03 FCC Test Report_15B

FCC ID: 2AOTF-0000008

Test Report

Download: PDF
FCCID_4247789

                                                                                 Test report No.        : 12768053H-A-R1
                                                                                 Page                   : 1 of 19
                                                                                 Issued date            : April 19, 2019
                                                                                 FCC ID                 : 2AOTF-0000008

8




                                  EMI TEST REPORT
                                Test Report No. : 12768053H-A-R1
        Applicant                             :        M-SYSTEM CO., LTD.

        Type of Equipment                     :        MODBUS INTERFACE MODULE

        Model No.                             :        R3-NMW1F-N

        FCC ID                                :        2AOTF-0000008

        Test regulation                       :        FCC Part 15 Subpart B: 2018 Class A

        Test Result                           :        Complied (Refer to SECTION 3.2)
           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with the above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report covers EMC technical requirements. It does not cover administrative issues
                such as Manual or non-EMC test related Requirements. (if applicable)
           6.   The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
           7.   This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
           8.   The information provided from the customer for this report is identified in SECTION 1.
           9.   This report is a revised version of 12768053H-A. 12768053H-A is replaced with this report.

                         Date of test:                             April 1, 2019

                         Representative test
                         engineer:
                                                                Koji Yamamoto
                                                                   Engineer
                                                          Consumer Technology Division


                         Approved by:
                                                              Satofumi Matsuyama
                                                                    Engineer
                                                          Consumer Technology Division

                                                            This laboratory is accredited by the NVLAP LAB CODE
                                                            200572-0, U.S.A. The tests reported herein have been
                                                            performed in accordance with its terms of accreditation.
                                                            *As for the range of Accreditation in NVLAP, you may
                                                            refer to the WEB address,
                                                            http://japan.ul.com/resources/emc_accredited/

       NVLAP LAB CODE: 200572-0

    The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
    There is no testing item of "Non-accreditation".

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                      Report Cover Page - 13-EM-F0429 Issue # 14.0


                                                                     Test report No.      : 12768053H-A-R1
                                                                     Page                 : 2 of 19
                                                                     Issued date          : April 19, 2019
                                                                     FCC ID               : 2AOTF-0000008




                                   REVISION HISTORY
                             Original Test Report No.: 12768053H-A

Revision       Test report No.        Date             Page      Contents
                                                       revised
-              12768053H-A            April 10, 2019   -         -
(Original)
1              12768053H-A-R1         April 19, 2019   P.8       Correction of Remarks in Clause 4.1
1              12768053H-A-R1         April 19, 2019   P.9       Correction of length of Cable No.5 in Clause 4.2;
                                                                 From 2.5 m to 1.0 m




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                              Test report No.            : 12768053H-A-R1
                                                                                              Page                       : 3 of 19
                                                                                              Issued date                : April 19, 2019
                                                                                              FCC ID                     : 2AOTF-0000008


CONTENTS                                                                                                                              PAGE

SECTION 1: Customer information ...................................................................................................... 4
SECTION 2: Equipment under test (E.U.T.) ......................................................................................... 4
SECTION 3: Test specification, procedures & results ......................................................................... 5
SECTION 4: Operation of E.U.T. during testing .................................................................................. 8
SECTION 5: Conducted Emission........................................................................................................ 10
SECTION 6: Radiated Emission ........................................................................................................... 11
APPENDIX 1: Test data ........................................................................................................................ 13
    Conducted Emission ......................................................................................................................... 13
    Radiated emission ............................................................................................................................. 14
APPENDIX 2: Test instruments ........................................................................................................... 16
APPENDIX 3: Photographs of test setup ............................................................................................. 17
    Conducted Emission ......................................................................................................................... 17
    Radiated Emission ............................................................................................................................ 18




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.      : 12768053H-A-R1
                                                                        Page                 : 4 of 19
                                                                        Issued date          : April 19, 2019
                                                                        FCC ID               : 2AOTF-0000008


SECTION 1:         Customer information
Company Name                           :    M-SYSTEM CO., LTD.
Address                                :    5-2-55 MINAMITSUMORI, NISHINARI-KU, OSAKA, 557-0063
                                            JAPAN
Telephone Number                       :    +81-6-6659-8258
Facsimile Number                       :    +81-6-6659-8514
Contact Person                         :    Juri Sugiyama

The information provided from the customer is as follows;
- Applicant, Type of Equipment, Model No. on the cover and other relevant pages
- SECTION 1: Customer information
- SECTION 2: Equipment under test (E.U.T.)
- SECTION 4: Operation of E.U.T. during testing
* The laboratory is exempted from liability of any test results affected from the above information in SECTION 2 and 4.



SECTION 2:         Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

Type of Equipment                      :    MODBUS INTERFACE MODULE
Model No.                              :    R3-NMW1F-N
Serial No.                             :    Refer to Section 4, Clause 4.2
Rating                                 :    DC 20 V (Supply from internal communication bus)
Receipt Date of Sample                 :    March 20, 2019
(Information from test lab.)
Country of Mass-production             :    Japan
Condition of EUT                       :    Engineering prototype
                                            (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                    :    No Modification by the test lab


2.2       Product Description

Model: R3-NMW1F-N (referred to as the EUT in this report) is a MODBUS INTERFACE MODULE.

General Specification

 Clock frequency(ies) in the system    :     40 MHz (Max)

Radio Specification

                                                       IEEE802.15.4g
Frequency of operation                 902 MHz - 928 MHz
Type of modulation                     GFSK
Channel spacing                        0.6 MHz
Antenna type                           Sleeve antenna (model: MH920-ANT-F(S))
                                       Rooftop antenna (model: MH920-ANT-F(R))
Antenna Connector type                 Connector for connecting antenna
Antenna Gain                           3 dBi (max) (Sleeve antenna)
                                       2 dBi (max) (Rooftop antenna)
Clock frequency (maximum)              928 MHz

* The RF module is a FCC certificated module made by Oki Electric Industry Co., Ltd. Model number: MH920-Mod-F
 (FCC ID: 2AKGW-1TD3016A1).


UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                 Test report No.       : 12768053H-A-R1
                                                                                 Page                  : 5 of 19
                                                                                 Issued date           : April 19, 2019
                                                                                 FCC ID                : 2AOTF-0000008


SECTION 3:           Test specification, procedures & results

3.1        Test Specification

Test Specification              :     FCC Part 15 Subpart B
                                      FCC Part 15 final revised on March 12, 2018 and effective April 11, 2018

Title                           :     FCC 47CFR Part15 Radio Frequency Device
                                      Subpart B Unintentional Radiators


3.2        Procedures and results

 Item                  Test Procedure               Limits           Deviation     Worst margin         Result         Remarks
                       FCC: ANSI C63.4: 2014                                       [QP]
                       7. AC power - line                                          17.36 dB
                       conducted emission                                          0.20742 MHz, L       Complied
 Conducted emission                                 Class A          N/A                                               -
                       measurements                                                [AV]                 a)
                       IC: ICES-003 Issue 6: 2016 +                                8.17 dB
                       Amendment 1: 2017                                           22.94240 MHz, L
                       FCC: ANSI C63.4: 2014
                       8. Radiated                                                 3.18 dB
                                                                                                        Complied#
 Radiated emission     emission measurements        Class A          N/A           70.807 MHz,                         -
                                                                                   Vertical, QP
                                                                                                        b)
                       IC: ICES-003 Issue 6: 2016 +
                       Amendment 1: 2017
 *Note: UL Japan, Inc’s EMI Work Procedure 13-EM-W0420.

 a) Refer to APPENDIX 1 (data of Conducted Emission)
 b) Refer to APPENDIX 1 (data of Radiated emission)
 Symbols:
  Complied           The data of this test item has enough margin, more than the measurement uncertainty.
  Complied#          The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.


3.3        Addition to standard

No addition, exclusion nor deviation has been made from the standard.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                 Test report No.        : 12768053H-A-R1
                                                                                 Page                   : 6 of 19
                                                                                 Issued date            : April 19, 2019
                                                                                 FCC ID                 : 2AOTF-0000008


3.4         Uncertainty

There is no applicable rule of uncertainty in this applied standard. Therefore, the following results are derived
depending on whether or not laboratory uncertainty is applied.

The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.


                                     Conducted emission
         Frequency range             using AMN(LISN)
                                            (+/-)
      0.009 MHz to 0.15 MHz                 3.8 dB
      0.15 MHz to 30 MHz                    3.4 dB

                                               Radiated emission (Below 1 GHz)
       Polarity                    (3 m*)(+/-)                                 (10 m*)(+/-)
                    30 MHz to 200 MHz    200 MHz to 1000 MHz    30 MHz to 200 MHz    200 MHz to 1000 MHz
      Horizontal         4.8 dB                5.2 dB                  4.8 dB               5.0 dB
       Vertical          5.0 dB                6.3 dB                  4.9 dB               5.0 dB

                                             Radiated emission (Above 1 GHz)
                 (3 m*)(+/-)                                     (1 m*)(+/-)                             (10 m*)(+/-)
    1 GHz to 6 GHz      6 GHz to 18 GHz        10 GHz to 26.5 GHz      26.5 GHz to 40 GHz              1 GHz to 18 GHz
         5.0 dB              5.3 dB                   5.8 dB                 5.8 dB                         5.2 dB
* Measurement distance




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                               Test report No.         : 12768053H-A-R1
                                                                               Page                    : 7 of 19
                                                                               Issued date             : April 19, 2019
                                                                               FCC ID                  : 2AOTF-0000008


3.5         Test Location

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967
                                                                                                                    Maximum
                     IC Registration Width x Depth x      Size of reference ground plane (m)
Test site                                                                                    Other rooms            measuremen
                     Number          Height (m)           / horizontal conducting plane
                                                                                                                    t distance
No.1 semi-anechoic                                                                               No.1 Power
                     2973C-1         19.2 x 11.2 x 7.7    7.0 x 6.0                                                 10 m
chamber                                                                                          source room
No.2 semi-anechoic
                     2973C-2         7.5 x 5.8 x 5.2      4.0 x 4.0                              -                  3m
chamber
No.3 semi-anechoic                                                                               No.3 Preparation
                     2973C-3         12.0 x 8.5 x 5.9     6.8 x 5.75                                                3m
chamber                                                                                          room
No.3 shielded room   -               4.0 x 6.0 x 2.7      N/A                                    -                  -
No.4 semi-anechoic                                                                               No.4 Preparation
                     2973C-4         12.0 x 8.5 x 5.9     6.8 x 5.75                                                3m
chamber                                                                                          room
No.4 shielded room   -               4.0 x 6.0 x 2.7      N/A                                    -                  -
No.5 semi-anechoic
                     -               6.0 x 6.0 x 3.9      6.0 x 6.0                              -                  -
chamber
No.6 shielded room   -               4.0 x 4.5 x 2.7      4.0 x 4.5                              -                  -
No.6 measurement
                     -               4.75 x 5.4 x 3.0     4.75 x 4.15                            -                  -
room
No.7 shielded room   -               4.7 x 7.5 x 2.7      4.7 x 7.5                              -                  -
No.8 measurement
                     -               3.1 x 5.0 x 2.7      3.1 x 5.0                              -                  -
room
No.9 measurement
                     -               8.8 x 4.6 x 2.8      2.4 x 2.4                              -                  -
room
No.11 measurement
                     -               6.2 x 4.7 x 3.0      4.8 x 4.6                              -                  -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0 m for No.1, No.2, No.3, and No.4
semi-anechoic chambers and No.3 and No.4 shielded rooms.



3.6         Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                         Test report No.                 : 12768053H-A-R1
                                                                                                         Page                            : 8 of 19
                                                                                                         Issued date                     : April 19, 2019
                                                                                                         FCC ID                          : 2AOTF-0000008


SECTION 4:         Operation of E.U.T. during testing
4.1       Operating Mode(s)

Mode                                            Remarks
1) Normal Operation mode                        The following operations are performed under the Normal Operation mode.
                                                -    Wireless Communication mode
                                                -    Wired Communication mode


4.2       Configuration and peripherals



                                                                            L

                                        I               H           C       A                     1                  D               E


                                                6                           F                    G                           2

                                                            7                            4                   5                            3
                                                J


                                8

                            K                                               B

                  10            9
                                                                                                 AC 120V/60Hz *a)            AC 120V/60Hz



                 AC 100V/60Hz                                                                                              : Standard Ferrite Core


                                                                                L’

                                                                                    11

                                            I               H           C       A                     1                  D               E


                                                    6                           F                    G                           2

                                                                7                            4                   5                            3
                                                    J


                                    8

                                K                                               B

                       10           9
                                                                                                     AC 120V/60Hz *a)            AC 120V/60Hz



                    AC 100V/60Hz                                                                                             : Standard Ferrite Core


* Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions.
*a) Conducted emission test was performed on this port.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                    Test report No.       : 12768053H-A-R1
                                                                    Page                  : 9 of 19
                                                                    Issued date           : April 19, 2019
                                                                    FCC ID                : 2AOTF-0000008


Description of EUT and Support equipment
 No. Item                          Model number          Serial number Manufacturer                  Remarks
 A     MODBUS INTERFACE            R3-NMW1F-N            P-38109          M-SYSTEM CO., LTD.         EUT
       MODULE
 B     THERMOCOUPLE                R3-TS8A               P-37576          M-SYSTEM CO., LTD.         -
       INPUT MODULE
 C     BASE                        R3-BS06               71044542         M-SYSTEM CO., LTD.         -
 D     MODBUS I/O MODULE R7M-DA16F-R                     6K019029         M-SYSTEM CO., LTD.         -
 E     DC Power Supply             MDC6-12024A-M2 8I002105                M-SYSTEM CO., LTD.         -
 F     Power Supply Module         R3-PS1-R              JX008418         M-SYSTEM CO., LTD.         -
 G     DC Power Supply             MDC5-06024A-M2 5C036884                M-SYSTEM CO., LTD.         -
 H     WIRELESS GATEWAY WL40EW2F-R                       P-35078          M-SYSTEM CO., LTD.         -
 I     DC Power Supply             MDC5-06024A-M2 2L013871                M-SYSTEM CO., LTD.         -
 J     Laptop PC                   2672-C2J              99-PPBKH         IBM                        -
 K     AC Adapter                  08K8212               7UB4160FD        IBM                        -
 L     Sleeve antenna              MH920-ANT-F(S)        001              OKI                        EUT *1)
 L’    Rooftop antenna             MH920-ANT-F(R) 001                     OKI                        EUT *1)
*1) The test was performed with Sleeve antenna which has been found to be worst in pre-check.

List of cables used
 No. Name                        Length (m)                        Shield                          Remarks
                                                        Cable                Connector
 1     Modbus Cable              1.0                   Shielded               Shielded         -
 2     DC Cable                  0.5                  Unshielded             Unshielded        -
 3     AC Cable                  1.0                  Unshielded             Unshielded        -
 4     DC Cable                  0.5                  Unshielded             Unshielded        -
 5     AC Cable                  1.0                  Unshielded             Unshielded        -
 6     DC Cable                  0.5                  Unshielded             Unshielded        -
 7     LAN Cable                 2.0                  Unshielded             Unshielded        -
 8     DC Cable                  2.0                   Shielded               Shielded         -
 9     AC Cable                  1.0                  Unshielded             Unshielded        -
 10    AC Cable                  1.5                  Unshielded             Unshielded        -
 11    Antenna Cable             2.5                   Shielded               Shielded         -




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.      : 12768053H-A-R1
                                                                         Page                 : 10 of 19
                                                                         Issued date          : April 19, 2019
                                                                         FCC ID               : 2AOTF-0000008


SECTION 5: Conducted Emission
5.1    Operating environment

Test place           : No.1 semi anechoic chamber
Temperature          : See data
Humidity             : See data


5.2    Test configuration

EUT was placed on a urethane platform of nominal size, 1.0 m by 1.5 m, raised 0.8 m above the conducting ground
plane.
The rear of tabletop was located 40 cm to the vertical conducting plane. The rear of EUT and its peripherals was aligned and
flushed with rear of tabletop. All other surfaces of tabletop were at least 80 cm from any other grounded conducting surface.
EUT was located 80 cm from the LISN/AMN and excess AC cable was bundled in center. I/O cables that were connected to
the other peripherals were bundled in center. They were folded back and forth forming a bundle 30 cm to 40 cm long and were
hanged at a 40 cm height to the ground plane. Each EUT current-carrying power lead, except the ground (safety) lead, was
individually connected through a LISN/AMN to the input power source. All unused 50 ohm connectors of the LISN/AMN
were resistivity terminated in 50 ohm when not connected to the measuring equipment.
Photographs of the set up are shown in Appendix 3.

Frequency range    : 0.15 MHz - 30 MHz
EUT position       : Table top
EUT operation mode : See Clause 4.1


5.3    Test procedure

The AC Mains Terminal Continuous disturbance Voltage has been measured with the EUT within a semi anechoic
chamber. The EUT was connected to a Line Impedance Stabilization Network (LISN)/ Artificial Mains network
(AMN). An overview sweep with peak detection has been performed. The measurements have been performed with
a quasi-peak detector and if required, with an average detector.
The conducted emission measurements were made with the following detector function of the test receiver.
    Detector Type               : Quasi-Peak and CISPR AV
    IF Bandwidth                : 9 kHz


Figure 1: Test Setup

                                                   EUT



                                 Attenuator
      Test
      receiver                        LISN

                                                      Ground plane

5.4    Test result

Summary of the test results: Pass

The test result is rounded off to one or two decimal places, so some differences might be observed.

Date: April 1, 2019 (Night)              Test engineer:       Koji Yamamoto


UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.      : 12768053H-A-R1
                                                                        Page                 : 11 of 19
                                                                        Issued date          : April 19, 2019
                                                                        FCC ID               : 2AOTF-0000008


SECTION 6:         Radiated Emission
6.1   Operating environment

Test place          : No.1 semi anechoic chamber
Temperature         : See data
Humidity            : See data


6.2   Test configuration

EUT was placed on a urethane platform of nominal size, 1.0 m by 1.5 m, raised 0.8 m above the conducting ground
plane.
The EUT was set on the edge of the tabletop.
Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement
antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.
Photographs of the set up are shown in Appendix 3.


6.3   Test conditions

Frequency range         :    30 MHz - 200 MHz (Biconical antenna) / 200 MHz - 1000 MHz (Logperiodic antenna)
                             1000 MHz - 10000 MHz (Horn antenna)
Test distance           :    10 m (30 MHz - 1000 MHz) / 3 m (1000 MHz - 10000 MHz)
EUT position            :    Table top
EUT operation mode      :    See Clause 4.1


6.4   Test procedure

The height of the measuring antenna varied between 1 and 4 m and EUT was rotated a full revolution in order to obtain
the maximum value of the electric field intensity.
The measurements were performed for both vertical and horizontal antenna polarization with the Test Receiver.
The radiated emission measurements were made with the following detector function of the Test Receiver.

   Frequency            Below 1GHz                     Above 1GHz *1)
   Instrument used      Test Receiver                  Test Receiver
   IF Bandwidth         QP: BW 120 kHz                 PK: BW 1 MHz, CISPR AV: BW 1 MHz
*1) The measurement data was adjusted to a 10 m distance using the following Distance Factor.
    Distance Factor: 20 x log (3.6 m / 10 m) = -8.9 dB




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.        : 12768053H-A-R1
                                                                          Page                   : 12 of 19
                                                                          Issued date            : April 19, 2019
                                                                          FCC ID                 : 2AOTF-0000008


Figure 2: Test Setup

Below 1 GHz
                                                              Test Distance: 10 m




                      10 m




1 GHz - 10 GHz
                                                              Distance Factor: 20 x log (3.6 m*/10.0 m) = -8.9 dB
                                                              * Test Distance: (3 + Test Volume /2) - r = 3.6 m

                                                              Test Volume: 2 m
                                                              (Test Volume has been calibrated based on CISPR 16-1-4.)
                                                               r = 0.4 m




The test was made on EUT at the normal use position.


6.5     Test result

Summary of the test results: Pass

The limit is rounded down to one decimal place.
The test result is rounded off to one or two decimal places, so some differences might be observed.


Date:      April 1, 2019 (Day)               Test engineer:            Shinya Watanabe
           April 1, 2019 (Night)                                       Koji Yamamoto




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                                                       Test report No.                  : 12768053H-A-R1
                                                                                                                                       Page                             : 13 of 19
                                                                                                                                       Issued date                      : April 19, 2019
                                                                                                                                       FCC ID                           : 2AOTF-0000008


APPENDIX 1: Test data

                                                                                           Conducted Emission

             Report No.                                                       12768053H
             Test place                                                       Ise EMC Lab.
             Semi Anechoic Chamber                                            No.1
             Date                                                             April 1, 2019 (Night)
             Temperature / Humidity                                           22 deg. C / 33 % RH
             Engineer                                                         Koji Yamamoto
             Mode                                                             Mode 1

                  Limit :                  FCC_Part 15 Subpart B(15.107)_Class A




                                     100
                                                                                                                                                                        Limit1(QP)
                                                                                                                                                                        Limit2(AV)
                                      90
                                                                                                                                                                        N (PK)
                                                                                                                                                                        N (QP/AV)
                                      80
                                                                                                                                                                        L (PK)

                                      70                                                                                                                                L (QP/AV)
                RFI Voltage [dBuV]




                                      60


                                      50


                                      40


                                      30


                                      20


                                      10


                                       0
                                               .2M     .3M           .5M      .7M       1M              2M      3M         5M     7M     10M               20M
                                       .15M                                                                                                                       30M
                                                                                                   Frequency [Hz]



                                                     Reading                                      Results           Limit           Margin
                                      Freq.                            LISN         LOSS
                        No.                       <QP>     <AV>                               <QP>     <AV> <QP>         <AV> <QP>       <AV>      Phase     Comment
                                      [MHz]      [dBuV] [dBuV]         [dB]         [dB]     [dBuV] [dBuV] [dBuV] [dBuV]        [dB]      [dB]
                                1     0.15000      32.30      9.90       0.05        13.07     45.42      23.02 79.00     66.00  33.58     42.98    N
                                2     0.20742      48.30     36.50       0.05        13.09     61.44      49.64 79.00     66.00  17.56     16.36    N
                                3     0.27702      38.70     26.30       0.03        13.11     51.84      39.44 79.00     66.00  27.16     26.56    N
                                4     0.34488      33.60     23.70       0.03        13.12     46.75      36.85 79.00     66.00  32.25     29.15    N
                                5     0.56934      32.30     32.10       0.03        13.16     45.49      45.29 73.00     60.00  27.51     14.71    N
                                6    22.94240      36.80     36.70       0.56        14.47     51.83      51.73 73.00     60.00  21.17      8.27    N
                                7     0.15000      31.90     10.30       0.05        13.07     45.02      23.42 79.00     66.00  33.98     42.58    L
                                8     0.20742      48.50     37.40       0.05        13.09     61.64      50.54 79.00     66.00  17.36     15.46    L
                                9     0.27702      38.90     27.50       0.03        13.11     52.04      40.64 79.00     66.00  26.96     25.36    L
                               10     0.34488      33.70     24.40       0.03        13.12     46.85      37.55 79.00     66.00  32.15     28.45    L
                               11     0.56934      32.30     32.20       0.03        13.16     45.49      45.39 73.00     60.00  27.51     14.61    L
                               12    22.94240      37.00     36.80       0.56        14.47     52.03      51.83 73.00     60.00  20.97      8.17    L




  CHART: WITH FACTOR Peak hold data. CALCULATION : RESULT = READING + C.F (LISN + CABLE + ATT)
  Except for the above table: adequate margin data below the limits.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                                                         Test report No.                      : 12768053H-A-R1
                                                                                                                                         Page                                 : 14 of 19
                                                                                                                                         Issued date                          : April 19, 2019
                                                                                                                                         FCC ID                               : 2AOTF-0000008


                                                                                                 Radiated emission

             Report No.                                                            12768053H
             Test place                                                            Ise EMC Lab.
             Semi Anechoic Chamber                                                 No.1
             Date                                                                  April 1, 2019 (Day)
             Temperature / Humidity                                                21 deg. C / 31 % RH
             Engineer                                                              Shinya Watanabe
                                                                                   (Below 1 GHz)
             Mode                                                                  Mode 1

               Limit :                             FCC_Part 15 Subpart B(15.109)_Class A




                                              70
                                                                                                                                                                                 Limit1(QP)


                                              60
               Field Strength [dBuV/m]




                                              50


                                              40


                                              30


                                              20


                                              10


                                              0
                                                                 50         70        100                     200            300           500        700
                                               30                                                                                                                   1000
                                                                                                  Frequency [MHz]

                                                                Reading                                                         Result                                    Limit       Margin
                                                     Freq.                  Ant.      Ant.Fac     Loss     Gain     S.Fac                 Height    Angle   Pola.
                              No.                                <QP>                                                           <QP>                                     <QP>         <QP>
                                                                            Type
                                                    [MHz]       [dBuV]                [dB/m]      [dB]     [dB]     [dB]      [dBuV/m]    [cm]      [deg]   [H/V]      [dBuV/m]        [dB]
                                          1            68.722       39.50    BA           6.73      8.08    39.00     0.00          15.31     400      188 Hori.              39.10         23.79
                                          2            70.807       44.40    BA           6.51      8.11    39.00     0.00          20.02     400      151 Hori.              39.10         19.08
                                          3            74.969       41.60    BA           6.32      8.18    39.01     0.00          17.09     400       48 Hori.              39.10         22.01
                                          4            87.465       42.80    BA           7.54      8.37    39.04     0.00          19.67     400      162 Hori.              39.10         19.43
                                          5           206.998       45.40   LA20         11.01      9.82    39.09     0.00          27.14     383       13 Hori.              43.50         16.36
                                          6           208.998       45.10   LA20         11.02      9.84    39.08     0.00          26.88     387         0 Hori.             43.50         16.62
                                          7           402.484       42.60   LA20         15.71     11.51    38.62     0.00          31.20     219       72 Hori.              46.40         15.20
                                          8           524.786       41.40   LA20         17.68     12.37    38.50     0.00          32.95     232      154 Hori.              46.40         13.45
                                          9           528.962       41.00   LA20         17.60     12.40    38.49     0.00          32.51     248      146 Hori.              46.40         13.89
                                         10            68.722       57.70    BA           6.73      8.08    39.00     0.00          33.51     179      292 Vert.              39.10          5.59
                                         11            70.807       60.30    BA           6.51      8.11    39.00     0.00          35.92     147      261 Vert.              39.10          3.18
                                         12            74.969       59.50    BA           6.32      8.18    39.01     0.00          34.99     159       87 Vert.              39.10          4.11
                                         13            87.465       58.80    BA           7.54      8.37    39.04     0.00          35.67     135      233 Vert.              39.10          3.43
                                         14           206.998       50.30   LA20         11.01      9.82    39.09     0.00          32.04     100         0 Vert.             43.50         11.46
                                         15           208.998       50.80   LA20         11.02      9.84    39.08     0.00          32.58     100         0 Vert.             43.50         10.92
                                         16           402.484       41.10   LA20         15.71     11.51    38.62     0.00          29.70     100       60 Vert.              46.40         16.70
                                         17           524.786       42.70   LA20         17.68     12.37    38.50     0.00          34.25     100      138 Vert.              46.40         12.15
                                         18           528.962       41.90   LA20         17.60     12.40    38.49     0.00          33.41     100       53 Vert.              46.40         12.99




CHART: WITH FACTOR
ANT TYPE: - 30 MHz: LOOP, 30 MHz - 200 MHz: BICONICAL, 200 MHz - 1000 MHz: LOGPERIODIC, 1000 MHz -: HORN
CALCULATION: RESULT = READING + ANT FACTOR + LOSS & GAIN (CABLE + ATT - GAIN(AMP))




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                                                 Test report No.                 : 12768053H-A-R1
                                                                                                                                 Page                            : 15 of 19
                                                                                                                                 Issued date                     : April 19, 2019
                                                                                                                                 FCC ID                          : 2AOTF-0000008


                                                                                           Radiated emission

             Report No.                                                      12768053H
             Test place                                                      Ise EMC Lab.
             Semi Anechoic Chamber                                           No.1
             Date                                                            April 1, 2019 (Night)
             Temperature / Humidity                                          22 deg. C / 33 % RH
             Engineer                                                        Koji Yamamoto
                                                                             (Above 1 GHz)
             Mode                                                            Mode 1

                Limit :                            FCC_Part 15 Subpart B(15.109)_Class A




                                              100
                                                                                                                                                                    Limit1(AV)
                                                                                                                                                                    Limit2(PK)
                                              90

                                              80                                                                                                                    Hori.(PK/AV)
                Field Strength [dBuV/m]




                                              70                                                                                                                    Vert.(PK/AV)


                                              60

                                              50

                                              40

                                              30

                                              20

                                              10

                                               0
                                                                                 2000               3000                5000           7000
                                               1000                                                                                                    10000
                                                                                                 Frequency [MHz]

                                                             Reading                                            Result                                Limit             Margin
                                                Freq.                     Ant.    Ant.Fac Loss    Gain   S.Fac               Height Angle Pola.
                        No.                               <PK>    <AV>                                     <PK>      <AV>                       <AV>        <PK>   <AV>      <PK>
                                                                          Type
                                                [MHz]    [dBuV] [dBuV]            [dB/m] [dB] [dB] [dB] [dBuV/m] [dBuV/m] [cm] [deg] [H/V] [dBuV/m] [dBuV/m] [dB]            [dB]
                                          1     1448.245   51.10    39.40 HA5       26.29 -5.71 37.01 0.00  34.67      22.97   100    122 Hori.   49.50      69.50 26.53       34.83
                                          2     1448.245   50.60    38.70 HA5       26.29 -5.71 37.01 0.00  34.17      22.27   100    281 Vert.   49.50      69.50 27.23       35.33




CHART: WITH FACTOR
ANT TYPE: - 30 MHz: LOOP, 30 MHz - 200 MHz: BICONICAL, 200 MHz - 1000 MHz: LOGPERIODIC, 1000 MHz -: HORN
CALCULATION: RESULT = READING + ANT FACTOR + LOSS & GAIN (CABLE + Filter - GAIN(AMP) + D-factor)




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                  Test report No.          : 12768053H-A-R1
                                                                                  Page                     : 16 of 19
                                                                                  Issued date              : April 19, 2019
                                                                                  FCC ID                   : 2AOTF-0000008


APPENDIX 2: Test instruments
Test Instruments
Test    LIMS ID Description                Manufacturer           Model            Serial            Last          Calibration   Cal Int
Item                                                                                                 Calibration   Due Date
                                                                                                     Date
CE      141537   LISN(AMN)                 Schwarzbeck            NSLK8127         8127-731          7/12/2018     7/31/2019     12
CE      141538   LISN(AMN)                 Schwarzbeck            NSLK8127         8127-732          7/12/2018     7/31/2019     12
CE      141925   Terminator                TME                    CT-01            -                 11/7/2018     11/30/2019    12
CE      141290   Attenuator(13dB)          JFW Industries, Inc.   50FP-013H2 N     -                 12/27/2018    12/31/2019    12
CE      141215   Coaxial Cable             Fujikura/Suhner/TSJ    5D-2W/3D-2W/R    -/01068           6/4/2018      6/30/2019     12
                                                                  G400u/RFM-E421   (Switcher)
                                                                  (SW)
RE      141994   AC1_Semi Anechoic         TDK                    Semi Anechoic    DA-06881          4/4/2018      4/30/2019     12
                 Chamber(SVSWR)                                   Chamber 10m
RE      141585   Pre Amplifier             MITEQ                  MLA-10K01-B01-   1237616           2/8/2019      2/29/2020     12
                                                                  35
RE      141511   Horn Antenna 1-18GHz        Schwarzbeck          BBHA9120D        253               6/4/2018      6/30/2019     12
RE      141297   High Pass Filter(1.1-10GHz) TOKYO KEIKI          TF219CD1         1001              1/10/2019     1/31/2020     12
RE      141393   Microwave Cable             Junkosha             MWX221           1604S254(1 m) /   8/8/2018      8/31/2019     12
                                                                                   1608S088(5 m)
RE      141576   Pre Amplifier             AGILENT              8449B              3008A01671        2/8/2019      2/29/2020     12
RE      141350   Coaxial Cable             Suhner/storm/Agilent -                  -                 6/4/2018      6/30/2019     12
                                           /TSJ
RE      141198   Biconical Antenna         Schwarzbeck          BBA9106            2513              6/1/2018      6/30/2019     12
RE      141264   Logperiodic               Schwarzbeck          VUSLP9111B         911B-189          3/21/2019     3/30/2020     12
                 Antenna(200-1000MHz)
RE      141213   Attenuator(6dB)           Weinschel Corp         2                BK7971            11/5/2018     11/30/2019    12
RE/CE   141566   Thermo-Hygrometer         CUSTOM                 CTH-201          A08Q26            1/11/2019     1/31/2020     12
RE/CE   142226   Measure                   KOMELON                KMC-36           -                 -             -             -
RE/CE   141950   EMI Test Receiver         Rohde & Schwarz        ESU26            100412            6/15/2018     6/30/2019     12
RE/CE   141530   Digital Tester            Fluke Corporation      FLUKE 26-3       78030621          8/21/2018     8/31/2019     12
RE/CE   141152   EMI measurement program   TSJ                    TEPTO-DV         -                 -             -             -
RE/CE   141998   AC1_Semi Anechoic         TDK                    Semi Anechoic    DA-06881          6/18/2018     6/30/2020     24
                 Chamber(NSA)                                     Chamber 10m


*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that Calibration
is not required (e.g. software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

Test item:
          CE: Conducted emission
          RE: Radiated emission




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124



Document Created: 2019-04-23 05:52:55
Document Modified: 2019-04-23 05:52:55

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC