RF exposure evaluation

FCC ID: 2AOSURC100

RF Exposure Info

Download: PDF
FCCID_3745666

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                                FCC ID: 2AOSURC100


                                        RF Exposure Evaluation Report

   1. Product Information

      FCC ID:                                           2AOSURC100
      Product Name                                      Wireless Charger
      Model Number(s)                                   RC100, RC200, RC300
                                                        PCB board, structure and internal of these model(s) are the
      Model Declaration
                                                        same, only model name is different for these models.
      Power Supply                                      DC 5.0V adapter from AC 120V/50Hz or DC 5.0V from USB
      Modulation Type                                   Continuous Wave
      Frequency Range                                   110.0 – 205.0 KHz
      Operation Frequency                               169.0 KHz
      Antenna Type                                      Coil Antenna
      Hardware version                                  RC100 V2.0
      Software version                                  V1.0
      Accessories                                       SAMSUNG Galaxy S7
      Exposure category                                 General population/uncontrolled environment
      EUT Type                                          Production Unit
      Device Type                                       Mobile Device


   2. Evaluation Method

     Per KDB 680106 D01 Section 3. RF Exposure Requirements;
   1) Consumer wireless power transfer devices approved under Part 15 and Part 18 in some cases have to
       demonstrate compliance with RF exposure requirements. The potential for exposure must be assessed
       according to the operating configurations of the wireless system and the exposure conditions of users
       and bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary
       at maximum output power. The RF exposure requirements must be determined in conjunction with
       the device operating characteristics, according to the mobile and portable exposure requirements in
       Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range
       for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively;
       therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the
       FCC rules.
   2) Based on the design and implementation of the power transfer application, it must be clearly identified
       if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of
       at least 20 cm from users and bystanders may qualify for mobile exposure conditions. For some
       conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of
       the rules may apply.
   3) For devices designed for typical desktop applications, such a wireless charging pads, RF exposure
       evaluation should be conducted assuming a user separation distance of 10 cm. E and H field strength
       measurements or numerical modeling may be used to demonstrate compliance. Measurements should
       be made from all sides and the top of the primary/client pair, with the 10 cm measured from the
       center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be
       assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB
       inquiry is required to determine the applicable exposure limits below 100 kHz.
   4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements.

___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 1 of 6


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                                FCC ID: 2AOSURC100

        Existing SAR systems and test procedures are generally intended for measurements above 100 MHz.
        While numerical modeling can be an alternative, the constraints of substantial computational
        resources at low frequencies could introduce further limitations. Under these circumstances, including
        operations below 100 kHz, the Commission may consider a combination of analytical analysis, field
        strength, radiated and conducted power measurements, in conjunction with some limited numerical
        modeling to assess compliance.
   5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be
      adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable
      exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation
      they should contact the FCC Laboratory with sufficient system operating configuration details to
      determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures.
      Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons,
      information on device design, implementation, operating configurations, exposure conditions of users
      and bystanders are needed to determine the evaluation and testing requirements. In addition, the
      influence of nearby objects may also need consideration according to the wireless power transfer
      system implementation; for example, the effects of placing the device, its coils or radiating elements
      on or near metallic surfaces


   3. Evaluation Limit

   3.1 Refer evaluation method

        ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency
        Electromagnetic Fields, 3 kHz to 300 GHz.
        FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v02: RF Exposure Considerations
        for Low Power Consumer Wireless Power Transfer Applications
        FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits.
        FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices
        FCC CFR 47 part 18.107: Indusial, Scientific, and Medical Equipment


   3.2 Limit

          Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure
                 Frequency               Electric Field           Magnetic Field            Power Density            Averaging Time
                Range(MHz)              Strength(V/m)             Strength(A/m)               (mW/cm²)                  (minute)
                                                Limits for Occupational/Controlled Exposure
                   0.3-3.0                     614                      1.63                      *100                        6
                   3.0-30                    1842/f                    4.89/f                   *900/f2                       6
                   30-300                     61.4                      0.163                      1.0                        6
                 300-1,500                      /                         /                      f/300                        6
               1,500-100,000                    /                         /                         5                         6




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 2 of 6


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                                FCC ID: 2AOSURC100



          Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure
                 Frequency               Electric Field           Magnetic Field            Power Density            Averaging Time
                Range(MHz)              Strength(V/m)             Strength(A/m)               (mW/cm²)                  (minute)
                                           Limits for General Population/Uncontrolled Exposure
                  0.3-1.34                     614                      1.63                      *100                         30
                   1.34-30                    824/f                    2.19/f                    *180/f2                       30
                   30-300                     27.5                      0.073                      0.2                         30
                 300-1,500                      /                         /                      f/1500                        30
               1,500-100,000                    /                         /                        1.0                         30

          F=frequency in MHz
          *=Plane-wave equivalent power density


          According to FCC KDB 680106 D01 Section 3. RF Exposure Requirements clause 3 the Emission-Limits
          in the frequency range from 100 KHz to 300 KHz should be assessed versus the limits at 300 KHz in
          Table 1 of CFR 47 – Section1.310 as following (measured distance shall be 10cm from the center of
          the probe to the edge of the device):
                                                      E-filed                          H-filed                         B-filed
                   Frequency                           V/m                              A/m                               uT
              0.3 MHz – 3.0 MHz                         614                            1.613                             2.0
              3.0 MHz – 30 MHz                 824/f (=27.530MHz)               2.19/f (=0.07330MHz)                      --

          A KDB inquire was required to determine/confirm the applicable limits below 100 KHz.


   4. Test Setup Diagram




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 3 of 6


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                                FCC ID: 2AOSURC100



   5. Test Equipment

     Equipment           Manufacturer             Model               Serial no.        Calibrated date          Calibrated Due
   Exposure Level
                             Narda               ELT-400               N-0713              2017-04-03              2018-04-02
       Tester
    B-Field Probe            Narda               ELT-400               M-1154              2017-04-11              2018-04-10


   6. Measurement Procedure

          a) The RF exposure test was performed on 360 degree turn table in anechoic chamber.
          b) The measurement probe was placed at test distance (10cm) which is between the edge of the
          charger and the geometric center of probe.
          c) The turn table was rotated 360d degree to search of highest strength.
          d) The highest emission level was recorded and compared with limit as soon as measurement of each
          points (A, B, C, D, E) were completed.
          e) The EUT were measured according to the dictates of KDB 680106D01v02.


   7. Equipment Approval Considerations
          The EUT does comply with item 5.2 of KDB 680106 D01v02 as follows table;
    Requirements of KDB 680106 D01                           Yes / No         Description
                                                                              The device operate in the frequency range
    Power transfer frequency is less than 1 MHz              Yes
                                                                              110.0 KHz - 205.0 KHz
    Output power from each primary coil is less                               The maximum output power of the primary
                                                             Yes
    than 5 watts                                                              coil is less than 5W.
    The transfer system includes only single
    primary and secondary coils. This includes
    charging systems that may have multiple                                   The transfer system includes only single
                                                             Yes
    primary coils and clients that are able to                                primary and secondary coils.
    detect and allow coupling only between
    individual pairs of coils
    Client device is inserted in or placed directly                           Client device is placed directly in contact
                                                             Yes
    in contact with the transmitter                                           with the transmitter.
    The maximum coupling surface area of the
                                                                              The maximum coupling surface area was
    transmit (charging) device is between 60 cm2             No
                                                                              36.0 cm2<60 cm2
    and 400 cm 2
    Aggregate leakage fields at 10 cm
                                                                              The EUT E-field strength levels at 10cm and
    surrounding the device from all simultaneous
                                                             Yes              H- field strength levels at 10cm are less than
    transmitting coils are demonstrated to be
                                                                              30% the MPE limit.
    less than 30% of the MPE limit.

          In all other cases, unless excluded above, an RF exposure evaluation report must be reviewed and
          accepted through a KDB or PBA inquiry to enable authorization of the equipment. When evaluation is
          required to show compliance; for example, using field strength, power density, SAR measurements or
          computational modeling etc., the specific authorization requirements will be determined based on
          the results of the RF exposure evaluation.


___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 4 of 6


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                                  FCC ID: 2AOSURC100



   8. E and H field Strength

          Test mode: Normal Operation (Charging mode)

          E-Filed Strength at 10 cm from the edges surrounding the EUT
                                              Measured E-Field Strength Values (V/m)                                   FCC E-Field
 Frequency Range
                           Test            Test           Test           Test            Test           Test         Strength Limits
      (MHz)
                         Position A      Position B     Position C     Position D      Position E     Position F         (V/m)
       0.1690                4.21           4.36           4.57            4.31           5.11            4.85             614.0

          H-Filed Strength at 10 cm from the edges surrounding the EUT
                                              Measured H-Field Strength Values (A/m)                                    FCC H-Field
 Frequency Range
                           Test            Test           Test           Test            Test           Test          Strength Limits
      (MHz)
                         Position A      Position B     Position C     Position D      Position E     Position F          (A/m)
       0.1690               0.071           0.066          0.077          0.069           0.096          0.083              1.63


   9. Test Setup Photos




                                10cm




   10. Conclusion

          A minimum safety distance of 10 cm to the antenna is required when the device is charging a smart
          phone. The detected emissions with a distance of 10 cm are below the limitations according to FCC
          KDB 680106 D01 Section 3. RF Exposure Requirement Clause 3.




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 5 of 6


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                                FCC ID: 2AOSURC100


                                                       Revision History

           Revision                        Issue Date                           Revisions                        Revised By
             000                        January 29, 2018                       Initial Issue                     Gavin Liang




                              .........................END OF REPORT.........................




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 6 of 6



Document Created: 2018-01-31 21:09:11
Document Modified: 2018-01-31 21:09:11

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC