Test Report-MPE

FCC ID: 2AP7A-AMBER12

RF Exposure Info

Download: PDF
FCCID_4083053

                                                          RF Exposure Report

                      Report No.: SA180619C29

                            FCC ID: 2AP7A-AMBER12

                      Test Model: AM12

                 Received Date: Jun. 19, 2018

          Date of Evaluation: Sep. 03, 2018

                     Issued Date: Oct. 24, 2018


                        Applicant: LatticeWork, Inc.

                          Address: 2210 O’Toole Ave, Suite 250, San Jose, CA 95131



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                   Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd, Wen Hwa Vil, Kwei Shan Dist., Taoyuan City
                                 33383, Taiwan (R.O.C)
           FCC Registration /
                                            788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken o r any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information t hat you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.



Report No.: SA180619C29                                              Page No. 1 / 6                                             Report Format Version: 6.1.1


                                                               Table of Contents
Release Control Record ........................................................................................................................ 3
1         Certificate of Conformity ............................................................................................................. 4
2         RF Exposure ............................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) ........................................................................ 5
    2.2      MPE Calculation Formula........................................................................................................... 5
    2.3      Classification ............................................................................................................................. 5
    2.4      Calculation Result of Maximum Conducted Power ....................................................................... 6




Report No.: SA180619C29                                          Page No. 2 / 6                                           Report Format Version: 6.1.1


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA180619C29           Original Release                                   Oct. 24, 2018




Report No.: SA180619C29                     Page No. 3 / 6        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Amber Life

              Brand: LatticeWork

        Test Model: AM12

    Sample Status: Engineering Sample

          Applicant: LatticeWork, Inc .

Date of Evaluation: Sep. 03, 2018

         Standards: FCC Part 2 (Section 2.1091)

                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                              ,   Date:       Oct. 24, 2018
                                 Rona Chen / Specialist




     Approved by :                                               ,   Date:       Oct. 24, 2018
                              Dylan Chiou / Project Engineer




Report No.: SA180619C29                         Page No. 4 / 6                        Report Format Version: 6.1.1


2      RF Exposure

2.1      Limits for Maximum Permissible Exposure (MPE)

    Frequency Range           Electric Field     Magnetic Field       Power Density       Average Time
         (MHz)               Strength (V/m)      Strength (A/m)         (mW/cm2)            (minutes)
                              Limits For General Population / Uncontrolled Exposure
        0.3-1.34                  614                  1.63               (100)*                 30
         1.34-30                 824/f                2.19/f             (180/f2)*               30
         30-300                   27.5                0.073                0.2                   30
        300-1500                   …                    …                 f/1500                 30
      1500-100,000                 …                    …                  1.0                   30
f = Frequency in MHz ; *Plane-wave equivalent power density



2.2      MPE Calculation Formula

Pd = (Pout*G) / (4*pi*r 2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm



2.3      Classification

      The antenna of this product, under normal use condition, is at least 20cm away from the body of the user.
         So, this device is classified as Mobile Device.




Report No.: SA180619C29                           Page No. 5 / 6                        Report Format Version: 6.1.1


2.4    Calculation Result of Maximum Conducted Power

                Frequency Band      Max Power      Antenna Gain       Distance      Power Density        Limit
      Band
                    (MHz)             (dBm)            (dBi)            (cm)          (mW/cm2)         (mW/cm2)
                                                   CDD Mode
                   2412-2462           29.21             9.66             33            0.563              1.00

      WLAN         5260-5320           22.79             9.91             33            0.136              1.00

                   5500-5700           22.64             9.92             33            0.132              1.00
                                               Beamforming Mode
                   5260-5320           20.08             9.91             33            0.073              1.00
      WLAN
                   5500-5700           20.07             9.92             33            0.073              1.00
Note:
2.4 GHz: Directional gain = 10 log[(10G1 /10 + 10G2 /10 + ... + 10GN /10) /NANT]= 9.66
5260 ~ 5320 MHz: Directional gain = 10 log[(10 G1 /10 + 10G2 /10 + ... + 10GN /10) /NANT]= 9.91
5500 ~ 5700 MHz: Directional gain = 10 log[(10 G1 /10 + 10G2 /10 + ... + 10GN /10) /NANT]= 9.92

Conclusion:
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density

WLAN 2.4G + WLAN 5.0G = 0.563 + 0.136 = 0.699
Therefore the maximum calculations of above situations are less than the “1” limit.

--- END ---




Report No.: SA180619C29                          Page No. 6 / 6                            Report Format Version: 6.1.1



Document Created: 2019-03-22 04:32:34
Document Modified: 2019-03-22 04:32:34

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC