03 FCC Test Report_FDS

FCC ID: 2AON3-RCS05

Test Report

Download: PDF
FCCID_4253915

                                                                                Test report No.         : 12104474H-R2
                                                                                Page                    : 1 of 29
                                                                                Issued date             : April 9, 2019
                                                                                FCC ID                  : 2AON3-RCS05




                             RADIO TEST REPORT
                                 Test Report No. : 12104474H-R2
         Applicant                             :     KEYCOM CORPORATION

         Type of Equipment                     :     Imaging Radar

         Model No.                             :     RCS05

         FCC ID                                :     2AON3-RCS05

         Test regulation                       :     FCC Part 95 Subpart M: 2017

         Test Result                           :     Complied (Refer to SECTION 3.2)
           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with the above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report covers Radio technical requirements. It does not cover administrative issues
                such as Manual or non-Radio test related Requirements. (if applicable)
           6.   The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
           7.   This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
           8.   The information provided from the customer for this report is identified in SECTION 1.
           9.   This report is a revised version of 12104474H-R1. 12104474H-R1 is replaced with this report.

                          Date of test:                   October 2 to November 9, 2018

                          Representative test
                          engineer:
                                                                Ryota Yamanaka
                                                                   Engineer
                                                          Consumer Technology Division


                          Approved by:
                                                               Tsubasa Takayama
                                                                    Leader
                                                          Consumer Technology Division

                                                           This laboratory is accredited by the NVLAP LAB CODE
                                                           200572-0, U.S.A. The tests reported herein have been
                                                           performed in accordance with its terms of accreditation.
                                                           *As for the range of Accreditation in NVLAP, you may
                                                           refer to the WEB address,
                                                           http://japan.ul.com/resources/emc_accredited/

       NVLAP LAB CODE: 200572-0

     The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
     There is no testing item of "Non-accreditation".

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                     Report Cover Page - 13-EM-F0429 Issue # 14.0


                                                                     Test report No.      : 12104474H-R2
                                                                     Page                 : 2 of 29
                                                                     Issued date          : April 9, 2019
                                                                     FCC ID               : 2AON3-RCS05




                                    REVISION HISTORY
                                  Original Test Report No.: 12104474H

 Revision       Test report No.    Date                Page      Contents
                                                       revised
 - (Original)   12104474H          December 13, 2018   -         -
 1              12104474H-R1       February 26, 2019   P.1       Correction of Date of test of cover sheet
 1              12104474H-R1       February 26, 2019   P.1       Addition of note No.8
 1              12104474H-R1       February 26, 2019   P.4       Addition of note in SECTION 1.
 1              12104474H-R1       February 26, 2019   P.4       Addition of a word to Receipt Date of Sample
 1              12104474H-R1       February 26, 2019   P.5       Addition of notes from a) to d)
 1              12104474H-R1       February 26, 2019   P.5       Addition of “Section 2.1046 to 2.1057” to
                                                                 Specification in the table of Clause 3.2
 1              12104474H-R1       February 26, 2019   P.6       Addition of note in Clause 3.4
 1              12104474H-R1       February 26, 2019   P.8       Addition of “Modulation characteristics” in Test
                                                                 Item of Clause 4.1
 1              12104474H-R1       February 26, 2019   P.8       Correction of Configuration and peripherals of
                                                                 Clause 4.2
 1              12104474H-R1       February 26, 2019   P.10      Correction of Test Distance of Radiated emission
                                                                 test in SECTION 5.
 1              12104474H-R1       February 26, 2019   P.14      - Correction of RBW Correction Factor;
                                                                 From 10log to 20log

                                                                 - Correction of peak power value with
                                                                 modification of RBW Correction Factor;
                                                                 From 25.272 dB to 50.544 dB
 1              12104474H-R1       February 26, 2019   P.14      Addition of the following sentence under the
                                                                 Radiated Power test data;
                                                                 The test method referred to KDB653005.
 1              12104474H-R1       February 26, 2019   P.19      Deletion of note sentence under the Field strength
                                                                 of spurious radiation (above 40 GHz) test data
 1              12104474H-R1       February 26, 2019   P.23      Correction of upper result value of 10.2 V in
                                                                 Frequency Stability test;
                                                                 From 76.676 GHz to 76.666 GHz
 1              12104474H-R1       February 26, 2019   P.24      Correction of voltage of 20 deg. C;
                                                                 From DC 10.8 V to DC 10.2 V
 1              12104474H-R1       February 26, 2019   P.27      Deletion of LIMS ID: 141806 and 141841 from
                                                                 Test Instruments
 1              12104474H-R1       February 26, 2019   P.29      Replacement of setup photo for Field strength of
                                                                 spurious radiation.
 2              12104474H-R2       April 9, 2019       P.4       Correction of Radio Specification in Clause 2.2
 2              12104474H-R2       April 9, 2019       P.5       Correction of “Procedures and results” table in
                                                                 Clause 3.2
 2              12104474H-R2       April 9, 2019       P.10      Correction of the description of [Test setup] 1
                                                                 GHz - 10 GHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                              Test report No.            : 12104474H-R2
                                                                                              Page                       : 3 of 29
                                                                                              Issued date                : April 9, 2019
                                                                                              FCC ID                     : 2AON3-RCS05


CONTENTS                                                                                                                              PAGE

SECTION 1: Customer information.......................................................................................................4
SECTION 2: Equipment under test (E.U.T.) .........................................................................................4
SECTION 3: Test specification, procedures & results..........................................................................5
SECTION 4: Operation of E.U.T. during testing ..................................................................................8
SECTION 5: Radiated Spurious Emission ............................................................................................9
SECTION 6: Frequency Stability .........................................................................................................12
APPENDIX 1: Test data ........................................................................................................................13
    Occupied bandwidth .........................................................................................................................13
    Radiated Power .................................................................................................................................14
    Field strength of spurious radiation...................................................................................................17
    Frequency Stability ...........................................................................................................................23
APPENDIX 2: Test instruments ...........................................................................................................26
APPENDIX 3: Photographs of test setup .............................................................................................28
    Field strength of spurious radiation...................................................................................................28
    Frequency Stability ...........................................................................................................................29




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.      : 12104474H-R2
                                                                        Page                 : 4 of 29
                                                                        Issued date          : April 9, 2019
                                                                        FCC ID               : 2AON3-RCS05


SECTION 1:         Customer information
 Company Name                        :        KEYCOM CORPORATION
 Address                             :        Otsuka Minami Bldg, 3-39-14, Minamiotsuka, Toshimaku, Tokyo ,
                                              170-0005, Japan
 Telephone Number                    :        +81-3-5950-3101
 Facsimile Number                    :        +81-3-5950-3380
 Contact Person                      :        HIROHIDE YAMASHITA

The information provided from the customer is as follows;
- Applicant, Type of Equipment, Model No. on the cover and other relevant pages
- SECTION 1: Customer information
- SECTION 2: Equipment under test (E.U.T.)
- SECTION 4: Operation of E.U.T. during testing
* The laboratory is exempted from liability of any test results affected from the above information in SECTION 2 and 4.



SECTION 2:         Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

 Type of Equipment                   :        Imaging Radar
 Model No.                           :        RCS05
 Serial No.                          :        Refer to Section 4, Clause 4.2
 Rating Voltage                      :        DC 12.0 V
 Receipt Date of Sample              :        October 2, 2018
 (Information from test lab.)
 Country of Mass-production          :        Japan
 Condition of EUT                    :        Production prototype
                                              (Not for Sale: This sample is equivalent to mass-produced items.)
 Modification of EUT                 :        No Modification by the test lab


2.2       Product Description

 Model: RCS05 (referred to as the EUT in this report) is a Imaging Radar.

Radio Specification

 Radio Type                              :    Transceiver
 Frequency Band                          :    76 GHz - 77 GHz
 Frequency of Operation                  :    76.5 GHz
 Occupied frequency bandwidth            :    1 GHz
 FCC Identifier                          :    337MP0N
 RF Output Power                         :    Typ. 6 dBm (8 dBm to 4 dBm)
 Modulation                              :    Pulse modulation
 Antenna Type                            :    Internal Antenna
 Antenna Connector                       :    None (Internal Antenna)
 Antenna Gain                            :    35 dBi
 EIRP                                    :    Typ. 41 dBm ( 43 dBm to 39 dBm)
 Steerable Antenna                       :    Mechanically (Both Transmitting & Receiving Part)
 Usage location                          :    Vehicle-mounted
 Clock Frequency (maximum)               :    124.875 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                   Test report No.         : 12104474H-R2
                                                                                   Page                    : 5 of 29
                                                                                   Issued date             : April 9, 2019
                                                                                   FCC ID                  : 2AON3-RCS05


SECTION 3:            Test specification, procedures & results

3.1         Test Specification

  Test Specification                      :    FCC Part 95 Subpart M
                                               FCC Part 95 final revised on September 20, 2017


  Title                                   :    FCC 47CFR Part95 - PERSONAL RADIO SERVICES
                                               Subpart M - The 76-81 GHz Band Radar Service


3.2         Procedures and results

Item                     Test Procedure                    Specification                 Worst margin          Results       Remarks
Conducted emission       FCC: N/A                          FCC: N/A                      N/A                   N/A           -
                         FCC: ANSI C63.26-2015             FCC: Section 2.1049                                 Complied
Occupied bandwidth       5.4 Occupied bandwidth                                                                              Radiated
                                                                                                               a)
                         FCC: ANSI C63.26-2015             FCC: Section 95.3367
Radiated Power           5.5 Radiated emissions testing    Section 2.1046                See data.
                         ANSI C63.10-2013                  Section 2.1047                                      Complied
                                                                                                                             Radiated
Modulation               6. Standard test methods                                                              b)
characteristics          9. Procedures for testing
                         millimeter-wave systems
                         FCC: ANSI C63.26-2015             FCC: Section 95.3379 (a)
Field strength of        5.5 Radiated emissions testing    Section 2.1053                5.58 dB               Complied
                                                                                                                             Radiated
spurious radiation                                         Section 2.1057                228.633 GHz           c)

                         FCC: ANSI C63.26-2015             FCC: Section 95.3379 (b)
                                                                                                               Complied
Frequency stability      5.6 Frequency stability testing   Section 2.1055                See data.                           Radiated
                                                                                                               d)
Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.

a) Refer to APPENDIX 1 (data of Occupied bandwidth)
b) Refer to APPENDIX 1 (data of Radiated Power and Modulation characteristics)
c) Refer to APPENDIX 1 (data of Field strength of spurious radiation)
d) Refer to APPENDIX 1 (data of Frequency Stability)
Symbols:
  Complied              The data of this test item has enough margin, more than the measurement uncertainty.
  Complied#             The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.
 * In case any questions arise about test procedure, ANSI C63.26-2015 and C63.10-2013 are also referred.


Supplied Voltage Information
The EUT provides the stable voltage constantly to RF Part regardless of input voltage.
DC power supply was used for the test.

Antenna Information
It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT.


3.3         Addition to standard

No addition, exclusion nor deviation has been made from the standard.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                      Test report No.   : 12104474H-R2
                                                                                      Page              : 6 of 29
                                                                                      Issued date       : April 9, 2019
                                                                                      FCC ID            : 2AON3-RCS05


3.4          Uncertainty

EMI

There is no applicable rule of uncertainty in this applied standard. Therefore, the following results are derived depending on whether or not
laboratory uncertainty is applied.

The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.

Ise EM C Lab.

                      Radiated emission
 Test distance                  (+/-)
                       9 kHz - 30 M Hz
3m                          3.3 dB
10 m                        3.2 dB

                                           Radiated emission (Below 1 GHz)
                                   (3 m*) (+/-)                           (10 m*) (+/-)
      Polarity
                                                200 M Hz -        30 M Hz -         200 M Hz -
                     30 M Hz - 200 M Hz
                                                1000 M Hz         200 M Hz          1000 M Hz
   Horizontal              4.8 dB                 5.2 dB           4.8 dB              5.0 dB
    Vertical               4.9 dB                 6.3 dB           4.9 dB              5.0 dB

                                        Radiated emission (Above 1 GHz)
                 (3 m*) (+/-)                                (1 m*) (+/-)           (10 m*) (+/-)
   1 GHz -             6 GHz -                      10 GHz -           26.5 GHz -     1 GHz -
    6 GHz              18 GHz                       26.5 GHz            40 GHz         18 GHz
    5.2 dB              5.5 dB                       5.9 dB              5.9 dB        5.5 dB
*M easurement distance

               Radiated emission (+/-)
 40 GHz - 50 GHz                     4.1 dB
 50 GHz - 75 GHz                     5.5 dB
 75 GHz - 110 GHz                    5.8 dB
 110 GHz - 170 GHz                   5.0 dB
 170 GHz - 260 GHz                   5.0 dB

              Radiated emission (+/-)
             With Block downconverter
 75 GHz - 83 GHz                    4.6 dB




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                    Test report No.          : 12104474H-R2
                                                                                    Page                     : 7 of 29
                                                                                    Issued date              : April 9, 2019
                                                                                    FCC ID                   : 2AON3-RCS05


3.5         Test Location

UL Japan, Inc. Ise EM C Lab.
4383-326 Asama-cho, Ise-shi, M ie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967
                                                                                                                             M aximum
                       IC Registration   Width x Depth x       Size of reference ground plane (m) /
Test site                                                                                              Other rooms           measurement
                       Number            Height (m)            horizontal conducting plane
                                                                                                                             distance
No.1 semi-anechoic                                                                                       No.1 Power source
                         2973C-1           19.2 x 11.2 x 7.7     7.0 x 6.0                                                   10 m
chamber                                                                                                  room
No.2 semi-anechoic
                         2973C-2           7.5 x 5.8 x 5.2       4.0 x 4.0                               -                   3m
chamber
No.3 semi-anechoic                                                                                       No.3 Preparation
                         2973C-3           12.0 x 8.5 x 5.9      6.8 x 5.75                                                  3m
chamber                                                                                                  room
No.3 shielded room       -                 4.0 x 6.0 x 2.7       N/A                                     -                   -
No.4 semi-anechoic                                                                                       No.4 Preparation
                         2973C-4           12.0 x 8.5 x 5.9      6.8 x 5.75                                                  3m
chamber                                                                                                  room
No.4 shielded room       -                 4.0 x 6.0 x 2.7       N/A                                     -                   -
No.5 semi-anechoic
                         -                 6.0 x 6.0 x 3.9       6.0 x 6.0                               -                   -
chamber
No.6 shielded room       -                 4.0 x 4.5 x 2.7       4.0 x 4.5                               -                   -
No.6 measurement
                         -                 4.75 x 5.4 x 3.0      4.75 x 4.15                             -                   -
room
No.7 shielded room       -                 4.7 x 7.5 x 2.7       4.7 x 7.5                               -                   -
No.8 measurement
                         -                 3.1 x 5.0 x 2.7       3.1 x 5.0                               -                   -
room
No.9 measurement
                         -                 8.8 x 4.6 x 2.8       2.4 x 2.4                               -                   -
room
No.11 measurement
                         -                 6.2 x 4.7 x 3.0       4.8 x 4.6                               -                   -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0m for No.1, No.2, No.3, and No.4 semi-
anechoic chambers and No.3 and No.4 shielded rooms.




3.6         Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.        : 12104474H-R2
                                                                          Page                   : 8 of 29
                                                                          Issued date            : April 9, 2019
                                                                          FCC ID                 : 2AON3-RCS05


SECTION 4:         Operation of E.U.T. during testing

4.1       Operating Mode(s)

  Mode                                                     Test Item
  Normal operating mode                                    Occupied bandwidth
                                                           Radiated Power
                                                           Modulation characteristics
                                                           Field strength of spurious radiation
                                                           Frequency stability
  Power of the EUT was set by the software as follows;
  Power settings:        Same as production model
  Software:              Ver. 1.33
  This setting of software is the worst case. Any conditions under the normal use do not exceed the condition of
  setting. In addition, end users cannot change the settings of the output power of the product.


4.2       Configuration and peripherals



                                                            B
                           A
              5                           2                                            3          C        4




                               1



                      DC 12.0 V
                                                                                                      AC 120V / 60Hz


                                                                                            : Standard Ferrite Core


        * Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions.

Description of EUT and Support equipment
  No.          Item        Model number                  Serial number               Manufacturer                   Remarks
  A     Imaging Radar    RCS05                        14418F28-02             KEYCOM CORPORATION                   EUT
  B     Laptop PC        CF-N8HWCDP5                  9LKSA04L58              Panasonic                            -
  C     AC Adapter       CF-AA63720                   6372BM409X1490B         Panasonic                            -

List of cables used
  No.             Name                   Length (m)                        Shield                              Remarks
                                                               Cable                Connector
  1      DC Cable                  2.0                       Unshielded             Unshielded         -
  2      USB Cable                 1.4                        Shielded               Shielded          -
  3      DC Cable                  1.0                       Unshielded             Unshielded         -
  4      AC Cable                  0.8                       Unshielded             Unshielded         -
  5      Coaxial Cable             0.5                        Shielded               Shielded          -




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.      : 12104474H-R2
                                                                         Page                 : 9 of 29
                                                                         Issued date          : April 9, 2019
                                                                         FCC ID               : 2AON3-RCS05


SECTION 5: Radiated Spurious Emission
Test Procedure

[For below 1 GHz]
EUT was placed on a urethane platform of nominal size, 1.0 m by 1.5 m, raised 0.8 m above the conducting ground
plane. The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

[For above 1 GHz, up to 40 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 1.0 m, raised 1.5 m above the conducting ground
plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with absorbent materials lined on a
ground plane.


The height of the measuring antenna varied between 1 m and 4 m (frequency range 9 kHz – 30 MHz: loop antenna was
fixed height at 1.0 m) and EUT was rotated a full revolution in order to obtain the maximum value of the electric field
strength.
The measurements were performed for both vertical and horizontal antenna polarization with the Test Receiver, or the
Spectrum Analyzer.
The measurements were made with the following detector function of the test receiver and the Spectrum analyzer (in
linear voltage average mode).
The test was made with the detector (RBW/VBW) in the following table.
When using Spectrum analyzer, the test was made with adjusting span to zero by using peak hold.

