RF Exposure

FCC ID: 2APJZ-TW181113

RF Exposure Info

Download: PDF
FCCID_4302906

Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ190111811-00B

FCC §15.247 (i) & §1.1307 (b) (1) & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.247 (i) and subpart 1.1307 (b)(1), 2.1091 systems operating under the provisions
of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in
excess of the communication guidelines.

                                Limits for General Population/Uncontrolled Exposure

                               Limits for General Population/Uncontrolled Exposure
              Frequency          Electric Field     Magnetic Field        Power          Averaging
                Range               Strength           Strength          Density           Time
                (MHz)                (V/m)              (A/m)           (mW/cm2)         (Minutes)
               0.3-1.34               614                  1.63         *(100)                 30
               1.34-30               824/f                2.19/f       *(180/f2)               30
               30-300                 27.5                0.073             0.2                30
              300-1500                    /                 /           f/1500                 30
             1500-100,000                 /                 /               1.0                30

f = frequency in MHz
* = Plane-wave equivalent power density


Result
Calculated Formulary:

Predication of MPE limit at a given distance

                                                           PG
                                                     S=
                                                          4R 2
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW).
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
    factor, is normally numeric gain.
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


                          Antenna Gain         Tune-up Power       Evaluation         Power
   Frequency                                                                                        MPE Limit
                                                                    Distance         Density
     (MHz)          (dBi)       (numeric)     (dBm)        (mW)                                     (mW/cm2)
                                                                     (cm)           (mW/cm2)
      2412            2            1.58         23          200        20              0.063             1

Note: To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm
from nearby persons.

Result: Compliance



FCC Part 15.247                                                                                     Page 13 of 49



Document Created: 2019-06-01 12:56:56
Document Modified: 2019-06-01 12:56:56