Test Report

FCC ID: 2APJZ-CW002

Test Report

Download: PDF
FCCID_4194314

                                           FCC PART 15.231

                                              TEST REPORT
                                                             For

                               Polygroup Trading Limited
                  Unit 606, Fairmont House, 8 Cotton Tree Drive, Central, Hong Kong


                                         FCC ID: 2APJZ-CW002


            Report Type:                                      Product Type:
            Original Report                                   Re mote Controller



                   Report Number:           RSZ181205810-00


                        Report Date:        2018-12-25

                                            Simon Wang

                       Reviewed By:         RF Engineer

                                            Bay Area Compliance Laboratories Corp. (Shenzhen)
                                            6/F., West Wing, Third Phase of Wanli Industrial
                        Prepared By:        Building, Shihua Road, Futian Free Trade Zone,
                                            Shenzhen, Guangdong, China
                                            Tel: +86-755-33320018
                                            Fax: +86-755-33320008
                                            www.baclcorp.com.cn




Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any
agency of the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked
with an asterisk “*”


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                          Report No.: RSZ181205810-00




                                                         TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................3
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  SPECIAL ACCESSORIES .................................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL I/O CABLE..................................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
TEST EQUIPMENT LIST AND DETAILS ...............................................................................................................8
FCC §15.203 - ANTENNA REQUIREMENT.............................................................................................................9
  APPLICABLE STANDARD ..............................................................................................................................................9
  ANTENNA CONNECTOR CONSTRUCTION ......................................................................................................................9
FCC §15.205, §15.209, §15.231 (B) - RADIATED EMISSIONS .............................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
  EUT SETUP ................................................................................................................................................................10
  EMI TEST RECEIVER SETUP .......................................................................................................................................11
  TEST PROCEDURE ......................................................................................................................................................11
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................12
  TEST RESULTS SUMMARY ..........................................................................................................................................12
  TEST DATA ................................................................................................................................................................12
FCC §15.231(A) (2) - DEACTIVATION TESTING.................................................................................................18
  APPLICABLE STANDARD ............................................................................................................................................18
  TEST PROCEDURE ......................................................................................................................................................18
  TEST DATA ................................................................................................................................................................18
FCC §15.231(C) – 20 DB EMISSION BANDWIDTH TESTING ...........................................................................20
  APPLICABLE STANDARD ............................................................................................................................................20
  TEST PROCEDURE ......................................................................................................................................................20
  TEST DATA ................................................................................................................................................................20




FCC Part 15.231                                                                                                                                         Page 2 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ181205810-00

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Polygroup Trading Limited’s product, model number: PDT-002-29V (FCC ID: 2APJZ-CW002) or
the "EUT" in this report was a Remote Controller, which was measured approximately:8.1 cm (L) * 4.1 cm
(W) * 2.0 cm (H), rated with input voltage: DC 3.0 V from battery.

*All measurement and test data in this report was gathered from production sample serial number: 181205810
  (Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2018-12-05.


Objective
This test report is prepared on behalf of Polygroup Trading Limited. All the test measurements were
performed according to the measurement procedure described in ANSI C63.10 - 2013.

The tests were performed in order to determine compliance with FCC Part 15, Subpart C, section 15.203,
15.205, 15.209, 15.35(c) and 15.231 rules.


Related Submittal(s)/Grant(s)
No Related Submission.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10 - 2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.
All emissions measurement was performed at Bay Area Compliance Laboratories Corp. (Shenzhen). The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.


Measurement Uncertainty

                                  Item                                         Uncertainty

                                             30MHz~1 GHz                         ±5.91 dB
           Radiated emission
                                             Above 1 GHz                         ±4.92 dB
                  AC Power Lines Conducted Emissions                              ±1.95dB
                          Occupied Bandwidth                                     ±0.5 kHz
                               Temperature                                        ±1.0 ℃
                                Humidity                                           ±6 ℅




FCC Part 15.231                                                                                   Page 3 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ181205810-00

Test Facility
The test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located on
the 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No.: 342867, the FCC Designation No.: CN1221.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062B.




FCC Part 15.231                                                                              Page 4 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                     Report No.: RSZ181205810-00

SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing by manufacturer.
Operating frequency:434MHz.


Special Accessories
No special accessories was used


Equipment Modifications
No modification was made to the EUT.


Support Equipment List and Details


     Manufacturer             Description                Model             Serial Number

            /                         /                       /                   /


External I/O Cable

                  Cable Description                 Length (m)    From / Port          To

                          /                               /            /                /




FCC Part 15.231                                                                        Page 5 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                Report No.: RSZ181205810-00

Block Diagram of Test Setup




                                                                              1.0 Meter
                                                 EUT




                  Non-Conductive Table
                  80/150 cm above Ground Plane

                                                    1.5 Meters




FCC Part 15.231                                                                           Page 6 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ181205810-00


SUMMARY OF TEST RESULTS

                        FCC Rules                           Description of Test              Result

                         §15.203                           Antenna Requirement             Compliance

                        §15.207 (a)                        Conducted Emissions            Not Applicable

               §15.205, §15.209, §15.231(b)                 Radiated Emissions             Compliance

                        §15.231 (c)                     20dB Emission Bandwidth            Compliance

                      §15.231 (a) (2)                          Deactivation                Compliance


Note: The battery need be pulled out from EUT while it’s been charging.




FCC Part 15.231                                                                                    Page 7 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                   Report No.: RSZ181205810-00


TEST EQUIPMENT LIST AND DETAILS

                                                                         Serial        Calibration   Calibration
      Manufacturer              Description             Model
                                                                        Number            Date        Due Date
                                               Radiated Emission Test
       A.H. System             Horn Antenna          SAS-200/571           135          2018-09-01   2021-08-31
    Rohde & Schwarz           Signal Analyzer           FSEM         845987/005         2018-06-23   2019-06-23
      COM-POWER                Pre-amplifier            PA-122           181919         2018-11-12   2019-11-12
   Sonoma instrument             Amplifier              310N             186238         2018-11-12   2019-11-12
      Sunol Sciences        Broadband Antenna            JB1            A040904-1       2017-12-22   2020-12-21
    Rohde & Schwarz          EMI Test Receiver          ESCI          101120            2018-01-11   2019-01-11
     Rohde Schwarz           EMI Test Receiver           ESR       1316.3003K03         2018-07-11   2019-07-11
       Ducommun                                       UFA147A-      MFR64639
                                 RF Cable                                               2018-08-01   2019-02-01
      technologies                                   2362-100100    231029-003
       Ducommun
                                 RF Cable              104PEA           218124002       2018-11-12   2019-11-12
      technologies
       Ducommun
                                 RF Cable              RG-214              1            2018-11-19   2019-05-21
      technologies
       Ducommun
                                 RF Cable              RG-214               2           2018-11-12   2019-11-12
      technologies

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
 been performed in accordance to requirements that traceable to National Primary Standards and International
 System of Units (SI).




FCC Part 15.231                                                                                      Page 8 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ181205810-00

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.


Antenna Connector Construction
The EUT has one internal antenna arrangement, which used a unique coupling to this product. And the
antenna is 0dBi; fulfill the requirement of this section. Please refer to EUT photos.
Result: Compliant.




FCC Part 15.231                                                                                Page 9 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ181205810-00

FCC §15.205, §15.209, §15.231 (b) - RADIATED EMISSIONS
Applicable Standard
FCC §15.205, §15.209, §15.231 (b)
According to FCC §15.231(b), the field strength of emissions from intentional radiators operated under
this section shall not exceed the following:

           Fundamental frequency             Field Strength of             Field Strength of spurious
                                          Fundamental (Microvolts            emissions ((Microvolts
                 (MHz)                            /meter)                            /meter)
                  40.66-40.70                        2250                              225
                     70-130                          1250                              125
                    130-174                     1250 to 3750**                    125 to 375**
                    174-260                          3750                              375
                    260-470                    3750 to 12500**                   375 to 1250**
                  Above 470                         12500                             1250

       *Linear interpolations.

