test report DSC

FCC ID: 2AOKM-HDODY

Test Report

Download: PDF
FCCID_4316395

                       Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                  Report No: CCISE190503701v01

1        Cover Page

                      FCC/ IC REPORT
    Applicant:                          Remote Tech LLC
    Address of Applicant:               310 ALDER RD, DOVER DE 19904 USA
    Equipment Under Test (EUT)

     Product Name:                      keyless transmitter
     Model No.:                         RT-HDOHY5, RT-HDOHY6
    FCC ID:                             2AOKM-HDODY
    Canada IC:                          24223-HDODY
    Applicable standards:               FCC CFR Title 47 Part 15 Subpart C Section 15.231
                                        RSS-210 Issue 9 August 2016 Annex A Section A.1.1
                                        RSS-Gen Issue 5 April 2018
    Date of sample receipt:             13 May, 2019
    Date of Test:                       14 May, to 24 May, 2019
    Date of report issue:               27 May, 2019
    Test Result:                        PASS*

*    In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




        Bruce Zhang
     Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                             Report No: CCISE190503701v01


2      Version
     Version No.                         Date                                    Description
            00                     27 May, 2019                                    Original
                                                                  Updated 11 to 18 pages of test data and
            01                     10 Jun., 2019
                                                                  test charts and 99% Occupy Bandwidth




    Prepared By:                                                         Date:           27 May, 2019

                                       Test Engineer

    Check By:                                                            Date:           27 May, 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 2 of 33


                                                                                                                   Report No: CCISE190503701v01

3         Contents
                                                                                                                                                                               Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST MODE ............................................................................................................................................................ 5
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 5
    5.5         LABORATORY FACILITY.......................................................................................................................................... 6
    5.6         LABORATORY LOCATION ....................................................................................................................................... 6
    5.7         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1     ANTENNA REQUIREMENT ....................................................................................................................................... 8
    6.2     RADIATED EMISSION ............................................................................................................................................. 9
       6.2.1 Field Strength Of The Fundamental Signal .............................................................................................. 11
       6.2.2 Spurious Emissions ..................................................................................................................................... 14
    6.3     20DB BANDWIDTH ............................................................................................................................................... 18
    6.4     DURATION TIME ................................................................................................................................................... 20
    6.5     FREQUENCY STABILITY ........................................................................................................................................ 22
7       TEST SETUP PHOTOS...................................................................................................................................... 24
8       EUT CONSTRUCTIONAL PHOTOS ................................................................................................................. 25




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                          Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                        Page 3 of 33


                                                                              Report No: CCISE190503701v01

4       Test Summary
                                                                 Section in CFR 47
                     Test Item                                                                        Result
                                                           FCC                     IC
               Antenna requirement                        15.203              RSS-GEN 6.8              Pass
                                                                          RSS-210 Annex A
     Field strength of the fundamental signal           15.231 (b)                                     Pass
                                                                          Section A.1.2 (a)
                                                                          RSS-210 Annex A
                Spurious emissions                  15.231 (b)/15.209                                  Pass
                                                                          Section A.1.2 (b)
                                                                          RSS-210 Annex A
                 20dB Bandwidth                         15.231 (c)                                     Pass
                                                                            Section A.1.3
                                                                          RSS-210 Annex A
                     Dwell time                        15.231 (a)(1)                                   Pass
                                                                          Section A.1.1 (a)
                                                                               RSS-GEN
                Frequency stability                          /                                         Pass
                                                                              Section 8.11
                                                                               RSS-GEN
               Conducted Emission                         15.207                                       N/A
                                                                               Section 8.8
    Remarks:
    N/A: The EUT not applicable of the test item.
    Pass: The EUT complies with the essential requirements in the standard.
    TEST ACCORDING TO ANSI C63.4:2014 AND ANSI C63.10:2013.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 4 of 33


c c I s                                                                       Report No: CCISE190503701v01

5         General Information
5.1 Client Information
            Applicant:                      Remote Tech LLC
            Address:                        310 ALDER RD, DOVER DE 19904 USA
            Manufacturer:                   Remote Tech LLC
            Address:                        310 ALDER RD, DOVER DE 19904 USA


5.2 General Description of E.U.T.
            Product Name:                   keyless transmitter
          Model No.:                        RT—HDOHYS, RT—HDOHY6
          Operation Frequency:              313.85MHz
          Channel numbers:                  1
          Modulation type:                  FSK
          Antenna Type:                     PCB antenna
          Antenna gain:                     0 dBi
            Power supply:                   DC 3V (CR2025 battery)
         Remark:                            Madel No.: RT—HDOHYS5, RT—HDOHY6 were identical inside, the
                                            electrical circuit design, layout, components used and internal wiring,
                                            with only difference being madel name.

5.3 Test mode
       Transmitting mode:              Keep the EUT in transmitting mode with modulation (new battery used)
    Pre—Test Mode:
    CCIS has verified the construction and function in typical operation, The EUT was placed on three different
    polar directions; .e. X axis, Y axis, Z axis. which was shown in this test report and defined as follows:
                Axis                            X                         Y                           Z
    Field Strength(dBuV/m)                  65.24                        64.59                      63.48
    Final Test Mode:
    According to ANSI C63.4 standards, the test results are both the "worst case" and "worst setup": X axis
    (see the test setup photo)


5.4 Description of Support Units
      N/A




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1905037
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                 Page 5 of 33


                                                                         Report No: CCISE190503701v01

5.5      Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        FCC - Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
        IC - Registration No.: 10106A-1
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.6 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com

5.7 Measurement Uncertainty
                    Parameters                                           Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                   ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                   ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                  ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                    ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                   ±2.88 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 6 of 33


                                                                              Report No: CCISE190503701v01

5.8 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date      Cal. Due date
   Test Equipment            Manufacturer             Model No.            Serial No.
                                                                                          (mm-dd-yy)       (mm-dd-yy)
       3m SAC                 SAEMC                   9m*6m*6m               966          07-22-2017       07-21-2020
  BiConiLog Antenna        SCHWARZBECK                VULB9163               497          03-18-2019       03-17-2020
    Horn Antenna           SCHWARZBECK               BBHA9120D               916          03-18-2019       03-17-2020
    Horn Antenna           SCHWARZBECK               BBHA9120D              1805          06-22-2017       06-21-2020
    Horn Antenna           SCHWARZBECK               BBHA 9170           BBHA9170582      11-21-2018       11-20-2019
    Loop Antenna           SCHWARZBECK              FMZB 1519 B              00044        03-18-2019       03-17-2020
  EMI Test Software            AUDIX                    E3                           Version: 6.110919b
    Pre-amplifier                HP                   8447D               2944A09358      03-18-2019       03-17-2020
    Pre-amplifier                CD                  PAP-1G18                11804        03-18-2019       03-17-2020
  Spectrum analyzer        Rohde & Schwarz            FSP30                 101454        03-18-2019       03-17-2020
  Spectrum analyzer        Rohde & Schwarz            FSP40                 100363        11-21-2018       11-20-2019
  EMI Test Receiver        Rohde & Schwarz            ESRP7                   101070      03-18-2019       03-17-2020
  Simulated Station            Anritsu               MT8820C               6201026545     03-18-2019       03-17-2020
       Cable                   ZDECL               Z108-NJ-NJ-81             1608458      03-18-2019       03-17-2020
       Cable                MICRO-COAX               MFR64639                K10742-5     03-18-2019       03-17-2020
       Cable                  SUHNER               SUCOFLEX100              58193/4PE     03-18-2019       03-17-2020
  DC Power Supply             XinNuoEr              WYK-10020K           1409050110020    10-31-2018       10-30-2019
    Temperature                                                                           09-24-2017       09-23-2018
                                HengPu               HPGDS-500           20140828008
  Humidity Chamber                                                                        09-24-2018       09-23-2019




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                  Page 7 of 33


                                                                         Report No: CCISE190503701v01

6      Test results and Measurement Data
6.1 Antenna requirement
        Standard requirement:          FCC Part15 C Section 15.203
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        E.U.T Antenna:
       The EUT make use of an PCB antenna, The typical gain of the antenna is 0 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 8 of 33


                                                                               Report No: CCISE190503701v01

6.2 Radiated Emission
                                        FCC Part15 C Section 15.231(b) and 15.209
        Test Requirement:
                                        RSS-210 Annex A Section A.1.2
        Test Method:                    ANSI C63.4:2014
        Test Frequency Range:           30MHz to 5000MHz
        Test site:                      Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                  Frequency         Detector           RBW         VBW           Remark
                                        30MHz-1GHz        Quasi-peak         120kHz      300kHz     Quasi-peak Value
                                        Above 1GHz          Peak              1MHz        3MHz        Peak Value
        Limit:                                 Frequency                 Limit (dBuV/m @3m)           Remark
        (Field strength of the                                                 75.55               Average Value
        fundamental signal)                    313.85MHz
                                                                                 95.55              Peak Value
        Limit:                                  Frequency                Limit (dBuV/m @3m)           Remark
        (Spurious Emissions)                  30MHz-88MHz                         40.0            Quasi-peak Value
                                             88MHz-216MHz                         43.5            Quasi-peak Value
                                            216MHz-960MHz                         46.0            Quasi-peak Value
                                              960MHz-1GHz                         54.0            Quasi-peak Value
                                                                                  54.0             Average Value
                                              Above 1GHz
                                                                                  74.0              Peak Value
                                        Or The maximum permitted unwanted emission level is 20 dB below the
                                         maximum permitted fundamental level whichever limit permits higher field
                                         strength.
        Test Procedure:                 a. The EUT was placed on the top of a rotating table 0.8m(below 1GHz)
                                             /1.5m(above 1GHz) above the ground at a 3 meter chamber. The
                                             table was rotated 360 degrees to determine the position of the highest
                                             radiation.
                                        b. The EUT was set 3 meters away from the interference-receiving
                                             antenna, which was mounted on the top of a variable-height antenna
                                             tower.
                                        c. The antenna height is varied from one meter to four meters above the
                                             ground to determine the maximum value of the field strength. Both
                                             horizontal and vertical polarizations of the antenna are set to make
                                             the measurement.
                                        d. For each suspected emission, the EUT was arranged to its worst case
                                             and then the antenna was tuned to heights from 1 meter to 4 meters
                                             and the rotatable table was turned from 0 degrees to 360 degrees to
                                             find the maximum reading.
                                        e. The test-receiver system was set to Peak Detect Function and
                                             Specified Bandwidth with Maximum Hold Mode.
                                        f. If the emission level of the EUT in peak mode was 10dB lower than
                                             the limit specified, then testing could be stopped and the peak values
                                             of the EUT would be reported. Otherwise the emissions that did not
                                             have 10dB margin would be re-tested one by one using peak, quasi-
                                             peak or average method as specified and then reported in a data
                                             sheet.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 9 of 33


                                                                           Report No: CCISE190503701v01

        Test setup:                     Below 1GHz




                                        Above 1GHz




        Test Instruments:               Refer to section 5.7 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 10 of 33


                                                                                 Report No: CCISE190503701v01

6.2.1    Field Strength Of The Fundamental Signal
                                                       Peak value
                 Read       Antenna        Cable                                                Over
Frequency                                               Preamp         Level       Limit Line
                 Level       Factor        Loss                                                 Limit     Polarization
  (MHz)                                                Factor(dB)    (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)         (dB)                                                (dB)
  313.85         40.25        13.90         2.98          0.00           57.13       95.55      -38.42      Vertical
  313.85         48.36        13.90         2.98          0.00           65.24       95.55      -30.31    Horizontoal
                                                     Average value
                 Read       Antenna        Cable                                                Over
Frequency                                  Loss         Preamp         Level       Limit Line
                 Level       Factor                                                             Limit     Polarization
  (MHz)                                                Factor(dB)    (dBuV/m)      (dBuV/m)
                (dBuV)       (dB/m)         (dB)                                                (dB)
  313.85         37.45        13.90         2.98          0.00           54.33       75.55      -21.22      Vertical
  313.85         44.10        13.90         2.98          0.00           60.98       75.55      -14.57    Horizontoal
Remark: Duty cycle =100%




