Test report

FCC ID: 2AOVX-T1

Test Report

Download: PDF
FCCID_3873191

                       Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                       Report No: CCISE180412101

1       Cover Page

                              FCC REPORT
    Applicant:                          Green Start Industries LLC
    Address of Applicant:               3305 Fairmount Ave Ocean NJ USA
    Equipment Under Test (EUT)

     Product Name:                      keyless transmitter
     Model No.:                         2AOVX-3B, 2AOVX-4B
    FCC ID:                             2AOVX-T1
    Applicable standards:               FCC CFR Title 47 Part 15 Subpart C Section 15.231(a)
    Date of sample receipt:             25 Apr., 2018
    Date of Test:                       25 Apr., to 16 May., 2018
    Date of report issue:               17 May., 2018
    Test Result:                        PASS*

*    In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




        Bruce Zhang
     Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                 Report No: CCISE180412101


2      Version
     Version No.                         Date                                    Description
            00                     17 May., 2018                                   Original




    Prepared By:                                                         Date:          17 May., 2018

                                       Test Engineer

    Check By:                                                            Date:          17 May., 2018

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 2 of 25


                                                                                                                           Report No: CCISE180412101

3         Contents
                                                                                                                                                                               Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST MODE ............................................................................................................................................................ 5
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 5
    5.5         LABORATORY FACILITY.......................................................................................................................................... 6
    5.6         LABORATORY LOCATION ....................................................................................................................................... 6
    5.7         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 6
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 7
    6.1     ANTENNA REQUIREMENT ....................................................................................................................................... 7
    6.2     RADIATED EMISSION ............................................................................................................................................. 8
       6.2.1 Field Strength Of The Fundamental Signal .............................................................................................. 10
       6.2.2 Spurious Emissions ..................................................................................................................................... 12
    6.3     20DB BANDWIDTH ............................................................................................................................................... 14
    6.4     DURATION TIME ................................................................................................................................................... 16
7       TEST SETUP PHOTOS...................................................................................................................................... 18
8       EUT CONSTRUCTIONAL PHOTOS ................................................................................................................. 19




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                          Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                        Page 3 of 25


                                                                                   Report No: CCISE180412101

4      Test Summary
                    Test Item                                 Section in CFR 47                     Result
              Antenna requirement                                    15.203                          Pass
    Field strength of the fundamental signal                       15.231 (a)                        Pass
               Spurious emissions                              15.231 (b)/15.209                     Pass
                20dB Bandwidth                                      15.231 (c)                       Pass
                    Dwell time                                     15.231 (a)                        Pass

              Conducted Emission                                     15.107                          N/A
 Remarks:
 N/A: The EUT not applicable of the test item.
 Pass: The EUT complies with the essential requirements in the standard.
 TEST ACCORDING TO ANSI C63.4:2014 AND ANSI C63.10:2013.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 4 of 25


c c I s                                                                          Report No: CCISE180412101

5        General Information
5.1 Client Information
            Applicant:                      Green Start Industries LLC
            Address of Applicant:           3305 Fairmount Ave Ocean NJ USA
            Manufacturer:                   Green Start Industries LLC
            Address of Manufacturer:        3305 Fairmount Ave Ocean NJ USA

5.2 General Description of E.U.T.
            Product Name:                   keyless transmitter
          Model No.:                        2AOVX—3B, 2AOVX—4B
         Operation Frequency:               314.35MHz
         Channel numbers:                   1
          Modulation type:                  ASK
         Antenna Type:                      PCB antenna
         Antenna gain:                      0 dBi
            Power supply:                   DC 3V (CR2025 battery)
            Remark:                         The remote control has two moadels, named as : 2AOVX—3B, 2AOVX—
                                            4B.The shell has 3 or 4 button, the PCB funtion is the same.

5.3 Test mode
       Transmitting mode:              Keep the EUT in transmitting mode with modulation (new battery used)
    Pre—Test Mode:
    CCIS has verified the construction and function in typical operation, The EUT was placed on three different
       polar directions; i.e. X axis, Y axis, Z axis. which was shown in this test report and defined as follows:
                Axis                            X                         Y                          Z
     Field Strength(dBuV/m)                 78.91                        79.44                     78.68
    Final Test Mode:
    According to ANSI C63.4 standards, the test results are both the "worst case" and "worst setup": X axis
    (see the test setup photo)


5.4 Description of Support Units
      N/A




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1804121
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 5 of 25


                                                                                 Report No: CCISE180412101

5.5      Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
         FCC - Registration No.: 727551
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
        (Federal Communications Commission). The Registration No. is 727551.
         IC - Registration No.: 10106A-1
        The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
        Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
        Registration No.: 10106A-1.
         CNAS - Registration No.: CNAS L6048
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of testing.
        The Registration No. is CNAS L6048.
         A2LA - Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.6 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com

5.7 Measurement Uncertainty
                      Items                                         Expanded Uncertainty (Confidence of 95%)
       Conducted Emission (9kHz ~ 30MHz)                                        2.14 dB (k=2)
        Radiated Emission (9kHz ~ 30MHz)                                        4.24 dB (k=2)
      Radiated Emission (30MHz ~ 1000MHz)                                       4.35 dB (k=2)
       Radiated Emission (1GHz ~ 18GHz)                                         4.44 dB (k=2)
      Radiated Emission (18GHz ~ 26.5GHz)                                       4.56 dB (k=2)

5.8 Test Instruments list
                                                                                             Cal. Date    Cal. Due date
       Test Equipment             Manufacturer             Model No.      Inventory No.
                                                                                            (mm-dd-yy)     (mm-dd-yy)
      EMI Test Receiver        Rohde & Schwarz               ESCI          CCIS0002        03-07-2018     03-06-2019
                               SCHWARZBECK
    BiConiLog Antenna                                     VULB9163         CCIS0005        03-07-2018     03-06-2019
                             MESS-ELEKTRONIK
 Double-ridged waveguide       SCHWARZBECK
                                                         BBHA9120D         CCIS0006        03-07-2018     03-06-2019
        horn antenna         MESS-ELEKTRONIK
          Amplifier
                                       HP                   8447D          CCIS0003        03-07-2018     03-06-2019
      (10kHz-1.3GHz)
          Amplifier          Compliance Direction
                                                          PAP-1G18         CCIS0011        03-07-2018     03-06-2019
       (1GHz-18GHz)               Systems Inc.
    Spectrum analyzer          Rohde & Schwarz               FSP           CCIS0023        03-07-2018     03-06-2019




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                 Page 6 of 25


                                                                           Report No: CCISE180412101

6      Test results and Measurement Data
6.1 Antenna requirement
        Standard requirement:          FCC Part15 C Section 15.203
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        E.U.T Antenna:
       The EUT make use of an PCB antenna, The typical gain of the antenna is 0dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 7 of 25


                                                                                   Report No: CCISE180412101

6.2 Radiated Emission
        Test Requirement:               FCC Part15 C Section 15.231(a) and 15.209
        Test Method:                    ANSI C63.4:2014
        Test Frequency Range:           30MHz to 5000MHz
        Test site:                      Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                  Frequency         Detector           RBW         VBW           Remark
                                        30MHz-1GHz        Quasi-peak         120kHz      300kHz     Quasi-peak Value
                                        Above 1GHz          Peak              1MHz        3MHz        Peak Value
        Limit:                                 Frequency                 Limit (dBuV/m @3m)           Remark
        (Field strength of the                                                  75.6               Average Value
        fundamental signal)                     314.35MHz
                                                                                  95.6              Peak Value
        Limit:                                  Frequency                Limit (dBuV/m @3m)           Remark
        (Spurious Emissions)                  30MHz-88MHz                         40.0            Quasi-peak Value
                                             88MHz-216MHz                         43.5            Quasi-peak Value
                                            216MHz-960MHz                         46.0            Quasi-peak Value
                                              960MHz-1GHz                         54.0            Quasi-peak Value
                                                                                  54.0             Average Value
                                              Above 1GHz
                                                                                  74.0              Peak Value
                                        Or The maximum permitted unwanted emission level is 20 dB below the
                                         maximum permitted fundamental level whichever limit permits higher field
                                         strength.
        Test Procedure:                 a. The EUT was placed on the top of a rotating table 0.8m(below 1GHz)
                                             /1.5m(above 1GHz) above the ground at a 3 meter chamber. The
                                             table was rotated 360 degrees to determine the position of the highest
                                             radiation.
                                        b. The EUT was set 3 meters away from the interference-receiving
                                             antenna, which was mounted on the top of a variable-height antenna
                                             tower.
                                        c. The antenna height is varied from one meter to four meters above the
                                             ground to determine the maximum value of the field strength. Both
                                             horizontal and vertical polarizations of the antenna are set to make
                                             the measurement.
                                        d. For each suspected emission, the EUT was arranged to its worst case
                                             and then the antenna was tuned to heights from 1 meter to 4 meters
                                             and the rotatable table was turned from 0 degrees to 360 degrees to
                                             find the maximum reading.
                                        e. The test-receiver system was set to Peak Detect Function and
                                             Specified Bandwidth with Maximum Hold Mode.
                                        f. If the emission level of the EUT in peak mode was 10dB lower than
                                             the limit specified, then testing could be stopped and the peak values
                                             of the EUT would be reported. Otherwise the emissions that did not
                                             have 10dB margin would be re-tested one by one using peak, quasi-
                                             peak or average method as specified and then reported in a data
                                             sheet.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 8 of 25


                                                                           Report No: CCISE180412101

        Test setup:                     Below 1GHz




                                        Above 1GHz




        Test Instruments:               Refer to section 5.7 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                   Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                      Page 9 of 25


                                                                                     Report No: CCISE180412101

   6.2.1 Field Strength Of The Fundamental Signal
                                                          Peak value
                  Read          Antenna                         Preamp                                   Over
Frequency                                    Cable Loss                       Level      Limit Line
                  Level          Factor                          Factor                                  Limit      Polarization
  (MHz)                                         (dB)                        (dBuV/m)     (dBuV/m)
                 (dBuV)          (dB/m)                           (dB)                                   (dB)
 314.35          60.25           13.51           2.98             0.00       76.74          95.58       -18.84        Vertical
 314.35          62.95           13.51           2.98             0.00       79.44          95.58       -16.14      Horizontoal
                                                        Average value
Frequency          Level       Duty Cycle          Average value               Limit Line           Over Limit
                                                                                                                    Polarization
  (MHz)          (dBuV/m)        factor              (dBuV/m)                  (dBuV/m)               (dB)
 314.35           76.74           -5.46                 71.28                    75.58                -4.30           Vertical
 314.35           79.44           -5.46                 73.98                    75.58                -1.60          Horizontal

                          Duty cycle factor = 20log(Duty cycle)
Calculate Formula:
                          Duty cycle =T on time/100 milliseconds or period, whichever is less
                          T on time =(28*0.82)(ms)+(19*1.6)(ms)=53.36(ms)
                          T period =446(ms)>100(ms)
    Test data:
                          Duty cycle =53.36%
                          Duty cycle factor = 20log(Duty cycle) = -5.46




   Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1804121
   No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
   Bao’an District, Shenzhen, Guangdong, China
   Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                  Page 10 of 25


                                                                                                                                            Report No: CCISE180412101


                                        T on time slot-1:                                                                                     T on time slot-2

                                                          RBW 1 MHz          Delta 1 [T1 ]                                                                      RBW 1 MHz          Delta 1 [T1 ]
                                                         * VBW   1 MHz                    0.30 dB                                                              * VBW   1 MHz                  -0.95 dB
              Ref    20.5 dBm         * Att   30 dB       SWT 10 ms                 820.000000 µs                   Ref    20.5 dBm         * Att   30 dB       SWT 10 ms                  1.600000 ms

              20    Offset   0.5 dB                                          Marker 1 [T1 ]                         20    Offset   0.5 dB                                          Marker 1 [T1 ]
                                                                                        -57.40 dBm                                                                                           -58.27 dBm
                                                                                      6.900000 ms    A                                                                                     3.860000 ms    A
              10                                                                                                    10
                                                                                                     SGL                                                                                                  SGL
     1 PK *                                                                                                1 PK *
     CLRWR                                                                                                 CLRWR
              0                                                                                      LVL
                                                                                                                    0                                                                                     LVL



              -10                                                                                                   -10



              -20                                                                                                   -20



              -30                                                                                                   -30

                                                                                                     3DB                                                                                                  3DB

              -40                                                                                                   -40



              -50                                                                                                   -50
                                                                         1      1
                                                                                                                                                    1            1
              -60                                                                                                   -60



              -70                                                                                                   -70




              Center 314.35 MHz                       1 ms/                                                         Center 314.35 MHz                        1 ms/




     Date: 9.MAY.2018           12:06:00                                                                   Date: 9.MAY.2018           12:06:58




                                                 T 100ms:                                                                                               T period

                                                          RBW 1 MHz                                                                                             RBW 1 MHz          Delta 1 [T1 ]
                                                         * VBW   1 MHz                                                                                         * VBW   1 MHz                  -1.26 dB
              Ref    20.5 dBm         * Att   30 dB       SWT 100 ms                                                Ref    0 dBm            * Att   10 dB       SWT 1 s                  446.000000 ms

              20    Offset   0.5 dB                                                                                 0                                                              Marker 1 [T1 ]
                                                                                                                                                                                             -75.24 dBm
                                                                                                     A                                                                                   242.000000 ms    A
              10                                                                                                    -10
                                                                                                     SGL                                                                                                  SGL
     1 PK *                                                                                                1 PK
     CLRWR                                                                                                 MAXH
              0                                                                                                     -20
                                                                                                     LVL



              -10                                                                                                   -30




              -20                                                                                                   -40



              -30                                                                                                   -50


                                                                                                     3DB                                                                                                  3DB

              -40                                                                                                   -60




              -50                                                                                                   -70
                                                                                                                                        1
                                                                                                                                                                               1


              -60                                                                                                   -80




              -70                                                                                                   -90


                                                                                                                    -100

              Center 314.35 MHz                       10 ms/                                                        Center 314.35 MHz                       100 ms/




     Date: 9.MAY.2018           12:07:33                                                                   Date: 7.MAY.2018           21:15:38




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                                 Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                                           Page 11 of 25


                                                                             Report No: CCISE180412101

  6.2.2 Spurious Emissions
                                              Below 1GHz (30MHz-1000MHz)
               Read       Antenna     Cable                                  Limit
Frequency                                                Level
               Level       Factor     Loss                                   Line           Detector         polarization
  (MHz)                                                (dBuV/m)
             (dBuV/m)      (dB/m)      (dB)                                (dBuV/m)
 628.70        18.36        18.58      3.89              40.83              55.58             QP               Vertical
 943.05        16.89        21.51      4.16              42.56              55.58             QP               Vertical
 628.70        16.57        18.58      3.89              39.04              55.58             QP             Horizontal
 943.05        16.42        21.51      4.16              42.09              55.58             QP             Horizontal




  Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                        Project No.: CCISE1804121
  No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
  Bao’an District, Shenzhen, Guangdong, China
  Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 12 of 25


 CCIS                                                                               Report No: CCISE180412101




                                                         Above 1GHz
                                                           Peak value
                  Read        Antenna       Cable        Aux       Pream                             wl
Frmf_'ezr;cy      Level        Factor       Loss        Factor      Factorp   (dléi\\';lm)    fi!\gtl\r/?r';)     polarization
                (dBuV/m)       (dB/m)        (dB)        (dB)         (dB)
 1257.40          45.82        23.90        3.40         2.45        41.05      34.52            55.58             Vertical
 1571.75          45.68        24.80        3.81         2.22        41.03      35.48            55.58             Vertical
 1886.10          45.62        24.85        4.21         2.45        41.40      35.73            55.58             Vertical
 2200.45          45.49        25.00        4.50         2.70        41.68      36.01           55.58              Vertical
 2514.80          45.69        25.75        4.84         2.85        41.90      37.28            55.58             Vertical
 2829.15          45.63        26.70        5.17         2.89        41.63      38.76           55.58              Vertical
 3143.50          46.10        27.28        5.40         2.92        41.48      40.27            55.58             Vertical
 1257.40          46.35        23.90        3.40         2.45        41.05      35.05            55.58            Horizontal
 1571.75          46.56        24.80        3.81         2.22        41.08      36.36           55.58             Horizontal
 1886.10          45.32        24.85        4.21         2.45        41.41      35.42            55.58            Horizontal
 2200.45          46.37        25.00        4.50         2.70        41.68      36.89            55.58            Horizontal
 2514.80          46.05        25.75        4.84         2.85        41.90      37.59            55.58            Horizontal
 2829.15          46.21        26.70        5.17         2.89        41.63      39.34            55.58            Horizontal
 3143.50          45.89        27.28        5.40         2.92        41.43      40.06            55.58            Horizontal




  Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1804121
  No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
  Bac‘an District, Shenzhen, Guangdong, China
  Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 13 of 25


                                                                               Report No: CCISE180412101

6.3 20dB Bandwidth
        Test Requirement:                FCC Part15 C Section 15.231 (c)
        Test Method:                     ANSI C63.4:2014
        Receiver setup:                  RBW=1kHz, VBW=3kHz, detector: Peak
        Limit:                           The bandwidth of the emission shall be no wider than 0.25% of the center
                                         frequency for devices operating above 70 MHz and below 900 MHz. For
                                         devices operating above 900 MHz, the emission shall be no wider than
                                         0.5% of the center frequency. Bandwidth is determined at the points 20
                                         dB down from the modulated carrier.
        Test Procedure:                  1. According to the follow Test-setup, keep the relative position between
                                            the artificial antenna and the EUT.
                                         2. Set the EUT to proper test channel.
                                         3. Max hold the radiated emissions, mark the peak power frequency
                                            point and the -20dB upper and lower frequency points.
                                         4. Read 20dB bandwidth.
        Test setup:




        Test Instruments:                Refer to section 5.7 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data
        20dB bandwidth (MHz)                           Limit (MHz)                           Results
                 0.010                                    0.7859                             Passed

Note: Limit= Fundamental frequency×0.25%=314.35×0.25%=0.7859MHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 14 of 25


                                                                                                      Report No: CCISE180412101

Test plot as follows:
                                                                          * RBW   1 kHz   Delta 1 [T1 ]
                                                                          * VBW   3 kHz               1.79 dB
                           Ref    1 dBm               * Att   10 dB          SWT 500 ms       10.000000000 kHz

                           0     Offset    1 dB                                           Marker 1 [T1 ]
                                                                                                    -43.24 dBm
                                                                                             314.355000000 MHz    A
                           -10

                    1 PK
                    MAXH
                                    D1 -19.25 dBm
                           -20                                                                                   LVL




                           -30



                                          D2 -39.25 dBm                      1
                           -40                                           1



                           -50

                                                                                                                 3DB

                           -60



                           -70



                           -80



                           -90




                           Center 314.35 MHz                          50 kHz/                     Span 500 kHz




                    Date: 27.APR.2018             14:51:26




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                     Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                        Page 15 of 25


                                                                              Report No: CCISE180412101

6.4 Duration Time
        Test Requirement:                FCC Part15 C Section 15.231 (a)
        Test Method:                     ANSI C63.10: 2013
        Receiver setup:                  RBW=100kHz, VBW=300kHz, span=0Hz, detector: Peak
        Limit:                           Not more than 5 seconds
        Test mode:                       Transmitting mode
        Test Procedure:                  1. According to the follow Test-setup, keep the relative position between
                                            the artificial antenna and the EUT.
                                         2. Set the EUT to proper test channel.
                                         3. Single scan the transmission, and read the transmission time.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data
         Duration time (second)                        Limit (second)                        Result
                   0.496                                   <5.0                               Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 16 of 25


                                                                                                     Report No: CCISE180412101

Test plot as follows:
                                                                      RBW 1 MHz          Delta 2 [T1 ]
                                                                     * VBW   1 MHz                  -0.00 dB
                           Ref       0 dBm        * Att   10 dB       SWT 8 s                    5.000000 s

                           0                                                             Marker 1 [T1 ]
                                                                                                   -75.45 dBm
                                                                                               432.000000 ms     A
                           -10
                                                                                         Delta 1 [T1 ]
                    1 PK
                                                                                                    -0.06 dB
                    MAXH
                           -20                                                                 496.000000 ms



                           -30



                           -40



                           -50


                                                                                                                6DB
                           -60                                                                                  AC




                           -70
                                 1     1                                             2


                           -80



                           -90


                           -100

                           Center 314.35 MHz                      800 ms/




                    Date: 2.MAY.2018         17:04:01




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                    Project No.: CCISE1804121
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                       Page 17 of 25



Document Created: 2018-05-27 17:16:49
Document Modified: 2018-05-27 17:16:49

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC