Test report

FCC ID: 2AOKM-CYV9

Test Report

Download: PDF
FCCID_4307915

                       Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                       Report No: CCISE190408601

1       Cover Page

                      FCC/ IC REPORT
    Applicant:                          Remote Tech LLC
    Address of Applicant:               310 ALDER RD, DOVER DE 19904 USA
    Equipment Under Test (EUT)

     Product Name:                      keyless transmitter
     Model No.:                         RT-454T3, RT-454T4, RT-454T5
    FCC ID:                             2AOKM-CYV9
    Canada IC:                          24223-CYV9
    Applicable standards:               FCC CFR Title 47 Part 15 Subpart C Section 15.231
                                        RSS-210 Issue 9 August 2016 Annex A Section A.1.1
                                        RSS-Gen Issue 5 April 2018
    Date of sample receipt:             23 Apr., 2019
    Date of Test:                       24 Apr., to 06 May., 2019
    Date of report issue:               07 May., 2019
    Test Result:                        PASS*

*    In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




        Bruce Zhang
     Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                 Report No: CCISE190408601


2      Version
     Version No.                         Date                                    Description
            00                     07 May., 2019                                   Original
            01                     03 Jun., 2019                           Update page 5,11,15~18




    Prepared By:                                                         Date:          07 May., 2019

                                       Test Engineer

    Check By:                                                            Date:          07 May., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 2 of 35


                                                                                                                           Report No: CCISE190408601

3         Contents
                                                                                                                                                                               Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST MODE ............................................................................................................................................................ 5
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 5
    5.5         LABORATORY FACILITY.......................................................................................................................................... 6
    5.6         LABORATORY LOCATION ....................................................................................................................................... 6
    5.7         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1     ANTENNA REQUIREMENT ....................................................................................................................................... 8
    6.2     RADIATED EMISSION ............................................................................................................................................. 9
       6.2.1 Field Strength Of The Fundamental Signal .............................................................................................. 11
       6.2.2 Spurious Emissions ..................................................................................................................................... 15
    6.3     20DB BANDWIDTH ............................................................................................................................................... 21
    6.4     DURATION TIME ................................................................................................................................................... 23
    6.5     FREQUENCY STABILITY ........................................................................................................................................ 25
7       TEST SETUP PHOTOS...................................................................................................................................... 27
8       EUT CONSTRUCTIONAL PHOTOS ................................................................................................................. 28




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                          Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                        Page 3 of 35


                                                                                   Report No: CCISE190408601

4       Test Summary
                                                                 Section in CFR 47
                     Test Item                                                                        Result
                                                           FCC                     IC
               Antenna requirement                        15.203              RSS-GEN 6.8              Pass
                                                                          RSS-210 Annex A
     Field strength of the fundamental signal           15.231 (b)                                     Pass
                                                                          Section A.1.2 (a)
                                                                          RSS-210 Annex A
                Spurious emissions                  15.231 (b)/15.209                                  Pass
                                                                          Section A.1.2 (b)
                                                                          RSS-210 Annex A
                 20dB Bandwidth                         15.231 (c)                                     Pass
                                                                            Section A.1.3
                                                                          RSS-210 Annex A
                     Dwell time                        15.231 (a)(1)                                   Pass
                                                                          Section A.1.1 (a)
                                                                               RSS-GEN
                Frequency stability                          /                                         Pass
                                                                              Section 8.11
                                                                               RSS-GEN
               Conducted Emission                         15.207                                       N/A
                                                                               Section 8.8
    Remarks:
    N/A: The EUT not applicable of the test item.
    Pass: The EUT complies with the essential requirements in the standard.
    TEST ACCORDING TO ANSI C63.4:2014 AND ANSI C63.10:2013.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 4 of 35


c c I s                                                                          Report No: CCISE190408601

5         General Information
5.1 Client Information
            Applicant:                      Remote Tech LLC
            Address:                        310 ALDER RD, DOVER DE 19904 USA
            Manufacturer:                   Remote Tech LLC
            Address:                        310 ALDER RD, DOVER DE 19904 USA


5.2 General Description of E.U.T.
            Product Name:                   keyless transmitter
          Model No.:                        RT—454T3, RT—454T4, RT—4547T5
          Operation Frequency:              433.92MHz
          Channel numbers:                  1
          Modulation type:                  ASK
          Antenna Type:                     PCB antenna
          Antenna gain:                     0 dBi
            Power supply:                   DC 3V (CR2032 battery)
            Remark                          Model No.: RT—454T3, RT—454T4, RT—454T5 were identical inside,
                                            the electrical circuit design, layout, components used and internal
                                            wiring, Different model, It‘s just The shell has 3 and 4 and 5 buttons,
                                            the PCB function is the same.

5.3 Test mode
       Transmitting mode:              Keep the EUT in transmitting mode with modulation (new battery used)
    Pre—Test Mode:
    CCIS has verified the construction and function in typical operation, The EUT was placed on three different
    polar directions; .e. X axis, Y axis, Z axis. which was shown in this test report and defined as follows:
                Axis                            X                         Y                           Z
    Field Strength(dBuV/m)                  7711                         76.43                      76.05
    Final Test Mode:
    According to ANSI C63.4 standards, the test results are both the "worst case" and "worst setup": X axis
    (see the test setup photo)


5.4 Description of Support Units
      N/A




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1904086
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                 Page 5 of 35


                                                                            Report No: CCISE190408601

5.5      Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        FCC - Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
        IC - Registration No.: 10106A-1
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.6 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com

5.7 Measurement Uncertainty
                    Parameters                                           Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                   ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                   ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                  ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                    ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                   ±2.88 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 6 of 35


                                                                                     Report No: CCISE190408601

5.8 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date      Cal. Due date
   Test Equipment            Manufacturer             Model No.            Serial No.
                                                                                          (mm-dd-yy)       (mm-dd-yy)
       3m SAC                 SAEMC                   9m*6m*6m               966          07-22-2017       07-21-2020
  BiConiLog Antenna        SCHWARZBECK                VULB9163               497          03-18-2019       03-17-2020
    Horn Antenna           SCHWARZBECK               BBHA9120D               916          03-18-2019       03-17-2020
    Horn Antenna           SCHWARZBECK               BBHA9120D              1805          06-22-2017       06-21-2020
    Horn Antenna           SCHWARZBECK               BBHA 9170           BBHA9170582      11-21-2018       11-20-2019
    Loop Antenna           SCHWARZBECK              FMZB 1519 B              00044        03-18-2019       03-17-2020
  EMI Test Software            AUDIX                    E3                           Version: 6.110919b
    Pre-amplifier                HP                   8447D               2944A09358      03-18-2019       03-17-2020
    Pre-amplifier                CD                  PAP-1G18                11804        03-18-2019       03-17-2020
  Spectrum analyzer        Rohde & Schwarz            FSP30                 101454        03-18-2019       03-17-2020
  Spectrum analyzer        Rohde & Schwarz            FSP40                 100363        11-21-2018       11-20-2019
  EMI Test Receiver        Rohde & Schwarz            ESRP7                   101070      03-18-2019       03-17-2020
  Simulated Station            Anritsu               MT8820C               6201026545     03-18-2019       03-17-2020
       Cable                   ZDECL               Z108-NJ-NJ-81             1608458      03-18-2019       03-17-2020
       Cable                MICRO-COAX               MFR64639                K10742-5     03-18-2019       03-17-2020
       Cable                  SUHNER               SUCOFLEX100              58193/4PE     03-18-2019       03-17-2020
  DC Power Supply             XinNuoEr              WYK-10020K           1409050110020    10-31-2018       10-30-2019
    Temperature
                                HengPu               HPGDS-500           20140828008      09-24-2018       09-23-2019
  Humidity Chamber




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                  Page 7 of 35


                                                                           Report No: CCISE190408601

6      Test results and Measurement Data
6.1 Antenna requirement
        Standard requirement:          FCC Part15 C Section 15.203
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        E.U.T Antenna:
       The EUT make use of an PCB antenna, The typical gain of the antenna is 0 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 8 of 35


                                                                                   Report No: CCISE190408601

6.2 Radiated Emission
                                        FCC Part15 C Section 15.231(b) and 15.209
        Test Requirement:
                                        RSS-210 Annex A Section A.1.2
        Test Method:                    ANSI C63.4:2014
        Test Frequency Range:           30MHz to 5000MHz
        Test site:                      Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                  Frequency         Detector           RBW         VBW           Remark
                                        30MHz-1GHz        Quasi-peak         120kHz      300kHz     Quasi-peak Value
                                        Above 1GHz          Peak              1MHz        3MHz        Peak Value
        Limit:                                 Frequency                 Limit (dBuV/m @3m)           Remark
        (Field strength of the                                                 80.83               Average Value
        fundamental signal)                   433.92MHz
                                                                                 100.83             Peak Value
        Limit:                                  Frequency                Limit (dBuV/m @3m)           Remark
        (Spurious Emissions)                  30MHz-88MHz                         40.0            Quasi-peak Value
                                             88MHz-216MHz                         43.5            Quasi-peak Value
                                            216MHz-960MHz                         46.0            Quasi-peak Value
                                              960MHz-1GHz                         54.0            Quasi-peak Value
                                                                                  54.0             Average Value
                                              Above 1GHz
                                                                                  74.0              Peak Value
                                        Or The maximum permitted unwanted emission level is 20 dB below the
                                         maximum permitted fundamental level whichever limit permits higher field
                                         strength.
        Test Procedure:                 a. The EUT was placed on the top of a rotating table 0.8m(below 1GHz)
                                             /1.5m(above 1GHz) above the ground at a 3 meter chamber. The
                                             table was rotated 360 degrees to determine the position of the highest
                                             radiation.
                                        b. The EUT was set 3 meters away from the interference-receiving
                                             antenna, which was mounted on the top of a variable-height antenna
                                             tower.
                                        c. The antenna height is varied from one meter to four meters above the
                                             ground to determine the maximum value of the field strength. Both
                                             horizontal and vertical polarizations of the antenna are set to make
                                             the measurement.
                                        d. For each suspected emission, the EUT was arranged to its worst case
                                             and then the antenna was tuned to heights from 1 meter to 4 meters
                                             and the rotatable table was turned from 0 degrees to 360 degrees to
                                             find the maximum reading.
                                        e. The test-receiver system was set to Peak Detect Function and
                                             Specified Bandwidth with Maximum Hold Mode.
                                        f. If the emission level of the EUT in peak mode was 10dB lower than
                                             the limit specified, then testing could be stopped and the peak values
                                             of the EUT would be reported. Otherwise the emissions that did not
                                             have 10dB margin would be re-tested one by one using peak, quasi-
                                             peak or average method as specified and then reported in a data
                                             sheet.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 9 of 35


                                                                           Report No: CCISE190408601

        Test setup:                     Below 1GHz




                                        Above 1GHz




        Test Instruments:               Refer to section 5.8 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                   Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                      Page 10 of 35


                                                                                     Report No: CCISE190408601

6.2.1    Field Strength Of The Fundamental Signal
                                                       Peak value
                 Read         Antenna      Cable                                                        Over
Frequency                                               Preamp             Level      Limit Line
                 Level         Factor      Loss                                                         Limit     Polarization
  (MHz)                                                Factor(dB)        (dBuV/m)     (dBuV/m)
                (dBuV)         (dB/m)       (dB)                                                        (dB)
  433.92         54.14         16.11        3.16          0.00            73.41           100.83        -27.42       Vertical
  433.92         57.84         16.11        3.16          0.00            77.11           100.83        -23.72     Horizontal
                                                     Average value
Frequency              Level            Duty Cycle     Average value         Limit Line            Over Limit
                                                                                                                  Polarization
  (MHz)              (dBuV/m)             factor         (dBuV/m)            (dBuV/m)                (dB)
  433.92              73.41               -11.09            62.32                 80.83             -18.51          Vertical
  433.92              77.11               -11.09            66.02                 80.83             -14.81        Horizontal
                                Average value=Peak value + Duty Cycle Factor
   Calculate Formula:           Duty cycle factor = 20log(Duty cycle)
                                Duty cycle = on time/100 milliseconds or period, whichever is less
                                T on time =27.90(ms)
                                T period =126(ms)>100(ms)
        Test data:
                                Duty cycle =27.90
                                Duty cycle factor = 20log(Duty cycle) = -11.09
           Remark               T on time=T3*56+T2*29=0.26*56+0.46*29=27.9ms




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                        Page 11 of 35


                                                                                                                                         Report No: CCISE190408601


                                                T period:                                                                                          T 100ms:
                                                         RBW 1 MHz       Delta 1 [T1 ]                                                                     RBW 1 MHz
                                                        * VBW   1 MHz               -0.00 dB                                                              * VBW   1 MHz
          Ref    5 dBm              * Att   10 dB        SWT 1 s               126.000000 ms                 Ref    5 dBm              * Att   10 dB       SWT 100 ms

                Offset   5 dB                                            Marker 1 [T1 ]                            Offset   5 dB
          0                                                                        -70.27 dBm                0

                                                                               472.000000 ms    A                                                                                                    A
                                                                                                SGL                                                                                                  SGL
   1 PK   -10                                                                                         1 PK   -10
   MAXH                                                                                               MAXH
                                                                                                LVL                                                                                                  LVL
          -20                                                                                                -20



          -30                                                                                                -30



          -40                                                                                                -40



          -50                                                                                                -50
                                                                                                3DB                                                                                                  3DB
                                                                                                AC                                                                                                   AC


          -60                                                                                                -60


                                                    1           1
          -70                                                                                                -70



          -80                                                                                                -80



          -90                                                                                                -90


          Center 433.92 MHz                         100 ms/                                                  Center 433.92 MHz                         10 ms/




   Date: 25.APR.2019            15:15:35                                                              Date: 25.APR.2019            15:15:50



                                       T on time slot-1:                                                                                  T on time slot-2:
                                                         RBW 1 MHz                                                                                         RBW 1 MHz          Delta 1 [T1 ]
                                                        * VBW   1 MHz                                                                                     * VBW   1 MHz                  -1.12 dB
          Ref    5 dBm              * Att   10 dB        SWT 50 ms                                           Ref    5 dBm              * Att   10 dB       SWT 10 ms                460.000000 µs

                Offset   5 dB                                                                                      Offset   5 dB                                              Marker 1 [T1 ]
          0                                                                                                  0                                                                          -72.68 dBm
                                                                                                A                                                                                     6.180000 ms    A
                                                                                                SGL                                                                                                  SGL
   1 PK   -10                                                                                         1 PK   -10
   MAXH                                                                                               MAXH
                                                                                                LVL                                                                                                  LVL
          -20                                                                                                -20



          -30                                                                                                -30



          -40                                                                                                -40



          -50                                                                                                -50
                                                                                                3DB                                                                                                  3DB
                                                                                                AC                                                                                                   AC


          -60                                                                                                -60



          -70                                                                                                -70                                                   1
                                                                                                                                                                          1



          -80                                                                                                -80



          -90                                                                                                -90


          Center 433.92 MHz                          5 ms/                                                   Center 433.92 MHz                         1 ms/




   Date: 25.APR.2019            15:16:24                                                              Date: 25.APR.2019            13:00:06



                                       T on time slot-3:
                                                         RBW 1 MHz       Delta 1 [T1 ]
                                                        * VBW   1 MHz               -0.42 dB
          Ref    5 dBm              * Att   10 dB        SWT 10 ms             260.000000 µs

                Offset   5 dB                                            Marker 1 [T1 ]
          0                                                                        -73.16 dBm
                                                                                 7.020000 ms    A
                                                                                                SGL
   1 PK   -10
   MAXH
                                                                                                LVL
          -20



          -30



          -40



          -50
                                                                                                3DB
                                                                                                AC


          -60



          -70                                                           1 1



          -80



          -90


          Center 433.92 MHz                          1 ms/




   Date: 25.APR.2019            13:00:54




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                            Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                                      Page 12 of 35


CCIS                                                                                 Report No: CCISE190408601

Test Plots:
Product Name:                  Keyless transmitter                   Product Model:            RT—454T3

Test By:                       Mike                                  Test mode:                Tx mode

Test Frequency:                433.92 MHz                            Polarization:             Vertical

Test Voltage:                  DC 3V                                 Environment:              Temp: 24°C   Huni: 57%


           110Le'.'e| (dBuVim)


           100


            so                                                                  7

            60                                                                       \\


            40                                                                             _

            20


                 432 432.2        432.5                                                                      435
                                                         Frequency (MHz)



                                     ReadAntenna     Cable Preamp              Linmit    Over
                           Freq     Level Factor      Loss Factor     Level     Line    Limit Remark

                  ~——        NHz — dBuy     db/m                d5 dBu¥/m dBu¥/nm              dB
            1           433.990     54.14   16.11            0:00.    13.41, ——————



Remark:
1.   _Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1904086
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 13 of 35


CCIS                                                                                       Report No: CCISE190408601


Product Name:                   Keyless transmitter                      Product Model:          RT—454T3

Test By:                        Mike                                 Test mode:                  Tx mode

Test Frequency:                 433.92 MHz                               Polarization:           Horizontal

Test Voltage:                    DC 3V                                   Environment:            Temp: 24°C     Huni: 57%


              110Level (dBuVim)


              100


               80                                                                   1
                                                                                4
               60

                                                                                                              ~—_I
               40


               20


                    432 432.2     432.5                                                                          435
                                                           Frequency (MHz)


                                    Read&ntenna       Cable Preanp                      Limit    Over
                          Freq     Level Factor        Loss Factor         Level         Line   Limit Remark

                ~— WHz dBu¥y db/mdb _dB dBu¥/m dBu¥/m —db —
          1           433.987      57.84     16.11     2.16:    (©.00.     T111 ——————‘=—=~—~



Remark:
1.   _Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1904086
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 14 of 35


                                                                                Report No: CCISE190408601

6.2.2    Spurious Emissions
                                           Below 1GHz (30MHz-1000MHz)
                                                        peak value
                 Read         Antenna     Cable      Preamp
Frequency                                                        Level      Limit Line       Over Limit
                 Level         Factor     Loss        Factor                                               polarization
  (MHz)                                                       (dBuV/m)      (dBuV/m)           (dB)
               (dBuV/m)        (dB/m)      (dB)        (dB)
  867.84         34.08          22.56     4.01         0.00     60.65         80.83            -20.18        Vertical
  867.84         39.40         22.56       4.01       0.00        65.97       80.83            -14.86      Horizontoal
                                                     Average value
Frequency             Level             Duty Cycle     Average value      Limit Line       Over Limit
                                                                                                           Polarization
  (MHz)             (dBuV/m)              factor         (dBuV/m)         (dBuV/m)           (dB)
  867.84              60.65               -11.09             49.56          60.83            -11.27          Vertical
  867.84              65.97               -11.09             54.88          60.83             -5.95        Horizontal




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                 Page 15 of 35


CCIS                                                                                                     Report No: CCISE190408601

Test Plots:
Product Name:               Keyless transmitter                                          Product Model:       RT—454T3

Test By:                    Mike                                                         Test mode:           Tx mode

Test Frequency:             30 MHz ~ 1 GHz                                               Polarization:        Vertical

Test Voltage:               DC 3V                                                        Environment:         Temp: 24°C      Huni: 57%


            80Level (dBuVim)


            70                                                                           Fundamental signal




                                                                                                                         ol
            ik                                                                                                FCC PART15 CLAYS B
            50}




                  30        50                  100                                      200                  500              1000
                                                                         Frequency (MHz)


                                    Readint enna      Cable Preamp                                             Over
                          Freq     Level Factor              Loss Factor                       Level          Limit Remark

                            MHz      dBu¥      dB/m

                  1      41.567    16.84     12.37
                                                       & & G) ho No ++




                                                                                pprppp




                  2      94.098    17.09     11.08
                  3     120.699    17.18     10.85
                  4     341.979    iT.17     14.44
                  5     724.261    19.41     20.50
                  6 *   869.130    34.08     22.56


Remark:
1. Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                  Project No.: CCISE1904086
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                     Page 17 of 35


CCIS                                                                                   Report No: CCISE190408601


Product Name:              Keyless transmitter                       Product Model:             RT—454T3

Test By:                   Mike                                      Test mode:                Tx mode

Test Frequency:            30 MHz ~ 1 GHz                            Polarization:              Horizontal

Test Voltage:              DC 3V                                     Environment:              Temp: 24°C        Huni: 57%


           o Level (dBuVim)

           70                                                         Fundamental signal                     &

           60
                                                                                               FCC PART15 CLASS 8
           50

           40


           30

           20

           10


                30         50                  100                 200                         500               1000
                                                         Frequency (MHz)


                                   Readéntenna        Cable Preamp                  Limit      Over
                         Freq     Level Factor          Loss Factor        Level     Line     Limit Remark

                          NHz      dBu¥y     db/m         dB        dB dBu¥/n dBu¥/n                 dB _
                1      49.014     17.92     12.14      1.26      0.00      31.32    40.00 —8.68 qP
                2      94.428     16.35     11.19      2.01      0.00      29.55    43.50 —13.95 QP
                3     35§5.427    17.21     14.69      3.10      0.00      35.00    46.00 —11.00 qP
                4     586. 84q    18.84     19.23      3.93      0.00      42.00    46.00 —4.00 QP
                5     TO6.7T00    19.29     20.42      4.20      0.00      43.91    46.00 —2.09 QP
                6 *   869.130     39.40     22.56      4.01      0.00      65.97    46.00 19.97 Peak


Remark:
1. Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1904086
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                        Page 18 of 35


CCIS                                                                                               Report No: CCISE190408601



Product Name:                     Keyless transmitter                      Product Model:                  RT—454T3

Test By:                          Mike                                     Test mode:                      Tx mode
Test Frequency:                   1 GHz ~ 5 GHz                            Polarization:                   Vertical

Test Voltage:                     DC 3V                                    Environment:                    Temp: 24°C        Huni: 57%


               80Level (dBuVim)
                                                                                                               FCC PART 15 (PK)
               70

               60
                                                                                                               FCC PART 15 (AV)
               50                   j                1                             7
                                                                      3                        R                J psaanttoaneited
               40

               30

               20

               10


                    1000    1200            1500                2000                                                         5000
                                                                 Frequency (MHz)

                                    Read&ntenna      Cable     Aux Preamp                          Limit      Over
                           Freq    Level Factor        Loss Factor Factor              Level        Line     Limit Remark

                            MHz      dBu¥     dB/m         dB        dB       dB dBu¥/m dBu¥/m                  dB
           1         1302.060      §7.59     24.71       3.47      1.25   41.04        45.98       74.00 —28.02 Peak
          2          1736.788      61.24     25.54       4.03      1.47   41.15        51.13       74.00   —22.87     Peak
          3          2168. T25     52.42     26.38       4.48      1.64   41.68        43.24       74.00   —30.76     Peak
          4          2605.477      53.27     27.64       4.95      1.75   41.88        45.73       74.00   —28.27     Peak
          5           3035.913     45.85     28.51       5.36      1.92   41.49        40.15       74.00   —33.85     Peak
          6          3475.384      50.78     28.60       5.73      2.18   41.43        45.86       74.00   —28.14     Peak
           T          3908.657     46.83     30.01       6.10      2.20   41.80        43.34       74.00 —30.66 Peak
           8         4339.709      46.08     30.37       6.62      2.31   41.92        43.46       74.00 —30.54 Peak

Remark:
1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                               Project No.: CCISE1904086
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                    Page 19 of 35


c c I s                                                                                      Report No: CCISE190408601


Product Name:                    Keyless transmitter                      Product Model:            RT—454T3

Test By:                         Mike                                     Test mode:                Tx mode

Test Frequency:                  1 GHz ~ 5 GHz                            Polarization:             Horizontal

Test Voltage:                    DC 3V                                    Environment:              Temp: 24°C          Huni: 57%


              80Level (dBuVim)
                                                                                                       FCC PART 15 (PK)
              70

              60                                     3
                                                     1                                                 FCC PART 15 (AV)
              50                    ;                                                           6       %
                                                                                                              8
              40

              30

              20

              10

                   1000    1200            1500             2000                                                        5000
                                                                Frequency (MHz)
                                    ReadAntenna        Cable        Aux Preamp                Linit      Over
                          Freq     Level Factor          Loss Factor Factor          Level     Line    Limit Remark

