FCC ID: 2AOR7-TABLO400

RF Exposure Info

Download: PDF
FCCID_4211052

SAR evaluation


MPE Calculation Method
                      0.5
E (V/m) = (30*P*G)          /d
Power Density: Pd (W/m2) = E2/377
E = Electric Field (V/m)
P = Peak RF output Power (W)
G = EUT Antenna numeric gain (numeric)
d = Separation distance between radiator and human body (m)
The formula can be changed to
Pd = (30*P*G) / (377*d2)
From the peak EUT RF output power, the minimum mobile separation distance,
d=0.2m, as well
as the gain of the used antenna, the RF power density can be obtained.


Calculated Result and Limit (WORSE CASE IS AS BELOW)
Wifi:
Directional   Peak Output           Power Density    Limit of Power   Test
AntennaGain   Power (mW)            (S)(mW/cm2)      Density (S)      Result
(Numeric)                                            (mW/cm2)


4(6dBi)       156.315               0.124            1                Compiles
              (21.94dBm@2437MHz)


UNII:
Directional   Peak Output           Power Density    Limit of Power   Test
AntennaGain   Power (mW)            (S)(mW/cm2)      Density (S)      Result
(Numeric)                                            (mW/cm2)


4(6dBi)       81.10                  0.065           1                Compiles
              (19.09dBm@5825MHz)



Document Created: 2019-03-22 19:17:41