Test Report BLE

FCC ID: 2AOSP-U002

Test Report

Download: PDF

RR051-17-103200-3-A Ed. 0




                                          Certification Radio test report

                                                         According to the standard:
                                                           CFR 47 FCC PART 15


                                                             Equipment under test:
                                                               MICRO TRACKER 2


                                                              FCC ID: 2AOSP-U002


                                                                        Company:
                                                                        ABEEWAY




Distribution: Mrs DENIS                                                                         (Company: ABEEWAY)


                                                                                                Number of pages: 29 with 4 appendixes

                                                                          Technical Verification and
       Ed.                    Date                 Modified                   Quality Approval
                                                   Page(s) Name and Function                                                                     Visa
        0                 2-Nov-17                 Creation M. DUMESNIL, Radio Technical Manager
                                                                                                                                                                                      S51 RTY 000 INT 00004 [ 00]




Duplication of this document is only permitted for an integral photographic facsimile. It includes the number of pages referenced here above.
This document is the result of testing a specimen or a sample of the product submitted. It does not imply an assessment of the conformity of the whole manufactured
products of the tested sample.




  Siège Social : Emitech - 3, rue des Coudriers - Z.A. de l’Observatoire - 78180 MONTIGNY LE BX - France
  Siret : 344 545 645 00022 - Tél. : 33 (0)1 30 57 55 55 - Fax : 33 (0)1 30 43 74 48 - E-mail : contact@emitech.fr - URL : www.emitech.fr                   ACCREDITATIONS N°
                                                                                                                                                                1-0107, 1-0826,
  S.A. au capital de 1 560 000 € - R.C.S. VERSAILLES 344 545 645 - APE 7112B                                                                                    1-0827,1-1925,
                                                                                                                                                                1-2069,1-2070,
                                                                                                                                                               1-2376 & 1-6086
                                                                                                                                                                  LISTE DES SITES ACCREDITES ET
                                                                                                                                                                                       PORTEES
                                                                                                                                                              DISPONIBLES SUR WWW.COFRAC.FR


                                                                  RR051-17-103200-3-A Ed. 0




DESIGNATION OF PRODUCT:     Micro Tracker 2


Serial number (S/N):        20635F01010001F1


Reference / model (P/N):    ABWH-AZ190-00235


Software version:           2017-05-05-1431_sak-HW2.0-EU868_bootloader-file-BLEonly
                            Asset Tracker v1.x (for production)


MANUFACTURER:               ABEEWAY



COMPANY SUBMITTING THE PRODUCT:

Company:                    ABEEWAY

Address:                    635, ROUTE DES LUCIOLES
                            06560 VALBONNE
                            FRANCE

Responsible:                Mrs DENIS


DATES OF TEST:              From 17-Oct-17 to 20-Oct-17



TESTING LOCATION:           EMITECH ANGERS laboratory at JUIGNE SUR LOIRE (49) FRANCE
                            FCC Accredited under US-EU MRA Designation Number: FR0009
                            Test Firm Registration Number: 873677


TESTED BY:                  S. LOUIS                      VISA:




WRITTEN BY:                 S. LOUIS




                                       Page 2/29


                                                                                                                            RR051-17-103200-3-A Ed. 0




                                                                     CONTENTS


                        TITLE                                                                                                                                PAGE

1.      INTRODUCTION ....................................................................................................................................... 4
2.      PRODUCT DESCRIPTION ....................................................................................................................... 4
3.      NORMATIVE REFERENCE ...................................................................................................................... 5
4.      TEST METHODOLOGY ............................................................................................................................ 5
5.      TEST EQUIPMENT CALIBRATION DATES ............................................................................................ 6
6.      TESTS RESULTS SUMMARY .................................................................................................................. 7
7.      MEASUREMENT UNCERTAINTY ............................................................................................................ 8
8.      ADDITIONAL PROVISIONS TO THE GENERAL RADIATED EMISSION LIMITATIONS ....................... 9
9.      MAXIMUM PEAK CONDUCTED OUTPUT POWER ...............................................................................11
10.     INTENTIONAL RADIATOR .....................................................................................................................13
11.     MAXIMUM PEAK CONDUCTED POWER DENSITY ..............................................................................17
APPENDIX 1: TEST EQUIPMENT LIST ........................................................................................................................... 20
APPENDIX 2: 6 DB BANDWIDTH .................................................................................................................................... 22
APPENDIX 3: 99% BANDWIDTH ..................................................................................................................................... 25
APPENDIX 4: BAND EDGE .............................................................................................................................................. 28




                                                                            Page 3/29


                                                                                     RR051-17-103200-3-A Ed. 0




1.       INTRODUCTION

This report presents the results of radio test carried out on the following radio equipment: Micro Tracker 2, in
accordance with normative reference.

The product integrates:
    BLE radio transceiver
    a multifrequencies wireless transceiver LoRa
    WiFi radio transceiver
    GPS receiver.

This radio test report concern only the results for certification procedure on the BLE part, for test under subpart
B see radio test report RR051-17-103200-7-A.
The transceivers (LoRa, BLE and WiFi) can’t emit simultaneously as declared by the manufacturer.
The applicant declares that radio functions are not operational during the charge of the battery.



2.       PRODUCT DESCRIPTION

Class:                          B

Utilization:                    Residential

Antenna type and gain:          integral antenna (unknown gain); (considered 0 dBi)

Operating frequency range:      From 2402 MHz to 2480 MHz

Number of channels:             40

Channel spacing:                2MHz

Modulation:                     Bluetooth Low Energy

Power source:                   3.7Vdc Lithium Battery

Power level, frequency range and channels characteristics are not user adjustable.
The details pictures of the product and the circuit boards are joined with this file.




                                                    Page 4/29


                                                                              RR051-17-103200-3-A Ed. 0




3.    NORMATIVE REFERENCE

The standards and testing methods related throughout this report are those listed below.
They are applied on the whole test report even though the extensions (version, date and amendment) are not
repeated.

CFR 47 FCC Part 15 (2018)      Radio Frequency Devices

ANSI C63.10                    2013
                               Procedures for ComplianceTesting of Unlicensed Wireless Devices.

558074 D01 DTS v05             Guidance for compliance measurements on digital transmission system,
                               frequency hopping spread spectrum system, and hybrid system devices
                               operating under section 15.247 of the FCC rules.

447498 D01 General RF          RF Exposure procedures and equipment authorization policies for mobile and
Exposure Guidance v06          portable equipment



4.    TEST METHODOLOGY

Radio performance tests procedures given in CFR 47 part 15:

Subpart C – Intentional Radiators
                Paragraph 203: Antenna requirement
                Paragraph 205: Restricted bands of operation
                Paragraph 207: Conducted limits
                Paragraph 209: Radiated emission limits; general requirements
                Paragraph 212: Modular transmitter
                Paragraph 215: Additional provisions to the general radiated emission limitations
                Paragraph 247: Operation within the bands 902-928 MHZ, 2400-2483.5 MHz and 5725-5850
                                  MHz




                                                Page 5/29


                                                                         RR051-17-103200-3-A Ed. 0




5.     TEST EQUIPMENT CALIBRATION DATES

                                                                                Calibration    Next
                                                                   Last
Equipment              Model                    Type                             interval   calibration
                                                                calibration
                                                                                  (years)       due
     0000         BAT-EMC V3.6.0.32           Software               /               /           /
     1406              EMCO 6502            Loop antenna        13/04/2017           2      13/04/2019
     4087        Filtek LP03/1000-7GH      Low Pass Filter      11/04/2016           2      11/04/2018
     4088              R&S FSP40          Spectrum Analyzer     02/11/2015           2      02/11/2017
     5625    BL Microwave BP2442-84-7CS    Band pass filter     29/03/2016           2      29/03/2018
     7124       A.H. Systems SAS-572           Antenna          21/03/2015           3      21/03/2018
     7190              R&S HL223               Antenna          15/03/2016           3      15/03/2019
     7240              Emco 3110          Biconical antenna     15/03/2016           3      15/03/2019
     7299       Microtronics BRM50702      Reject band filter   06/11/2015           2      06/11/2017
     7566             Testo 608-Hi          Meteo station       15/02/2016           2      15/02/2018
     8535              EMCO 3115               Antenna          10/02/2016           4      10/02/2020
                       LUCIX Corp
     8704                                 Low-noise amplifier   02/05/2017          1       02/05/2018
                  S180265L3201 LNA
                                               Satellite
     8896         ACQUISYS GPS8              synchronized            /              /            /
                                          frequency standard
      8974   STORM MICROWAE k-20cm              cable           13/11/2015          2       13/11/2017
     10730     Mini-circuit ZFL-1000LN    Low-noise amplifier   05/04/2017          1       05/04/2018
     10739   LUCIX Corp S005180M3201      Low-noise amplifier   29/03/2017          1       29/03/2018
     10759           SIDT Cage 3           Anechoic chamber          /              /            /
     10771           EMCO 3117                 Antenna          23/11/2016          3       23/11/2019
     12917       SUCOFLEX K-2m                  cable           28/04/2016          2       28/04/2018
     14303       SUCOFLEX N-2m                  cable           28/11/2016          2       28/11/2018
     14304      SUCOFLEX N-2.5m                 cable           28/11/2016          2       28/11/2018
     14305       SUCOFLEX N-4m                  cable           28/11/2016          2       28/11/2018
     14476             Fluke 177              Multimeter        20/03/2017          1       20/03/2018
        -         GPIB SHOT V2.4               Software              /              /            /




