Test Report

FCC ID: 2AOKM-FD4

Test Report

Download: PDF
FCCID_4037073

                       Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                       Report No: CCISE180904401

1         Cover Page

                        FCC/IC REPORT
    Applicant:                          Remote Tech LLC

    Address of Applicant:               310 ALDER RD, DOVER DE 19904 USA

    Equipment Under Test (EUT)

     Product Name:                      keyless transmitter
     Model No.:                         RT-FD4-3B, RT-FD4-4B

    FCC ID:                             2AOKM-FD4

    IC:                                 24223-FD4

    Applicable standards:               FCC CFR Title 47 Part 15 Subpart C,15.231
                                        RSS-Gen Issue 5 April 2018
                                        RSS-210 Issue 9 August 2016,Annex A
    Date of sample receipt:             12 Sep., 2018
    Date of Test:                       12 Sep., to 29 Sep., 2018
    Date of report issue:               29 Sep., 2018
    Test Result:                        PASS*

*    In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




        Bruce Zhang
     Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                 Report No: CCISE180904401


2      Version
     Version No.                         Date                                    Description
            00                     29 Sep., 2018                                   Original




    Prepared By:                                                         Date:          29 Sep., 2018

                                       Test Engineer

    Check By:                                                            Date:          29 Sep., 2018

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 2 of 33


                                                                                                                           Report No: CCISE180904401

3         Contents
                                                                                                                                                                               Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST MODE ............................................................................................................................................................ 5
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 5
    5.5         LABORATORY FACILITY.......................................................................................................................................... 6
    5.6         LABORATORY LOCATION ....................................................................................................................................... 6
    5.7         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1     ANTENNA REQUIREMENT ....................................................................................................................................... 8
    6.2     RADIATED EMISSION ............................................................................................................................................. 9
       6.2.1 Field Strength Of The Fundamental Signal .............................................................................................. 11
       6.2.2 Spurious Emissions ..................................................................................................................................... 15
    6.3     20DB BANDWIDTH ............................................................................................................................................... 20
    6.4     DURATION TIME ................................................................................................................................................... 22
    6.5     FREQUENCY STABILITY ....................................................................................................................................... 24
7       TEST SETUP PHOTOS...................................................................................................................................... 26
8       EUT CONSTRUCTIONAL PHOTOS ................................................................................................................. 27




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                          Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                        Page 3 of 33


CCIS                                                                                 Report No : CCISE180904401

4      Test Summary

                                                                    Section in CFR 47
                       Test Item                                                                           Result
                                                              FCC                      IC
                Antenna requirement                          15.203             RSS—GEN 6.8                 Pass

       i
      Field                              ;
            strength of the fundamental signal             15.231 (b)          RSS—210   Annex(a)A
                                                                                Section A.1.2               Pass

                      i      isei                                              RSS—210   Annex A
                 Spurious emissions                    15.231 (b)/15.209        Section A.1.2 (b)           Pass

                                .                                               RSS—210 A.1.3
             20dB and 99% Bandwidth                        15.231 (c)            RSS—GEN 6.7                Pass

                           fon   ti                                          RSS—210 Annex A
                     Duration time                         15231 (@1)          gection A1.1 (a)             Pass
                  Frequency stability                           /               RSS—GEN 8.11                Pass


                 Conducted Emission                          15.207              RSS—GEN 8.8                 N/A

     Remarks:
     N/A: The EUT not applicable of the test item.
     Pass: The EUT complies with the essential requirements in the standard.
     TEST ACCORDING TO ANSI €63.4:2014 AND ANSI C63.10:2013.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1809044
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 4 of 33


c c I s                                                                               Report No: CCISE180904401

5       General Information
5.1 Client Information
         Applicant:                         Remote Tech LLC
         Address of Applicant:              310 ALDER RD, DOVER DE 19904 USA
         Manufacturer:                      Remote Tech LLC
         Address of Manufacturer:           310 ALDER RD, DOVER DE 19904 USA

5.2 General Description of E.U.T.
         Product Name:                      keyless transmitter
         Model No.:                         RT—FD4—3B, RT—FD4—4B
         Operation Frequency:               315MHz
         Channel numbers:                   1
         Modulation type:                   ASK
         Antenna Type:                      PCB antenna
         Antenna gain:                      0 dBi
         Power supply:                      DC 3V (CR2032 battery)
        Remark:                             Model RT—FD4—3B, RT—FD4—4B are electrically identical, only except RT—FD4—38 have
                                            3 buttons and RT—FD4—48 have 4 buttons


 5.3 Test mode
        Transmitting mode:               Keep the EUT in transmitting mode with modulation (new battery used)
        Remark:                          Unmodulated carrier is not available, test at modulated carrier mode.

    Pre—Test Mode:
    CCIS has verified the construction and function in typical operation, The EUT was placed on three different
    polar directions; .e. X axis, Y axis, Z axis. which was shown in this test report and defined as follows:
               Axis                              X                              Y                               Z
     Field Strength(dBuV/m)                     70.54                        69.78                           67.82
    Final Test Mode:
    According to ANSI C63.4 standards, the test results are both the "worst case" and "worst setup": X axis
    (see the test setup photo)


 5.4 Description of Support Units
      N/A




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1809044
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                        Page 5 of 33


                                                                            Report No: CCISE180904401

5.5      Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        FCC - Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
        IC - Registration No.: 10106A-1
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.6 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com

5.7 Measurement Uncertainty
                    Parameters                                           Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                   ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                   ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                  ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                    ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                   ±2.88 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 6 of 33


                                                                                     Report No: CCISE180904401

5.8 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date      Cal. Due date
   Test Equipment            Manufacturer             Model No.            Serial No.
                                                                                          (mm-dd-yy)       (mm-dd-yy)
      3m SAC                   SAEMC                  9m*6m*6m               966          07-22-2017       07-21-2020
  BiConiLog Antenna         SCHWARZBECK               VULB9163               497          03-16-2018       03-15-2019
    Horn Antenna            SCHWARZBECK              BBHA9120D               916          03-16-2018       03-15-2019
    Horn Antenna            SCHWARZBECK              BBHA9120D              1805          06-22-2017       06-21-2020
    Horn Antenna            SCHWARZBECK              BBHA 9170           BBHA9170582      11-21-2017       11-20-2018
    Loop Antenna            SCHWARZBECK              FMZB 1519 B             00044       04-28-2018        04-27-2019
  EMI Test Software             AUDIX                    E3                          Version: 6.110919b
     Pre-amplifier                HP                   8447D              2944A09358     03-07-2018        03-06-2019
     Pre-amplifier                CD                  PAP-1G18               11804       03-07-2018        03-06-2019
  Spectrum analyzer         Rohde & Schwarz            FSP30                101454       03-07-2018        03-06-2019
  Spectrum analyzer         Rohde & Schwarz            FSP40                100363       11-21-2017        11-20-2018
   EMI Test Receiver        Rohde & Schwarz            ESRP7                  101070      03-07-2018       03-06-2019
   Simulated Station            Anritsu               MT8820C              6201026545     03-07-2018       03-06-2019
        Cable                   ZDECL               Z108-NJ-NJ-81            1608458      03-07-2018       03-06-2019
        Cable                MICRO-COAX               MFR64639               K10742-5     03-07-2018       03-06-2019
        Cable                  SUHNER               SUCOFLEX100             58193/4PE     03-07-2018       03-06-2019
   DC Power Supply             XinNuoEr              WYK-10020K          1409050110020    10-31-2017       10-30-2018
     Temperature                                                                          09-24-2017       09-23-2018
                                HengPu               HPGDS-500            20140828008
   Humidity Chamber                                                                       09-24-2018       09-23-2019




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                 Page 7 of 33


                                                                           Report No: CCISE180904401

6      Test results and Measurement Data
6.1 Antenna requirement
        Standard requirement:          FCC Part15 C Section 15.203
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        E.U.T Antenna:
       The EUT make use of an PCB antenna, The typical gain of the antenna is 0 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 8 of 33


