Test_Report_BLE_2APB4-FTS20CW_

FCC ID: 2APB4-FTS20CW

Test Report

Download: PDF
FCCID_3871571

                                    Shenzhen Toby Technology Co., Ltd.
                                                                                   Report No.: TB-FCC159719
                                                                                   Page:       1 of 28


                      FCC Radio Test Report
                        FCC ID: 2APB4-FTS20CW
                            FCC Class II Permissive Change
  Report No.             : TB-FCC159719
  Applicant              : Cooper Lighting, LLC
  Equipment Under Test (EUT)
  EUT Name               : LED FIXED LUMINAIRE
  Model No.              : FTS20CW
  Serial Model No.       : FTS20CB
  Brand Name             : N/A
  Receipt Date           : 2018-05-03
  Test Date              : 2018-05-04 to 2018-05-08
  Issue Date             : 2018-05-09
  Standards              : FCC Part 15: 2016, Subpart C(15.247)
  Test Method            : ANSI C63.10: 2013
  Conclusions            : PASS
                            In the configuration tested, the EUT complied with the standards specified above,


  Test/Witness
                            :
  Engineer

  Approved&
                            :
  Authorized


This report details the results of the testing carried out on one sample. The results contained in
this test report do not relate to other samples of the same product. The manufacturer should
ensure that all products in series production are in conformity with the product sample detailed in
the report.


                                                                                                           TB-RF-074-1.0

          1A/F., Bldg.6, Yusheng Industrial Zone, The National Road No.107 Xixiang Section 467, Xixiang,
                                      Bao’an, Shenzhen, China
                              Tel: +86 75526509301      Fax: +86 75526509195


                                                                                                       Report No.: TB-FCC159719
                                                                                                       Page:       2 of 28



                                                                 Contents

CONTENTS............................................................................................................................................. 2
1.  GENERAL INFORMATION ABOUT EUT ............................................................................. 4
    1.1 Client Information ................................................................................................................. 4
    1.2 General Description of EUT (Equipment Under Test) ................................................... 4
    1.3 Block Diagram Showing the Configuration of System Tested ...................................... 5
    1.4 Description of Support Units .............................................................................................. 5
    1.5 Description of Test Mode .................................................................................................... 6
    1.6 Description of Test Software Setting ................................................................................ 7
    1.7 Measurement Uncertainty .................................................................................................. 7
    1.8 Test Facility ........................................................................................................................... 8
2.  TEST SUMMARY ....................................................................................................................... 9
3.  TEST EQUIPMENT .................................................................................................................. 10
4.  CONDUCTED EMISSION TEST ........................................................................................... 11
    4.1 Test Standard and Limit .................................................................................................... 11
    4.2 Test Setup ........................................................................................................................... 11
    4.3 Test Procedure ................................................................................................................... 11
    4.4 EUT Operating Mode ........................................................................................................ 12
    4.5 Test Da5ta........................................................................................................................... 12
5.  RADIATED EMISSION TEST ................................................................................................ 13
    5.1 Test Standard and Limit .................................................................................................... 13
    5.2 Test Setup ........................................................................................................................... 14
    5.3 Test Procedure ................................................................................................................... 15
    5.4 EUT Operating Condition ................................................................................................. 16
    5.5 Test Data ............................................................................................................................. 16
ATTACHMENT A-- CONDUCTED EMISSION TEST DATA ....................................................... 17
ATTACHMENT B-- RADIATED EMISSION TEST DATA ............................................................ 21




                                                                                                                                   TB-RF-074-1.0


                                                   Report No.: TB-FCC159719
                                                   Page:       3 of 28



                         Revision History
Report No.     Version           Description                    Issued Date

TB-FCC159719   Rev.01         Initial issue of report            2018-05-09




                                                                 TB-RF-074-1.0


                                                                   Report No.: TB-FCC159719
                                                                   Page:       4 of 28



1. General Information about EUT
1.1 Client Information

     Applicant             : Cooper Lighting, LLC
     Address               : 1121 Highway 74 South Peachtree City, GA 30269, USA.
     Manufacturer          : Cooper Lighting, LLC
     Address               : 1121 Highway 74 South Peachtree City, GA 30269, USA.

1.2 General Description of EUT (Equipment Under Test)

    EUT Name           : LED FIXED LUMINAIRE
    Models No.         : FTS20CW, FTS20CB
    Model              : All these models are identical in the same PCB, layout and electrical
    Difference           circuit, the only difference is appearance and color.
                            Operation Frequency:     Bluetooth 4.2(BLE): 2402MHz~2480MHz
                            Number of Channel:       40 channels see note(3)

    Product                 RF Output Power:         -1.224dBm Conducted Power
                       :
    Description             Antenna Gain:            2dBi Internal Antenna
                            Modulation Type:         GFSK
                            Bit Rate of Transmitter: 1Mbps(GFSK)
    Power Supply       : AC Voltage supplied
    Power Rating       : Input: AC 120~277V, 50/60Hz
    Software
                       : N/A
    Version
    Hardware
                       : N/A
    Version
    Connecting         : Please refer to the User's Manual
    I/O Port(S)
Note:
This Test Report is FCC Part 15.247 for Bluetooth BLE, the test procedure follows the FCC KDB
558074 D01 DTS Means Guidance v04.
(1) For a more detailed features description, please refer to the manufacturer’s specifications or
   the User’s Manual.
(2) Antenna information provided by the applicant.




                                                                                    TB-RF-074-1.0


                                                                      Report No.: TB-FCC159719
                                                                      Page:       5 of 28


(3) Channel List:

                    Frequency                             Frequency                   Frequency
   Channel                            Channel                            Channel
                      (MHz)                                 (MHz)                       (MHz)
        00             2402                 14               2430             28         2458
        01             2404                 15               2432             29         2460
        02             2406                 16               2434             30         2462
        03             2408                 17               2436             31         2464
        04             2410                 18               2438             32         2466
        05             2412                 19               2440             33         2468
        06             2414                 20               2442             34         2470
        07             2416                 21               2444             35         2472
        08             2418                 22               2446             36         2474
        09             2420                 23               2448             37         2476
        10             2422                 24               2450             38         2478
        11             2424                 25               2452             39         2480
        12             2426                 26               2454
        13             2428                 27               2456

1.3 Block Diagram Showing the Configuration of System Tested

       TX Mode

         AC Voltage supplied                        EUT
                                  Cable 1




1.4 Description of Support Units

                                            Equipment Information
   Name                   Model                  FCC ID/VOC      Manufacturer      Used “√”
   /                        /                         /                  /               /

                                            Cable Information
   Number             Shielded Type              Ferrite Core         Length           Note
   Cable 1                 N0                        N0                1.2M              /




                                                                                     TB-RF-074-1.0


                                                                 Report No.: TB-FCC159719
                                                                 Page:       6 of 28



1.5 Description of Test Mode

  To investigate the maximum EMI emission characteristics generates from EUT, the test
  system was pre-scanning tested base on the consideration of following EUT operation mode
  or test configuration mode which possible have effect on EMI emission level. Each of these
  EUT operation mode(s) or test configuration mode(s) mentioned follow was evaluated
  respectively.

                                      For Radiated Test
     Final Test Mode                       Description
     Mode 1                                TX Mode
     Mode 2                                TX Mode (Channel 00/20/39)

  Note:
 (1) For all test, we have verified the construction and function in typical operation. And all the
     test modes were carried out with the EUT in transmitting operation in maximum power with
     all kinds of data rate.
     According to ANSI C63.10 standards, the measurements are performed at the highest,
     middle, lowest available channels, and the worst case data rate as follows:
        BLE Mode: GFSK Modulation Transmitting mode.
  (2) During the testing procedure, the continuously transmitting with the maximum power
      mode was programmed by the customer.
  (3) The EUT is considered a portable unit; in normal use it was positioned on X-plane. The
      worst case was found positioned on X-plane. Therefore only the test data of this X-plane
      was used for radiated emission measurement test.




                                                                                   TB-RF-074-1.0


                                                              Report No.: TB-FCC159719
                                                              Page:       7 of 28



1.6 Description of Test Software Setting

  During testing channel& Power controlling software provided by the customer was used to
  control the operating channel as well as the output power level. The RF output power
  selection is for the setting of RF output power expected by the customer and is going to be
  fixed on the firmware of the final end product power parameters of RF setting.

     Test Software Version              56317_InstalluEnergyTools_2_5_0_108 exe

                 Frequency         2402 MHz         2440MHz              2480 MHz

                 BLE GFSK            DEF               DEF                  DEF



1.7 Measurement Uncertainty

  The reported uncertainty of measurement y ± U,where expended uncertainty U is based on
  a standard uncertainty multiplied by a coverage factor of k=2 , providing a level of
  confidence of approximately 95 %.
     Test Item                  Parameters                   Expanded Uncertainty (ULab)
                                Level Accuracy:
     Conducted Emission         9kHz~150kHz                  ±3.42 dB
                                150kHz to 30MHz              ±3.42 dB
                                Level Accuracy:
     Radiated Emission                                       ±4.60 dB
                                9kHz to 30 MHz
                                Level Accuracy:
     Radiated Emission                                       ±4.40 dB
                                30MHz to 1000 MHz
                                Level Accuracy:
     Radiated Emission                                       ±4.20 dB
                                Above 1000MHz




                                                                               TB-RF-074-1.0


                                                               Report No.: TB-FCC159719
                                                               Page:       8 of 28



1.8 Test Facility

    The testing was performed by the Shenzhen Toby Technology Co., Ltd., in their facilities
    located at:1A/F., Bldg.6, Yusheng Industrial Zone, The National Road No.107 Xixiang
    Section 467, Xixiang, Bao’an, Shenzhen, Guangdong, China.
    At the time of testing, the following bodies accredited the Laboratory:
     CNAS (L5813)
    The Laboratory has been accredited by CNAS to ISO/IEC 17025: 2005 General
    Requirements for the Competence of Testing and Calibration Laboratories for the
    competence in the field of testing. And the Registration No.: CNAS L5813.
     A2LA Certificate No.: 4750.01
    The laboratory has been accredited by American Association for Laboratory
    Accreditation(A2LA) to ISO/IEC 17025:2005 General Requirements for the Competence of
    Testing and Calibration Laboratories for the technical competence in the field of Electrical
    Testing. And the A2LA Certificate No.: 4750.01.
     IC Registration No.: (11950A-1)
    The Laboratory has been registered by Certification and Engineering Bureau of Industry
    Canada for radio equipment testing. The site registration: Site# 11950A-1.




                                                                                 TB-RF-074-1.0


                                                                       Report No.: TB-FCC159719
                                                                       Page:       9 of 28



2. Test Summary
                       FCC Part 15 Subpart C(15.247)/RSS 247 Issue 2
        Standard Section
                                                  Test Item                Judgment          Remark
       FCC             IC
      15.203                           Antenna Requirement                    PASS                N/A
                        RSS-GEN
     15.207(a)                         Conducted Emission                     PASS                N/A
                          7.2.4
                                       Band-Edge & Unwanted
                        RSS-GEN                                                                   N/A
 15.205&15.247(d)                      Emissions into Restricted              PASS
                          7.2.2                                                                   Note(3)
                                       Frequency
                        RSS 247                                                                   N/A
   15.247(a)(2)                        6dB Bandwidth                          PASS
                         5.2 (1)                                                                  Note(3)

                        RSS 247        Conducted Max Output                                       N/A
   15.247(b)(3)                                                               PASS
                         5.4 (4)       Power                                                      Note(3)

                        RSS 247                                                                   N/A
     15.247(e)                         Power Spectral Density                 PASS
                         5.2 (2)                                                                  Note(3)

                                       Transmitter Radiated
      15.205,           RSS 247        Spurious &Unwanted
                                                                              PASS                N/A
 15.209&15.247(d)         5.5          Emissions into Restricted
                                       Frequency
 Note: (1): “/” for no requirement for this test item.
      (2): N/A is an abbreviation for Not Applicable.
      (3): This report is Class II change report for the original equipment have changed,
            the transmitter module itself has not changed. More information about the test data
            please refer to the original test report.




                                                                                           TB-RF-074-1.0


                                                                             Report No.: TB-FCC159719
                                                                             Page:       10 of 28



3. Test Equipment
Conducted Emission Test
                                                                                                      Cal. Due
Equipment                Manufacturer         Model No.           Serial No.       Last Cal.
                                                                                                      Date
EMI Test Receiver        Rohde & Schwarz      ESCI                100321           Jul. 20, 2017      Jul. 19, 2018
                         Compliance
RF Switching Unit        Direction Systems    RSU-A4              34403            Jul. 20, 2017      Jul. 19, 2018
                         Inc
AMN                      SCHWARZBECK          NNBL 8226-2         8226-2/164       Jul. 20, 2017      Jul. 19, 2018

LISN                     Rohde & Schwarz      ENV216              101131           Jul. 20, 2017      Jul. 19, 2018

Radiation Emission Test
                                                                                                      Cal. Due
Equipment                Manufacturer         Model No.           Serial No.       Last Cal.
                                                                                                      Date
Spectrum
                         Agilent              E4407B              MY45106456       Jul. 20, 2017      Jul. 19, 2018
Analyzer
EMI Test
                         Rohde & Schwarz      ESPI                100010/007       Jul. 20, 2017      Jul. 19, 2018
Receiver
Bilog Antenna            ETS-LINDGREN         3142E               00117537         Mar.16, 2018       Mar. 15, 2019

Bilog Antenna            ETS-LINDGREN         3142E               00117542         Mar.16, 2018       Mar. 15, 2019

Horn Antenna             ETS-LINDGREN         3117                00143207         Mar.16, 2018       Mar. 15, 2019

Horn Antenna             ETS-LINDGREN         3117                00143209         Mar.16, 2018       Mar. 15, 2019

Loop Antenna             Laplace instrument   RF300               0701             Mar.16, 2018       Mar. 15, 2019

Pre-amplifier            Sonoma               310N                185903           Mar.16, 2018       Mar. 15, 2019

Pre-amplifier            HP                   8449B               3008A00849       Mar.16, 2018       Mar. 15, 2019

Cable                    HUBER+SUHNER         100                 SUCOFLEX         Mar.16, 2018       Mar. 15, 2019

Positioning Controller   ETS-LINDGREN         2090                N/A              N/A                N/A
Antenna Conducted Emission
                                                                                                      Cal. Due
Equipment                Manufacturer         Model No.           Serial No.       Last Cal.
                                                                                                      Date
Spectrum Analyzer        Agilent              E4407B              MY45106456       Jul. 20, 2017      Jul. 19, 2018

Spectrum Analyzer        Rohde & Schwarz      ESCI                100010/007       Jul. 20, 2017      Jul. 19, 2018

MXA Signal Analyzer      Agilent              N9020A              MY49100060       Oct. 26, 2017      Oct. 25, 2018
Vector Signal
                         Agilent              N5182A              MY50141294       Oct. 26, 2017      Oct. 25, 2018
Generator
Analog Signal
                         Agilent              N5181A              MY50141953       Oct. 26, 2017      Oct. 25, 2018
Generator