                                          Page 6/29


                                                                                 RR051-17-103200-3-A Ed. 0




6.     TESTS RESULTS SUMMARY


        Test                       Description of test                    Respected criteria?            Comment
     procedure                                                          Yes No NAp NAs

FCC Part 15.203 ANTENNA REQUIREMENT                                      X                           Note 1

FCC Part 15.205 RESTRICTED BANDS OF OPERATION                            X

FCC Part 15.207 CONDUCTED LIMITS                                                       X             Note 2

FCC Part 15.209 RADIATED EMISSION LIMITS; general                        X                           Note 3
                requirements

FCC part 15.215 ADDITIONAL PROVISIONS TO THE GENERAL
                RADIATED EMISSION LIMITATIONS
                (a) Alternative to general radiated emission limits      X
                (b) Unwanted emissions outside of §15.247                X                           Note 4
                frequency bands
                (c) 20 dB bandwidth and band-edge compliance             X

FCC Part 15.247 OPERATION WITHIN THE BANDS 902-928 MHZ,
                2400-2483.5 MHz and 5725-5850 MHz
                (a) (1) Hopping systems                                                X
                (a) (2) Digital modulation techniques                    X                           Note 5
                (b) Maximum peak output power                            X                           Note 6
                (c) Operation with directional antenna gains > 6 dBi                   X
                (d) Intentional radiator                                 X
                (e) Peak power spectral density                          X
                (f) Hybrid system                                                      X
                (g) Frequency hopping requirements                                     X
                (h) Frequency hopping intelligence                                     X
                (i) RF exposure compliance                               X

NAp: Not Applicable             NAs: Not Asked

Note 1: Integral antenna without standard connector.

Note 2: Supplied by batteries. The radio part of the equipment is no operational during charging mode.

Note 3: See FCC part 15.247 (d).

Note 4: See FCC part 15.209. Unwanted emissions levels are all below the fundamental emission field
        strength level.

Note 5: The minimum 6 dB bandwidth of the equipment is 629 kHz (see appendix 2).

Note 6: Conducted measurement is not possible (integral antenna), so we used the radiated method in open
        field.

                                                  Page 7/29


                                                                                      RR051-17-103200-3-A Ed. 0




7.    MEASUREMENT UNCERTAINTY

To declare, or not, the compliance with the specifications, it was not explicitly taken into account of uncertainty
associated with the result(s)

The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement
multiplied by the coverage factor k=2, which for normal distribution corresponds to a coverage probability of
approximately 95%.

                                                                          Emitech
                                      Parameter
                                                                         Uncertainty
                       RF power, conducted                                 0.75dB
                       Radiated emission valid to 26 GHz
                                                F < 62.5 MHz:              5.14 dB
                                      62.5 MHz < F < 1 GHz:                5.13 dB
                                       1 GHz < F < 26 GHz:                 5.16 dB
                       AC Power Lines conducted emissions                  3.38 dB
                       Temperature                                           1 °C
                       Humidity                                             5%




                                                    Page 8/29


                                                                               RR051-17-103200-3-A Ed. 0




8.    ADDITIONAL PROVISIONS TO THE GENERAL RADIATED EMISSION LIMITATIONS

Temperature (°C) : 24.2             Humidity (%HR): 54                   Date : October 18, 2017
Technician : S. LOUIS

Standard: FCC Part 15

Test procedure: Paragraph 15.215

Test set up:

Test realized in near field. All field strength measurements are correlated with the radiated maximum peak
output power

Test operating condition of the equipment:

The equipment under test is blocked in continuous modulated transmission mode, at the highest output power
level at which the transmitter is intended to operate.


We used for power source the internal battery of the equipment and we noted:
Voltage at the beginning of test (Vdc):          4.27
Voltage at the end of test (Vdc):                4.12
Percentage of voltage drop during the test (%): 3.51




                                                 Page 9/29


                                                                                  RR051-17-103200-3-A Ed. 0




  Results:

  Lower Band Edge: From 2400 MHz to 2402 MHz
  Upper Band Edge: From 2483.5 MHz to 2485.5 MHz


  Sample N° 1

Fundamental     Field Strength    Detector     Frequency  Delta          Calculated     Limit        Margin
frequency       Level of          (Peak or     of maximum Marker         Max Out-of-    (dBµV/m)     (dB)
(MHz)           fundamental       Average)     Band-edges (dB) (1)       Band
                (dBµV/m)                       Emission                  Emission
                                               (MHz)                     Level
                                                                         (dBµV/m)
    2402              86.8            Peak        2399.92       -40.99       -45.81         66.8      20.99
    2480              80.9            Peak        2485.45       -32.80     -48.10 (2)        74       25.90
     (1) Marker-Delta method
     (2) The peak level is lower than the average limit (54 dBµV/m)

  Band-edge curves are given in appendix 4.


  Test conclusion:

  RESPECTED STANDARD




                                                  Page 10/29


                                                                                     RR051-17-103200-3-A Ed. 0




9.      MAXIMUM PEAK CONDUCTED OUTPUT POWER

Temperature (°C) : 23.8               Humidity (%HR): 53                     Date : October 18, 2017
Technician : S. LOUIS

Standard: FCC Part 15

Test procedure: paragraph 15.247 (b)

RBW≥DTS bandwidth method of paragraph 11.9.1.1 of ANSI C63.10

Test set up:

First an exploratory radiated measurement was performed.

During this phase the product is oriented in three orthogonal planes.

Then the final measurement is realized with the product on the most critical orientation.

The system is tested in anechoic chamber, the EUT is placed on a rotating table, 1.50 m from a ground plane.

Zero degree azimuths correspond to the front of the device under test.

See photos in appendix 2.

Distance of antenna: 3 meters (in anechoic room)

Antenna height: 1.50 meter (in anechoic room)

Antenna polarization: vertical and horizontal (only the highest level is recorded)

The measurement of the radiated electro-magnetic field is realized with an analyser and peak detector. The
resolution bandwidth is adjusted at 10 MHz and video bandwidth at 10 MHz. (9.1.1 of KDB 558074)

Finally the radiated electro-magnetic field is converted in dBm with the following formula:
EIRP(dBm) = E (dBμV/m) + 20log(D) - 104.8; where D is the measurement distance in meters and antenna
Gain = 0 dBi.

Equipment under test operating condition:

The equipment under test is blocked in continuous modulated transmission mode, at the highest output power
level at which the transmitter is intended to operate.


We used for power source the internal battery of the equipment and we noted:
Voltage at the beginning of test (Vdc):          4.28
Voltage at the end of test (Vdc):                4.16
Percentage of voltage drop during the test (%): 2.80




                                                   Page 11/29


                                                                            RR051-17-103200-3-A Ed. 0




Results:


Sample N° 1 : Low Channel (F = 2402 MHz)

                                Electro-        Maximum Peak conducted       Limit
                              magnetic field        output power (1)
                               (dBµV/m):          (dBm)          (W)          (W)
                     Nominal
                      supply          87.5             -7.75     0.00017       1
                     voltage:
Polarization of test antenna: Vertical (height: 150 cm)
Position of equipment: Upright position (azimuth: 205 degrees)


Sample N° 1 : Central Channel (F = 2426 MHz)

                                Electro-        Maximum Peak conducted       Limit
                              magnetic field        output power (1)
                               (dBµV/m):          (dBm)          (W)          (W)
                     Nominal
                      supply          86.5             -8.75     0.00013       1
                     voltage:
Polarization of test antenna: Vertical (height: 150 cm)
Position of equipment: Upright position (azimuth: 225 degrees)


Sample N° 1 : High Channel (F = 2480 MHz)

                                Electro-        Maximum Peak conducted       Limit
                              magnetic field        output power (1)
                               (dBµV/m):          (dBm)          (W)          (W)
                     Nominal
                      supply           82             -13.25     0.00005       1
                     voltage:
Polarization of test antenna: Vertical (height: 150 cm)
Position of equipment: Upright position (azimuth: 180 degrees)


   (1) Maximum Peak conducted output power:
EIRP(dBm) = E (dBμV/m) + 20log(D) - 104.8; where D is the measurement distance in meters and antenna
Gain = 0 dBi.


Test conclusion:

RESPECTED STANDARD




                                                 Page 12/29


                                                                                     RR051-17-103200-3-A Ed. 0




10.   INTENTIONAL RADIATOR

Temperature (°C) : 24.2               Humidity (%HR): 54                     Date : October 18, 2017
Technician : S. LOUIS

Standard: FCC Part 15

Test procedure: paragraph 15.205, paragraph 15.209, paragraph 15.247 (d)

Emissions in non-restricted frequency bands method of paragraph 11.11 of ANSI C63.10
Emissions in restricted frequency bands method of paragraph 11.12 of ANSI C63.10

Test set up:

First an exploratory radiated measurement was performed.

During this phase the product is oriented in three orthogonal planes.

Then the final measurement is realized with the product on the most critical orientation.

The measure is realized on open area test site under 1 GHz and in anechoic chamber above 1 GHz.

When the system is tested in an open area test site (OATS), the EUT is placed on a rotating table, 0.8m from
a ground plane.

When the system is tested in anechoic chamber, the EUT is placed on a rotating table, 1.50 m from a ground
plane.

Zero degree azimuths correspond to the front of the device under test.

See photos in appendix 2.

Frequency range: From 9 kHz to 25GHz - 10th harmonic of the highest fundamental frequency (2480MHz).