Test Antennas are used as below;
    Frequency          Below 30 MHz              30 MHz to 200 MHz       200 MHz to 1 GHz        Above 1 GHz
    Antenna Type       Loop                      Biconical               Logperiodic             Horn


    Frequency            9 kHz to           150 kHz to         30 MHz to           1 GHz to 40 GHz
                         150 kHz            30 MHz             1 GHz
    Instrument used      Test Receiver      Test Receiver      Test Receiver       Spectrum Analyzer
    Detector             CISPR QP,          CISPR QP,          CISPR QP            Peak             Average *1)
                         Average            Average
    IF Bandwidth         200 Hz             9 kHz              120 kHz         RBW: 1 MHz         RBW: 1 MHz
                                                                               VBW: 3 MHz         VBW: 3 MHz
*1) An RMS average mode was used: 1 ms or less averaging time (integration time period for each spectrum analyzer
bin; spectrum analyzer sweeptime / number-of-bins not exceeding one millisecond)




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                 Test report No.        : 12104474H-R2
                                                                 Page                   : 10 of 29
                                                                 Issued date            : April 9, 2019
                                                                 FCC ID                 : 2AON3-RCS05


[Test setup]
 Below 1 GHz
                                                      Test Distance: 3 m




 1 GHz - 10 GHz
                                                      Distance Factor: 20 x log (4.0 m*/3.0 m) = 2.5 dB
                                                      * Test Distance: (3 + Test Volume /2) - r = 4.0 m

                                                      Test Volume: 2 m
                                                      (Test Volume has been calibrated based on CISPR 16-1-4.)
                                                       r = 0.0 m

                                                      * The test was performed with r = 0.0 m since that yielded
                                                      the worst emission levels from the EUT.



 10 GHz – 40 GHz
                                                      Distance Factor: 20 x log (1.0 m* / 3.0 m) = -9.54 dB
                                                      *Test Distance: 1 m




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.       : 12104474H-R2
                                                                          Page                  : 11 of 29
                                                                          Issued date           : April 9, 2019
                                                                          FCC ID                : 2AON3-RCS05


[Above 40 GHz]
The test was performed based on “Procedures for testing millimeter-wave systems” of ANSI C63.10-2013. The EUT was
placed on a urethane platform, raised 1.5 m above the conducting ground plane. The measurements were performed on
handheld method.

Set spectrum analyzer RBW, VBW, span, etc., to the proper values. Note these values. Enable two traces—one set to
“clear write,” and the other set to “max hold.” Begin hand-held measurements with the test antenna (horn) at a distance
of 1 m from the EUT in a horizontally polarized position. Slowly adjust its position, entirely covering the plane 1 m from
the EUT. Observation of the two active traces on the spectrum analyzer will allow refined horn positioning at the point(s)
of maximum field intensity. Repeat with the horn in a vertically polarized position. If the emission cannot be detected at
1 m, reduce the RBW to increase system sensitivity. Note the value. If the emission still cannot be detected, move the
horn closer to the EUT, noting the distance at which a measurement is made.

Note the maximum level indicated on the spectrum analyzer. Adjust this level, if necessary, by the antenna gain,
conversion loss of the external mixer and gain of LNA used, at the frequency under investigation. Calculate the field
strength of the emission at the measurement distance from the Friis’ transmission equation.

    Frequency                       40 GHz to      50 GHz to     77 GHz to      83 GHz to     110 GHz to 170 GHz to
                                    50 GHz         76 GHz        83 GHz         110 GHz       170 GHz    231 GHz
    Final measurement distance      1.0 m          1.0 m         1.0 m          1.0 m         0.02 m     0.02 m
    with 1 MHz Peak detector


[About fundamental measurement]
The carrier levels were confirmed at maximum direction of transmission. The maximum direction was searched under
carefully since beam-widths are extremely narrow.

The carrier levels were measured in the far field. The distance of the far field was calculated from follow equation.
                 2D2
            r
                  
where
         r is the distance from the radiating element of the EUT to the edge of the far field, in m
         D is the largest dimension of both the radiating element and the test antenna (horn), in m
         (The antenna aperture size of test antenna was used for this caluculation.)
         Lambda is the wavelength of the emission under investigation [300/f (MHz)], in m

  Frequency      Wavelength               Maximum Dimention                     Far Field
                                   EUT       Test Antenna   Maximum             Boundary
                  Lambda                                        D                   r
    [GHz]          [mm]             [m]           [m]          [m]                [m]
     76.5           3.9          0.088000     0.026162      0.088000             3.950

The test was made on EUT at the normal use position.

The test results and limit are rounded off to one decimal place, so some differences might be observed.

Measurement range               : 9 kHz - 231 GHz
Test data                       : APPENDIX
Test result                     : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                       Test report No.   : 12104474H-R2
                                                                       Page              : 12 of 29
                                                                       Issued date       : April 9, 2019
                                                                       FCC ID            : 2AON3-RCS05


SECTION 6: Frequency Stability
Test Procedure
The block downconverter was placed in side of the temperature chamber’s drain hole.

The power supply was set to nominal operating voltage (100 %), and the spectrum mask was measured at 20 deg. C.
After that, EUT power supply was varied between 85 % and 115 % of nominal voltage and the frequency excursion of
the EUT emission mask was recorded.

The EUT operating temperature was raised to 50 deg. C, and the frequency excursion of the EUT emission mask was
recorded. Measurements were repeated at each 10 deg. C decrement down to –20 deg. C.

Both lower and upper frequencies of the 99 % OBW were recorded.

Test data           : APPENDIX
Test result         : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                      Test report No.   : 12104474H-R2
                                                                      Page              : 13 of 29
                                                                      Issued date       : April 9, 2019
                                                                      FCC ID            : 2AON3-RCS05


APPENDIX 1: Test data

                                               Occupied bandwidth

                     Report No.                 12104474H
                     Test place                 Ise EMC Lab. No.8 Measurement Room
                     Date                       November 6, 2018
                     Temperature / Humidity     22 deg. C / 50 % RH
                     Engineer                   Ryota Yamanaka
                     Mode                       Normal operating mode



                                          Frequency           99 % Occupied
                                                                bandwidth
                                              [GHz]               [MHz]
                                                      76.5          336.6521


                                               Occupied bandwidth




        The measurement was performed with Peak detector and Max Hold since the duty cycle was not 100 %.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                           Test report No.           : 12104474H-R2
                                                                                           Page                      : 14 of 29
                                                                                           Issued date               : April 9, 2019
                                                                                           FCC ID                    : 2AON3-RCS05


                                                          Radiated Power

                        Report No.                      12104474H
                        Test place                      Ise EMC Lab. No.4 Semi Anechoic Chamber
                        Date                            November 7, 2018
                        Temperature / Humidity          23 deg. C / 50 % RH
                        Engineer                        Ryota Yamanaka
                        Mode                            Normal operating mode


Measured data in Test modes
   Mode         Power         Freq.       Measured      Tested             Rx          Down             IF            FSL              EIRP
                                           Power       Distance          Antenna      Converter        Cable
                                                                          Gain          Gain           Loss
                             [GHz]         [dBm]         [m]              [dBi]         [dB]           [dB]           [dB]       [dBm]        [mW]
Spectrum     Average             76.5         -36.19           3.95          22.33         14.80           1.42          82.05      10.15       10.34
Analyzer     Peak                76.5         -55.48           3.95          22.33         14.80           1.42          82.05      -9.14        0.12

Calculating formula:
              FSL (Free Space path Loss) = 10 * log10(( 4 * Pi * Tested Distance / Lambda ) ^2)
              EIRP = Measured Power - Rx Antenna Gain - Down Converter Gain + IF Cable Loss + FSL

These calculation results are same as results which were calculated with formulas described in the Section 9 of ANSI C63.10-2013.




Final result in Normal operation mode
                                                                EIRP
                            Spectrum        Duty                Result                    Limit        Margin
                            Analyzer       Factor
                             [dBm]          [dB]        [mW]             [dBm]            [dBm]         [dB]
Average power                    10.15        23.565     2350.68            33.71                 50       16.29
Peak power                        -9.14       -             0.12            -9.14                 55       64.14



Reference data of peak power.
                                                                          EIRP
                                                         RBW
                            Spectrum     OBW           Correction                Result                Limit         Margin
                            Analyzer                   Factor *1
                              [dBm]      [MHz]           [dB]             [mW]            [dBm]        [dBm]          [dB]
Peak power                        -9.14   336.652          50.544         13805.65           41.40              55       13.60
*1 RBW Correction Factor = 20log * (OBW)

For the peak power result, it is a maximum power.
The test method referred to KDB653005.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                       Test report No.    : 12104474H-R2
                                                                       Page               : 15 of 29
                                                                       Issued date        : April 9, 2019
                                                                       FCC ID             : 2AON3-RCS05


                                                 Radiated Power

                     Report No.                 12104474H
                     Test place                 Ise EMC Lab. No.4 Semi Anechoic Chamber
                     Date                       November 7, 2018
                     Temperature / Humidity     23 deg. C / 50 % RH
                     Engineer                   Ryota Yamanaka
                     Mode                       Normal operating mode

                                                Spectrum Analyzer




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.      : 12104474H-R2
                                                                        Page                 : 16 of 29
                                                                        Issued date          : April 9, 2019
                                                                        FCC ID               : 2AON3-RCS05


                                              Modulation characteristics

                     Report No.                  12104474H
                     Test place                  Ise EMC Lab. No.4 Semi Anechoic Chamber
                     Date                        November 7, 2018
                     Temperature / Humidity      23 deg. C / 50 % RH
                     Engineer                    Ryota Yamanaka
                     Mode                        Normal operating mode

[Duty Factor]

                                                Tx On          Tx On + Off            Duty factor
                                                 time             time
                                                 [μs]             [μs]                    [dB]
                   Measured                           0.0044           1.000                 -23.565
                   Declared *                          0.005           1.000                 -23.010

                   Duty factor = 10 * log (Tx On time / Tx On + Off time)
                   * See the application document.
[Data]

                                                          Duty




                       * This Duty Cycle is the worst case. Transmitting time does not exceed it.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                              Test report No.           : 12104474H-R2
                                                                                              Page                      : 17 of 29
                                                                                              Issued date               : April 9, 2019
                                                                                              FCC ID                    : 2AON3-RCS05


                                               Field strength of spurious radiation

                Report No.                         12104474H
                Test place                         Ise EMC Lab.
                Semi Anechoic Chamber              No.3                           No.3                          No.3
                Date                               October 2, 2018                October 3, 2018               October 29, 2018
                Temperature / Humidity             23 deg. C / 51 % RH            23 deg. C / 48 % RH           22 deg. C / 55 % RH
                Engineer                           Ryota Yamanaka                 Junki Nagatomi                Ryota Yamanaka
                                                   (1 GHz - 40 GHz)               (9 kHz - 30 MHz)              (30 MHz - 1 GHz)
                Mode                               Normal operating mode


        Polarity   Frequency Detector Reading Ant.Fac. Loss               Gain     Result     Limit     Margin          Remark
                     [MHz]                [dBuV] [dB/m]          [dB]      [dB] [dBuV/m] [dBuV/m] [dB]
        Hori          168.882 QP             33.0       15.8        8.9      32.0     25.7        43.5     17.8
        Hori          295.610 QP             42.9       13.5        9.9      32.0     34.3        46.0     11.7
        Hori          499.501 QP             33.2       18.1       11.3      32.0     30.6        46.0     15.4
        Hori          528.000 QP             35.3       17.9       11.4      32.1     32.5        46.0     13.5
        Hori          624.000 QP             31.4       19.6       11.9      32.1     30.8        46.0     15.2
        Hori          874.122 QP             34.1       22.1       13.1      31.3     38.0        46.0       8.0
        Hori       12750.050 PK              49.2       38.9       -3.2      33.3     51.6        73.9     22.3
        Hori       12750.050 AV              45.0       38.9       -3.2      33.3     47.4        53.9       6.5
        Vert          168.882 QP             35.6       15.8        8.9      32.0     28.3        43.5     15.2
        Vert          299.311 QP             42.3       13.5       10.0      32.0     33.8        46.0     12.2
        Vert          499.500 QP             32.9       18.1       11.3      32.0     30.3        46.0     15.7
        Vert          528.000 QP             31.0       17.9       11.4      32.1     28.2        46.0     17.8
        Vert          624.000 QP             30.1       19.6       11.9      32.1     29.5        46.0     16.5
        Vert          874.122 QP             34.5       22.1       13.1      31.3     38.4        46.0       7.6
        Vert       12750.050 PK              46.9       38.9       -3.2      33.3     49.3        73.9     24.6
        Vert       12750.050 AV              40.2       38.9       -3.2      33.3     42.6        53.9     11.3
        Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier)
        *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
        *The 10th harmonic was not seen so the result was its base noise level.
        Distance factor:      1 GHz - 10 GHz        20log (4.0 m / 3.0 m) = 2.5 dB
                              10 GHz - 40 GHz 20log (1.0 m / 3.0 m) = -9.54 dB




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                        Test report No.             : 12104474H-R2
                                                                                                        Page                        : 18 of 29
                                                                                                        Issued date                 : April 9, 2019
                                                                                                        FCC ID                      : 2AON3-RCS05


                                                              Field strength of spurious radiation
                                                                     (Plot data, Worst case)

              Report No.                                        12104474H
              Test place                                        Ise EMC Lab.
              Semi Anechoic Chamber                             No.3                           No.3                       No.3
              Date                                              October 2, 2018                October 3, 2018            October 29, 2018
              Temperature / Humidity                            23 deg. C / 51 % RH            23 deg. C / 48 % RH        22 deg. C / 55 % RH
              Engineer                                          Ryota Yamanaka                 Junki Nagatomi             Ryota Yamanaka
                                                                (1 GHz - 40 GHz)               (9 kHz - 30 MHz)           (30 MHz - 1 GHz)
              Mode                                              Normal operating mode



                                                                                     Horizontal
                                               80

                                               70
                     Field strength [dBuV/m]




                                               60

                                               50

                                               40

                                               30

                                               20

                                               10
                                                    10               100                         1000                10000
                                                                                      Frequency [MHz]

                                                         QP   Peak         Average         QP Limit     Peak Limit        Average Limit




                                                                                      Vertical
                                               80

                                               70
                     Field strength [dBuV/m]




                                               60

                                               50

                                               40

                                               30

                                               20

                                               10
                                                    10               100                         1000                10000
                                                                                      Frequency [MHz]

                                                         QP   Peak         Average         QP Limit     Peak Limit        Average Limit



           *These plots data contains sufficient number to show the trend of characteristic features for EUT.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                                    Test report No.                : 12104474H-R2
                                                                                                                    Page                           : 19 of 29
                                                                                                                    Issued date                    : April 9, 2019
                                                                                                                    FCC ID                         : 2AON3-RCS05


                                           Field strength of spurious radiation (above 40 GHz)

                      Report No.                                  12104474H
                      Test place                                  Ise EMC Lab.
                      Semi Anechoic Chamber                       No. 3
                      Date                                        October 4, 2018
                      Temperature / Humidity                      23 deg. C / 63 % RH
                      Engineer                                    Ryota Yamanaka
                                                                  50 GHz - 231 GHz
                      Mode                                        Normal operating mode


      Freq.       Reading        Rx      Filter    LNA       Mixer       IF             IF     Meas.     FSL          EIRP            Power density at 3 m         Remarks
                                ant.     loss      gain      loss       amp.          cable    range                                Result   Limit     Margin
                                gain                                    gain           loss      D
     [GHz]        [dBm]        [dBi]     [dB]      [dB]       [dB]      [dB]          [dB]      [m]      [dB]    [dBm]       [mW] [pW/cm2] [pW/cm2]      [dB]
       49.974       -57.66       22.64     0.00      22.91       0.00      0.00           9.19     1.0     66.42   -27.60   0.001739  1.54      600        25.91
       50.852       -78.30       22.73     0.00      25.72      46.70     32.07           0.10     1.0     66.57   -45.45   0.000028  0.03      600        43.77
       75.915       -68.76       22.26     0.00       0.00     -14.73      0.00           1.24     1.0     70.05   -34.46   0.000358  0.32      600        32.78
       82.354       -68.94       22.94     0.00       0.00     -12.33      0.00           2.62     1.0     70.76   -30.83   0.000825  0.73      600        29.15
       83.639       -71.01       23.11     2.59       0.00      42.24     32.07           0.10     1.0     70.89   -10.37   0.091875 81.24      600         8.68
      101.449       -74.08       24.76     0.31       0.00      44.43     32.07           0.10     1.0     72.57   -13.50   0.044686 39.51      600        11.81
      116.969       -91.58       22.53     0.00       0.00      57.10      0.00           0.00    0.02     39.82   -17.18   0.019124 16.91      600        15.50
      131.297       -93.29       22.98     0.00       0.00      52.72      0.00           0.00    0.02     40.83   -22.72   0.005341  4.72      600        21.04
      153.066       -88.32       23.35     0.00       0.00      57.14      0.00           0.00    0.02     42.16   -12.37   0.057928  51.2      600        10.69
      154.770       -94.13       23.37     0.00       0.00      56.57      0.00           0.00    0.02     42.26   -18.67   0.013574  12.0      600        16.99
      172.654       -92.08       22.46     0.00       0.00      59.24      0.00           0.00    0.02     43.21   -12.10   0.061715  54.6      600        10.41
      192.168       -93.31       22.88     0.00       0.00      59.41      0.00           0.00    0.02     44.14   -12.64   0.054413  48.1      600        10.96
      211.923       -93.84       23.19     0.00       0.00      60.59      0.00           0.00    0.02     44.99   -11.45   0.071564  63.3     1000        11.99
      228.633       -89.42       23.34     0.00       0.00      62.07      0.00           0.00    0.02     45.65    -5.05   0.312761 276.5     1000         5.58

                                                                                        2
   Calculation:              FSL (Free Space path Loss) = 10 * log ((4 * Pi * D / λ ) )
                             EIRP = Reading - Rx ant. gain + Filter loss - LNA gain + Mixer loss - IF amp. gain + IF cable loss + FSL
                                                                                  2
                             Power density Result at 3 m = EIRP / (4 * Pi * 300 )

                             These calculation results are same as results which were calculated with formulas described in the Section 9 of ANSI C63.10-2013.
                                       The equipment were not used for factor 0 dB of the data sheets.


                              There is no spurious emission from 40 GHz to 231 GHz except for operating band.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                              Test report No.    : 12104474H-R2
                                                              Page               : 20 of 29
                                                              Issued date        : April 9, 2019
                                                              FCC ID             : 2AON3-RCS05


                           Field strength of spurious radiation (above 40 GHz)

                    40 GHz – 50 GHz                                 50 GHz – 75 GHz




                    75 GHz – 76 GHz                                 81 GHz – 83 GHz




                    83 GHz – 90 GHz                                90 GHz – 110 GHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                              Test report No.    : 12104474H-R2
                                                              Page               : 21 of 29
                                                              Issued date        : April 9, 2019
                                                              FCC ID             : 2AON3-RCS05


                           Field strength of spurious radiation (above 40 GHz)

                  110 GHz – 130 GHz                               130 GHz – 152 GHz




                  152 GHz – 154 GHz                               154 GHz – 170 GHz




                  170 GHz – 190 GHz                               190 GHz – 210 GHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                              Test report No.    : 12104474H-R2
                                                              Page               : 22 of 29
                                                              Issued date        : April 9, 2019
                                                              FCC ID             : 2AON3-RCS05


                           Field strength of spurious radiation (above 40 GHz)

                  210 GHz – 228 GHz                               228 GHz – 231 GHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.      : 12104474H-R2
                                                                          Page                 : 23 of 29
                                                                          Issued date          : April 9, 2019
                                                                          FCC ID               : 2AON3-RCS05


                                                 Frequency Stability

                     Report No.                  12104474H
                     Test place                  Ise EMC Lab. No.8 Measurement Room
                     Date                        November 9, 2018
                     Temperature / Humidity      22 deg. C / 51 % RH
                     Engineer                    Ryota Yamanaka
                     Mode                        Normal operating mode

         Test Condition           Measured -20 dBc Frequency                              Remarks
  Temperature    Power Supply     Lower Result   Upper Result
    [deg. C]           [V]          [GHz]           [GHz]
              50           12.0         76.213          76.647
              40           12.0         76.217          76.650
              30           12.0         76.232          76.646
              20           12.0         76.194          76.650
              20           10.2         76.232          76.666 85 % of the minimum operating voltage, DC 12V * 0.85
              20           13.8         76.230          76.653 115 % of the maximum operating voltage, DC 12 V * 1.15
              10           12.0         76.157          76.670
               0           12.0         76.098          76.673
             -10           12.0         76.088          76.675
             -20           12.0         76.027          76.767



 Fundamental emissions were contained within the frequency band 76 GHz - 77 GHz during all conditions of operation.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                 Test report No.   : 12104474H-R2
                                                                 Page              : 24 of 29
                                                                 Issued date       : April 9, 2019
                                                                 FCC ID            : 2AON3-RCS05


                                               Frequency Stability

                  50 deg. C, DC 12.0 V                               40 deg. C, DC 12.0 V




                  30 deg. C, DC 12.0 V                               20 deg. C, DC 12.0 V




                  20 deg. C, DC 10.2 V                               20 deg. C, DC 13.8 V




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                 Test report No.   : 12104474H-R2
                                                                 Page              : 25 of 29
                                                                 Issued date       : April 9, 2019
                                                                 FCC ID            : 2AON3-RCS05


                                               Frequency Stability

                  10 deg. C, DC 12.0 V                               0 deg. C, DC 12.0 V




                 -10 deg. C, DC 12.0 V                               -20 deg. C, DC 12.0 V




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                            Test report No.         : 12104474H-R2
                                                                            Page                    : 26 of 29
                                                                            Issued date             : April 9, 2019
                                                                            FCC ID                  : 2AON3-RCS05


APPENDIX 2: Test instruments
Test Instruments (1/2)
Test   LIMS ID Description              Manufacturer        Model           Serial            Last          Calibration   Cal Int
item                                                                                          Calibration   Due Date
                                                                                              Date
RE     141152   EMI measurement         TSJ                 TEPTO-DV        -                 -             -             -
                program
RE     141265   Logperiodic             Schwarzbeck         VUSLP9111B      911B-190          5/31/2018     5/31/2019     12
                Antenna(200-1000MHz)
RE     141317   Coaxial Cable           Fujikura/Agilent    -               -                 2/23/2018     2/28/2019     12
RE     141203   Attenuator(6dB)         Weinschel Corp      2               BK7970            11/5/2018     11/30/2019    12
RE     141578   Pre Amplifier           AGILENT             8447D           2944A10845        9/19/2018     9/30/2019     12
RE     141542   Digital Tester          Fluke Corporation   FLUKE 26-3      78030611          8/21/2018     8/31/2019     12
RE     141427   Biconical Antenna       Schwarzbeck         VHA9103B        8031              5/31/2018     5/31/2019     12
RE     141582   Pre Amplifier           SONOMA              310             260834            2/27/2018     2/28/2019     12
                                        INSTRUMENT
RE     141222   Coaxial Cable           FUJIKURA            3D-2W(12m)/     -                 2/23/2018     2/28/2019     12
                                                            5D-2W(5m)/
                                                            5D-2W(0.8m)/5
RE     159670   Coaxial Cable           UL Japan Inc.       -               -                 11/7/2018     11/30/2019    12
RE     142152   Loop Antenna            Rohde & Schwarz     HFH2-Z2         836553/009        11/22/2017    11/30/2018    12
RE     141942   Test Receiver           Rohde & Schwarz     ESCI            100300            8/8/2018      8/31/2019     12
RE     141885   Spectrum Analyzer       AGILENT             E4448A          US44300523        11/7/2018     11/30/2019    12
RE     142182   Measure                 KOMELON             KMC-36          -                 -             -             -
RE     142004   AC2_Semi Anechoic       TDK                 Semi Anechoic   DA-06902          6/29/2018     6/30/2020     24
                Chamber(NSA)                                Chamber 3m
RE     141556   Thermo-Hygrometer       CUSTOM              CTH-201         0003              12/21/2017    12/31/2018    12
RE     142013   AC3_Semi Anechoic       TDK                 Semi Anechoic   DA-10005          4/6/2018      4/30/2019     12
                Chamber(SVSWR)                              Chamber 3m
RE     141532   DIGITAL HiTESTER        HIOKI               3805            51201197          1/9/2018      1/31/2019     12
RE     141507   Horn Antenna 1-18GHz    Schwarzbeck         BBHA9120D       258               6/7/2018      6/30/2019     12
RE     141513   Horn Antenna 15-40GHz   Schwarzbeck         BBHA9170        BBHA9170306       6/7/2018      6/30/2019     12
RE     142183   Measure                 KOMELON             KMC-36          -                 -             -             -
RE     141580   MicroWave System        AGILENT             83017A          MY39500779        3/13/2018     3/31/2019     12
                Amplifier
RE     141417   Microwave Cable         Junkosha            MWX221          1404S374(1m) /    5/7/2018      5/31/2019     12
                                                                            1405S074(5m)
RE     142008   AC3_Semi Anechoic       TDK                 Semi Anechoic   DA-10005          6/26/2018     6/30/2020     24
                Chamber(NSA)                                Chamber 3m
RE     141554   Thermo-Hygrometer       CUSTOM              CTH-180         1301              1/24/2018     1/31/2019     12
RE     148898   Attenuator              KEYSIGHT            8491A           MY52462282        10/3/2018     10/31/2019    12
RE     141425   Biconical Antenna       Schwarzbeck         BBA9106         1302              6/1/2018      6/30/2019     12
RE     141397   Coaxial Cable           UL Japan            -               -                 6/13/2018     6/30/2019     12
RE     141545   DIGITAL HiTESTER        HIOKI               3805            51201148          1/9/2018      1/31/2019     12
RE     141951   EMI Test Receiver       Rohde & Schwarz     ESR26           101408            1/30/2018     1/31/2019     12
RE     141267   Logperiodic             Schwarzbeck         VUSLP9111B      911B-192          6/1/2018      6/30/2019     12
                Antenna(200-1000MHz)
RE     142227   Measure                 KOMELON             KMC-36          -                 -             -             -
RE     141583   Pre Amplifier           SONOMA              310             260833            2/27/2018     2/28/2019     12
                                        INSTRUMENT
RE     142011   AC4_Semi Anechoic       TDK                 Semi Anechoic   DA-10005          6/28/2018     6/30/2020     24
                Chamber(NSA)                                Chamber 3m
RE     141562   Thermo-Hygrometer       CUSTOM              CTH-180         1501              1/24/2018     1/31/2019     12
RE     142041   Horn Antenna            Oshima Prototype    A16-186         1                 9/11/2018     9/30/2019     12
                                        Engineering Co.
RE     142029   Horn Antenna            WiseWave            ARH1523-02      10766-01          10/30/2017    10/31/2018    12




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                              Test report No.         : 12104474H-R2
                                                                              Page                    : 27 of 29
                                                                              Issued date             : April 9, 2019
                                                                              FCC ID                  : 2AON3-RCS05


Test Instruments (2/2)
Test   LIMS ID Description               Manufacturer        Model            Serial            Last          Calibration   Cal Int
item                                                                                            Calibration   Due Date
                                                                                                Date
RE     142055   Power Amplifier          SAGE Millimeter, Inc. SBP-5037532015- 11599-01         12/22/2017    12/31/2018    12
                                                               1515-N1
RE     142047   Preselected Millimeter   AGILENT               11974V-E01      3001A00412       7/13/2018     7/31/2019     12
                Mixer
RE     142032   Microwave Cable          Huber+Suhner        SUCOFLEX102      37511/2           9/4/2018      9/30/2019     12
RE     142033   Microwave Cable          Huber+Suhner        SUCOFLEX102      37512/2           9/4/2018      9/30/2019     12
RE     142031   Horn Antenna             WiseWave            ARH1023-02       10766-01          10/30/2017    10/31/2018    12
RE     141329   Microwave Cable 1G-      Suhner              SUCOFLEX102      28635/2           4/11/2018     4/30/2019     12
                40GHz
RE     142050   Block Downconverter      KEYSIGHT            PS-X30-W10117A 13715               2/1/2018      2/28/2019     12
RE     142048   Harmonic Mixer           AGILENT             11970W         2521 A01909         7/9/2018      7/31/2019     12
RE     142042   High Pass Filter 81-     VCSS                HPF-10-778030 201                  8/22/2018     8/31/2019     12
                110GHz
RE     142036   Horn Antenna             Custom Microwave    HO6R             -                 9/11/2018     9/30/2019     12
                                         Inc.
RE     142049   Harmonic Mixer           OML INC.            M06HWD           D100709-1         10/31/2018    10/31/2019    12
RE     142026   Diplexer                 OML INC.            DPL26            -                 10/17/2017    10/31/2018    12
RE     142038   Horn Antenna             Custom Microwave    HO5R             -                 9/11/2018     9/30/2019     12
                                         Inc.
RE     142039   Horn Antenna             Custom Microwave    HO4R             -                 9/11/2018     9/30/2019     12
                                         Inc.
RE     142053   Harmonic Mixer           OML INC.            M04HWD           Y100709-1         10/31/2018    10/31/2019    12
RE     141962   Digital Oscilloscope     Rohde & Schwarz     RTO1004          200355            8/30/2018     8/31/2019     12
RE     141440   Temperature and          TABAI ESPEC         PL-1KP           14019569          4/10/2018     4/29/2019     12
                Humidity Chamber
RE     141567   Thermo-Hygrometer        CUSTOM              CTH-201         0008          1/24/2018          1/31/2019     12
RE     142529   Detector                 HEROTEK, INC.       DT1840P         484823        -                  -             -
RE     151897   Microwave Cable          RINEI SEIKI         SF101EA/11PC24/ SN MY1726/1EA 4/19/2018          4/30/2019     12
                                                             11PC24/2.5M


*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that Calibration
is not required (e.g. software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

[Below 40 GHz]
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

[Above 40 GHz]
Acceptance criteria for untraceable equipment was formulated according to ISO/IEC 17025 5.6.2.2.2, and the
regular inspection was performed based on it annually.
For 40 GHz – 110 GHz, power sensor is calibrated by manufacturer, and the measured calibration data is used as
in-house reference. The calibration data by manufacturer is checked for acceptance by a calorie meter except for
some frequency bands.
For above 110 GHz, output level of millimeter wave source module is used as the reference, and inspection by the
calorie meter is performed.
Electric power is checked with the calorie meter by measuring resistance and voltage of reference resistor.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

Test Item:           RE: Radiated Emission test



UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124



Document Created: 2019-04-26 07:38:27
Document Modified: 2019-04-26 07:38:27

© 2024 FCC.report