                                                                                   Report No: CCISE180904401

6.2 Radiated Emission
                                        FCC Part15 C Section 15.231 (b)/15.209
        Test Requirement:
                                        RSS-210 Annex A Section A.1.2 (b)
        Test Method:                    ANSI C63.10:2013
        Test Frequency Range:           30MHz to 3500MHz
        Test site:                      Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                  Frequency         Detector           RBW         VBW           Remark
                                        30MHz-1GHz        Quasi-peak         120kHz      300kHz     Quasi-peak Value
                                        Above 1GHz          Peak              1MHz        3MHz        Peak Value
        Limit:                                 Frequency                 Limit (dBuV/m @3m)           Remark
        (Field strength of the                                                 75.62               Average Value
        fundamental signal)                     315MHz
                                                                                 95.62              Peak Value
        Limit:                                  Frequency                Limit (dBuV/m @3m)           Remark
        (Spurious Emissions)                  30MHz-88MHz                         40.0            Quasi-peak Value
                                             88MHz-216MHz                         43.5            Quasi-peak Value
                                            216MHz-960MHz                         46.0            Quasi-peak Value
                                              960MHz-1GHz                         54.0            Quasi-peak Value
                                                                                  54.0             Average Value
                                              Above 1GHz
                                                                                  74.0              Peak Value
                                        Or The maximum permitted unwanted emission level is 20 dB below the
                                         maximum permitted fundamental level whichever limit permits higher field
                                         strength.
        Test Procedure:                 a. The EUT was placed on the top of a rotating table 0.8m(below 1GHz)
                                             /1.5m(above 1GHz) above the ground at a 3 meter chamber. The
                                             table was rotated 360 degrees to determine the position of the highest
                                             radiation.
                                        b. The EUT was set 3 meters away from the interference-receiving
                                             antenna, which was mounted on the top of a variable-height antenna
                                             tower.
                                        c. The antenna height is varied from one meter to four meters above the
                                             ground to determine the maximum value of the field strength. Both
                                             horizontal and vertical polarizations of the antenna are set to make
                                             the measurement.
                                        d. For each suspected emission, the EUT was arranged to its worst case
                                             and then the antenna was tuned to heights from 1 meter to 4 meters
                                             and the rotatable table was turned from 0 degrees to 360 degrees to
                                             find the maximum reading.
                                        e. The test-receiver system was set to Peak Detect Function and
                                             Specified Bandwidth with Maximum Hold Mode.
                                        f. If the emission level of the EUT in peak mode was 10dB lower than
                                             the limit specified, then testing could be stopped and the peak values
                                             of the EUT would be reported. Otherwise the emissions that did not
                                             have 10dB margin would be re-tested one by one using peak, quasi-
                                             peak or average method as specified and then reported in a data
                                             sheet.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 9 of 33


                                                                           Report No: CCISE180904401

        Test setup:                     Below 1GHz




                                        Above 1GHz




        Test Instruments:               Refer to section 5.7 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                   Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                      Page 10 of 33


                                                                                     Report No: CCISE180904401

6.2.1    Field Strength Of The Fundamental Signal
                                                       Peak value
                 Read          Antenna      Cable                                                      Over
Frequency                                               Preamp             Level      Limit Line
                 Level          Factor      Loss                                                       Limit     Polarization
  (MHz)                                                Factor(dB)        (dBuV/m)     (dBuV/m)
                (dBuV)          (dB/m)       (dB)                                                      (dB)
   315           44.77          13.92       2.99          0.00            61.68           95.60        -33.92       Vertical
   315           53.63          13.92       2.99          0.00            70.54           95.60        -25.06     Horizontoal
                                                      Average value
Frequency               Level            Duty Cycle    Average value         Limit Line           Over Limit
                                                                                                                 Polarization
  (MHz)               (dBuV/m)             factor        (dBuV/m)            (dBuV/m)               (dB)
   315                 61.68               -11.97           49.71                 75.60            -25.89          Vertical
   315                 70.54               -11.97           58.57                 75.60            -17.03        Horizontal
                                 Average value=Peak value + Duty Cycle Factor
   Calculate Formula:            Duty cycle factor = 20log(Duty cycle)
                                 Duty cycle = on time/100 milliseconds or period, whichever is less
                                 T on time =(25*0.54)(ms) +(39*0.30) (ms) =25.20(ms)
                                 T period =[(354-48.6X4)/3]+48.6=101.8ms>100ms
         Test data:
                                 Duty cycle =25.20%
                                 Duty cycle factor = 20log(Duty cycle) = -11.97




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 11 of 33


                                                                                                                                            Report No: CCISE180904401


                                                      T period:                                                                                       T 100ms:
                                                             RBW 1 MHz      Delta 1 [T1 ]                                                                     RBW 1 MHz        Delta 1 [T1 ]
                                                            * VBW   1 MHz              -0.04 dB                                                              * VBW     1 MHz              -0.72 dB
            Ref       6.5 dBm            * Att   10 dB       SWT 1 s              354.000000 ms                   Ref    6.5 dBm          * Att   10 dB       SWT 100 ms              48.600000 ms

