RF Exposure Info

FCC ID: 2APA9-IPC019C

RF Exposure Info

Download: PDF
FCCID_4488648

                                            SGS-CSTC Standards Technical Services Co.,
                                            Ltd. Shanghai Branch
                                                                                        Report No.: SHEM190801629802
                                                                                        Page:       1 of 7


  1       Cover Page

                    RF Exposure Evaluation Report
  Application No.:                       SHEM1908016298CR
  FCC ID:                                2APA9-IPC019C
  Applicant:                             Shanghai Imilab Technology Co., Ltd.
                                         Room 908, No. 1, Lane 399, Shengxia Rd., China Pilot Free Trade Zone,
  Address of Applicant:
                                         Shanghai, China 201210
  Manufacturer:                          Shanghai Imilab Technology Co., Ltd.
                                         Room 908, No. 1, Lane 399, Shengxia Rd., China Pilot Free Trade Zone,
  Address of Manufacturer:
                                         Shanghai, China 201210
  Factory:                               Dongguan Sharetronic Data Technology Co., Ltd.
                                         Weiqiang Science and Technology Park, Galaxy Industrial Zone,Qingxi,
  Address of Factory:
                                         Dongguan, Guangdong Province,China
  Equipment Under Test (EUT):
  EUT Name:                 IMI Home Security Camera 1080p Global
  Model No.:                CMSXJ19C

  Trade Mark:

                                         FCC Rules 47 CFR §2.1091
  Standard(s) :
                                         KDB447498 D01 General RF Exposure Guidance v06
  Date of Receipt:                       2019-08-15
  Date of Test:                          2019-08-22 to 2019-09-03
  Date of Issue:                         2019-09-16
  Test Result:                     Pass*
  * In the configuration tested, the EUT complied with the standards specified above.




               Parlam Zhan
            E&E Section Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS
International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by
SGS International Electrical Approvals in writing.


               SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
               Branch
                                                           Report No.: SHEM190801629802
                                                           Page:       2 of 7




                                   Revision Record
  Version        Description                    Date                     Remark

      00           Original                  2019-09-16                      /




Authorized for issue
by:




                              Bill Wu / Project Engineer




                              Parlam Zhan / Reviewer


                                    SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                                    Branch
                                                                                                          Report No.: SHEM190801629802
                                                                                                          Page:       3 of 7




2         Contents
                                                                                                                                                             Page
1     COVER PAGE ................................................................................................................................................ 1
2     CONTENTS ..................................................................................................................................................... 3
3     GENERAL INFORMATION .......................................................................................................................... 4
    3.1       GENERAL DESCRIPTION OF E.U.T. ......................................................................................................... 4
    3.2       TEST LOCATION ....................................................................................................................................... 5
    3.3       TEST FACILITY.......................................................................................................................................... 5
4     TEST STANDARDS AND LIMITS ............................................................................................................... 6
    4.1       FCC RADIOFREQUENCY RADIATION EXPOSURE LIMITS: ......................................................................... 6
5     MEASUREMENT AND CALCULATION .................................................................................................... 6
    5.1       MAXIMUM TRANSMIT POWER.................................................................................................................... 6
    5.2       MPE CALCULATION ................................................................................................................................. 7


                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                      Branch
                                                          Report No.: SHEM190801629802
                                                          Page:       4 of 7




3   General Information

3.1 General Description of E.U.T.
                           DC 5V 2A By adapter
                           Adapter:
    Power supply:          Model:A162-050200U-US2
                           Input:100-240V
                           Output:5V 2A
    Test voltage:          AC 120V/60Hz
    Cable:                 USB Cable 1.8m
    Antenna Gain           1dBi
    Antenna Type           PIFA Antenna
    Channel Spacing        5MHz
                           802.11b: DSSS (CCK, DQPSK, DBPSK)
    Modulation Type
                           802.11g/n: OFDM (64QAM, 16QAM, QPSK, BPSK)
                           802.11b/g/n(HT20):11
    Number of Channels
                           802.11n(HT40):7
                           802.11b/g/n(HT20): 2412MHz to 2462MHz
    Operation Frequency
                           802.11n(HT40): 2422MHz to 2452MHz


                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                      Branch
                                                                     Report No.: SHEM190801629802
                                                                     Page:       5 of 7




3.2 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch
    588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China.
    Tel: +86 21 6191 5666
    Fax: +86 21 6191 5678

3.3 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L0599)
    CNAS has accredited SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. to ISO/IEC
    17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories
    (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration Laboratories) for the
    competence in the field of testing.
    • NVLAP (Certificate No. 201034-0)
    SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. is accredited by the National Voluntary
    Laboratory Accreditation Program(NVLAP). Certificate No. 201034-0.
    • FCC –Designation Number: CN5033
    SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. has been recognized as an accredited
    testing laboratory.
    Designation Number: CN5033. Test Firm Registration Number: 479755.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    IC Registration No.: 8617A-1. CAB Identifier: CN0020.
    • VCCI (Member No.: 3061)
    The 3m Semi-anechoic chamber and Shielded Room of SGS-CSTC Standards Technical Services
    (Shanghai) Co., Ltd. has been registered in accordance with the Regulations for Voluntary Control
    Measures with Registration No.: R-13868, C-14336, T-12221, G-10830 respectively.


                       SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                       Branch
                                                                   Report No.: SHEM190801629802
                                                                   Page:       6 of 7




4    Test Standards and Limits

4.1 FCC Radiofrequency radiation exposure limits:
 According to§1.1310, the limit for general population/uncontrolled exposures

          Frequency            Power density(mW/cm2)         Averaging time(minutes)

     300MHz~1.5GHz                      f/1500                         30

     1.5GHz~100GHz                        1.0                          30



5    Measurement and Calculation

5.1 Maximum transmit power
 The Power Data is based on the RF Test Report SHEM190801629801
    Test         Test                  Power         Power
                              Ant
    Mode        Channel                [dBm]         [mW]
    11B           2412       Ant1      11.20         13.18
    11B           2437       Ant1      11.73         14.89
    11B           2462       Ant1      11.82         15.21
    11G           2412       Ant1      10.80         12.02
    11G           2437       Ant1      11.35         13.65
    11G           2462       Ant1      11.50         14.13
11N20SISO         2412       Ant1      10.87         12.22
11N20SISO         2437       Ant1      11.33         13.58
11N20SISO         2462       Ant1      11.48         14.06
11N40SISO         2422       Ant1      10.90         12.30
11N40SISO         2437       Ant1      10.15         10.35
11N40SISO         2452       Ant1      10.26         10.62


                       SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                       Branch
                                                                   Report No.: SHEM190801629802
                                                                   Page:       7 of 7




5.2 MPE Calculation
For FCC:
      According to the formula S=P/4πR², we can calculate S which is MPE.
      Note:
      1)   P (mW)
      2)   R = distance to the center of radiation of antenna (in meter) = 20cm
      3)   MPE limit = 1mW/cm²

      The max. antenna gain is           1       dBi
          Max.                                     Power
                      Gain in       Operation
       Conducted                                                Limit
                   Linear Scale     Distance      Density             2      Result
         Power                                           2    (mW/cm )
                        G            R(cm)       (mW/cm )
         P(mW)
          15.21       1.259             20        0.00381          1          Pass


So the device is exclusion from SAR test.

                                       --End of the Report--



Document Created: 2019-09-19 10:57:11
Document Modified: 2019-09-19 10:57:11

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC