Sunol Sciences            Antenna                JB3           A060611-1        2017-11-10    2020-11-10
          HP                 Amplifier              8447D          2727A05902       2018-09-05    2019-09-05

    * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
     have been performed, traceable to National Primary Standards and International System of Units (SI).



                                                                                                    Page 18 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG181219003-00

Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.209&15.205.


Test Data
    Environmental Conditions

            Temperature:               24 oC
       Relative Humidity:              40 %
          ATM Pressure:              100.2 kPa

    * The testing was performed by Neil Liao on 2018-12-27.

Test mode: Transmitting




                                                                                          Page 19 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG181219003-00

1) 9 kHz~30MHz:




                       Receiver                 Correction     Cord.
        Frequency                                                         Limit      Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                         (dBμV/m)      (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
          0.0240        -4.98         peak        79.02        74.04      120.00      45.96
          0.0354         -9.35        peak           75.95    66.60       116.62      50.02
          0.1113         47.58        peak           41.53    89.11       106.67      17.56
          0.1198         21.59        peak           40.75    62.34       106.03      43.69
          0.1440         26.54        peak           39.05    65.59       104.43      38.84




                                                                                        Page 20 of 23


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG181219003-00




                      Receiver                 Correction     Cord.
       Frequency                                                         Limit      Margin
                      Reading      Detector     Factor        Amp.
         (MHz)                                                         (dBμV/m)      (dB)
                      (dBμV)                    (dB/m)      (dBμV/m)
         0.1796        30.16         peak        36.54        66.70      102.52      35.82
         2.4485        36.89         peak        14.99        51.88      69.54       17.66
         3.0455        44.51         peak        13.35        57.86      69.54       11.68
         4.5380         45.99        peak           11.24    57.23       69.54       12.31




                                                                                       Page 21 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG181219003-00

2) Above 30 MHz

Horizontal




                       Receiver                 Correction     Cord.
        Frequency                                                         Limit      Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                         (dBμV/m)      (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
         32.9100        34.36          QP          -0.50       33.86      40.00        6.14
         50.3700        45.03          QP         -11.25       33.78      40.00        6.22
         125.0600        39.59        peak           -4.62    34.97       43.50        8.53
         172.5900        40.77        peak           -6.76    34.01       43.50        9.49
         299.6600        33.22        peak           -3.85    29.37       46.00       16.63
         361.7400        31.08        peak           -2.79    28.29       46.00       17.71




                                                                                        Page 22 of 23


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG181219003-00

Vertical




                       Receiver                 Correction     Cord.
        Frequency                                                         Limit      Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                         (dBμV/m)      (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
           32.9100      31.48         peak         -0.50       30.98      40.00        9.02
           52.3100      44.23          QP         -11.82       32.41      40.00        7.59
           132.8200      41.64        peak           -4.95    36.69       43.50        6.81
           320.0300      42.92        peak           -3.47    39.45       46.00        6.55
           375.3200      35.83        peak           -2.73    33.10       46.00       12.90
           934.0400      36.52        peak           -3.43    33.09       46.00       12.91

                                  ***** END OF REPORT *****