                  Offset    6.5 dB                                          Marker 1 [T1 ]                              Offset   6.5 dB                                        Marker 1 [T1 ]

            0                                                                         -68.78 dBm                  0                                                                      -69.78 dBm
                                                                                   48.000000 ms    A                                                                                   7.800000 ms    A
                                                                                                   SGL                                                                                                SGL
   1 PK *   -10                                                                                          1 PK *   -10
   CLRWR                                                                                                 CLRWR
                                                                                                   LVL                                                                                                LVL

            -20                                                                                                   -20



            -30                                                                                                   -30



            -40                                                                                                   -40



            -50                                                                                    3DB            -50                                                                                 3DB




            -60                                                                                                   -60

                  1                               1
                                                                                                                         1                                         1
            -70                                                                                                   -70



            -80                                                                                                   -80



            -90                                                                                                   -90

            Center 315 MHz                               100 ms/                                                  Center 315 MHz                          10 ms/




   Date: 15.SEP.2018            09:20:22                                                                 Date: 15.SEP.2018           09:21:36




                                                         T 53ms:                                                                             T on time slot-1:
                                                             RBW 1 MHz                                                                                        RBW 1 MHz        Delta 1 [T1 ]
                                                            * VBW   1 MHz                                                                                    * VBW     1 MHz              -1.88 dB
            Ref       6.5 dBm            * Att   10 dB       SWT 53 ms                                            Ref    6.5 dBm          * Att   10 dB       SWT 10 ms              540.000000 µs

                  Offset    6.5 dB                                                                                      Offset   6.5 dB                                        Marker 1 [T1 ]

            0                                                                                                     0                                                                      -71.82 dBm
                                                                                                   A                                                                                   3.980000 ms    A
                                                                                                   SGL                                                                                                SGL
   1 PK *   -10                                                                                          1 PK *   -10
   CLRWR                                                                                                 CLRWR
                                                                                                   LVL                                                                                                LVL

            -20                                                                                                   -20



            -30                                                                                                   -30



            -40                                                                                                   -40



            -50                                                                                    3DB            -50                                                                                 3DB




            -60                                                                                                   -60



                                                                                                                                                  1
            -70                                                                                                   -70                                 1



            -80                                                                                                   -80



            -90                                                                                                   -90

            Center 315 MHz                               5.3 ms/                                                  Center 315 MHz                          1 ms/




   Date: 15.SEP.2018            09:22:26                                                                 Date: 15.SEP.2018           09:25:00




                                             T on time slot-2:
                                                             RBW 1 MHz      Delta 1 [T1 ]
                                                            * VBW   1 MHz              -1.24 dB
            Ref       6.5 dBm            * Att   10 dB       SWT 10 ms            300.000000 µs

                  Offset    6.5 dB                                          Marker 1 [T1 ]

            0                                                                         -70.55 dBm
                                                                                    2.720000 ms    A
                                                                                                   SGL
   1 PK *   -10
   CLRWR
                                                                                                   LVL

            -20



            -30



            -40



            -50                                                                                    3DB




            -60


                                     1
                                         1
            -70



            -80



            -90

            Center 315 MHz                                1 ms/




   Date: 15.SEP.2018            09:25:36




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                               Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                                       Page 12 of 33


CCIS                                                                                 Report No: CCISE180904401

Test Plots:
Product Name:                 keyless transmitter                   Product Model:           RT—FD4—3B

Test By:                      Zora                                  Test mode:               Tx mode

Test Frequency:               315 MHz                               Polarization:            Vertical

Test Voltage:                 DC 3V                                 Environment:             Temp: 24°C     Huni: 57%

        120Level (dBu\Vim)

        110



         90



         70                                                     4

         50



         30


         10

              314     314.2           314.5                   315                                                 316
                                                        Frequency (MHz)

                            Readéntenna       Cable     Aux Preamp                  Limit     Over
                    Freq   Level Factor         Loss Factor Factor        Level      Line    Limit Remark

                    NHz       dBu¥    dB/m                          dB dBu¥/m dBu¥/n             dB
    1         315.012      44.77      13.92     2.99            0:00      Bl;M§w—mca— =munas



Remark:
1. _Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1809044
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 13 of 33


c c I s                                                                            Report No: CCISE180904401


Product Name:              keyless transmitter                    Product Model:              RT—FD4—3B

Test By:                   Zora                                   Test mode:                  Tx mode

Test Frequency:            315 MHz                                Polarization:               Horizontal

Test Voltage:              DC 3V                                  Environment:                Temp: 24°C   Huni: 57%


     120I_evel (dBuVim)

     110


      90


      70


      50


      30




          G314     314.2           314.5                      315                                                316
                                                        Frequency (MHz)

                            Readintenna      Cable     Aux Preamp                   Linit        Over
                   Freq    Level Factor        Loss Factor Factor         Level       Line      Limit Remark

                     NHz    dBu¥      dB/m         dB       dB       dB dBu¥/m dBu¥/m               dB ~
      1          315.008   §3.63     13.92       2.99    0.00     0.00     70. §4 —————— ——————



Remark:
1.   Final Level = Receiver Read level + Anienna Factor + Cable Loss — Preamplifier Factor.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1809044
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                  Page 14 of 33


                                                                              Report No: CCISE180904401

6.2.2    Spurious Emissions
                                           Below 1GHz (30MHz-1000MHz)
                                                         Peak value
                 Read        Antenna      Cable       Preamp
Frequency                                                         Level    Limit Line       Over Limit
                 Level        Factor      Loss         Factor                                              polarization
  (MHz)                                                         (dBuV/m)   (dBuV/m)           (dB)
               (dBuV/m)       (dB/m)       (dB)         (dB)
  631.688        22.79         19.59      3.89          0.00      46.27      75.62            -29.35         Vertical
  945.440        26.75           22.39     4.16        0.00       53.30      75.62            -22.32         Vertical
  631.688        27.01           19.59     3.89        0.00       50.49      75.62            -25.13       Horizontal
  945.440        33.44           22.39     4.16        0.00       59.99      75.62            -15.63       Horizontal
                                                      Average value
  Frequency             Level            Duty cycle       Average value    Limit Line       Over Limit
                                                                                                          Polarization
    (MHz)             (dBuV/m)             factor           (dBuV/m)       (dBuV/m)           (dB)
    631.688              46.27             -11.97              34.30         55.62            -21.32         Vertical
    945.440              53.30             -11.97              41.33         55.62            -14.29         Vertical
    631.688              50.49             -11.97              38.52         55.62            -17.10       Horizontoal
    945.440              59.99             -11.97              48.02         55.62             -7.60       Horizontoal
Remark: Average value=Peak value + Duty Cycle Factor.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 15 of 33


CCIS                                                                                         Report No: CCISE180904401

Test Plots:
Product Name:                    keyless transmitter                     Product Model:           RT—FD4—3B

Test By:                        Zora                                     Test mode:               Tx mode

Test Frequency:                  30 MHz ~ 1 GHz                          Polarization:            Vertical

Test Voltage:                    DC 3V                                   Environment:             Temp: 24°C      Huni: 57%

      120Lt=.l\.'el (dBu\Vim)

      110



       90

                                                                  Fundamental signal
       70

                                                                                         ‘           FCC PART15S CLAS$ 8
       50                                                                                                     5
                                                                                                                        l

       30



       10

            30              50                    100                   200                          500              1000
                                                               Frequency (MHz)

                                  Read&ntenna          Cable   Aux Preamp                    Limit     Over
                    Freq        Level Factor           Loss Factor Factor        Level        Line   Limit Remark

            ~—WBz dBu¥ dB/m _ db = db — dB dBu¥/m dBu¥/m —dB_
      1           43.353         17.52    13.42        1.26      0.00    0.00    32.20       40.00 —7.80 9P
      2          107.13%M        20.38    12.13        2.02      0.00    0.00    34.53       43.50 —8.97 QP
      2          242.525         16.94    13.06        2.82      0.00    0.00    31.82       46.00 —14.18 QP
      4          431.032         18.54    15.88        1.16      0.00    0.00    37.57       46.00 —8.43 qP
      5 x        @31.688         22.79    19.59        1.89      0.00    0.00    46.27                    Peak
      6 x        945.440         26.75    22.39        4.16      0.00    0.00    53.30                    Peak


Remark:
1. Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1809044
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                         Page 16 of 33


CCIS                                                                                   Report No: CCISE180904401


Product Name:                keyless transmitter                     Product Model:            RT—FD4—3B

Test By:                     Zora                                    Test mode:                Tx mode

Test Frequency:              30 MHz ~ 1 GHz                          Polarization:             Horizontal

Test Voltage:                DC 3V                                   Environment:              Temp: 24°C       Huni: 57%

     120Le\'el (dBuVim)

     110


      90                                                     Fundamental signal


      70
                                                                                                                      6
                                                                                                   FCC PART15 CLASS
      50                                                                                                    |
           —_]_—_]                                                                                4
                        1                             2                     3
      30


      10

       030              50                    100                    200                           500               1000
                                                          Frequency (MHz)

                             Readintenna      Cable       Aux Preamp                 Limit      Over
                Freq        Level Factor      Loss Factor Factor           Level      Line     Linit Remark

           CWBz dbuv? db/n _db —db _db dBu¥/m dBbu¥/n —dB
     1        47.994        16.82    13.94    1.27        0.00    0.00      32.03    40.00 —7.97 QP
     2       124.133        21.20      Q.57   2.21        0.00    0.00      32.98    43.50 —10.52 oP
     3       242.525        16.10    13.06    2.82        0.00    0.00      30.98    46.00 —15.02 qP
     4       483.910        17.25    17.07    3.48        0.00    0.00      37.80    46.00 —8.20 QP
     5 *     631.688        27.01    19.59    3.82        0.00    0.00      50.49                 Peak
     6 x     $45.440        33.44    22.39    4.16        0.00    0.00      59.99                 Peak


Remark:
1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1809044
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 17 of 33


c c I s                                                                                   Report No: CCISE180904401



Product Name:                keyless transmitter                          Product Model:            RT—FD4—3B

Test By:                     Zora                                         Test mode:               Tx mode
Test Frequency:              1 GHz ~3.5 GHz                               Polarization:            Vertical

Test Voltage:                DC 3V                                        Environment:              Temp: 24°C         Huni: 57%

     120L(-:‘vel (dBuVim)

     110


      90

                                                                                                               FCC PART 15 (PK)
      70                                              §

                                                                                                               FCC PART 15 (AV)
      50                         1                                    7             4          5               6       3
                                                                                                                       iptstrcmuns}
                                                      [mnoubntirtyect~t
      30


      10

           G1000 1100     1200                1500                        2000                                                 3500
                                                            Frequency (MHz)

                            Read&ntenna       Cable    Aux Preanp                   Limit     Over
                  Freq     Level Factor        Loss Factor Factor          Level     Line    Limit Remark

                   NHz       dBu¥     dB/n       dB         dB       dB dBu¥/m dBu¥/m              dB
      1       1259. 240    56.02     24.51     3.41       2.45   41.056     45.34   74.00 —28.66 Peak
      20      1575.784     T0.91     25.41     3.82       2.22   41.03      61.33   74.00   —12.67      Peak
      3        1889.673    58.92     26.16    4.22        2.46   41.41      50.35   74.00   —23.65      Peak
      4        2204.484    §3.58     26.93    4.50        2.70   41.68      46.03   74.00   —27.97      Peak
      5        2520.706    B4.47     27.66    4.85        2.85   41.90      47.93   74.00   —26.07      Peak
      6       2835.728     52.32     28. 29    5.18       2.89   41.63     47.05    74.00 —26.95 Peak
      T       3164.354     48.11     28.70     5.40       2.92   41.43      43.70   74.00 —30.30 Peak

Remark:
1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
2.   The emission levels of other frequencies are very lowerthan the limit and not show in test report.
3.   Worse AV value=PK+dutycycle factor =61.33—11.97=49.36dBuV/m@1575.784MHz<54dBuV/m




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1809044
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                             Page 18 of 33


CCIS                                                                                                                           Report No: CCISE180904401


Product Name:                            keyless transmitter                                                  Product Model:              RT—FD4—3B

Test By:                                 Zora                                                                 Test mode:                  Tx mode

Test Frequency:                          1 GHz ~3.5 GHz                                                       Polarization:               Horizontal

Test Voltage:                            DC 3V                                                                Environment:                Temp: 24°C        Huni: 57%


      120 Level (dBu\Vim)

      110


           90

                                                                                                                                                 FCC PART 15 (PK)
           70

                                              1                         1                                 4                                      ECC PART 15 (aV)
           50                                                                                                           ;            5           7          7

           30»«.,_«%»/“'«)«""“"""”



            10
                       0
                           1000 1100   1200             1500                                                   2000                                               3500
                                                                              Frequency (MHz)

                                          Read&ntenna       Cable     Aux Preamp                                               Limit         Over
                                         Level Factor        £ 0ss Factor Factor                                      Level     Line       Limit Remark

                                                                                                                dB dBu¥/m dBu¥/n _              dB

                             1259.       64.80    24.51                  41                          45   41.056      54.12    74.   00   —19. 88    Peak
                                                           ongne o s po po

                                                                              ho ho ho ho ho ho ho
      —1 0 ome oo no




                             1575.       68.43    25.41                 .82                          22   41.03       58. 85   74.   00   —15.15     Peak
                             1889.       59.72    26.16                  22                          46   41.41       51.15    74.   00   —22. 85    Peak
                             2207.       50.10    26.93                 .51                          T0   41.69       42. 55   74.   00   —31.45     Peak
                             2520.       52.91    27.66                 .85                          85   41.90       46. 37   74.   00   —27.63     Peak
                             2835.       54.61    28. 29                 18                          89   41.63       49. 34   74.   00   —24. 66    Peak
                             3150.       51.63    28.70                  40                          92   41.43       47. 22   74.   00   —26. 78    Peak
Remark:
1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
2.   The emission levels of other frequencies are very lowerthan the limit and not show in test report.
3.   Worse AV value=PK+dutycycle factor =58.85—11.97=46.88dBuV/m@1575.784MHz<54dBuV/m
     Worse AV value=PK+dutycycle factor =54.12—11.97=42.1 5dBuV/im@ 1 259. 240MHz<54dBu V/m




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                             Project No.: CCISE1809044
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                   Page 19 of 33


                                                                               Report No: CCISE180904401

6.3 20dB and 99% Bandwidth
        Test Requirement:                FCC Part15 C Section 15.231 (c)
                                         RSS-210 Annex A Section A.1.3
        Test Method:                     ANSI C63.10:2013
        Receiver setup:                  RBW=1kHz, VBW=3kHz, detector: Peak
        Limit:                           The bandwidth of the emission shall be no wider than 0.25% of the center
                                         frequency for devices operating above 70 MHz and below 900 MHz. For
                                         devices operating above 900 MHz, the emission shall be no wider than
                                         0.5% of the center frequency. Bandwidth is determined at the points 20
                                         dB down from the modulated carrier.
        Test Procedure:                  1. According to the follow Test-setup, keep the relative position between
                                             the artificial antenna and the EUT.
                                         2. Set the EUT to proper test channel.
                                         3. Max hold the radiated emissions, mark the peak power frequency
                                             point and the -20dB upper and lower frequency points.
                                         4. Read 20dB bandwidth.
        Test setup:




        Test Instruments:                Refer to section 5.7 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
  20dB bandwidth (MHz)              99% BW (MHz)                Limit (MHz)                           Results
            0.019                          0.039                   0.7875                             Passed

Note: 20dB bandwidth Limit= Fundamental frequency×0.25%=315×0.25%=0.7875MHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 20 of 33


                                                                                                           Report No: CCISE180904401

Test plot as follows:
                                                              20dB Bandwidth
                                                                          * RBW        1 kHz   Delta 1 [T1 ]
                                                                          * VBW        3 kHz              -0.67 dB
                           Ref    6.5 dBm           * Att   10 dB             SWT 500 ms           19.000000000 kHz

                                 Offset    6.5 dB                                              Marker 1 [T1 ]

                           0                                                                             -30.24 dBm
                                                                                                  314.997000000 MHz    A


                    1 PK   -10      D1 -9.36 dBm
                    MAXH
                                                                                                                      LVL

                           -20


                                                                      1       1
                           -30            D2 -29.36 dBm




                           -40



                           -50                                                                                        3DB




                           -60



                           -70



                           -80



                           -90

                           Center 315 MHz                           50 kHz/                            Span 500 kHz




                    Date: 15.SEP.2018           09:15:35




                                                          99% Occupy Bandwidth
                                                                          * RBW        1 kHz   Marker 1 [T1 ]
                                                                          * VBW        3 kHz             -14.12 dBm
                           Ref    6.5 dBm             Att   15 dB             SWT 500 ms          315.006000000 MHz

                                 Offset    6.5 dB                                              OBW 39.000000000 kHz

                           0                                                                   Temp 1 [T1 OBW]
                                                                                                         -41.40 dBm    A

                                                                                                  314.988000000 MHz
                    1 PK   -10                                            1                    Temp 2 [T1 OBW]
                    MAXH
                                                                                                         -41.76 dBm LVL
                                                                                                  315.027000000 MHz
                           -20



                           -30


                                                                     T1           T2
                           -40



                           -50                                                                                        3DB
                                                                                                                      AC


                           -60



                           -70



                           -80



                           -90

                           Center 315 MHz                           50 kHz/                            Span 500 kHz




                    Date: 29.SEP.2018           14:24:05




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                          Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                             Page 21 of 33


                                                                              Report No: CCISE180904401

6.4 Duration Time
                                         FCC Part15 C Section 15.231 (a1)
        Test Requirement:
                                         RSS-210 Annex A Section A.1.1 (a)
        Test Method:                     ANSI C63.10: 2013
        Receiver setup:                  RBW=1MHz, VBW=1MHz, span=0Hz, detector: Peak
        Limit:                           Not more than 5 seconds
        Test mode:                       Transmitting mode
        Test Procedure:                  1. According to the follow Test-setup, keep the relative position between
                                            the artificial antenna and the EUT.
                                         2. Set the EUT to proper test channel.
                                         3. Single scan the transmission, and read the transmission time.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data
         Duration time (second)                        Limit (second)                        Result
                 0.496                                     <5.0                               Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 22 of 33


                                                                                                    Report No: CCISE180904401

Test plot as follows:
                                                                         RBW 1 MHz      Delta 2 [T1 ]
                                                                        * VBW   1 MHz               0.03 dB
                             Ref    6.5 dBm          * Att   10 dB       SWT 8 s                5.000000 s

                                   Offset   6.5 dB                                      Marker 1 [T1 ]

                             0                                                                    -68.11 dBm
                                                                                              176.000000 ms     A
                                                                                                               SGL
                                                                                        Delta 1 [T1 ]
                    1 PK *   -10                                                                    0.30 dB
                    CLRWR
                                                                                              496.000000 ms    LVL

                             -20



                             -30



                             -40



                             -50                                                                               3DB




                             -60

                              1     1                                               2

                             -70



                             -80



                             -90

                             Center 315 MHz                          800 ms/




                    Date: 15.SEP.2018           09:19:26




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                   Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                      Page 23 of 33


                                                                                         Report No: CCISE180904401

6.5 Frequency Stability
       Test Requirement:                   RSS-GEN Section 8.11
       Test Method:                        RSS-GEN Section 6.11
       Limit:                              kept within at least the central 80% of its permitted operating frequency band.

       Test setup:




       Test procedure:                     1.    The EUT is installed in an environment test chamber with external
                                                 power source.
                                           2.    Set the chamber to operate at 50 centigrade and external power
                                                 source to output at nominal voltage of EUT.
                                           3.    A sufficient stabilization period at each temperature is used prior to
                                                 each frequency measurement.
                                           4.    When temperature is stabled, measure the frequency stability.
                                           5.    The test shall be performed under -20 to 50 centigrade and 85 to
                                                 115 percent of the nominal voltage. Change setting of chamber
                                                 and external power source to complete all conditions.
       Test Instruments:                   Refer to section 5.7 for details
       Test mode:                          Unmodulated carrier is not available, test at modulated carrier mode.
       Test results:                       Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1809044
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                             Page 24 of 33


c c I s                                                                                       Report No: CCISE180904401

Measurement Data:
Voltage vs. Frequency Stability
             Test conditions                                                                                          ul
       Temp(C)            Voitage(ac)                         Measurement Frequency (MHz)                            Limit (MHz)

                                           s.2V                              315.006
           20                              3.0V                              315.003                                 281 ~ 449
                                           2.5V                              315.008
  Note: EUT stops working when the supply voltage is lower than DC 2.5V.


Temperature vs. Frequency Stability
               Test conditions                                                                                        foas
      Voltage(de)            Temp(C)                                      Frequency(MHz)                             Limit (MHz)

                                           —20                               315.008
                                           —10                               315.001
                                            0                                315.006
                                            10                               315.004
          3.0V                             20                                315.002                                 281   449

                                           30                                315.003
                                           40                                315.001
                                           50                                315.003



Test plot as follows (worst case):


                                  orches    "©    an                                                    I


                                                                                                            es

                    .                                                 :                                     h.


                            ~20                                   }




                            Cencer siso m                      Te n                        Eran soe w



                    Date:    29.989.2018           14:25:25




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                Project No.: CCISE1809044
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                   Page 25 of 33



Document Created: 2018-10-17 01:17:01
Document Modified: 2018-10-17 01:17:01

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC