MPE

FCC ID: 2APJVOPRHF

RF Exposure Info

Download: PDF
FCCID_4304915

HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313




                                  Electromagnetic Compatibility
                                         MPE Calculation
                                                   For the

                                    Openpath Security Inc.
                           Model Smart Reader & Mullion Smart Reader


                                MET Report: EMCS101883-MPE HF

                                               May 20, 2019


                                                Prepared For:

                                         Openpath Security Inc.
                                         5839 Green Valley Cir.
                                         Culver City, CA 90230




                                                                                                  Prepared By:
                                                                                      MET Laboratories, Inc.
                                                                                        914 W. Patapsco Ave.
                                                                                        Baltimore, MD 21230




                           Maryland   | California | Texas | China | Korea | Taiwan
                                               www.metlabs.com


Openpath Security Inc.                                                               Electromagnetic Compatibility
Model Smart Reader & Mullion Smart Reader                                                        MPE Calculation




                                  Electromagnetic Compatibility
                                         MPE Calculation
                                                 For the

                                   Openpath Security Inc.
                          Model Smart Reader & Mullion Smart Reader




                                MET Report: EMCS101883-MPE HF




         James Borrott, Project Engineer                                         Jennifer Warnell
         Electromagnetic Compatibility Lab                                       Documentation Department




MET Report: EMCS101883-MPE HF                  © 2019, Eurofins MET Labs, Inc.                         Page 2 of 4

                          Maryland    | California | Texas | China | Korea | Taiwan
                                               www.metlabs.com


Openpath Security Inc.                                                                    Electromagnetic Compatibility
Model Smart Reader & Mullion Smart Reader                                                             MPE Calculation


Electromagnetic Compatibility Criteria for Intentional Radiators

         RF Exposure

Purpose:                               Co-location of two modules, Taiyo Yuden Model EYSGJN (FCC ID:
                                       RYYEYSGJN) and Rigado BMD-340 (FCC ID: 2AA9B10).


RF Exposure Requirements:              §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions
                                       of this section shall be operated in a manner that ensures that the public is
                                       not exposed to radio frequency energy levels in excess of the Commission’s
                                       guidelines.

RF Radiation Exposure Limit:           §1.1310: As specified in this section, the Maximum Permissible Exposure
                                       (MPE) Limit shall be used to evaluate the environmental impact of human
                                       exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b),
                                       except in the case of portable devices which shall be evaluated according to
                                       the provisions of Sec. 2.1093 of this chapter.


                            Limits for General Population/Uncontrolled Exposure
 Frequency range      Electric field strength       Magnetic field strength       Power density    Averaging time
     (MHz)                    (V/m)                        (A/m)                   (mW/cm2)          (minutes)
      0.3-1.34                  614                           1.63                     *100                30
                                                                                               2
      1.34-30                   824/f                         2.19/f                  *180/f               30
      30-300                    27.5                          0.073                    0.2                 30
     300-1,500                    --                            --                    f/1500               30
  1,500-100,000                   --                            --                     1.0                 30

Limits for Maximum Permissible Exposure (MPE)




MET Report: EMCS101883-MPE HF                       © 2019, Eurofins MET Labs, Inc.                         Page 3 of 4

                          Maryland      | California | Texas | China | Korea | Taiwan
                                                 www.metlabs.com


Openpath Security Inc.                                                                   Electromagnetic Compatibility
Model Smart Reader & Mullion Smart Reader                                                            MPE Calculation


Individual Modules

                       Taiyo Yuden Model EYSGJN                                         2402-2480 MHz
                               Rigado BMD-340                                           2402-2480 MHz
                        Mullion Smart Reader HF                                              13.56MHz


Co-Located Modules


              Module 1                                Module 2                                Module 3
  Taiyo Yuden Model EYSGJN                          Rigado BMD-340                     Mullion Smart Reader

Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneously
transmitting antennas incorporated in a host device is ≤ 1.0
MPE ratio = MPE / MPE Limit @ Frequency

Total Percentage of Exposure: 0.08%

S=PG/4.πR2
P= Power to antenna (mW)
G= Antenna gain (numeric)
R= Distance (cm)

                                   Rigado BMD-340 FCC ID: 2AA9B10
                 Antenna Gain             Conducted Power         Evaluation        Power       MPE
Frequency                                                                                                   Percent
                                                                   Distance        Density      Limit
  (MHz)         (dBi)      (numeric)        (dBm)      (mW)                                                  Limit
                                                                    (cm)          (mW/cm2)    (mW/cm2)
   2402          -1             0.79        4.579       2.87          20           0.00045       1.0         0.045


                        Taiyo Yuden Model EYSGJN FCC ID: RYYEYSGJN
                 Antenna Gain             Conducted Power         Evaluation        Power       MPE
Frequency                                                                                                   Percent
                                                                   Distance        Density      Limit
  (MHz)         (dBi)      (numeric)        (dBm)      (mW)                                                  Limit
                                                                    (cm)          (mW/cm2)    (mW/cm2)
   2402         -1.5            0.71        3.90        2.455         20           0.00035       1.0         0.035


                                                  Smart Reader HF
                                EIRP                  Evaluation          Power
 Frequency                                                                             MPE Limit         Percent
                                                       Distance           Density
   (MHz)              (dBm)             (mW)                                           (mW/cm2)           Limit
                                                        (cm)            (mW/cm2)
    13.56              -52.4           0.000006           20             1.2 x 10-9       0.98             <0.01




MET Report: EMCS101883-MPE HF                        © 2019, Eurofins MET Labs, Inc.                       Page 4 of 4