Detection mode: Quasi-peak (F < 1 GHz)                      Peak / Average (F > 1 GHz)

Bandwidth:     200Hz (9 kHz < F < 150kHz)
               9 kHz (150 kHz < F < 30MHz)
               120 kHz (30 MHz < F < 1 GHz)
               100 kHz / 1 MHz (F > 1 GHz)

Distance of antenna: 3 meters (in anechoic room)

Antenna height: 1.50 meter (in anechoic room)

Antenna polarization: vertical and horizontal (only the highest level is recorded)




                                                   Page 13/29


                                                                               RR051-17-103200-3-A Ed. 0




Equipment under test operating condition:

The equipment under test is blocked in continuous modulated transmission mode, at the highest output power
level at which the transmitter is intended to operate.

We used for power source the internal battery of the equipment and we noted:
Voltage at the beginning of test (Vdc):          4.28
Voltage at the end of test (Vdc):                4.16
Percentage of voltage drop during the test (%): 2.80




                                                Page 14/29


                                                                                  RR051-17-103200-3-A Ed. 0




Results:


Sample N° 1 : Low Channel (F = 2402 MHz)

 Frequencies Detector Position Antenna RBW            Polarization       Field          Limits     Margin
    (MHz)       P               height (kHz)          H: Horizontal    strength       (dBV/m)      (dB)
               QP                (cm)                 V: Vertical     Measured            or
               Av                                                       at 3 m          (dBm)
                                                                      (dBV/m)
   4804 (1)       P         2         150      1000          H           54.5            74         19.5
   4804 (1)       Av        2         150      1000          H            50             54          4
    7206          P         2         150      100           H           50.9           66.8        15.9
   P= Peak, QP=Quasi-peak, Av=Average
   (1) Restricted bands of operation in 15.205


Sample N° 1 : Central Channel (F = 2426 MHz)

 Frequencies Detector Position Antenna RBW            Polarization       Field          Limits     Margin
    (MHz)       P               height (kHz)          H: Horizontal    strength       (dBV/m)      (dB)
               QP                (cm)                 V: Vertical     Measured            or
               Av                                                       at 3 m          (dBm)
                                                                      (dBV/m)
   4852 (1)       P         2         150      1000          H           53.3            74         20.7
   4852 (1)       Av        2         150      1000          H           51.8            54          2.2
   7278 (1)       P         2         150      1000          H           56.3            74         17.7
   7278 (1)       Av        2         150      1000          H           50.5            54          3.5
   P= Peak, QP=Quasi-peak, Av=Average
   (1) Restricted bands of operation in 15.205


Sample N° 1 : High Channel (F = 2480 MHz)

 Frequencies Detector Position Antenna RBW            Polarization       Field          Limits     Margin
    (MHz)       P               height (kHz)          H: Horizontal    strength       (dBV/m)      (dB)
               QP                (cm)                 V: Vertical     Measured            or
               Av                                                       at 3 m          (dBm)
                                                                      (dBV/m)
   4960 (1)       P         2         150      1000          H           55.6            74         18.4
   4960 (1)       Av        2         150      1000          H            52             54           2
   7440 (1)       P         2         150      1000          H           55.7            74         18.3
   7440 (1)       Av        2         150      1000          H           50.1            54          3.9
   P= Peak, QP=Quasi-peak, Av=Average
   (1) Restricted bands of operation in 15.205




                                                Page 15/29


                                                                                RR051-17-103200-3-A Ed. 0




Applicable limits: In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or
                   digitally modulated intentional radiator is operating, the radio frequency power that is
                   produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz
                   bandwidth within the band that contains the highest level of the desired power.
                   The highest level recorded in a 100 kHz bandwidth is 86.8 dBµV/m on Low channel.
                   So the applicable limit is 66.8 dBµV/m.
                   In addition, radiated emissions which fall in the restricted band, as defined in section
                   15.205 (a), must also comply with the radiated emission limits specified in section 15.209
                   (a) (see section 15.205 (c)).


Test conclusion:

RESPECTED STANDARD




                                                 Page 16/29


                                                                                     RR051-17-103200-3-A Ed. 0




11.   MAXIMUM PEAK CONDUCTED POWER DENSITY

Temperature (°C) : 23.8               Humidity (%HR): 53                     Date : October 18, 2017
Technician : S. LOUIS

Standard: FCC Part 15

Test procedure: paragraph 15.247 (e)

PKPSD (Peak PSD) method of paragraph 11.10.2 of ANSI C63.10

Test set up:

First an exploratory radiated measurement was performed.

During this phase the product is oriented in three orthogonal planes.

Then the final measurement is realized with the product on the most critical orientation.

The system is tested in an open area test site (OATS), the EUT is placed on a rotating table, 0.8m from a
ground plane.

The system is tested in anechoic chamber, the EUT is placed on a rotating table, 1.50 m from a ground plane.

Zero degree azimuths correspond to the front of the device under test.

See photos in appendix 2.

Distance of antenna: 3 meters (in anechoic room)

Antenna height: 1.50 meter (in anechoic room)

Antenna polarization: vertical and horizontal (only the highest level is recorded)

The measurement of the radiated electro-magnetic field is realized with an analyser.

Span:                                         1MHz
Resolution bandwidth:                         3kHz
Video bandwidth:                              10kHz
Detector:                                     Peak
Sweep time:                                   Autocouple
Trace mode:                                   MaxHold

Then the peak marker function is used.

Finally the radiated electro-magnetic field is converted in dBm with the following formula:
EIRP(dBm) = E (dBμV/m) + 20log(D) - 104.8; where D is the measurement distance in meters and antenna
Gain = 0 dBi.




                                                   Page 17/29


                                                                               RR051-17-103200-3-A Ed. 0




Equipment under test operating condition:

The equipment under test is blocked in continuous modulated transmission mode, at the highest output power
level at which the transmitter is intended to operate.


We used for power source the internal battery of the equipment and we noted:
Voltage at the beginning of test (Vdc):          4.28
Voltage at the end of test (Vdc):                4.16
Percentage of voltage drop during the test (%): 2.80




                                                Page 18/29


                                                                              RR051-17-103200-3-A Ed. 0




Results:


Sample N° 1 : Low Channel (F = 2402 MHz)

                              Electro-        Maximum Peak conducted    Limit
                            magnetic field        power density(1)
                             (dBµV/m):             (dBm / 3 kHz)     (dBm / 3 kHz)
                   Nominal
                    supply          74.4                  -20.85                8
                   voltage:
Polarization of test antenna: Vertical (height: 150 cm)
Position of equipment: Upright position (azimuth: 205 degrees)


Sample N° 1 : Central Channel (F = 2426 MHz)

                              Electro-        Maximum Peak conducted    Limit
                            magnetic field        power density(1)
                             (dBµV/m):             (dBm / 3 kHz)     (dBm / 3 kHz)
                   Nominal
                    supply          74.3                  -20.95                8
                   voltage:
Polarization of test antenna: Vertical (height: 150 cm)
Position of equipment: Upright position (azimuth: 225 degrees)


Sample N° 1 : High Channel (F = 2480 MHz)

                              Electro-        Maximum Peak conducted    Limit
                            magnetic field        power density(1)
                             (dBµV/m):             (dBm / 3 kHz)     (dBm / 3 kHz)
                   Nominal
                    supply          68.7                  -26.55                8
                   voltage:
Polarization of test antenna: Vertical (height: 150 cm)
Position of equipment: Upright position (azimuth: 225 degrees)


Maximum Peak conducted power density:
EIRP(dBm / 3 kHz) = E (dBμV/m / 3 kHz) + 20log(D) - 104.8; where D is the measurement distance in meters
and antenna Gain = 0 dBi.


Test conclusion:

RESPECTED STANDARD

                        End of report, 4 appendixes to be forwarded 


                                                 Page 19/29


                                                                          RR051-17-103200-3-A Ed. 0




                               APPENDIX 1: Test equipment list

                Additional provisions to the general radiated emission limitations

                    TYPE                         MANUFACTURER                 EMITECH NUMBER
Full anechoic chamber                       EMITECH                                10759
Satellite synchronized frequency standard   ACQUISYS                                8896
GPS8
Spectrum Analyzer FSP40                     Rohde & Schwarz                           4088
Antenna 3117                                ETS-Lindgren                             10771
Low-noise amplifier S005180M3201            LUCIX Corp.                              10739
Cable N-2m                                  SUCOFLEX                                 14303
Cable N-2.5m                                SUCOFLEX                                 14304
Cable N-4m                                  SUCOFLEX                                 14305
Multimeter 177                              Fluke                                    14476
Meteo station 608-H1                        Testo                                     7566
Software                                    GPIBShot V2.4                               -


                        Maximum Peak Conducted (Average) Output Power

                    TYPE                         MANUFACTURER                 EMITECH NUMBER
Full anechoic chamber                       EMITECH                                10759
Satellite synchronized frequency standard   ACQUISYS                                8896
GPS8
Spectrum Analyzer FSP40                     Rohde & Schwarz                           4088
Band pass filter BP2442-84-7CS              BL Microwave                              5625
Antenna 3115                                EMCO                                      8535
Low-noise amplifier S005180M3201            LUCIX Corp.                              10739
Cable N-2m                                  SUCOFLEX                                 14303
Cable N-2.5m                                SUCOFLEX                                 14304
Cable N-4m                                  SUCOFLEX                                 14305
Multimeter 177                              Fluke                                    14476
Meteo station 608-H1                        Testo                                     7566
Software                                    BAT-EMC V3.6.0.32                         0000




                                            Page 20/29


                                                                  RR051-17-103200-3-A Ed. 0




                                        Intentional Radiator

                    TYPE                         MANUFACTURER        EMITECH NUMBER
Full anechoic chamber                       EMITECH                       10759
Satellite synchronized frequency standard   ACQUISYS                       8896
GPS8
Spectrum Analyzer FSP40                     Rohde & Schwarz                  4088
Loop antenna 6502                           EMCO                             1406
Biconical antenna 3110                      Emco                             7240
Log periodic antenna HL223                  Rohde & Schwarz                  7190
Antenna 3117                                ETS-Lindgren                    10771
Antenna SAS-572                             AH Systems                       7124
Low-noise amplifier ZFL-1000LN              Mini-circuit                    10730
Low-noise amplifier S005180M3201            LUCIX Corp.                     10739
Low-noise amplifier S180265L3201 LNA        LUCIX Corp.                      8704
Low pass filter LP03/1000-7GH               Filtek                           4087
Reject band filter BRM50702                 Microtronics                     7299
Cable N-2m                                  SUCOFLEX                        14303
Cable N-2.5m                                SUCOFLEX                        14304
Cable N-4m                                  SUCOFLEX                        14305
Cable k-20cm                                STORM MICROWAE                   8974
Cable K-2m                                  SUCOFLEX                        12917
Multimeter 177                              Fluke                           14476
Meteo station 608-H1                        Testo                            7566
Software                                    BAT-EMC V3.6.0.32                0000


                                Maximum Conducted Power Density

                    TYPE                         MANUFACTURER        EMITECH NUMBER
Full anechoic chamber                       EMITECH                       10759
Satellite synchronized frequency standard   ACQUISYS                       8896
GPS8
Spectrum Analyzer FSP40                     Rohde & Schwarz                  4088
Band pass filter BP2442-84-7CS              BL Microwave                     5625
Antenna 3115                                EMCO                             8535
Low-noise amplifier S005180M3201            LUCIX Corp.                     10739
Cable N-2m                                  SUCOFLEX                        14303
Cable N-2.5m                                SUCOFLEX                        14304
Cable N-4m                                  SUCOFLEX                        14305
Multimeter 177                              Fluke                           14476
Meteo station 608-H1                        Testo                            7566
Software                                    BAT-EMC V3.6.0.32                0000




                                            Page 21/29


                                                                              RR051-17-103200-3-A Ed. 0




                           APPENDIX 2: 6 dB bandwidth

                                           Low Channel

                                                     * RBW   100 kHz   Marker 1 [T1 ]
                                                      VBW 300 kHz                  71.88 dBµV
       Ref   97 dBµV          * Att    0 dB           SWT 40 ms             2.401986250 GHz

                                                                       ndB [T1]      6.00 dB
                                                                       BW 630.625000000 kHz
       90
                                                                       Temp 1 [T1 ndB]           A

                                                                                   65.79 dBµV
1 PK
       80                                                                   2.401656250 GHz
MAXH
                                                                       Temp 2 [T1 ndB]
                                                 1
                                                                                   65.80 dBµV
       70
                                      T1                      T2            2.402286875 GHz



       60



       50
                                                                                                 EXT


       40                                                                                        3DB




       30



       20



       10



       0

       Center 2.402 GHz                       250 kHz/                            Span 2.5 MHz




Date: 18.OCT.2017         17:02:03




                                           Page 22/29


                                                                               RR051-17-103200-3-A Ed. 0




                                           Central Channel

                                                      * RBW   100 kHz   Marker 1 [T1 ]
                                                       VBW 300 kHz                  76.24 dBµV
       Ref   97 dBµV          * Att    0 dB            SWT 40 ms             2.425984063 GHz

                                                                        ndB [T1]      6.00 dB
                                                                        BW 632.187500000 kHz
       90
                                                                        Temp 1 [T1 ndB]           A

                                                                                    70.61 dBµV
1 PK
       80                                         1                          2.425658750 GHz
MAXH
                                                                        Temp 2 [T1 ndB]
                                      T1                       T2                   70.16 dBµV
       70
                                                                             2.426290938 GHz



       60



       50
                                                                                                  EXT


       40                                                                                         3DB




       30



       20



       10



       0

       Center 2.426 GHz                        250 kHz/                            Span 2.5 MHz




Date: 18.OCT.2017         17:03:25




                                             Page 23/29


                                                                                  RR051-17-103200-3-A Ed. 0




                                           High Channel

                                                     * RBW       100 kHz   Marker 1 [T1 ]
                                                       VBW 300 kHz                     69.69 dBµV
       Ref   97 dBµV         * Att        0 dB         SWT 40 ms                2.480193750 GHz

                                                                           ndB [T1]      6.00 dB
                                                                           BW 629.062500000 kHz
       90
                                                                           Temp 1 [T1 ndB]           A

                                                                                       63.33 dBµV
1 PK
       80                                                                       2.479648750 GHz
MAXH
                                                                           Temp 2 [T1 ndB]
                                                             1                         63.85 dBµV
       70
                                                                                2.480277812 GHz
                                     T1                           T2


       60



       50
                                                                                                     EXT


       40                                                                                            3DB




       30



       20



       10



       0

       Center 2.48 GHz                           250 kHz/                             Span 2.5 MHz




Date: 18.OCT.2017        17:04:33




                                            Page 24/29


                                                                               RR051-17-103200-3-A Ed. 0




                            APPENDIX 3: 99% bandwidth

                                         Low Channel

                                                      * RBW   30 kHz   Marker 1 [T1 ]
                                                       VBW 100 kHz                70.81 dBµV
       Ref   97 dBµV            * Att   0 dB           SWT 40 ms             2.401995325 GHz

                                                                       OBW   1.005125000 MHz
                                                                       Temp 1 [T1 OBW]
       90
                                                                                  53.14 dBµV   A

                                                                             2.401480250 GHz
1 PK
       80                                                              Temp 2 [T1 OBW]
MAXH
                                                                                  52.54 dBµV
                                                  1
                                                                             2.402485375 GHz
       70



       60
                           T1                                          T2

       50
                                                                                               EXT


       40                                                                                      3DB




       30



       20



       10



       0

       Center 2.402 GHz                        220 kHz/                         Span 2.2 MHz




Date: 18.OCT.2017         17:08:45




                                          Page 25/29


                                                                               RR051-17-103200-3-A Ed. 0




                                        Central Channel

                                                      * RBW   30 kHz   Marker 1 [T1 ]
                                                       VBW 100 kHz                75.59 dBµV
       Ref   97 dBµV            * Att   0 dB           SWT 40 ms             2.425998900 GHz

                                                                       OBW   1.019425000 MHz
                                                                       Temp 1 [T1 OBW]
       90
                                                                                  56.27 dBµV   A

                                                                             2.425472000 GHz
1 PK
       80                                                              Temp 2 [T1 OBW]
MAXH                                              1
                                                                                  58.24 dBµV
                                                                             2.426491425 GHz
       70



                                                                       T2
       60                  T1



       50
                                                                                               EXT


       40                                                                                      3DB




       30



       20



       10



       0

       Center 2.426 GHz                        220 kHz/                         Span 2.2 MHz




Date: 18.OCT.2017         17:09:59




                                          Page 26/29


                                                                              RR051-17-103200-3-A Ed. 0




                                        High Channel

                                                     * RBW   30 kHz   Marker 1 [T1 ]
                                                      VBW 100 kHz                68.81 dBµV
       Ref   97 dBµV           * Att   0 dB           SWT 40 ms             2.479997525 GHz

                                                                      OBW   1.013925000 MHz
                                                                      Temp 1 [T1 OBW]
       90
                                                                                 51.65 dBµV   A

                                                                            2.479467050 GHz
1 PK
       80                                                             Temp 2 [T1 OBW]
MAXH
                                                                                 50.65 dBµV

                                                 1                          2.480480975 GHz
       70



       60

                          T1
                                                                      T2
       50
                                                                                              EXT


       40                                                                                     3DB




       30



       20



       10



       0

       Center 2.48 GHz                        220 kHz/                         Span 2.2 MHz




Date: 18.OCT.2017        17:07:21




                                         Page 27/29


                                                                         RR051-17-103200-3-A Ed. 0




                             APPENDIX 4: Band edge

                                      Low Channel

                                                * RBW   100 kHz   Delta 1 [T1 ]
                                                  VBW 300 kHz               -40.99 dB
       Ref   97 dBµV         * Att   0 dB         SWT 40 ms           -2.077500000 MHz

                                                                  Marker 1 [T1 ]
                                                                            72.28 dBµV
       90
                                                                       2.401996000 GHz   A


1 PK
       80
MAXH
                                                              1

       70



       60



       50
                                                                                         EXT


       40                                                                                3DB


                              1

       30



       20



       10


                               F1
       0

       Start 2.398 GHz                      600 kHz/                    Stop 2.404 GHz




Date: 18.OCT.2017        17:12:27




                                       Page 28/29


                                                                      RR051-17-103200-3-A Ed. 0




                                     High Channel

                                               * RBW   1 MHz   Delta 2 [T1 ]
                                                 VBW 3 MHz               -32.80 dB
       Ref   97 dBµV        * Att   0 dB         SWT 40 ms          5.739375000 MHz

                                                               Marker 1 [T1 ]
                                                                         80.27 dBµV
       90
                                                                    2.479713750 GHz      A

                       1
1 PK
       80
MAXH



       70



       60



       50                                                                            2
                                                                                         EXT


       40                                                                                3DB




       30



       20



       10


                                                               F1
       0

       Center 2.48175 GHz                  750 kHz/                    Span 7.5 MHz




Date: 18.OCT.2017      17:28:48




                                      Page 29/29



Document Created: 2019-01-29 10:31:52
Document Modified: 2019-01-29 10:31:52

© 2019 FCC.report