RF exposure

FCC ID: 2AORE-WASP-X

RF Exposure Info

Download: PDF
FCCID_4065742

                                                                                               REPORT No.:SZ18090105S01




                               FCC RF EXPOSURE
                         EVALUATION REPORT
          APPLICANT                           : Shanghai Flydigi Electronics Technology Co.,Ltd.

          PRODUCT NAME                        : Flydigi Wasp One-handed Gamepad

          MODEL NAME                          : FeiZhi Wasp-X

          BRAND NAME                          : Flydigi

          FCC ID                              : 2AORE-WASP-X
          STANDARD(S)                         : 47CFR 2.1093
                                                KDB 447498
          ISSUE DATE                          : 2018-09-27




                                                                      Reviewed by:
                                                                                               Gan yueming (Reviewer)



                                                                      Approved by:
                                                                                               Peng Huarui (Supervisor)




NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.


 MORLAB
                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn


                                                                                          REPORT No.:SZ18090105S01


                                                        DIRECTORY
1. Technical Information········································································································ 3
1.1    Applicant and Manufacturer Information····································································· 3
1.2    Equipment Under Test (EUT) Description ··································································· 3
1.3    Photographs of the EUT································································································· 4
1.4    Identification of all used EUT ························································································ 5
1.5    Applied Reference Documents ····················································································· 5
2. Device Category and RF Exposure Limit ······································································· 6
3. Measurement of RF Output Power ·················································································· 7
4. RF Exposure Evaluation ··································································································· 8
Annex A General Information ································································································· 9




                                                              Change History
            Issue                                  Date                                     Reason for change
             1.0                             2018-09-27                                             First edition




MORLAB
                    SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                    FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                    Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                             Page2 0f 9


                                                                                      REPORT No.:SZ18090105S01

1. Technical Information
Note: Provide by manufacturer.

1.1 Applicant and Manufacturer Information

Applicant:                             Shanghai Flydigi Electronics Technology Co.,Ltd.
Applicant Address:                     Rm1108, No.258 Guoxia Rd, Yangpu District,Shanghai
Manufacturer:                          Shanghai Flydigi Electronics Technology Co.,Ltd.
Manufacturer Address:                  Rm1108, No.258 Guoxia Rd, Yangpu District,Shanghai


1.2 Equipment Under Test (EUT) Description

 EUT Type:                      Flydigi WASP-X Single-Handed Controller
 Hardware Version:              FeiZhi Wasp-V1.1
 Software Version:              FeiZhi Wasp-V1.0.1
 Frequency Bands:               Bluetooth: 2402MHz-2480MHz
 Modulation Mode:               BLE: GFSK
 Antenna Gain:                  -4.41dBi




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page3 0f 9


                                                                                      REPORT No.:SZ18090105S01

1.3 Photographs of the EUT
1.   EUT front view




2.   EUT rear view




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page4 0f 9


                                                                                         REPORT No.:SZ18090105S01

1.4 Identification of all used EUT
The EUT identity consists of numerical and letter characters, the letter character indicates the test
sample, and the following two numerical characters indicate the software version of the test
sample.


              EUT
                                     Hardware Version                                   Software Version
            Identity
              1#                      FeiZhi Wasp-V1.1                                  FeiZhi Wasp-V1.0.1



1.5 Applied Reference Documents
Leading reference documents for testing:
No.    Identity                                      Document Title
1      47 CFR§2.1093                                 Radio frequency Radiation Exposure Evaluation: portable
                                                     devices
2      KDB 447498 D01v06                             General RF Exposure Guidance




MORLAB
                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                    Tel: 86-755-36698555   Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                            Page5 0f 9


                                                                                      REPORT No.:SZ18090105S01

2. Device Category and RF Exposure Limit
Per user manual, this device is a Flydigi WASP-X Single-Handed Controller. Based on 47CFR
2.1093, this device belongs to portable device category with General Population/Uncontrolled
exposure.
Portable Devices:
47CFR 2.1093(b)
For purposes of this section, a portable device is defined as a transmitting device designed to be
used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the
user.

GENERAL POPULATION / UNCONTROLLED EXPOSURE
47CFR 2.1093(d) (2)
Limits for General Population/Uncontrolled exposure: 0.08 W/kg as averaged over the whole-body
and spatial peak SAR not exceeding 1.6 W/kg as averaged over any 1 gram of tissue (defined as a
tissue volume in the shape of a cube). Exceptions are the hands, wrists, feet and ankles where the
spatial peak SAR shall not exceed 4 W/kg, as averaged over any 10 grams of tissue (defined as a
tissue volume in the shape of a cube). General Population/Uncontrolled limits apply when the
general public may be exposed, or when persons that are exposed as a consequence of their
employment may not be fully aware of the potential for exposure or do not exercise control over
their exposure. Warning labels placed on consumer devices such as cellular telephones will not be
sufficient reason to allow these devices to be evaluated subject to limits for occupational/controlled
exposure in paragraph (d)(1) of this section.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page6 0f 9


                                                                                      REPORT No.:SZ18090105S01

3. Measurement of RF Output Power
   Bluetooth
                                                    Frequency                        Peak Power(dBm)
               Band             Channel
                                                        (MHz)                              GFSK
                                  CH 00                  2402                                1.29
               BLE                CH 19                  2440                                1.68
                                  CH 39                  2480                                2.70
                            Tune-up Limit                                                      3
Note:
According to KDB 447498, time-averaged maximum conducted output power applies to SAR and,
as required by § 2.1091(c), time-averaged effective radiated power applies to MPE.




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                    Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page7 0f 9


                                                                                     REPORT No.:SZ18090105S01


4. RF Exposure Evaluation
The device only incorporates a Bluetooth transmitter, so standalone SAR evaluation is required for
Bluetooth and simultaneous SAR is not required.

Standalone transmission SAR evaluation:

According to KDB 447498 section 4.3.1, the 1-g SAR test exclusion thresholds at test separation
Distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)]·[√f(GHz)] ≤ 3.0
The maximum tune-up limit power is 2.0mW @ 2.48GHz
When Flydigi WASP-X Single-Handed Controller is used on the hand/head, so use 5mm as the
most conservative minimum test separation distance,
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)]·[√f(GHz)] =0.63 > 3.0

Therefore the standalone SAR evaluation are not required for this device.




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                        Page8 0f 9


                                                                                      REPORT No.:SZ18090105S01



Annex A General Information
1. Identification of the Responsible Testing Laboratory
  Company Name:                                      Shenzhen Morlab Communications Technology Co., Ltd.
  Department:                                        Morlab Laboratory
  Address:                                           FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                                     Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                                     Province, P. R. China
  Responsible Test Lab Manager:                      Mr. Su Feng
  Telephone:                                         +86 755 36698555
  Facsimile:                                         +86 755 36698525


2. Identification of the Responsible Testing Location
 Name:                                               Shenzhen Morlab Communications Technology Co., Ltd.
                                                     Morlab Laboratory
 Address:                                            FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                                     Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                                     Province, P. R. China




                                                        END OF REPORT




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page9 0f 9



Document Created: 2019-04-22 09:14:56
Document Modified: 2019-04-22 09:14:56

© 2024 FCC.report