The above field strength limits are specified at a distance of 3-meters the tighter limits apply at the band
edges.

EUT Setup
Below 1 GHz:




FCC Part 15.231                                                                                  Page 10 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ181205810-00

Above 1 GHz:




The radiated emission tests were performed in the 3 meters test site, using the setup accordance with the
ANSI C63.10 - 2013. The specification used was the FCC 15 § 15.209, 15.205 and 15.231.


EMI Test Receiver Setup
The system was investigated from 30 MHz to 5 GHz.

During the radiated emission test, the test receiver was set with the following configurations:

               Frequency Range            RBW          Video B/W        IF B/W       Measurement

              30MHz – 1000 MHz           100 kHz        300 kHz        120 kHz            QP
                  Above 1 GHz             1 MHz          3 MHz             /              PK


Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.
All final data was recorded in the Quasi-peak detection mode from 30MHz to 1GHz, Peak and average
detection mode above 1 GHz.




FCC Part 15.231                                                                                   Page 11 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ181205810-00

Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Loss and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:
        Corrected Amplitude = Meter Reading + Antenna Loss + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 5.8 dB means the emission is 5.8 dB below the limit. The equation for
margin calculation is as follows:
        Margin = Limit –Corrected Amplitude


Test Results Summary
According to the data in the following table, the EUT complied with the FCC §15.205, §15.209, §15.231
(b)
Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                           Lm  U(Lm ) ≤ Llim  Ucispr

In BACL, U(Lm ) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


Test Data
 Environmental Conditions

            Temperature:               25~26 ℃
       Relative Humidity:              50~55 %
          ATM Pressure:             100.9~101.1 kPa

      The testing was performed by Leo Huang on 2018-12-11 and 2018-12-25

      Test mode: Transmitting




FCC Part 15.231                                                                                     Page 12 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                          Report No.: RSZ181205810-00


                                                                       Fundamental
                                       80


                                       70



                                       60
                                                                               Electric Field Strength QP-3m

                                       50
                     Level in dB¦ÌV/




                                       40


                                       30


                                       20


                                       10


                                        0
                                        30M        50   60   80 100M              200      300      400   500           800   1G
                                                                        Frequency in Hz




             Corrected                                       Antenna          Turntable Correction
Frequency                                       Detector             Antenna                         Limit                                  Margin
             Amplitude                                        Height           Position  Factor
  (MHz)                                       (PK/QP/Ave.)           Polarity                      (dBμV/m)                                  (dB)
             (dBμV/m)                                          (cm)            (degree)  (dB/m)
30.356939         14.53                           QP           325.0          V               0.0               -7.9               40.00     25.47
216.999375        33.85                           QP           142.0          H              97.0               -13.9              46.00     12.15
325.508375        28.62                           QP           104.0          H              91.0               -10.7              46.00     17.38
680.056500        21.66                           QP           186.0          V             152.0               -2.1               46.00     24.34
839.515625        29.84                           QP           392.0          V             293.0               5.9                46.00     16.16
950.472875        31.16                           QP           296.0          H             261.0               9.9                46.00     14.84




FCC Part 15.231                                                                                                                       Page 13 of 21


   Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ181205810-00




                Receiver                Rx Antenna                        FCC Part 15.231(b)
                                                   Corrected Corrected
Frequency                     Turntable
          Reading    Detector                       Factor Amplitude Limit
  (MHz)                        Degree Height Polar                           Margin
                                                                                         Comment
          (dBμV) (PK/QP/Ave.)           (cm) (H/V) (dB/m) (dBμV/m) (dBμV/m)    (dB)

  434           85.12       PK          1       100       H     -8.91     76.21       100.8       24.59     Fundamental
  434           83.19       PK         340      150       V     -8.91     74.28       100.8       26.52     Fundamental
  1302          55.98       PK         197      2.3       H     -2.98     53.00       80.8        27.80       Spurious
  1302          51.28       PK         197      2.3       V     -2.98     48.30       80.8        32.50       Spurious
  2170          50.80       PK         54       1.2       H     -0.76     50.04       80.8        30.76       Spurious
  2170          48.89       PK         54       1.2       V     -0.76     48.13       80.8        32.67       Spurious