                         DARE!! Instruments   RadiPowerRPR3006W   17I00015SNO26    Oct. 26, 2017      Oct. 25, 2018

                         DARE!! Instruments   RadiPowerRPR3006W   17I00015SNO29    Oct. 26, 2017      Oct. 25, 2018
RF Power Sensor
                         DARE!! Instruments   RadiPowerRPR3006W   17I00015SNO31    Oct. 26, 2017      Oct. 25, 2018

                         DARE!! Instruments   RadiPowerRPR3006W   17I00015SNO33    Oct. 26, 2017      Oct. 25, 2018



                                                                                                   TB-RF-074-1.0


                                                              Report No.: TB-FCC159719
                                                              Page:       11 of 28



4. Conducted Emission Test
4.1 Test Standard and Limit

  4.1.1Test Standard
       FCC Part 15.207
  4.1.2 Test Limit
                            Conducted Emission Test Limit
                                          Maximum RF Line Voltage (dBV)
                Frequency
                                      Quasi-peak Level        Average Level
              150kHz~500kHz               66 ~ 56 *             56 ~ 46 *
               500kHz~5MHz                   56                     46
               5MHz~30MHz                    60                     50
     Notes:
     (1) *Decreasing linearly with logarithm of the frequency.
     (2) The lower limit shall apply at the transition frequencies.
     (3) The limit decrease in line with the logarithm of the frequency in the range of 0.15 to
     0.50MHz.

4.2 Test Setup




4.3 Test Procedure

   The EUT was placed 0.8 meters from the horizontal ground plane with EUT being
   connected to the power mains through a line impedance stabilization network (LISN). All
   other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/
   50uH of coupling impedance for the measuring instrument.

   Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
   and forth in the center forming a bundle 30 to 40 cm long.


                                                                                TB-RF-074-1.0


                                                              Report No.: TB-FCC159719
                                                              Page:       12 of 28



   I/O cables that are not connected to a peripheral shall be bundled in the center. The end of
   the cable may be terminated, if required, using the correct terminating impedance. The
   overall length shall not exceed 1 m.

   LISN at least 80 cm from nearest part of EUT chassis.

   The bandwidth of EMI test receiver is set at 9 kHz, and the test frequency band is from
   0.15MHz to 30MHz.

4.4 EUT Operating Mode

   Please refer to the description of test mode.

4.5 Test Da5ta

   Please refer to the Attachment A.




                                                                                TB-RF-074-1.0


                                                          Report No.: TB-FCC159719
                                                          Page:       13 of 28



5. Radiated Emission Test
5.1 Test Standard and Limit

  5.1.1 Test Standard
        FCC Part 15.247(d)
  5.1.2 Test Limit
                             Radiated Emission Limits (9kHz~1000MHz)
           Frequency                  Field Strength         Measurement Distance
              (MHz                   (microvolt/meter)             (meters)

           0.009~0.490                 2400/F(KHz)                     300

           0.490~1.705                 24000/F(KHz)                       30

           1.705~30.0                       30                            30

              30~88                        100                            3

             88~216                        150                            3

            216~960                        200                            3

            Above 960                      500                            3


                        Radiated Emission Limit (Above 1000MHz)

                                                 Distance Meters(at 3m)
             Frequency
               (MHz)                          Peak                      Average
                                            (dBuV/m)                   (dBuV/m)
           Above 1000                            74                           54

   Note:
   (1) The tighter limit applies at the band edges.
   (2) Emission Level (dBuV/m)=20log Emission Level (uV/m)




                                                                               TB-RF-074-1.0


                                           Report No.: TB-FCC159719
                                           Page:       14 of 28



5.2 Test Setup




                  Below 30MHz Test Setup




                 Below 1000MHz Test Setup




                                                         TB-RF-074-1.0


                                                               Report No.: TB-FCC159719
                                                               Page:       15 of 28




                                 Above 1GHz Test Setup

5.3 Test Procedure

(1) The measuring distance of 3m shall be used for measurements at frequency up to 1GHz and
    above 1 GHz. The EUT was placed on a rotating 0.8m high above ground, the table was
    rotated 360 degrees to determine the position of the highest radiation.
(2) Measurements at frequency above 1GHz. The EUT was placed on a rotating 1.5m high
    above the ground. RF absorbers covered the ground plane with a minimum area of 3.0m by
    3.0m between the EUT and measurement receiver antenna. The RF absorber shall not
    exceed 30cm in high above the conducting floor. The table was rotated 360 degrees to
    determine the position of the highest radiation.
(3) The Test antenna shall vary between 1m and 4m, Both Horizontal and Vertical antenna are
    set to make measurement.
(4) The initial step in collecting conducted emission data is a spectrum analyzer peak detector
    mode pre-scanning the measurement frequency range. Significant peaks are then marked
    and then Quasi Peak detector mode re-measured.
(5) If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit
    Bellow 1 GHz, the EUT shall be deemed to meet QP Limits and then no additional QP Mode
    measurement performed. But the Peak Value and average value both need to comply with
    applicable limit above 1 GHz.
(6) Testing frequency range below 1GHz the measuring instrument use VBW=120 kHz with
    Quasi-peak detection.
(7) Testing frequency range above 1GHz the measuring instrument use RBW=1 MHz and
    VBW=3 MHz with Peak Detector for Peak Values, and use RBW=1 MHz and VBW=10 Hz
    with Peak Detector for Average Values.
(8) For the actual test configuration, please see the test setup photo.




                                                                                TB-RF-074-1.0


                                                            Report No.: TB-FCC159719
                                                            Page:       16 of 28



5.4 EUT Operating Condition

The Equipment Under Test was set to Continual Transmitting in maximum power.

5.5 Test Data

   Remark: During testing above 1GHz the measuring instrument use RBW=1 MHz and VBW=3
            MHz with Peak Detector for Peak Values, and use RBW=1 MHz and VBW=10 Hz
            with Peak Detector for Average Values.
    Please refer to the Attachment B.




                                                                               TB-RF-074-1.0


                                                              Report No.: TB-FCC159719
                                                              Page:       17 of 28



Attachment A-- Conducted Emission Test Data
     Temperature:    25℃                       Relative Humidity:   55%
     Test Voltage:   AC 120V/60 Hz
     Terminal:       Line
     Test Mode:      TX GFSK Mode 2402 MHz
     Remark:         Only worse case is reported




     Emission Level= Read Level+ Correct Factor




                                                                            TB-RF-074-1.0


                                                           Report No.: TB-FCC159719
                                                           Page:       18 of 28



Temperature:     25℃                           Relative Humidity:   55%
Test Voltage:    AC 120V/60 Hz
Terminal:        Neutral
Test Mode:       TX GFSK Mode 2402 MHz
Remark:          Only worse case is reported




Emission Level= Read Level+ Correct Factor




                                                                          TB-RF-074-1.0


                                                            Report No.: TB-FCC159719
                                                            Page:       19 of 28



Temperature:    25℃                           Relative Humidity:   55%
Test Voltage:   AC 240V/60 Hz
Terminal:       Line
Test Mode:      TX GFSK Mode 2402 MHz
Remark:         Only worse case is reported




Emission Level= Read Level+ Correct Factor




                                                                          TB-RF-074-1.0


                                                           Report No.: TB-FCC159719
                                                           Page:       20 of 28



Temperature:     25℃                           Relative Humidity:   55%
Test Voltage:    AC 240V/60 Hz
Terminal:        Neutral
Test Mode:       TX GFSK Mode 2402 MHz
Remark:          Only worse case is reported




Emission Level= Read Level+ Correct Factor




                                                                          TB-RF-074-1.0


                                                                  Report No.: TB-FCC159719
                                                                  Page:       21 of 28



Attachment B-- Radiated Emission Test Data
  9 KHz~30 MHz
   From 9 KHz to 30 MHz: Conclusion: PASS
   Note: The amplitude of spurious emissions which are attenuated by more than 20dB
        Below the permissible value has no need to be reported.
  30MHz~1GHz

      Temperature:    25℃                           Relative Humidity:   55%
      Test Voltage:   AC 120V/60HZ
      Ant. Pol.       Horizontal
      Test Mode:      BLE TX 2402 Mode
      Remark:         Only worse case is reported




      Emission Level= Read Level+ Correct Factor




                                                                                TB-RF-074-1.0


                                                         Report No.: TB-FCC159719
                                                         Page:       22 of 28



Temperature:    25℃                       Relative Humidity:   55%
Test Voltage:   AC 120V/60HZ
Ant. Pol.       Vertical
Test Mode:      BLE TX 2402 Mode
Remark:         Only worse case is reported




Emission Level= Read Level+ Correct Factor




                                                                       TB-RF-074-1.0


                                                             Report No.: TB-FCC159719
                                                             Page:       23 of 28


Above 1GHz

   Temperature:     25℃                         Relative Humidity:    55%
   Test Voltage:    AC 120V/60HZ
   Ant. Pol.        Horizontal
   Test Mode:       BLE Mode TX 2402 MHz
   Remark:          No report for the emission which more than 10 dB below the
                    prescribed limit.




   Emission Level= Read Level+ Correct Factor




                                                                                 TB-RF-074-1.0


                                                          Report No.: TB-FCC159719
                                                          Page:       24 of 28



Temperature:     25℃                       Relative Humidity:    55%
Test Voltage:    AC 120V/60HZ
Ant. Pol.        Vertical
Test Mode:       BLE Mode TX 2402 MHz
Remark:          No report for the emission which more than 10 dB below the
                 prescribed limit.




Emission Level= Read Level+ Correct Factor




                                                                              TB-RF-074-1.0


                                                          Report No.: TB-FCC159719
                                                          Page:       25 of 28



Temperature:     25℃                         Relative Humidity:    55%
Test Voltage:    AC 120V/60HZ
Ant. Pol.        Horizontal
Test Mode:       BLE Mode TX 2442 MHz
Remark:          No report for the emission which more than 10 dB below the
                 prescribed limit.




Emission Level= Read Level+ Correct Factor




                                                                              TB-RF-074-1.0


                                                          Report No.: TB-FCC159719
                                                          Page:       26 of 28



Temperature:     25℃                         Relative Humidity:    55%
Test Voltage:    AC 120V/60HZ
Ant. Pol.        Vertical
Test Mode:       BLE Mode TX 2442 MHz
Remark:          No report for the emission which more than 10 dB below the
                 prescribed limit.




Emission Level= Read Level+ Correct Factor




                                                                              TB-RF-074-1.0


                                                          Report No.: TB-FCC159719
                                                          Page:       27 of 28



Temperature:     25℃                         Relative Humidity:    55%
Test Voltage:    AC 120V/60HZ
Ant. Pol.        Horizontal
Test Mode:       BLE Mode TX 2480 MHz
Remark:          No report for the emission which more than 10 dB below the
                 prescribed limit.




Emission Level= Read Level+ Correct Factor




                                                                              TB-RF-074-1.0


                                                          Report No.: TB-FCC159719
                                                          Page:       28 of 28



Temperature:     25℃                         Relative Humidity:    55%
Test Voltage:    AC 120V/60HZ
Ant. Pol.        Vertical
Test Mode:       BLE Mode TX 2480 MHz
Remark:          No report for the emission which more than 10 dB below the
                 prescribed limit.




Emission Level= Read Level+ Correct Factor




                            -----END OF REPORT------




                                                                              TB-RF-074-1.0



Document Created: 2018-05-30 09:17:47
Document Modified: 2018-05-30 09:17:47

© 2025 FCC.report