                           MHz      dBu¥      dB/m         dB        dB           dB dBu¥/m dBu¥/m         dB

          1         1302.060       §8.26    24.71        3.47      1.25    41.04     46.65    74.00   —27.35     Peak
          2          1736.788      66.30    25.54        4.03      1.47    41.15     56.19    74.00   —17.81     Peak
          3          2168.725      52.62    26.38        4.48      1.64    41.68     43.44    74.00   —30.56     Peak
          4          2606.477      56.15    27.65        4.95      1.75    41.88     48.62    T4.00   —25.38     Peak
          5         3040.803       51.43    28.51        5.37      1.92    41.49     45.74    74.00   —28.26     Peak
          6          3475.384      53.73    28.60        5.73      2.18    41.43     48.81    74.00   —25.19     Peak
          T          3908.657      49.87    30.01        6.10      2.20    41.80     46.38    74.00   —27.62     Peak
          8         4339.709       46.37    30.37        6.62      2.31    41.92     43.75    74.00   —30.25     Peak

Remark:
1. Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1904086
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                               Page 20 of 35


                                                                               Report No: CCISE190408601

6.3 20dB Bandwidth
        Test Requirement:                FCC Part15 C Section 15.231 (c)
                                         RSS-210 Annex A Section A.1.3
        Test Method:                     ANSI C63.4:2014
        Receiver setup:                  RBW=1kHz, VBW=3kHz, detector: Peak
        Limit:                           The bandwidth of the emission shall be no wider than 0.25% of the center
                                         frequency for devices operating above 70 MHz and below 900 MHz. For
                                         devices operating above 900 MHz, the emission shall be no wider than
                                         0.5% of the center frequency. Bandwidth is determined at the points 20
                                         dB down from the modulated carrier.
        Test Procedure:                  1. According to the follow Test-setup, keep the relative position between
                                            the artificial antenna and the EUT.
                                         2. Set the EUT to proper test channel.
                                         3. Max hold the radiated emissions, mark the peak power frequency
                                            point and the -20dB upper and lower frequency points.
                                         4. Read 20dB bandwidth.
        Test setup:




        Test Instruments:                Refer to section 5.7 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data
  20dB bandwidth (MHz)                 Limit (MHz)              99% Occupy Bandwidth (MHz)            Results
            0.0270                        1.0848                            0.0900                    Passed

Note: Limit= Fundamental frequency×0.25%=433.92×0.25%=1.0848MHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 21 of 35


                                                                                                             Report No: CCISE190408601

Test plot as follows:
                                                                20dB Bandwidth
                                                                          * RBW   1 kHz        Delta 1 [T1 ]
                                                                          * VBW   3 kHz                      0.78 dB
                           Ref    5 dBm               * Att   10 dB        SWT 500 ms                27.000000000 kHz

                                 Offset    5 dB                                                Marker 1 [T1 ]
                           0                                                                               -52.84 dBm
                                                                                                    433.975000000 MHz    A


                    1 PK   -10
                    MAXH
                                                                                                                        LVL
                           -20


                                    D1 -27.52 dBm
                           -30



                           -40


                                          D2 -47.52 dBm
                           -50                                                     1       1
                                                                                                                        3DB
                                                                                                                        AC


                           -60



                           -70



                           -80



                           -90


                           Center 433.92 MHz                          50 kHz/                            Span 500 kHz




                    Date: 25.APR.2019             12:13:49




                                                          99% Occupy Bandwidth
                                                                          * RBW   1 kHz        Marker 1 [T1 ]
                                                                          * VBW   3 kHz                    -27.69 dBm
                           Ref    5 dBm               * Att   10 dB        SWT 500 ms               433.989000000 MHz

                                 Offset    5 dB                                                OBW 90.000000000 kHz
                           0                                                                   Temp 1 [T1 OBW]
                                                                                                           -57.73 dBm    A

                                                                                                    433.938000000 MHz
                    1 PK   -10
                                                                                               Temp 2 [T1 OBW]
                    MAXH
                                                                                                           -61.35 dBm LVL

                           -20                                                                      434.028000000 MHz

                                                                                       1

                           -30



                           -40



                           -50
                                                                                                                        3DB
                                                                           T1                                           AC

                                                                                               T2
                           -60



                           -70



                           -80



                           -90


                           Center 433.92 MHz                          50 kHz/                            Span 500 kHz




                    Date: 25.APR.2019             12:12:39




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                            Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                               Page 22 of 35


                                                                              Report No: CCISE190408601

6.4 Duration Time
                                         FCC Part15 C Section 15.231 (a)(1)
        Test Requirement:
                                         RSS-210 Annex A Section A.1.1 (a)
        Test Method:                     ANSI C63.10: 2013
        Receiver setup:                  RBW=100kHz, VBW=300kHz, span=0Hz, detector: Peak
        Limit:                           Not more than 5 seconds
        Test mode:                       Transmitting mode
        Test Procedure:                  1. According to the follow Test-setup, keep the relative position between
                                            the artificial antenna and the EUT.
                                         2. Set the EUT to proper test channel.
                                         3. Single scan the transmission, and read the transmission time.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data
         Duration time (second)                        Limit (second)                        Result
                 0.592                                     <5.0                               Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 23 of 35


                                                                                                      Report No: CCISE190408601

Test plot as follows:
                                                                           RBW 1 MHz      Delta 2 [T1 ]
                                                                          * VBW   1 MHz              -1.05 dB
                           Ref      5 dBm              * Att   10 dB       SWT 8 s                5.000000 s

                                   Offset   5 dB                                          Marker 1 [T1 ]
                           0                                                                        -69.08 dBm
                                                                                                240.000000 ms     A
                                                                                                                 SGL
                                                                                          Delta 1 [T1 ]
                    1 PK   -10
                                                                                                      0.01 dB
                    MAXH
                                                                                                592.000000 ms    LVL
                           -20



                           -30



                           -40



                           -50
                                                                                                                 3DB
                                                                                                                 AC


                           -60

                               1      1                                               2
                           -70



                           -80



                           -90


                           Center 433.92 MHz                           800 ms/




                    Date: 25.APR.2019              12:57:54




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                     Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                        Page 24 of 35


                                                                                Report No: CCISE190408601

6.5 Frequency stability
       Test Requirement:                   RSS-GEN Section 8.11
       Test Method:                        RSS-GEN Section 6.11
       Limit:                              kept within at least the central 80% of its permitted operating frequency
                                           band.
       Test setup:




       Test procedure:                     1.   The EUT is installed in an environment test chamber with external
                                                power source.
                                           2.   Set the chamber to operate at 50 centigrade and external power
                                                source to output at nominal voltage of EUT.
                                           3.   A sufficient stabilization period at each temperature is used prior to
                                                each frequency measurement.
                                           4.   When temperature is stabled, measure the frequency stability.
                                           5.   The test shall be performed under -20 to 50 centigrade and 85 to
                                                115 percent of the nominal voltage. Change setting of chamber
                                                and external power source to complete all conditions.
       Test Instruments:                   Refer to section 5.8 for details
       Test mode:                          Refer to section 5.3 for details
       Test results:                       Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1904086
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 25 of 35


c c I s                                                                                Report No: CCISE190408601

Measurement Data (worst case):
Voltage vs. Frequency Stability

       Temp(.c')l'est condmoczna ge(de)                 Measurement Frequency (MHz)                        Limit (MHz)

                                   s2V                              433.9890
           20                      8.0Vv                            433.9886                                 +80%
                                   2.5V                             433.9887
  Note: EUT stops working when the supply voltage is lower than DC 2.5V.


Temperature vs. Frequency Stability
                Test conditions
                                Temp(C)                           Frequency(MHz)                           Limit (MHz)
      Voltage(de)
                                  20                                 433.9884
                                  —10                                433.9883
                                   0                                 433.9884
                                   10                                433.9893                              281
          BV                        20                              433.9882                                81 ~ 44 ~4 9
                                    30                              433.9886
                                    40                              433.9897
                                    50                              433.9883
Test plot as follows :




                                                                                                  es

                    Td
                                                                    Eosha —




                         ~s0
                         Cancer «23.02 muz               so knz                    span 500 knz




                    Date: 25.APR.2019        12:12:00




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1904086
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 26 of 35



Document Created: 2019-06-05 18:43:07