                                              Field Strength of Average

                                               Duty Cycle                            FCC Part 15.231(b)
                       Peak                                   Corrected
   Frequency                        Polar      Correction
                    Measurement                               Ampitude
     (MHz)                          (H/V)       Factor                       Limit            Margin
                     (dBµV/m)                                 (dBµV/m)                                    Comment
                                                 (dB)                      (dBµV/m)            (dB)

         434            76.21         H           -5.86         70.35         80.8            10.45    Fundamental

         434            74.28         V           -5.86         68.42         80.8            12.38    Fundamental

         1302           53.00         H           -5.86         47.14         60.8            13.66       Spurious

         1302           48.30         V           -5.86         42.44         60.8            18.36       Spurious

         2170           50.04         H           -5.86         44.18         60.8            16.62       Spurious

         2170           48.13         V           -5.86         42.27         60.8            18.53       Spurious


   Note:

   Corrected Amplitude = Corrected Factor + Reading
   Corrected Factor = Antenna factor (Rx) + cable loss – amplifier factor
   Margin = Limit - Corr. Amplitude
   Ave. = PK + 20*log(Duty Cycle)
   Duty cycle factor = 20*log(Ton/Tp) = 20*log(50.94/100) = -5.86 dB
   Where Ton=28*1.26+15.66=50.94 ms, Tp=100 ms




   FCC Part 15.231                                                                                     Page 14 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                   Report No.: RSZ181205810-00

                                                                 Duty Cycle
                                                                     RBW 100 kHz
                                                                    * VBW 300 kHz
                         Ref   107 dBµV          * Att   15 dB       SWT 400 ms


                         100
                                                                                       A
                                                                                      SGL
                  1 PK
                         90
                  MAXH                                                                TRG


                         80                                                           TDF


                         70                                                           PS



                         60
                                 TRG 55.3 dBµV

                         50                                                           3DB
                                                                                      AC


                         40



                         30



                         20



                         10

                         Center 434 MHz                          40 ms/




                  EUT
                  Date: 15.DEC.2018       18:17:58




                                                                     RBW 100 kHz
                                                                    * VBW 300 kHz
                         Ref   107 dBµV          * Att   15 dB       SWT 100 ms


                         100
                                                                                       A
                                                                                      SGL
                  1 PK
                         90
                  MAXH                                                                TRG


                         80                                                           TDF


                         70                                                           PS



                         60
                                 TRG 55.3 dBµV

                         50                                                           3DB
                                                                                      AC


                         40



                         30



                         20



                         10

                         Center 434 MHz                          10 ms/




                  EUT
                  Date: 15.DEC.2018       18:19:26




FCC Part 15.231                                                                                      Page 15 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                       Report No.: RSZ181205810-00


                                                                      RBW 100 kHz    Delta 1 [T1 ]
                                                                     * VBW 300 kHz               0.62 dB
                         Ref   107 dBµV            * Att   15 dB      SWT 30 ms             15.660000 ms

                                                                                     Marker 1 [T1 ]
                         100                                                                   23.14 dBµV
                                                                                           -80.000000 µs     A
                                                                                                            SGL
                  1 PK
                         90
                  MAXH                                                                                      TRG


                         80                                                                                 TDF


                         70                                                                                 PS



                         60
                                   TRG 55.3 dBµV

                         50                                                                                 3DB
                                                                                                            AC


                         40



                         30
                               1                                           1

                         20



                         10

                         Center 434 MHz                            3 ms/




                  EUT
                  Date: 15.DEC.2018         18:21:53




                                                                      RBW 100 kHz    Delta 1 [T1 ]
                                                                     * VBW 300 kHz               1.00 dB
                         Ref   107 dBµV            * Att   15 dB      SWT 30 ms              1.260000 ms

                                                                                     Marker 1 [T1 ]
                         100                                                                   24.33 dBµV
                                                                                            26.080000 ms     A
                                                                                                            SGL
                  1 PK
                         90
                  MAXH                                                                                      TRG


                         80                                                                                 TDF


                         70                                                                                 PS



                         60
                                   TRG 55.3 dBµV

                         50                                                                                 3DB
                                                                                                            AC


                         40



                         30
                                                                                                    1   1


                         20



                         10

                         Center 434 MHz                            3 ms/




                  EUT
                  Date: 15.DEC.2018         18:22:20




Note: Test with normal use sample for Duty cycle.

FCC Part 15.231                                                                                                          Page 16 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                 Report No.: RSZ181205810-00


                                           Pre-scan-Horizontal




                                            Pre-scan - Vertical




FCC Part 15.231                                                                    Page 17 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ181205810-00


FCC §15.231(a) (2) - DEACTIVATION TESTING
Applicable Standard
Per FCC §15.231(a) (2), a transmitter activated automatically shall cease transmission within 5 seconds
after activation.


Test Procedure
1.   Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the
     spectrum analyzer.
2.   Set center frequency of spectrum analyzer=operating frequency.
3.   Set the spectrum analyzer as RBW=100kHz/ VBW=300kHz/ Span=0Hz.
4.   Repeat above procedures until all frequency measured was complete.


Test Data
 Environmental Conditions

            Temperature:               25 ℃
       Relative Humidity:              53 %
          ATM Pressure:              100.1 kPa

     The testing was performed by Tracy Hu on 2018-12-10.

Test mode: Transmitting

Test Result: Compliant. This product will cease transmission within 5 seconds after activation. Please
refer to following plots.




FCC Part 15.231                                                                              Page 18 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)   Report No.: RSZ181205810-00




FCC Part 15.231                                                      Page 19 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                       Report No.: RSZ181205810-00

FCC §15.231(c) – 20 dB EMISSION BANDWIDTH TESTING
Applicable Standard
Per 15.231(c), The bandwidth of the emission shall be no wider than 0.25% of the center frequency for
devices operating above 70 MHz and below 900 MHz. Bandwidth is determined at the points 20 dB down
from the modulated carrier.


Test Procedure
With the EUT’s antenna attached, the waveforzm was received by the test antenna which was connected to
the spectrum analyzer, plot the 20 dB bandwidth.


Test Data
 Environmental Conditions

            Temperature:               25 ℃
       Relative Humidity:              53 %
          ATM Pressure:              100.1 kPa

     The testing was performed by Tracy Hu on 2018-12-10.

    Test Mode: Transmitting

    Please refer to following table and plots.




FCC Part 15.231                                                                          Page 20 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                   Report No.: RSZ181205810-00

         Channel Frequency                20 dB Emission Bandwidth                         <Limit
                                                                                                                Result
              (MHz )                               (kHz)                                   (kHz)
                  434                                      2.2                               1085                Pass




                                                20 dB Emission Bandwidth
                                                                    * RBW 100 Hz   Delta 1 [T1 ]
                                                                     VBW 300 Hz               -1.61 dB
                         Ref   89 dBµV          * Att   10 dB        SWT 12 s           2.200000000 kHz

                                                                                   Marker 1 [T1 ]
                                                                                             44.88 dBµV
                         80                                                           434.002600000 MHz    A

                  1 PK
                  MAXH   70

                                 D1 64.5 dBµV
                                                                                                          TDF
                         60


                                                                                                          PS
                         50
                                                                    1
                                                                        1
                                    D2 44.5 dBµV
                         40


                                                                                                          3DB
                         30                                                                               AC



                         20



                         10



                         0


                         -10

                         Center 434 MHz                         10 kHz/                    Span 100 kHz




                  EUT
                  Date: 10.DEC.2018       15:21:08




                                          ***** END OF REPORT *****




FCC Part 15.231                                                                                                      Page 21 of 21



Document Created: 2019-03-07 16:19:48
Document Modified: 2019-03-07 16:19:48

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC