Test Report

FCC ID: 2APDTTS-A05BT-ANC

Test Report

Download: PDF
FCCID_4487090

                                            FCC Part 15.247
                                              TEST REPORT
                                                           For

       IONE ELECTRONIC TECHNOLOGY CO., LTD. TAIWAN BRANCH
8F-2, #75, sec 1, Hsin Tai Wu Rd., Hsi Chih District, New Taipei City, Taiwan, R.O.C.(Far East World Center-Bldg. A)



                                FCC ID: 2APDTTS-A05BT-ANC


          Report Type                                    Original Report


          Product Name:                                  TUNE IN - Streaming

          Model Name:                                    TS-A05BT-ANC

          Report Number :                                RXZ190624003-00A

          Report Date :                                  2019/10/21

          Reviewed By :                                  Zeus Chen
          Prepared By:
          Bay Area Compliance Laboratories Corp.(Linkou Laboratory)
          No. 6, Wende 2Rd., Guishan Dist., Taoyuan City 33382, Taiwan (R.O.C.)
          Tel: +886 (3)3961072; Fax: +886 (3) 3961027
          www.bacl.com.tw
         Note: This test report is prepared for the customer shown above and for the device described herein. It
         may not be duplicated or used in part without prior written consent from Bay Area Compliance
         Laboratories Corp. (Linkou Laboratory)


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                   Report No.: RXZ190624003-00A




                                                  Revision History
     Revision                     Report Number                Issue Date           Description

        1.0                     RXZ190624003-00A              2019/10/21           Original Report




                                                                                Page 2 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                                                                Report No.: RXZ190624003-00A


                                                                         TABLE OF CONTENTS
1       GENERAL INFORMATION ....................................................................................................................................... 5
     1.1    PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...................................................................................... 5
     1.2    OPERATION CONDITION OF EUT ............................................................................................................................ 5
     1.3    OBJECTIVE AND TEST METHODOLOGY ..................................................................................................................... 6
     1.4    MEASUREMENT UNCERTAINTY .............................................................................................................................. 6
     1.5    TEST FACILITY..................................................................................................................................................... 6
2       SYSTEM TEST CONFIGURATION ............................................................................................................................. 7
     2.1     TEST CHANNELS AND DESCRIPTION OF WORST TEST CONFIGURATION........................................................................... 7
     2.2     SUPPORT EQUIPMENT LIST AND EXTERNAL CABLE LIST ............................................................................................... 7
     2.3     BLOCK DIAGRAM OF TEST SETUP ........................................................................................................................... 8
     2.4     DUTY CYCLE....................................................................................................................................................... 8
3        SUMMARY OF TEST RESULTS ................................................................................................................................. 9
4       FCC§15.247(I), §1.1307, § 2.1093 - RF EXPOSURE ............................................................................................... 10
     4.1    APPLICABLE STANDARD ...................................................................................................................................... 10
     4.2    RF EXPOSURE EVALUATION RESULT...................................................................................................................... 10
5       FCC §15.203 - ANTENNA REQUIREMENTS ........................................................................................................... 11
     5.1     APPLICABLE STANDARD ...................................................................................................................................... 11
     5.2     ANTENNA LIST AND DETAILS ............................................................................................................................... 11
6       FCC §15.207 - AC LINE CONDUCTED EMISSIONS ................................................................................................. 12
     6.1     APPLICABLE STANDARD ...................................................................................................................................... 12
     6.2     EUT SETUP AND TEST PROCEDURE....................................................................................................................... 12
     6.3     TEST EQUIPMENT LIST AND DETAILS ..................................................................................................................... 13
     6.4     TEST ENVIRONMENTAL CONDITIONS ..................................................................................................................... 13
     6.5     TEST DATA AND TEST PLOT ................................................................................................................................. 14
7       FCC §15.209, §15.205, §15.247(D) – SPURIOUS EMISSIONS ............................................................................... 16
     7.1     APPLICABLE STANDARD ...................................................................................................................................... 16
     7.2     EUT SETUP AND TEST PROCEDURE....................................................................................................................... 18
     7.3     TEST EQUIPMENT LIST AND DETAILS ..................................................................................................................... 19
     7.4     TEST ENVIRONMENTAL CONDITIONS ..................................................................................................................... 19
     7.5     TEST RESULT .................................................................................................................................................... 20
8       FCC §15.247(A)(2) – 6 DB EMISSION BANDWIDTH ............................................................................................. 24
     8.1     APPLICABLE STANDARD ...................................................................................................................................... 24
     8.2     TEST PROCEDURE.............................................................................................................................................. 24
     8.3     TEST EQUIPMENT LIST AND DETAILS ..................................................................................................................... 24
     8.4     TEST ENVIRONMENTAL CONDITIONS ..................................................................................................................... 24
     8.5     TEST RESULTS .................................................................................................................................................. 25
9       FCC §15.247(B) (3) – MAXIMUM OUTPUT POWER ............................................................................................. 26
     9.1     APPLICABLE STANDARD ...................................................................................................................................... 26
     9.2     TEST PROCEDURE.............................................................................................................................................. 26
     9.3     TEST EQUIPMENT LIST AND DETAILS ..................................................................................................................... 26
     9.4     TEST ENVIRONMENTAL CONDITIONS ..................................................................................................................... 26
     9.5     TEST RESULTS .................................................................................................................................................. 27
10     FCC §15.247(D) – 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE ............................................................... 28
     10.1   APPLICABLE STANDARD ...................................................................................................................................... 28
     10.2   TEST PROCEDURE.............................................................................................................................................. 28
     10.3   TEST EQUIPMENT LIST AND DETAILS ..................................................................................................................... 29
     10.4   TEST ENVIRONMENTAL CONDITIONS ..................................................................................................................... 29
     10.5   TEST RESULTS .................................................................................................................................................. 30
11       FCC §15.247(E) – POWER SPECTRAL DENSITY ..................................................................................................... 31


                                                                                                                                                Page 3 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                                                            Report No.: RXZ190624003-00A

  11.1     APPLICABLE STANDARD ...................................................................................................................................... 31
  11.2     TEST PROCEDURE.............................................................................................................................................. 31
  11.3     TEST EQUIPMENT LIST AND DETAILS ..................................................................................................................... 31
  11.4     TEST ENVIRONMENTAL CONDITIONS ..................................................................................................................... 31
  11.5     TEST RESULTS .................................................................................................................................................. 32




                                                                                                                                             Page 4 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                                    Report No.: RXZ190624003-00A


1     General Information

1.1     Product Description for Equipment under Test (EUT)

                                                             IONE ELECTRONIC TECHNOLOGY CO., LTD. TAIWAN BRANCH
Applicant                                                    8F-2, #75, sec 1, Hsin Tai Wu Rd., Hsi Chih District, New Taipei City,
                                                             Taiwan, R.O.C.(Far East World Center-Bldg. A)


                                                             IONE ELECTRONIC TECHNOLOGY CO., LTD. TAIWAN BRANCH
Manufacturer                                                 8F-2, #75, sec 1, Hsin Tai Wu Rd., Hsi Chih District, New Taipei City,
                                                             Taiwan, R.O.C.(Far East World Center-Bldg. A)

Product (Equipment)                                          TUNE IN - Streaming
Model Name                                                   TS-A05BT-ANC
Frequency Range                                              2402 - 2480 MHz
Number of Channels                                           40 Channels
Output Power                                                 -2.22 dBm (0.0006 W)
Modulation Type                                              GFSK
Related Submittal(s)/Grant(s)                                FCC Part 15.247 DSS with FCC ID : 2APDTTS-A05BT-ANC
Received Date                                                Jun. 24, 2019
Date of Test                                                 July. 12, 2019 ~ Oct 21, 2019
*All measurement and test data in this report was gathered from production sample serial number: 190624003(Assigned by BACL, LinKou).



1.2     Operation Condition of EUT


                                                      AC 120 V/60 Hz
                                                         Adapter
                                                         By Power Cord.

                                                      DC Type
Power Operation                                          DC Power Supply: 5Vdc to connector port
(Voltage Range)
                                                         Battery
                                                         External from USB Cable 5Vdc
                                                         External DC Adapter

                                                      Host System




                                                                                                                   Page 5 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                           Report No.: RXZ190624003-00A


1.3    Objective and Test Methodology
The Objective of this Test Report was to document the compliance of the IONE ELECTRONIC TECHNOLOGY CO., LTD.
TAIWAN BRANCH. Appliance (Model: TS-A05BT-ANC) to the requirements of the following Standards:

-Part 2, Subpart J, Part 15, Subparts A and C, section 15.247 of the Federal Communication Commission’s rules.


- ANSI C63.10-2013 of t American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.


-KDB 558074 D01 15.247 Meas Guidance v05r02.


1.4    Measurement Uncertainty
                         Parameter                                             Expanded Measurement uncertainty

            RF output power with Power Meter                                                   ± 0.55 dB
                Occupied Channel Bandwidth                                                     ± 4.54 Hz
              RF Conducted test with Spectrum                                                  ± 1.45 dB
             AC Power Line Conducted Emission                                                  ± 2.66 dB
                    Radiated Below 1G                                                          ± 3.57 dB
                 Radiated Above 1G-18G                                                         ± 4.29 dB
                Radiated Above 18G-40G                                                         ± 4.67 dB


1.5    Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Linkou) to collect test data is located on

   No.6, Wende 2Rd., Guishan Dist., Taoyuan City 33382, Taiwan (R.O.C.).



The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL)
database. The FCC Registration No.: 0027578244. Designation No.: TW3546. The Test Firm Registration No.: 181430.




                                                                                                           Page 6 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                              Report No.: RXZ190624003-00A


2        System Test Configuration

2.1       Test Channels and Description of Worst Test Configuration
The system was configured for testing in testing mode which was provided by manufacturer.

No special accessory, No modification was made to the EUT and No special equipment used during test.

For BLE, there are totally 40 channels.
                                               Frequency                                                           Frequency
            Channel                                                                Channel
                                                 (MHz)                                                               (MHz)
                0                                2402                                   20                           2442
                1                                2404                                   --                                --
                2                                2406                                   --                                --
                3                                2408                                   37                           2476
               --                                  --                                   38                           2478
               19                                2440                                   39                           2480

For BLE: Channel 0, 19 and 39 were tested.

The worst-case data rates are determined to be as follows for each mode based upon investigation by measuring the Peak
power and PSD across all date rates bandwidths, and modulations.



                                                Modulation Used for Conformance Test
          Configuration                 NTX                        Data Rate                                Worst Data Rate
            BLE mode                     1                      125 kbps-1 Mbps                                  1 Mbps


                                                        Worst Case of Power Setting
            EUT Exercise Software                                                            QRCT3
          Configuration                 NTX                   Low CH                         Mid CH                   High CH
            BLE mode                     1                    Default                        Default                      Default


2.2       Support Equipment List and External Cable List

    No.                   Description                          Manufacturer                              Model Number
     A                 Notebook PC                                 DELL                                  Latitude E6410
     B                     Adapter                                  MI                                    A1718 (Apple)


No.         Cable Description                Shielding Type                Length (m)                      From                     To
 1              USB Cable                    Non-Shielded                         1.0                      EUT                 Adapter
 2              USB Cable                    Non-Shielded                         1.0                      EUT                   NB




                                                                                                           Page 7 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                        Report No.: RXZ190624003-00A


2.3       Block Diagram of Test Setup
                          Conduction                                                         Radiation




      -




2.4       Duty Cycle

According to KDB 558074 D01 15.247 Meas Guidance v05:


All measurements are to be performed with the EUT transmitting at 100% duty cycle at its maximum power control level; however, if

100% duty cycle cannot be achieved, measurements of duty cycle, x, and maximum power transmission duration, T, are required for

each tested mode of operation.

          Configuration               On Time (ms)             Period (ms)             Duty Cycle (%)          Duty Factor (dB)

           BLE mode                          0.384                 0.626                    61.00                      2.15


                           BLE mode                                                                 -




                                                                                                    -




*Note: Duty Factor = 10*log (1/Duty cycle)



                                                                                                        Page 8 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                  Report No.: RXZ190624003-00A


3    Summary of Test Results


             FCC Rules                                        Description of Test                          Result

    §15.247(i), §1.1307, § 2.1093                                RF Exposure                            Compliance

              §15.203                                        Antenna Requirement                        Compliance

             §15.207(a)                                 AC Line Conducted Emissions                     Compliance

    §15.205, §15.209, §15.247(d)                              Spurious Emissions                        Compliance

           §15.247(a)(2)                                    6 dB Emission Bandwidth                     Compliance

           §15.247(b)(3)                               Maximum Peak Output Power                        Compliance

             §15.247(d)                         100 kHz Bandwidth of Frequency Band Edge                Compliance

             §15.247(e)                                     Power Spectral Density                      Compliance




                                                                                               Page 9 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                  Report No.: RXZ190624003-00A


4     FCC§15.247(i), §1.1307, § 2.1093 - RF Exposure

4.1    Applicable Standard
According to FCC §2.1093 and §1.1307(b) (1), systems operating under the provisions of this section shall be operated in a
manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline.


According to KDB 447498 D01 General RF Exposure Guidance v06
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined
by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
1. f(GHz) is the RF channel transmit frequency in GHz.
2. Power and distance are rounded to the nearest mW and mm before calculation.
3. The result is rounded to one decimal place for comparison.
4. 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below


The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm,
a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion.



4.2    RF Exposure Evaluation Result

RF Exposure Evaluation:


                   Tunp-up Power                                                                   Extremity SAR
 Frequency                                   Evaluation Distrance         SAR Excluion
                                                                                                   Exclusion Limit
   (MHz)                                            (mm)                     Result
                 (dBm)          (mW)                                                                  (1g SAR)

 2402-2480        -1.00         0.794                   5                      0.2528                    7.5

Result: SAR evaluation is not necessary.




                                                                                               Page 10 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                    Report No.: RXZ190624003-00A


5     FCC §15.203 - Antenna Requirements

5.1    Applicable Standard

According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by
the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that
uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this
section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the user of a
standard antenna jack or electrical connector is prohibited.

And according to FCC 47 CFR section 15.247 (b), if the transmitting antennas of directional gain greater than 6dBi are used,
the power shall be reduced by the amount in dB that the directional gain of the antenna does not exceed 6dBi



5.2    Antenna List and Details

       Brand                     Antenna Type                        Antenna Gain                          Result

      YAGEO                       Chip Antenna                          1.69 dBi                         Compliance

The EUT has an internal antenna arrangement, which was permanently attached, fulfill the requirement of this section.




                                                                                                  Page 11 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                              Report No.: RXZ190624003-00A


6     FCC §15.207 - AC Line Conducted Emissions

6.1    Applicable Standard

According to FCC §15.207 and §15.407(b)(6),

For an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency
voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30
MHz shall not exceed the limits in the following table, as measured using a 50 µH/50 ohms line impedance stabilization
network (LISN). Compliance with the provisions of this paragraph shall be based on the measurement of the radio
frequency voltage between each power line and ground at the power terminal. The lower limit applies at the boundary
between the frequencies ranges.


                                                                                Conducted Limit (dBuV)
            Frequency (MHz)
                                                             Quasi-Peak                                       Average
                                                                       Note 1
                0.15-0.5                                    66 to 56                                        56 to 46 Note 2
                  0.5-5                                           56                                              46
                   5-30                                           60                                              50
Note 1: Decreases with the logarithm of the frequency. Note 2: A linear average detector is required




6.2    EUT Setup and Test Procedure




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification used was with the
FCC Part 15.207 limits



                                                                                                           Page 12 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                          Report No.: RXZ190624003-00A


The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz. During the conducted emission test,
the EMI test receiver was set with the following configurations


                           Frequency Range                                                     Receiver RBW

                           150 kHz - 30 MHz                                                         9 kHz
During the conducted emission test, the adapter was connected to the outlet of the LISN. Maximizing procedure was
performed on the six (6) highest emissions of the EUT. All data was recorded in the Quasi-peak and average detection
mode.


6.3      Test Equipment List and Details


      Description            Manufacture                 Model              Serial No.           Cal. Date.          Cal. Due.
                                                       Conduction Room

          LISN              Rohde & Schwarz            ENV216                 100010             2019/09/02         2020/09/01

 EMI Test Receiver          Rohde & Schwarz                ESR3               102430             2019/03/27         2020/03/26

      Pulse Limiter          SCHWARZBECK             VSTD 9561-F               00432             2019/08/28         2020/08/27
                                                   EMCCFD300-BM-
        RF Cable                  EMCI                                        180526             2019/08/08         2020/08/07
                                                      BM-8000
       Software                   Audix                    e3 v9              E3LK-03               N.C.R                N.C.R

*Statement of Traceability: The testing equipment’s listed above have finished the calibration by Electronics Testing Center, Taiwan

(ETC) or other laboratories which were accredited by TAF or equivalent organizations. The calibration result could be traceable to the

International System of Units (SI).



6.4      Test Environmental Conditions


           Temperature:                         25 ℃                     Relative Humidity:                       50 %
          ATM Pressure:                       1010 hPa                     Test Engineer:                      David Hsu
             Test Date:                       2019-10-21




                                                                                                        Page 13 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                     Report No.: RXZ190624003-00A


6.5     Test Data and Test Plot
Mode: AC 120 V/60 Hz, Line




Note:

Level = Read Level + Factor

Over Limit (Margin) = Level – Limit Line

Factor = (LISN, ISN, PLC or current probe) Factor + Cable Loss + Attenuator




                                                                                  Page 14 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                     Report No.: RXZ190624003-00A




Mode: AC 120V/60 Hz, Neutral




Note:

Level = Read Level + Factor

Over Limit (Margin) = Level – Limit Line

Factor = (LISN, ISN, PLC or current probe) Factor + Cable Loss + Attenuator




                                                                                  Page 15 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                  Report No.: RXZ190624003-00A


7      FCC §15.209, §15.205, §15.247(d) – Spurious Emissions

7.1     Applicable Standard
As per FCC §15.35(d): Unless otherwise specified, on any frequency or frequencies above 1000 MHz, the radiated
emission limits are based on the use of measurement instrumentation employing an average detector function. Unless
otherwise specified, measurements above 1000 MHz shall be performed using a minimum resolution bandwidth of 1MHz.


As Per FCC §15.205(a) except as show in paragraph (d) of this section, only spurious emissions are permitted in any of the
frequency bands listed below:


            MHz                             MHz                         MHz                            GHz
         0.090-0.110                    13.36-13.41                   399.9-410                      4.5-5.15
         0.495-0.505                    16.42-16.423                   608-614                       5.35-5.46
        2.1735-2.1905               16.69475-16.69525                 960-1240                       7.25-7.75
         4.125-4.128                     25.5-25.67                  1300-1427                       8.025-8.5
       4.17725-4.17775                   37.5-38.25                 1435-1626.5                       9.0-9.2
       4.20725-4.20775                    73-74.6                   1645.5-1646.5                     9.3-9.5
         6.215-6.218                     74.8-75.2                   1660-1710                       10.6-12.7
       6.26775-6.26825                   108-121.94                 1718.8-1722.2                   13.25-13.4
       6.31175-6.31225                    123-138                    2200-2300                      14.47-14.5
         8.291-8.294                    149.9-150.05                 2310-2390                      15.35-16.2
         8.362-8.366               156.52475-156.52525              2483.5-2500                      17.7-21.4
       8.37625-8.38675                  156.7-156.9                  2690-2900                     22.01-23.12
       8.41425-8.41475                162.0125-167.17                3260-3267                       23.6-24.0
        12.29-12.293                    167.72-173.2                 3332-3339                       31.2-31.8
      12.51975-12.52025                   240-285                   3345.8-3358                     36.43-36.5
      12.57675-12.57725                  322-335.4                   3600-4400                      Above 38.6




                                                                                                Page 16 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                           Report No.: RXZ190624003-00A


As per FCC §15.209(a): Except as provided elsewhere in this Subpart, the emissions from an intentional radiator shall not
exceed the field strength levels specified in the following table:


               Frequency                                   Field Strength                           Measurement Distance
                 (MHz)                                   (micro volts/meter)                              (meters)
              0.009 - 0.490                                   2400/F(kHz)                                      300
              0.490 - 1.705                                  24000/F(kHz)                                       30
               1.705 - 30.0                                        30                                           30
                  30 - 88                                        100**                                           3
                 88 - 216                                        150**                                           3
                216 - 960                                        200**                                           3
               Above 960                                          500                                            3


** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this Section shall not be

located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806MHz. However, operation within these frequency

bands is permitted under other sections of this Part, e.g., Sections 15.231 and 15.241.



As per FCC §15.247 (d) In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally
modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall
be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired
power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance
with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of
RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under
this paragraph shall be 30 dB instead of 20dB. Attenuation below the general limits specified in §15.209(a) is not required.
In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the
radiated emission limits specified in §15.209(a) (see §15.205(c).




                                                                                                          Page 17 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                              Report No.: RXZ190624003-00A


7.2    EUT Setup and Test Procedure




Radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance with the ANSI
C63.10-2013. The specification used was the FCC Part 15.209 and FCC 15.247 Limits.

The system was investigated from 30 MHz to 26.5 GHz. During the radiated emission test, the EMI test receiver was set
with the following configurations measurement method 6.3 in ANSI C63.10.


                                                                                                     Measurement
   Frequency Range                RBW                  VBW       Detector          Duty cycle
                                                                                                       method
      30-1000 MHz                120 kHz                    /       QP                 -                    QP
                                 1 MHz                3 MHz         PK                 -                    PK
      Above 1 GHz                1 MHz                3 MHz        RMS               >98%                   Ave
                                 1 MHz                  1/T         PK               <98%                   Ave


Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all installation
combinations. All data was recorded in the Quasi-peak detector mode from 30 MHz to 1 GHz and PK and average detector
modes for frequencies above 1 GHz.




                                                                                            Page 18 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                             Report No.: RXZ190624003-00A


7.3      Test Equipment List and Details


      Description            Manufacture                  Model                Serial No.           Cal. Date.          Cal. Due.
                                                             966A Room
  Bilog Antenna/6 dB        SUNOL SCIENCES &
                                                         JB3/N-6-06        A111513/AT-N0668         2019/03/29          2020/03/28
      Attenuator              EMEC /EMCI

      Horn Antenna             ETS-Lindgren                3115                 00109141            2019/07/05          2020/07/04

      Horn Antenna             ETS-Lindgren               3160-09               00123852            2019/07/11          2020/07/10

      Preamplifier             A.H. Systems            PAM-0118P                   478              2019/03/28          2020/03/27

      Preamplifier             A.H. Systems           PAM-1840VH                   174              2019/02/18          2020/02/17
 Signal and Spectrum
                            Rohde & Schwarzr               FSV40                 101434             2019/04/17          2020/04/16
       Analyzer

 Microflex Cable (1m)             EMCI             EMC106-SM-SM-2000            93D0127             2019/05/05          2020/05/04

                                                                               MFR64639
 Microflex Cable (2m)                 MTJ                  H0919                                    2019/05/05          2020/05/04
                                                                               226389-002
                                                    UFA210A-1-3149-
 Microflex Cable (8m)            UTIFLEX                                        160309-1            2019/05/05          2020/05/04
                                                        300300
       Turn Table                Chaintek                T-200-S-1               003501                N.C.R                N.C.R

    Antenna Tower                Chaintek              MBD-400-1                 003504                N.C.R                N.C.R


       Controller                Chaintek                 3000-1                 003507                N.C.R                N.C.R


        Software                  Audix                    e3 v9                 E3LK-01               N.C.R                N.C.R

                                                          Conducted Room
Signal Analyzer 40GHZ        Rohde & Schwarz              FSV40-N                102248             2019/09/11          2020/09/10

         Cable                        MTJ                 MT40S            620620-MT40S-100         2018/12/28          2019/12/27

*Statement of Traceability: The testing equipment’s listed above have finished the calibration by Electronics Testing Center, Taiwan

(ETC) or other laboratories which were accredited by TAF or equivalent organizations. The calibration result could be traceable to the
International System of Units (SI).



7.4      Test Environmental Conditions


          Temperature:                          25.6 ℃                     Relative Humidity:                        46 %
          ATM Pressure:                         1014hPa                      Test Engineer:                 Boris Kao / Boris Kao
       Radiated Test Date:              2019-10-18 to 2019-10-19         Conducted Test Date:                     2019-07-12




                                                                                                           Page 19 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                             Report No.: RXZ190624003-00A


7.5    Test Result

BLE Mode:
Transmitting mode (Pre-scan with three orthogonal axis, and worse case as X axis)
Below 1G (30 MHz-1 GHz) test the output power worst mode


                          Horizontal                                                Vertical




Result = Reading + Correct Factor

Margin = Result – Limit

Correct Factor = Antenna Factor + Cable Loss – Amplifier Gain

Spurious emissions more than 20 dB below the limit were not reported




                                                                                           Page 20 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                 Report No.: RXZ190624003-00A


Above 1G (1 GHz-26.5 GHz)

BLE mode:
                                                             Low CH
                         Horizontal                                     Vertical




                                                            Middle CH
                         Horizontal                                     Vertical




                                                             High CH
                         Horizontal                                     Vertical




                                                                               Page 21 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                Report No.: RXZ190624003-00A


Above 1G (1 GHz-26.5 GHz): The worst mode


                              Horizontal                               Vertical




Level = Read Level + Factor

Over Limit = Level – Limit

Correct Factor = Antenna Factor + Cable Loss – Amplifier Gain

Spurious emissions more than 20 dB below the limit were not reported




                                                                              Page 22 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                       Report No.: RXZ190624003-00A


Conducted Spurious Emissions:


                                                        Delta Peak to
                                 Frequency                              Limit
        Channel                                         Band Emission                           Result
                                   (MHz)                                (dBc)
                                                            (dBc)

                                                            BLE mode

          Low                       2402                     39.73      ≥ 20                 Compliance

          Mid                       2440                     38.35      ≥ 20                 Compliance

          High                      2480                     38.79      ≥ 20                 Compliance



                           Low CH                                          Middle CH




                          High CH                                                -




                                                                                 -




                                                                                     Page 23 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                             Report No.: RXZ190624003-00A


8      FCC §15.247(a)(2) – 6 dB Emission Bandwidth

8.1      Applicable Standard
According to FCC §15.247(a) (2),

Systems using digital modulation techniques may operate in the 902–928 MHz, 2400–2483.5 MHz, and 5725–5850 MHz
bands. The minimum 6 dB bandwidth shall be at least 500 kHz.


8.2      Test Procedure

According to ANSI C63.10-2013, the steps for the first option are as follows:
(1) Set RBW = 100 kHz. (2) Set the VBW ≥ [3 × RBW]. (3) Detector = peak. (4) Trace mode = max hold.
(5) Sweep = auto couple. (6) Allow the trace to stabilize. (7) Measure the maximum width of the emission that is
constrained by the frequencies associated with the two outermost amplitude points (upper and lower frequencies) that
are attenuated by 6 dB relative to the maximum level measured in the fundamental emission.


8.3      Test Equipment List and Details


      Description            Manufacture                  Model                Serial No.           Cal. Date.              Cal. Due.
                                                          Conducted Room
Signal Analyzer 40GHZ        Rohde & Schwarz              FSV40-N                102248              2019/09/11         2020/09/10

         Cable                        MTJ                 MT40S            620620-MT40S-100          2018/12/28         2019/12/27

*Statement of Traceability: The testing equipment’s listed above have finished the calibration by Electronics Testing Center, Taiwan

(ETC) or other laboratories which were accredited by TAF or equivalent organizations. The calibration result could be traceable to the

International System of Units (SI).



8.4      Test Environmental Conditions

          Temperature:                           25.6°C                    Relative Humidity:                        46 %
         ATM Pressure:                          1010hPa                      Test Engineer:                        Boris Kao
      Conducted Test Date:                     2019-07-12                            -                                  -




                                                                                                           Page 24 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                       Report No.: RXZ190624003-00A


8.5    Test Results

                                Frequency                   6 dB BW   6dB Limit
       Channel                                                                                  Result
                                   (MHz)                      (MHz)     (MHz)
                                                     BLE mode
          Low                      2402                      0.735      > 0.5                 Compliance

        Middle                     2440                      0.735      > 0.5                 Compliance

         High                      2480                      0.741      > 0.5                 Compliance



                      6 dB BW Low CH                                  6 dB BW Middle CH




                      6 dB BW High CH




                                                                                    Page 25 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                             Report No.: RXZ190624003-00A


9      FCC §15.247(b) (3) – Maximum Output Power

9.1      Applicable Standard
According to FCC §15.247(b) (3),

Systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: 1 Watt.

As an alternative to a peak power measurement, compliance with the one Watt limit can be based on a measurement of
the maximum conducted output power. Maximum Conducted Output Power is defined as the total transmit power
delivered to all antennas and antenna elements averaged across all symbols in the signaling alphabet when the
transmitter is operating at its maximum power control level. Power must be summed across all antennas and antenna
elements. The average must not include any time intervals during which the transmitter is off or is transmitting at a
reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods), the maximum
conducted output power is the highest total transmit power occurring in any mode.


9.2      Test Procedure

(1) Place the EUT on a bench and set it in transmitting mode.
(2) Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to
measuring equipment. (3). Add a correction factor to the display.


9.3      Test Equipment List and Details


      Description            Manufacture                 Model                 Serial No.           Cal. Date.              Cal. Due.
                                                         Conducted Room
      Power Sensor               Agilent                U2021XA               MY54250014            2018/11/12          2019/11/11

         Cable                        MTJ                MT40S             620620-MT40S-100         2018/12/28          2019/12/27

*Statement of Traceability: The testing equipment’s listed above have finished the calibration by Electronics Testing Center, Taiwan

(ETC) or other laboratories which were accredited by TAF or equivalent organizations. The calibration result could be traceable to the
International System of Units (SI).



9.4      Test Environmental Conditions


          Temperature:                         25.6°C                      Relative Humidity:                        46 %
          ATM Pressure:                       1010hPa                        Test Engineer:                        Boris Kao
      Conducted Test Date:                   2019-07-12                              -                                  -




                                                                                                           Page 26 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                            Report No.: RXZ190624003-00A


9.5    Test Results
                                                Maximum Peak        Maximum Peak
                            Frequency                                                Limit
      Channel                                   Output Power         Output Power                            Result
                               (MHz)                                                (dBm)
                                                    (dBm)                (W)

                                                            BLE mode:
         Low                    2402                  -2.29             0.0006        30                Compliance

       Middle                   2440                  -2.23             0.0006        30                Compliance

         High                   2480                  -2.22             0.0006        30                Compliance




                                                                                             Page 27 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                    Report No.: RXZ190624003-00A


10 FCC §15.247(d) – 100 kHz Bandwidth of Frequency Band Edge

10.1 Applicable Standard

According to FCC §15.247(d),

In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional
radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below
that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF
conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted
power limits.

If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as
permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of
20 dB.

Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated emissions which fall in
the restricted bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a)
(see §15.205(c)).



10.2 Test Procedure

(1) Check the calibration of the measuring instrument using either an internal calibrator or a known signal from an
    external generator.
(2) Position the EUT without connection to measurement instrument. Turn on the EUT and connect its antenna terminal
    to measurement instrument via a low loss cable. Then set it to any one measured frequency within its operating
    range, and make sure the instrument is operated in its linear range.
(3) Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span including 100 kHz
    bandwidth from band edge.
(4) Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the graph with
    marking the highest point and edge frequency.




                                                                                                  Page 28 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                             Report No.: RXZ190624003-00A


10.3 Test Equipment List and Details


    Description              Manufacture                  Model                Serial No.           Cal. Date.              Cal. Due.
                                                          Conducted Room
Signal Analyzer 40GHZ        Rohde & Schwarz              FSV40-N                102248             2019/09/11          2020/09/10

        Cable                         MTJ                 MT40S            620620-MT40S-100         2018/12/28          2019/12/27

*Statement of Traceability: The testing equipment’s listed above have finished the calibration by Electronics Testing Center, Taiwan

(ETC) or other laboratories which were accredited by TAF or equivalent organizations. The calibration result could be traceable to the

International System of Units (SI).



10.4 Test Environmental Conditions


         Temperature:                            25.6°C                    Relative Humidity:                        46 %
         ATM Pressure:                          1010hPa                      Test Engineer:                        Boris Kao
     Conducted Test Date:                      2019-07-12                            -                                  -




                                                                                                           Page 29 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                        Report No.: RXZ190624003-00A


10.5 Test Results

                                                              Delta Peak to
                                    Frequency                                  Limit
        Channel                                               Band Emission                            Result
                                       (MHz)                                   (dBc)
                                                                  (dBc)
                                                            BLE mode
           Low                         2402                       44.78         ≥ 20              Compliance

          High                         2480                       46.73         ≥ 20              Compliance



                          Left Side                                           Right Side




                                                                                       Page 30 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                             Report No.: RXZ190624003-00A


11 FCC §15.247(e) – Power Spectral Density

11.1 Applicable Standard

According to FCC §15.247(e),
For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall
not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. This power spectral
density shall be determined in accordance with the provisions of paragraph (b) of this section. The same method of
determining the conducted output power shall be used to determine the power spectral density.


11.2 Test Procedure

According to ANSI C63.10-2013,
(1) Set analyzer center frequency to DTS channel center frequency.
(2) Set the span to 1.5 times the DTS bandwidth. (3) Set the RBW to 3 kHz ≤ RBW ≤ 100 kHz.
(4) Set the VBW ≥ [3 × RBW]. (5) Detector = peak. (6) Sweep time = auto couple.
(7) Trace mode = max hold. (8) Allow trace to fully stabilize.
(9) Use the peak marker function to determine the maximum amplitude level within the RBW.
(10) If measured value exceeds requirement, then reduce RBW (but no less than 3 kHz) and repeat.


11.3 Test Equipment List and Details


    Description              Manufacture                  Model                Serial No.           Cal. Date.              Cal. Due.
                                                          Conducted Room
Signal Analyzer 40GHZ        Rohde & Schwarz              FSV40-N                102248              2019/09/11         2020/09/10

        Cable                         MTJ                 MT40S            620620-MT40S-100          2018/12/28         2019/12/27

*Statement of Traceability: The testing equipment’s listed above have finished the calibration by Electronics Testing Center, Taiwan

(ETC) or other laboratories which were accredited by TAF or equivalent organizations. The calibration result could be traceable to the

International System of Units (SI).



11.4 Test Environmental Conditions


         Temperature:                            25.6°C                    Relative Humidity:                        46 %
         ATM Pressure:                          1010hPa                      Test Engineer:                        Boris Kao
     Conducted Test Date:                      2019-07-12                            -                                  -




                                                                                                           Page 31 of 32


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                   Report No.: RXZ190624003-00A


11.5 Test Results


                           Frequency                    PSD                      Limit
    Channel                                                                                                 Result
                              (MHz)                 (dBm/3 kHz)               (dBm/3 kHz)

                                                              BLE mode
       Low                    2402                          -17.32                 8                      Compliance

     Middle                   2440                          -16.83                 8                      Compliance

       High                   2480                          -16.15                 8                      Compliance



                           Low CH                                                      Middle CH




                           High CH                                                           -




                                                                                             -




                                                  ----- END OF REPORT -----

                                                                                                 Page 32 of 32



Document Created: 2019-10-22 20:06:36
Document Modified: 2019-10-22 20:06:36

© 2024 FCC.report