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 11 of 33


CCGIS                                                                            Report No: CCISE190503701v01

Test Plots:
Product Name:               Keyless transmitter                        Product Model:               RT—HDOHYS

Test By:                   Carey                                       Test mode:                   Tx mode

Test Frequency:            313.85 MHz                                  Polarization:                Vertical

Test Voltage:               DC 3V                                      Environment:                 Temp: 24°C      Huni: 57%

     110Level (dBuV/im)


     100



      80



      60                                                   4



      40



      20




       0312        312.5                                                                      315                       316
                                                      Frequency (MHz)
                             Read&ntenna          Cable Preamp                    Limit             Over
                   Freq     Level Factor            Loss Factor          Level         Line     Limit Remark

           """MHz           dBu¥ dB/m — dB _dB dBu¥/m dBu¥/m                                         dB
       1       313.826      40.25      13.90       2. 98       D.N0      §17. 13.—«ecccoucuic~ Peak
       2       313.826      ~37.45     13.90       2. 98       0.00:     54. 33. —rco—siiccares— bverage


Remark:
1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampilifier Factor.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1905037
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                           Page 12 of 33


CCIS                                                                           Report No: CCISE190503701v01



Product Name:              Keyless transmitter                      Product Model:              RT—HDOHYS

Test By:                   Carey                                    Test mode:                  Tx mode

Test Frequency:            313.85 MHz                               Polarization:               Horizontal

Test Voltage:              DC 3V                                    Environment:                Temp: 24°C      Huni: 57%

    110 Level (dBuVim}

    100



     80
                                                            4
     60



     40



     20




       G312        312.5                                                                  315                       316
                                                      Frequency (MHz)

                            Readinterna          Cable Preamp                    Limit       Over
                 Freq      Level Factor            Loss Factor        Level        Line     Linit Remark

           """MHz           dBu¥ dEB/m — dB _ dB dBu¥/m dBu¥/m dB
      1       313.930      48.36      13.90       2.08.     N.N0.     pC, Rft—weccomerituuce Peak
      2       313.930      44.10      13.90       2. 98     D:OM:     ‘60.98i—r—=—zicce—<— bverage


Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1905037
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Baoc‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 13 of 33


CCIS                                                                              Report No: CCISE190503701v01

6.2.2          Spurious Emissions

Test Plots:
Product Name:                Keyless transmitter                   Product Model:             RT—HDOHYS
Test By:                     Carey                                 Test mode:                 Tx mode
Test Frequency:              30 MHz ~ 1 GHz                        Polarization:              Vertical
Test Voltage:                DC 3V                                 Environment:               Temp: 24°C           Huni: 57%


   110 Level (dBuVim)

   100


     80
                                                         Fundamental signal
     60
                                                                                              FCC PART1S CLASS B
                                                                                                         7            £




          30            50                  100                 200                           500                    1000
                                                      Frequency (MHz)

                                Readintenna        Cable Preamp                    Limit       Over
                      Freq     Level Factor         Loss Factor          Level       Line     Linit Remark

                ______NHz      dBu¥ dB/m             dB _dB dBu¥/m dBu¥/m —                              dB
        1          145.695     16.79    12.28       1. 29      0.00      30.36     40.00 —8.64               QP
        2          95.113      17.91    10.87       2. 02      0.00.     30.80     43.50—12.7TO              —GP
        3         121. 123     .38      10.81       2. 18      8.00.     ©30.37    43.50 —<13.13             9P
        4         192.419      15.21    10.38       2. 82      0.00      28.41     43.50 —15.09              9P
        5         629.477      20.69    19.63       3. 89      0.00      44.21     46.00 —1.79               QP
        6         942. 131     17.14    22.61       4.13       0.00      43.94     46.00 —2.06               qP


Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1905037
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 14 of 33


CCIS                                                                                Report No: CCISE190503701v01


Product Name:                 Keyless transmitter                     Product Model:            RT—HDOHYS
Test By:                      Carey                                   Test mode:                Tx mode

Test Frequency:               30 MHz ~ 1 GHz                          Polarization:             Horizontal

Test Voltage:                 DC 3V                                   Environment:              Temp: 24°C     Huni: 57%

        110 Level (dBuVim)

        100


          80                                                   Fundamental signal



          60                                                                                      FCC PART1S CLASS B
                                                                                                                  a
                                                                                                            DWM
         40


          20



               30          50                   100                 200                           500             1000
                                                          Frequency (MHz)

                                 Read&ntenna          Cable Preamp                   Limit       Over
                       Freq     Level Factor           Loss Factor        Level         Line    Linit Remark

               ______NHz        dBu¥ dB/m _dB _dB dBu¥/m dBu¥/m                                    dB %
        1            44.901     17.35    12.30         1,28      0.00     30.93      40.00 —8.07 QP
        2            92.462     17.25    10.65         2. 03     0.00     29.93      43.50 —13.57 QP
        3           120.699     18.35    10.85         2.18°     0.00     31.38      43.50 —12.12 gP
        4           490.745     17.42    17. 86        3.54       0.00    38.82      46.00 —7.18 QP
        5           627.274     17.57    19.62         3. 90     0.00     41.09      46.00 —4.91 QP
        a           $42.131     18.35    32.67         4.13      0.00     45.15      46.00 —0.85 qP


Remark:
 1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
2.    The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                   Project No.: CCISE1905037
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                      Page 15 of 33


c c I s                                                                           Report No: CCISE190503701v01



Product Name:               Keyless transmitter                    Product Model:             RT—HDOHYS

Test By:                    Carey                                  Test mode:                 Tx mode
Test Frequency:             1 GHz ~5 GHz                           Polarization:              Vertical

Test Voltage:               DC 3V                                  Environment:               Temp: 24°C      Huni: 57%

    8o Level (dBuV/im)
                                                                                                 FCC PART 15 (PK)
    70


    60
                                                                                                 FCC PART 15 (AV)
    50                                                               5       6
                        1               2         3          T       |              7
    40

    SUW


    20


    10


     G‘IOOG      1200            1500                 2000                                                     5000
                                                       Frequency (MHz)
   Remark            : 313,.95
                         Readintenna            Cable     bux Preamp                     Limit      Over
                  Freq Level Factor               Loss Factor Factor             Level    Line     Linmit Remark

           ______NHz        dBu¥ dB/m — dB — dB _ dB dBuV/m dBuV/m                                       dB
      1       1254.743      52.98       24.66     3. 40     1.23    41.05        41.22   74.00   —32.78    PFeak
      2       1589. 657     53.20       25.37     3.83      1.39    41.03        42.85   74.00   —31.15    Peak
      3       1882. 328     52.07       25.68     4.21      1.55    41.40        42.11   74.00   —31.89    Peak
      4       2196. 829     52.69       26.47     4.50      1.64    41.68        43.62   74.00   —30.38    Peak
      5       2510.793      53.72       27.43     4.M       1.70    41.90        45.79   74.00   —28.21    Peak
      6       2C23.E11      —61,93      28.17     5.10      1.83    41.64        45.41   74.00   —28.59    Peak
      T       3140.275      46.26       28.53     5.40      1.88    41.44        40.73   74.00   —33.27    Peak


Remark:
1. Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1905037
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 16 of 33


c c I s                                                                           Report No: CCISE190503701v01


Product Name:                  Keyless transmitter                   Product Model:             RT—HDOHYS
Test By:                       Carey                                 Test mode:                Tx mode
Test Frequency:                1 GHz ~ 5 GHz                         Polarization:              Horizontal

Test Voltage:                  DC 3V                                 Environment:              Temp: 24°C        Huni: 57%

      so Level (dBuV/im)
                                                                                                    FCC PART 15 (PK)
      70

      60
                                                                                                    FCC PART 15 (AV)
      50                                                               5

      40


      30

      20

      10


       01000       1200             1500               2000                                                       5000
                                                        Frequency (MHz)
     Remark               :0
                        313. 85
                          Readintenna               Cable    Aux Preamp                    Limit       Over
                   Freq Level Factor                 Loss Factor Factor          Level       Line     Linit Remark

           """MHz              dBu¥ dB/m — dB — dB _ dB dBuV/m dBuV/m                                      dB
       1      1254.743         55.18       24.66     3. 40   1.23     41.05      43.42     74.00    —30.58    Peak
       2      1§69. 320        54.04       25.31     3. 81   1,.39    41.03      43.52     74.00    —30.48    Peak
       3      1882. 328         52.84      25.68     4.21    1,.55    41.40      42.88     74.00    —31.12    Peak
       4      2196.828         51.02       26.417    4.50    1.64     41.68      41.95     74.00    —32.05    Feak
       5      2498.699         55.49       27.40     4.82    1.70     41.90      47.51     74.00    —26.49    Peak
       6      2C23.S11         —b5b.63     28.13     5. 16   1.83     41.64      49.11     74.00    —24.89    Feak
       T      3140.275         47.96       28.53     5.40    1.98     41.44      42.43     74.00    —31.57    Peak


Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                   Project No.: CCISE1905037
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 17 of 33


                                                                            Report No: CCISE190503701v01

6.3 20dB Bandwidth
        Test Requirement:                FCC Part15 C Section 15.231 (c)
                                         RSS-210 Annex A Section A.1.3
        Test Method:                     ANSI C63.4:2014
        Receiver setup:                  RBW=1kHz, VBW=3kHz, detector: Peak
        Limit:                           The bandwidth of the emission shall be no wider than 0.25% of the center
                                         frequency for devices operating above 70 MHz and below 900 MHz. For
                                         devices operating above 900 MHz, the emission shall be no wider than
                                         0.5% of the center frequency. Bandwidth is determined at the points 20
                                         dB down from the modulated carrier.
        Test Procedure:                  1. According to the follow Test-setup, keep the relative position between
                                            the artificial antenna and the EUT.
                                         2. Set the EUT to proper test channel.
                                         3. Max hold the radiated emissions, mark the peak power frequency
                                            point and the -20dB upper and lower frequency points.
                                         4. Read 20dB bandwidth.
        Test setup:




        Test Instruments:                Refer to section 5.7 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data
  20dB bandwidth (MHz)            99% Occupy Bandwidth (MHz)                  Limit (MHz)             Results
            0.151                                0.212                          0.7846                Passed

Note: Limit= Fundamental frequency×0.25%=313.85×0.25%=0.7846MHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 18 of 33


                                                                                                       Report No: CCISE190503701v01

Test plot as follows:
                                                                   20dB Bandwidth
                                                                          * RBW   1 kHz        Delta 1 [T1 ]
                                                                          * VBW   3 kHz                   -0.97 dB
                           Ref    11 dBm              * Att   20 dB        SWT 500 ms             151.000000000 kHz

                           10    Offset    1 dB                                                Marker 1 [T1 ]
                                                                                                         -48.16 dBm
                                                                                                  313.802000000 MHz    A
                           0

                    1 PK
                    MAXH
                           -10                                                                                        LVL




                           -20

                                    D1 -26.3 dBm
                           -30

                                                                                                                      75

                           -40

                                          D2 -46.3 dBm
                                                               1                           1                          3DB

                           -50



                           -60



                           -70



                           -80




                           Center 313.85 MHz                          50 kHz/                          Span 500 kHz




                    Date: 17.MAY.2019             15:44:09




                                                          99% Occupy Bandwidth
                                                                          * RBW   3 kHz        Marker 1 [T1 ]
                                                                          * VBW   10 kHz                 -25.26 dBm
                           Ref -9 dBm                 * Att   0 dB         SWT 60 ms              313.825000000 MHz

                           -10 Offset      1 dB                                                OBW212.000000000 kHz
                                                                                               Temp 1 [T1 OBW]
                                                                                                         -52.02 dBm    A
                           -20
                                                                     1                            313.770000000 MHz
                    1 PK
                                                                                               Temp 2 [T1 OBW]
                    MAXH
                           -30                                                                           -51.70 dBm LVL
                                                                                                  313.982000000 MHz


                           -40



                                                         T1                                       T2
                           -50



                           -60

                                                                                                                      3DB

                           -70



                           -80



                           -90



                           -100




                           Center 313.85 MHz                          50 kHz/                          Span 500 kHz




                    Date: 3.JUN.2019           17:36:11




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                          Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                             Page 19 of 33


                                                                            Report No: CCISE190503701v01

6.4 Duration Time
                                         FCC Part15 C Section 15.231 (a)(1)
        Test Requirement:
                                         RSS-210 Annex A Section A.1.1 (a)
        Test Method:                     ANSI C63.10: 2013
        Receiver setup:                  RBW=100kHz, VBW=300kHz, span=0Hz, detector: Peak
        Limit:                           Not more than 5 seconds
        Test mode:                       Transmitting mode
        Test Procedure:                  1. According to the follow Test-setup, keep the relative position between
                                            the artificial antenna and the EUT.
                                         2. Set the EUT to proper test channel.
                                         3. Single scan the transmission, and read the transmission time.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data
         Duration time (second)                        Limit (second)                        Result
                  0.28                                     <5.0                               Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 20 of 33


                                                                                               Report No: CCISE190503701v01

Test plot as follows:
                                                                         RBW 1 MHz      Delta 2 [T1 ]
                                                                        * VBW   1 MHz              -0.28 dB
                           Ref    11 dBm              * Att   20 dB      SWT 10 s               5.000000 s

                           10    Offset    1 dB                                         Marker 1 [T1 ]
                                                                                                  -61.02 dBm
                                                                                              300.000000 ms     A
                           0
                                                                                                               SGL
                                                                                        Delta 1 [T1 ]
                    1 PK
                                                                                                   -0.92 dB
                    MAXH
                           -10                                                                280.000000 ms    LVL




                           -20



                           -30

                                                                                                               75

                           -40

                                                                                                               3DB

                           -50


                            1 1                                         2
                           -60



                           -70



                           -80




                           Center 313.85 MHz                          1 s/




                    Date: 17.MAY.2019             15:46:03




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                   Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                      Page 21 of 33


                                                                              Report No: CCISE190503701v01

6.5 Frequency stability
       Test Requirement:                   RSS-GEN Section 8.11
       Test Method:                        RSS-GEN Section 6.11
       Limit:                              kept within at least the central 80% of its permitted operating frequency
                                           band.
       Test setup:




       Test procedure:                     1.   The EUT is installed in an environment test chamber with external
                                                power source.
                                           2.   Set the chamber to operate at 50 centigrade and external power
                                                source to output at nominal voltage of EUT.
                                           3.   A sufficient stabilization period at each temperature is used prior to
                                                each frequency measurement.
                                           4.   When temperature is stabled, measure the frequency stability.
                                           5.   The test shall be performed under -20 to 50 centigrade and 85 to
                                                115 percent of the nominal voltage. Change setting of chamber
                                                and external power source to complete all conditions.
       Test Instruments:                   Refer to section 5.7 for details
       Test mode:                          Refer to section 5.3 for details
       Test results:                       Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1905037
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 22 of 33


CCIS                                                                                      Report No: CCISE190503701v01

Measurement Data (worst case):
Voltage vs. Freque ncy Stability
             Test conditions
       Temp(C)            Voitage(de)                       Measurement Frequency (MHz)                            Limit (MHz)

                                    s2V                                      313.922
           20                       8.0Vv                                    313.928                               281 ~ 449
                                    2.5V                                     313.923
  Note: EUT stops working when the supply voltage is lower than DC 2.5V.


Temperature vs. Frequency Stability
                Test conditions
      V         de              T         C
                                                                          Frequency(MHz)                           Limit (MHz)
                                    —20                                      313.925
                                    —10                                      313.922
                                     0                                       313.923
                                     10                                      313.924
                                                                                                                   281 ~ 449
                                     20                                      313.923
                                     30                                      313.925
                                     40                                      313.926
                                                                             313.924
Test plot as follows :
                                                                     «haw n ue     marker i (rild
                                                                     «vew n ue               —z6.«1 can
                                                 wars    20 ae        sur seo me      212.022000000 imz




                          mns                                                                             m




                          "                                  on


                         cancer si2.05 muz                       so knz                    span 00 knz




                     Date: 17.MAY.2019        15:43:02




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                              Project No.: CCISE1905037
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                 Page 23 of 33