RF exposure

FCC ID: 2APCQ-G08

RF Exposure Info

Download: PDF
FCCID_3829663

                                         RF Exposure Considerations


1. Measuring Standard
 KDB 680106 D01 RF Exposure Wireless Charging Apps v02
2. Requirements
 According to the item 5.2 of KDB 680106 D01v02:
 Inductive wireless power transfer applications that meet all of the following requirements are excluded from
 submitting an RF exposure evaluation.
 a) Power transfer frequency is less that 1 MHz
 b) Output power from each primary coil is less than 5 watts
 c) The transfer system includes only single primary and secondary coils. This includes charging systems that may
 have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of
 coils
 d) Client device is inserted in or placed directly in contact with the transmitter
 e) The maximum coupling surface area of the transmit (charging) device is between 60 cm2 and 400 cm2
 f) Aggregate leakage fields at 10 cm surrounding the device from all simultaneous transmitting coils are
 demonstrated to be less than 30% of the MPE limit.


                                  Limits For Maximum Permissible Exposure (MPE)


3. Test Setup




 Note: Measurements should be made from all sides and the top of the primary/client pair, with the 10cm measured
 from the center of the probe(s) to the edge of the device.


4.Test Procedure
 1) The RF exposure test was performed in anechoic chamber.
 2) The measurement probe was placed at test distance (10cm) which is between the edge of the charger and the
 geometric center of probe.
 3) The highest emission level was recorded and compared with limit as soon as measurement of each
 points (A, B, C, D, E) were completed.
 4) The EUT was measured according to the dictates of KDB 680106 D01 v02.
 Remark;
 The EUT’s test position A, B, C, D and E is valid for the E and H field measurements.

5. Test Equipment List
            Equipment                     Manufacturer             Model No.             Calibration Due

       Magnetic field meter                 NARDA                   ELT-400              Sep. 27, 2018


6. Test Result


                  E-Filed Strength at 10 cm from the edges surrounding the EUT (V/m)

   Frequency       Test         Test           Test          Test          Test        Limits Test
     Range       Position A   Position B     Position C    Position D    Position E      (V/m)
     (KHz)


    110~ 205      1.25          1.57          1.31          1.24           1.43           614


                  H-Filed Strength at 10 cm from the edges surrounding the EUT (A/m)

   Frequency       Test          Test          Test          Test          Test          Limits
     Range       Position A    Position B    Position C    Position D    Position E       Test
     (KHz)                                                                               (A/m)


   110~ 205       0.21          0.25          0.17          0.16           0.13         1.63