Test report

FCC ID: 2AOKM-CYV3

Test Report

Download: PDF
FCCID_4074707

M Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                      Report No: CCISE1809101201




                         FCC/IC REPORT
    Applicant:                          Remote Tech LLC

    Address of Applicant:               310 ALDER RD, DOVER DE 19904 USA

    Equipment Under Test (EUT)

     Product Name:                      keyless transmitter

     Model No.:                         RT—CY33B, RT—CY34B, RT—CY35B,. RT—CY36B

    FCC ID:                             2AOKM—CYV3

    IC:                                 24223—CYV3

    Applicable standards:               FCC CFR Title 47 Part 15 Subpart C,15.231
                                        RSS—Gen Issue 5 April 2018
                                        RSS—210 Issue 9 August 2016,Annex A

    Date of sample receipt:             25 Sep., 2018

    Date of Test:                       12 Sep., to 25 Sep., 2018

    Date of report issue:               23 Oct., 2018

    Test Result:                        PASS*

*    In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




        Bruce Zhang
     Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                 Report No: CCISE180910201


2      Version
     Version No.                         Date                                    Description
            00                      23 Oct., 2018                                  Original




    Prepared By:                                                         Date:          23 Oct., 2018

                                       Test Engineer

    Check By:                                                            Date:          23 Oct., 2018

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 2 of 32


                                                                                                                           Report No: CCISE180910201



3         Contents
                                                                                                                                                                               Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST MODE ............................................................................................................................................................ 5
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 5
    5.5         LABORATORY FACILITY.......................................................................................................................................... 6
    5.6         LABORATORY LOCATION ....................................................................................................................................... 6
    5.7         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1     ANTENNA REQUIREMENT ....................................................................................................................................... 8
    6.2     RADIATED EMISSION ............................................................................................................................................. 9
       6.2.1 Field Strength Of The Fundamental Signal .............................................................................................. 11
       6.2.2 Spurious Emissions ..................................................................................................................................... 15
    6.3     20DB BANDWIDTH ............................................................................................................................................... 20
    6.4     DURATION TIME ................................................................................................................................................... 22
    6.5     FREQUENCY STABILITY ....................................................................................................................................... 24
7       TEST SETUP PHOTOS...................................................................................................................................... 26
8       EUT CONSTRUCTIONAL PHOTOS ................................................................................................................. 27




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                            Page 3 of 32


CCIS                                                                                Report No: CCISE180910201

4      Test Summary
                                                                Section in CFR 47
                   Test Item                                                                            Result
                                                          FCC                     IC
             Antenna requirement                         15.203             RSS—GEN 6.8                  Pass
      .                                .                                   RSS—210 Annex A
    Field strength of the fundamental signal           15.231 (b)           Section A.1.2 (a)            Pass

                  .       ws                                               RSS—210 Annex A
              Spurious emissions                   15.231 (b)15.209         Section A.1.2 (b)            Pass

                                    .                                       RSS—210 A.1.3
          20dB and 99%
                     o
                       Bandwidth                       15.231 (c)            RSS—GEN 6.7                 Pass

                      sw                                                 RSS—210 Annex A
                 Duration time                         15.231 (at)        Section A.1.1 (a)              Pass

                               in                                             RSS—GEN
              Frequency stability                           /                 611811                     Pass


             Conducted Emission                          15.207              RSS—GEN 8.8                  N/A

 Remarks:
 N/A: The EUT not applicable of the test item.
 Pass: The EUT complies with the essential requirements in the standard.
 TEST ACCORDING TO ANSI €63.4:2014 AND ANSI C63.10:2013.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE18091012
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 4 of 32


CCIS                                                                                 Report No: CCISE180910201

5         General Information
5.1 Client Information
            Applicant:                      Remote Tech LLC
            Address of Applicant:           310 ALDER RD, DOVER DE 19904 USA
            Manufacturer:                   Remote Tech LLC
            Address of Manufacturer:        310 ALDER RD, DOVER DE 19904 USA

5.2 General Description of E.U.T.
            Product Name:                   keyless transmitter
          Model No.:                        RT—CY33B, RT—CY34B, RT—CY35B, RT—CY36B
          Operation Frequency:              315MHz
          Channel numbers:                  1
          Modulation type:                  ASK
          Antenna Type:                     PCB antenna
          Antenna gain:                     0 dBi
            Power supply:                   DC 3V (CR2032 battery)
          Test Sample Condition:            The test samples were provided in good working order with no visible
                                            defects.
            Remark:                         Model No.: RT—CY33B, RT—CY34B, RT—CY35B. RT—CY36B are
                                            electrically identical, only except RT—CY33B have 3 buttons , RT—CY34B
                                            have 4 buttons, RT—CY358 have 5 buttons, RT—CY368 have 6 buttons.



5.3 Test mode
       Transmitting mode:              Keep the EUT in transmitting mode with modulation (new battery used)
    Pre—Test Mode:
    CCIS has verified the construction and function in typical operation, The EUT was placed on three different
    polar directions; .e. X axis, Y axis, Z axis. which was shown in this test report and defined as follows:
                Axis                            X                             Y                                 Z
    Field Strength(dBuV/m)                  75.72                          75.70                            75.68
    Final Test Mode:
    According to ANSI C63.4 standards, the test results are both the "worst case" and "worst setup": X axis
    (see the test setup photo)


5.4 Description of Support Units
      N/A




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE18091012
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                            Page 5 of 32


                                                                            Report No: CCISE180910201

5.5      Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        FCC - Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
        IC - Registration No.: 10106A-1
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.6 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com

5.7 Measurement Uncertainty
                    Parameters                                           Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                   ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                   ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                  ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                    ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                   ±2.88 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                          Page 6 of 32


                                                                                     Report No: CCISE180910201

5.8 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date      Cal. Due date
   Test Equipment            Manufacturer             Model No.            Serial No.
                                                                                          (mm-dd-yy)       (mm-dd-yy)
       3m SAC                  SAEMC                  9m*6m*6m               966          07-22-2017       07-21-2020
  BiConiLog Antenna         SCHWARZBECK               VULB9163               497          03-16-2018       03-15-2019
  Broadband Antenna         SCHWARZBECK               VUBA9117               359          06-22-2017       06-21-2020
     Horn Antenna           SCHWARZBECK              BBHA9120D               916          03-16-2018       03-15-2019
     Horn Antenna           SCHWARZBECK              BBHA9120D               1805         06-22-2017       06-21-2020
     Horn Antenna           SCHWARZBECK               BBHA9170               582          11-21-2017       11-20-2018
    Loop Antenna            SCHWARZBECK              FMZB1519 B              00044       04-28-2018        04-27-2019
  EMI Test Software             AUDIX                    E3                          Version: 6.110919b
     Pre-amplifier                HP                   8447D              2944A09358     03-07-2018        03-06-2019
     Pre-amplifier                CD                  PAP-1G18               11804       03-07-2018        03-06-2019
  Spectrum analyzer         Rohde & Schwarz            FSP30                101454       03-07-2018        03-06-2019
  Spectrum analyzer         Rohde & Schwarz            FSP40                100363       11-21-2017        11-20-2018
   EMI Test Receiver        Rohde & Schwarz            ESRP7                  101070      03-07-2018       03-06-2019
   Simulated Station            Anritsu               MT8820C              6201026545     03-07-2018       03-06-2019
        Cable                   ZDECL               Z108-NJ-NJ-81            1608458      03-07-2018       03-06-2019
        Cable                MICRO-COAX               MFR64639               K10742-5     03-07-2018       03-06-2019
        Cable                  SUHNER               SUCOFLEX100             58193/4PE     03-07-2018       03-06-2019
   DC Power Supply             XinNuoEr              WYK-10020K          1409050110020    10-31-2017       10-30-2018
     Temperature                                                                          09-24-2017       09-23-2018
                                HengPu               HPGDS-500            20140828008
   Humidity Chamber                                                                       09-24-2018       09-23-2019




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 7 of 32


                                                                           Report No: CCISE180910201

6      Test results and Measurement Data
6.1 Antenna requirement
        Standard requirement:          FCC Part15 C Section 15.203
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        E.U.T Antenna:
       The EUT make use of a PCB antenna, The typical gain of the antenna is 0 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 8 of 32


                                                                                   Report No: CCISE180910201

6.2 Radiated Emission
                                        FCC Part15 C Section 15.231 (b)/15.209
        Test Requirement:
                                        RSS-210 Annex A Section A.1.2 (a)(b)
        Test Method:                    ANSI C63.10:2013
        Test Frequency Range:           30MHz to 3500MHz
        Test site:                      Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                  Frequency       Detector         RBW       VBW                   Remark
                                        30MHz-1GHz      Quasi-peak      120kHz     300kHz             Quasi-peak Value
                                        Above 1GHz        Peak            1MHz      3MHz                Peak Value
        Limit:                                Frequency            Limit (dBuV/m @3m)                  Remark
        (Field strength of the                                                 75.62                 Average Value
                                                 315MHz
        fundamental signal)                                                      95.62               Peak Value
        Limit:                                  Frequency                Limit (dBuV/m @3m)            Remark
        (Spurious Emissions)                  30MHz-88MHz                         40.0             Quasi-peak Value
                                             88MHz-216MHz                         43.5             Quasi-peak Value
                                            216MHz-960MHz                         46.0             Quasi-peak Value
                                              960MHz-1GHz                         54.0             Quasi-peak Value
                                                                                  54.0              Average Value
                                              Above 1GHz
                                                                                  74.0               Peak Value
                                        Or The maximum permitted unwanted emission level is 20 dB below the
                                         maximum permitted fundamental level whichever limit permits higher field
                                         strength.
        Test Procedure:                 a. The EUT was placed on the top of a rotating table 0.8m(below 1GHz)
                                             /1.5m(above 1GHz) above the ground at a 3 meter chamber. The
                                             table was rotated 360 degrees to determine the position of the highest
                                             radiation.
                                        b. The EUT was set 3 meters away from the interference-receiving
                                             antenna, which was mounted on the top of a variable-height antenna
                                             tower.
                                        c. The antenna height is varied from one meter to four meters above the
                                             ground to determine the maximum value of the field strength. Both
                                             horizontal and vertical polarizations of the antenna are set to make
                                             the measurement.
                                        d. For each suspected emission, the EUT was arranged to its worst case
                                             and then the antenna was tuned to heights from 1 meter to 4 meters
                                             and the rotatable table was turned from 0 degrees to 360 degrees to
                                             find the maximum reading.
                                        e. The test-receiver system was set to Peak Detect Function and
                                             Specified Bandwidth with Maximum Hold Mode.
                                        f. If the emission level of the EUT in peak mode was 10dB lower than
                                             the limit specified, then testing could be stopped and the peak values
                                             of the EUT would be reported. Otherwise the emissions that did not
                                             have 10dB margin would be re-tested one by one using peak, quasi-
                                             peak or average method as specified and then reported in a data
                                             sheet.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 9 of 32


                                                                           Report No: CCISE180910201

        Test setup:                     Below 1GHz




                                        Above 1GHz




        Test Instruments:               Refer to section 5.7 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                     Page 10 of 32


                                                                                     Report No: CCISE180910201

6.2.1    Field Strength Of The Fundamental Signal
                                                       Peak value
                 Read          Antenna     Cable                                                      Over
Frequency                                               Preamp         Level         Limit Line
                 Level          Factor     Loss                                                       Limit     Polarization
  (MHz)                                                Factor(dB)    (dBuV/m)        (dBuV/m)
                (dBuV)          (dB/m)      (dB)                                                      (dB)
   315           39.36          13.92       2.99          0.00           56.27           95.62        -39.35      Vertical
   315           58.81          13.92       2.99          0.00           75.72           95.62        -19.90    Horizontoal
                                                      Average value
Frequency               Level            Duty Cycle    Average value        Limit Line           Over Limit
                                                                                                               Polarization
  (MHz)               (dBuV/m)             factor        (dBuV/m)           (dBuV/m)               (dB)
   315                 56.27               -10.26          46.01                 75.62            -29.61         Vertical
   315                 75.72               -10.26          65.46                 75.62            -10.16       Horizontoal
                                 Average value=Peak value + Duty Cycle Factor
   Calculate Formula:            Duty cycle factor = 20log(Duty cycle)
                                 Duty cycle = on time/100 milliseconds or period, whichever is less
                                 T on time =0.26X49+0.46X39=12.74+17.94=30.68(ms)
                                 T period =128(ms)>100(ms)
         Test data:
                                 Duty cycle =30.68%
                                 Duty cycle factor = 20log(Duty cycle) = -10.26




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                      Page 11 of 32


                                                                                                                                                 Report No: CCISE180910201


                                                  T period:                                                                                                     T 1:
                                                          RBW 1 MHz          Delta 1 [T1 ]                                                                       RBW 1 MHz        Delta 1 [T1 ]
                                                         * VBW   1 MHz                   1.33 dB                                                                * VBW     1 MHz                 2.19 dB
            Ref    5 dBm              * Att   10 dB       SWT 1 s                  128.000000 ms                   Ref    5 dBm              * Att   10 dB       SWT 100 ms                48.200000 ms

                  Offset   5 dB                                              Marker 1 [T1 ]                              Offset   5 dB                                            Marker 1 [T1 ]
            0                                                                          -70.58 dBm                  0                                                                          -72.40 dBm
                                                                                   184.000000 ms    A                                                                                      30.400000 ms    A
                                                                                                    SGL                                                                                                    SGL
   1 PK *   -10                                                                                           1 PK *   -10
   CLRWR                                                                                                  CLRWR
                                                                                                    LVL                                                                                                    LVL
            -20                                                                                                    -20



            -30                                                                                                    -30



            -40                                                                                                    -40



            -50                                                                                                    -50
                                                                                                    3DB                                                                                                    3DB
                                                                                                    AC                                                                                                     AC


            -60                                                                                                    -60

                                      1                                                                                                                                               1
                           1
            -70                                                                                                    -70                       1




            -80                                                                                                    -80



            -90                                                                                                    -90


            Center 315 MHz                            100 ms/                                                      Center 315 MHz                            10 ms/




   Date: 27.SEP.2018              18:12:53                                                                Date: 27.SEP.2018              18:13:56




                                                      T 1-002:                                                                                                  T 2:
                                                          RBW 1 MHz                                                                                              RBW 1 MHz        Delta 1 [T1 ]
                                                         * VBW   1 MHz                                                                                          * VBW     1 MHz                 0.87 dB
            Ref    5 dBm              * Att   10 dB       SWT 50 ms                                                Ref    5 dBm              * Att   10 dB       SWT 10 ms                260.000000 µs

                  Offset   5 dB                                                                                          Offset   5 dB                                            Marker 1 [T1 ]
            0                                                                                                      0                                                                          -73.49 dBm
                                                                                                    A                                                                                       5.700000 ms    A
                                                                                                    SGL                                                                                                    SGL
   1 PK *   -10                                                                                           1 PK *   -10
   CLRWR                                                                                                  CLRWR
                                                                                                    LVL                                                                                                    LVL
            -20                                                                                                    -20



            -30                                                                                                    -30



            -40                                                                                                    -40



            -50                                                                                                    -50
                                                                                                    3DB                                                                                                    3DB
                                                                                                    AC                                                                                                     AC


            -60                                                                                                    -60



            -70                                                                                                    -70                                                    1
                                                                                                                                                                      1



            -80                                                                                                    -80



            -90                                                                                                    -90


            Center 315 MHz                             5 ms/                                                       Center 315 MHz                            1 ms/




   Date: 27.SEP.2018              18:14:29                                                                Date: 27.SEP.2018              18:16:53




                                                          T3
                                                          RBW 1 MHz          Delta 1 [T1 ]
                                                         * VBW   1 MHz                   1.61 dB
            Ref    5 dBm              * Att   10 dB       SWT 10 ms                460.000000 µs

                  Offset   5 dB                                              Marker 1 [T1 ]
            0                                                                          -74.72 dBm
                                                                                     6.340000 ms    A
                                                                                                    SGL
   1 PK *   -10
   CLRWR
                                                                                                    LVL
            -20



            -30



            -40



            -50
                                                                                                    3DB
                                                                                                    AC


            -60



            -70                                                          1
                                                                    1


            -80



            -90


            Center 315 MHz                             1 ms/




   Date: 27.SEP.2018              18:17:05




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                                              Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                                           Page 12 of 32


c c I s                                                                              Report No: CCISE180910201

Test Plots:
Product Name:               keyless transmitter                      Product Model:             RT—CY33B
Test By:                   Carey                                     Test mode:                 Tx mode

Test Frequency:            315 MHz                                   Polarization:              Vertical

Test Voltage:               DC 3V                                    Environment:               Temp: 24°C      Huni: 57%


120Level (dBuVi/m)

110


     90


     70


     50


     30




      G314      314.2            314.5                         315                                                      316
                                                        Frequency (MHz)

                              Read&ntenna           Cable Preamp                      Limit          Over
                   Freq      Level Factor            Loss Factor           Level       Line         Limit Remark

                    MHz         dBu¥       dB/m          dB          dB dBu¥/m dBu¥/m                      dB

      1       314.996        39.36       13.92        2. 99      8.00;     BG. 27 _———cceceulccl


Remark:
1.    _Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE18091012
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 13 of 32


c c I s                                                                             Report No: CCISE180910201



Product Name:              keyless transmitter                     Product Model:              RT—CY33B

Test By:                  Carey                                    Test mode:                  Tx mode
Test Frequency:           315 MHz                                  Polarization:               Horizontal

Test Voltage:              DC 3V                                   Environment:                Temp: 24°C     Huni: 57%


120Level (dBuVim)

110


 90


 70


 50


 30




      314     314.2            314.5                         315                                                     316
                                                      Frequency (MHz)


                             Read&ntenna           Cable Preamp                      Limit          Over
                  Freq      Level Factor            Loss Factor           Level       Line         Limit Remark

                   MHz         dBu¥      dB/m           dB          dB dBu¥/m dBu¥/m                     dB

      1      314.998        58.81       13.92        2. 99      0.00,     h. T2 ————__—j__A_2ee


Remark:
1.   _Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE18091012
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 14 of 32


                                                                              Report No: CCISE180910201

6.2.2    Spurious Emissions
                                           Below 1GHz (30MHz-1000MHz)
                                                         Peak value
                 Read        Antenna      Cable       Preamp
Frequency                                                         Level   Limit Line    Over Limit
                 Level        Factor      Loss         Factor                                        polarization
  (MHz)                                                        (dBuV/m)   (dBuV/m)        (dB)
               (dBuV/m)       (dB/m)       (dB)         (dB)
  631.688        16.79         19.59      3.89          0.00     40.27     75.62           -35.35      Vertical
  945.440        16.36           22.39     4.16        0.00       42.91    75.62           -32.71      Vertical
  631.688        16.90           19.59     3.89        0.00       40.38    75.62           -35.24    Horizontoal
  945.440        18.14           22.39     4.16        0.00       44.69    75.62           -30.93    Horizontoal
                                                       Average value
  Frequency            Level             Duty cycle       Average value          Limit Line
                                                                                                     Polarization
    (MHz)            (dBuV/m)              factor           (dBuV/m)             (dBuV/m)
    631.688              40.27             -10.26             30.01                55.62               Vertical
    945.440              42.91             -10.26             32.65                55.62               Vertical
    631.688              40.38             -10.26             30.12                55.62             Horizontoal
    945.440              44.69             -10.26             34.43                55.62             Horizontoal
Remark: Average value=Peak value + Duty Cycle Factor.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 15 of 32


CCIS                                                                                    Report No: CCISE180910201

Test Plots:
Product Name:               keyless transmitter                       Product Model:             RT—CY33B
Test By:                    Carey                                     Test mode:                Tx mode

Test Frequency:             30 MHz ~ 1 GHz                            Polarization:             Vertical

Test Voltage:               DC 3V                                     Environment:              Temp: 24°C      Huni: 57%


120|_e\'el (dBuVim)

110


     90

                                                                Fundamental signal
     70

                                                                                                     FCC PART1S CLAS$ B
                                                                                                                          {



      G30              50                     100                   200                              500                  1000
                                                          Frequency (MHz)
                              Readintenna             Cable Preamp                        Limit        Over
                   Freq      Level Factor               Loss Factor           Level        Line       Limit Remark

            """"""WBz dBuv                 dB/m —          dB _ dB dBu¥/m dBu¥/m                            dB _            o
      1        §5.221         I17.86      13.17        1.36         0.00      32.39       40.00 —7.61 QP
      2        92.462         16.69       10.44        2.03         0.00      29.16       43.50 —14.34 QP
      3       120.699         16.18       10.09        2.18         0.00      28.45       43.50 —15.05 qP
      4       457.507         17.37       16.32        3.26         0.00      36.95       46.00 —9.05 QP
      5       631.688         16.7T9      19.59        3.89         0.00      40.27       46.00 —5.73 Peak
      6       945.440         16.36       22.39        4.16         0.00      42.91       46.00 —3.09 Peak

Remark:
1.    Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.    The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE18091012
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 16 of 32


CCIS                                                                                    Report No: CCISE180910201


Product Name:               keyless transmitter                       Product Model:             RT—CY33B

Test By:                    Carey                                     Test mode:                Tx mode
Test Frequency:             30 MHz ~ 1 GHz                            Polarization:              Horizontal

Test Voltage:               DC 3V                                     Environment:              Temp: 24°C      Huni: 57%


120Level (dBuVim)

110

                                                                Fundamental signal

     90


     70

                                                                                                     FCC PART15 CLASS$ B
     50                                                                                                                 7
                                              '__.—._J'

                       1     2            q
     30 e                                 s



     10

          30           50                     100                   200                              500               1000
                                      L                   Frequency (MHz)
                               Readintenna            Cable Preamp                       Limit        Over
                    Freq      Level Factor              Loss Factor          Level         Line      Linmit Remark

               """WHz dBu¥y dB/m — dB — dB dBu¥/m dBu¥/m                                                      dB
      1          48.843       16.45       14.01        1. 27       0.00      31.73       40.00 —8.27 QP
      2          59.441       16.36       12.49        1. 38       0.00      30.23       40.00 —9.77 qP
      3          86. 200      18.63        9. 30       1. 91       0.00      29.84       40.00 —10.16 QP
      4         §17.248       17.43       17.68        3. T1       0.00      38.82       46.00 —7.18 qP
      5         631.688       16.90       19.59        3. 89       0.00      40.38       46.00 —5.62 Peak
      6         945.440       18.14       22.39        4.16        0.00      44.69       46.00 —1.31 Peak

Remark:
1.    Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.    The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE18091012
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 17 of 32


CCIS                                                                                   Report No: CCISE180910201



Product Name:               keyless transmitter                      Product Model:             RT—CY33B
Test By:                    Carey                                    Test mode:                Tx mode

Test Frequency:             1 GHz ~ 5 GHz                            Polarization:             Vertical

Test Voltage:               DC 3V                                    Environment:              Temp: 24°C         Huni: 57%

 80I.evt—:‘l (dBuVim)
                                                                                                           FCC PART 15 (PK)
 70

60
                                                                                                           FCC PART 15 (AV)
 50
                                      %                                   z       6       7
40                     1                            Cpastnement           1
 SOM


 20

 10


     01000      1200             1500                 2000                                                               5000
                                     L                 Frequency (MHz)
                              Read&ntenna            Cable Preamp                        Limit       Over
                   Freq      Level Factor              Loss Factor            Level       Line      Limit Remark

           """NHz dBuvy dB/m — db — dB dBuV/m dBu¥/m — dB —
      1      1258. 788       45.40        24.51        3.41       41.05       34.72      74.00     —39.28       Peak
      2      1574.380        48.23        25.40        3.82       41.03       38.64      74.00     —35.36       Peak
      3      1888. 396       45.28        26.16        4.22       41.41       36.71      74.00     —37.29       Peak
      4      2203.912        44.72        26.93        4.50       41.68       37.17      74.00     —36.83       Peak
      5      2518.887        44.86        27.65        4.85       41.90       38.31      74.00     —35.69       Peak
      6      2837.478        46.31        28.30        5.18       41.63       41.05      74.00     —32.95       Peak
      T      3150.399        44.T9        28.70        5.40       41.43       40.38      74.00     —33.62       Peak

Remark:
1.    Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.    The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE18091012
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 18 of 32


CCIS                                                                                    Report No: CCISE180910201


Product Name:               keyless transmitter                       Product Model:             RT—CY33B

Test By:                    Carey                                     Test mode:                Tx mode
Test Frequency:             1 GHz ~ 5 GHz                             Polarization:              Horizontal

Test Voltage:               DC 3V                                     Environment:              Temp: 24°C         Huni: 57%


 83 0l.evel (dBuVim)
                                                                                                            FCC PART 15 (PK)
 70

 60
                                                                                                            FCC PART 15 (AV)
 50                                                                                6


 40                     3                 2                                                TM

 30W



 20

 10


      1000       1200            1500                  2000                                                               5000
                                      _                  Frequency (MHz)
                               Read&ntenna             Cable Preamp                      Limit        Over
                   Freq       Level Factor              Loss Factor          Level        Line       Linmit Remark

           """"NHz dBu¥y dB/m — dB _ dB dBu¥/m dBu¥/m                                                       dB —
      1      1258. 788        45.58           24.51     3.41     41.05       34.90        74.00     —39.10       Peak
      2      1574.380         48.26           25.40     3.82     41.03       38.67        74.00     —35.33       Peak
      3      1888. 396        45.53           26.16     4.22     41.41       36.96        74.00     —37.04       Peak
      4      2203.912         46.73           26.93     4.50     41.68       39.18        74.00     —34.82       Peak
      5      2518.887         48.46           27.65     4.85     41.90       41.91        74.00     —32.09       Peak
      6      2837.478         52.08           28. 30    5.18     41.63       46.82        74.00     —27.18       Peak
      3      3150.399         45.64           28. 70    5.40     41.453      41.23        74.00     —32.77       Peak

Remark:
1.    Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.    The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE18091012
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                           Page 19 of 32


                                                                               Report No: CCISE180910201

6.3 20dB Bandwidth
        Test Requirement:                FCC Part15 C Section 15.231 (c)
                                         RSS-210 Annex A Section A.1.3
        Test Method:                     ANSI C63.10:2013
        Receiver setup:                  RBW=1kHz, VBW=3kHz, detector: Peak
        Limit:                           The bandwidth of the emission shall be no wider than 0.25% of the center
                                         frequency for devices operating above 70 MHz and below 900 MHz. For
                                         devices operating above 900 MHz, the emission shall be no wider than
                                         0.5% of the center frequency. Bandwidth is determined at the points 20
                                         dB down from the modulated carrier.
        Test Procedure:                  1. According to the follow Test-setup, keep the relative position between
                                             the artificial antenna and the EUT.
                                         2. Set the EUT to proper test channel.
                                         3. Max hold the radiated emissions, mark the peak power frequency
                                             point and the -20dB upper and lower frequency points.
                                         4. Read 20dB bandwidth.
        Test setup:




        Test Instruments:                Refer to section 5.7 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
  20dB bandwidth (MHz)                 Limit (MHz)              99% Occupy Bandwidth (MHz)            Results
            0.019                         0.7875                            0.106                     Passed

Note: 20dB bandwidth Limit= Fundamental frequency×0.25%=315×0.25%=0.7875MHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 20 of 32


                                                                                                            Report No: CCISE180910201

Test plot as follows:
                                                                   20dB Bandwidth
                                                                               * RBW   1 kHz    Delta 1 [T1 ]
                                                                               * VBW   3 kHz               -0.28 dB
                           Ref    5 dBm               * Att   10 dB                SWT 500 ms       19.000000000 kHz

                                 Offset    5 dB                                                 Marker 1 [T1 ]
                           0                                                                              -36.00 dBm
                                                                                                   314.991000000 MHz   A


                    1 PK   -10
                    MAXH            D1 -14.54 dBm
                                                                                                                       LVL
                           -20



                           -30
                                                                       1       1
                                          D2 -34.54 dBm

                           -40



                           -50
                                                                                                                       3DB
                                                                                                                       AC


                           -60



                           -70



                           -80



                           -90


                           Center 315 MHz                             50 kHz/                           Span 500 kHz




                    Date: 27.SEP.2018             20:40:08




                                                          99% Occupy Bandwidth
                                                                               * RBW   1 kHz    Marker 1 [T1 ]
                                                                                   VBW 3 kHz              -16.81 dBm
                           Ref    5 dBm                Att    15 dB                SWT 500 ms      315.000000000 MHz

                                 Offset    5 dB                                                 OBW106.000000000 kHz
                           0                                                                    Temp 1 [T1 OBW]
                                                                                                          -51.07 dBm   A

                                                                                                   314.943000000 MHz
                    1 PK   -10
                                                                                                Temp 2 [T1 OBW]
                    MAXH                                                   1
                                                                                                          -49.60 dBm LVL

                           -20                                                                     315.049000000 MHz




                           -30



                           -40


                                                                                       T2
                                                              T1
                           -50
                                                                                                                       3DB
                                                                                                                       AC


                           -60



                           -70



                           -80



                           -90


                           Center 315 MHz                             50 kHz/                           Span 500 kHz




                    Date: 30.SEP.2018             20:46:56




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                 Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                 Page 21 of 32


                                                                              Report No: CCISE180910201

6.4 Duration Time
                                         FCC Part15 C Section 15.231 (a1)
        Test Requirement:
                                         RSS-210 Annex A Section A.1.1 (a)
        Test Method:                     ANSI C63.10: 2013
        Receiver setup:                  RBW=1MHz, VBW=1MHz, span=0Hz, detector: Peak
        Limit:                           Not more than 5 seconds
        Test mode:                       Transmitting mode
        Test Procedure:                  1. According to the follow Test-setup, keep the relative position between
                                            the artificial antenna and the EUT.
                                         2. Set the EUT to proper test channel.
                                         3. Single scan the transmission, and read the transmission time.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data
         Duration time (second)                        Limit (second)                        Result
                 1.184                                     <5.0                               Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 22 of 32


                                                                                                       Report No: CCISE180910201

Test plot as follows:
                                                                        RBW 1 MHz          Delta 2 [T1 ]
                                                                       * VBW   1 MHz                   0.26 dB
                             Ref    5 dBm           * Att   10 dB       SWT 8 s                    5.000000 s

                                   Offset   5 dB                                           Marker 1 [T1 ]
                             0                                                                       -69.76 dBm
                                                                                                 544.000000 ms    A
                                                                                                                  SGL
                                                                                           Delta 1 [T1 ]
                    1 PK *   -10
                                                                                                       0.09 dB
                    CLRWR
                                                                                                   1.184000 s     LVL
                             -20



                             -30



                             -40



                             -50
                                                                                                                  3DB



                             -60


                                   1           1                                       2
                             -70



                             -80



                             -90


                             Center 315 MHz                         800 ms/




                    Date: 7.NOV.2018           09:24:28




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                            Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                            Page 23 of 32


                                                                                   Report No: CCISE180910201

6.5 Frequency Stability
       Test Requirement:                   RSS-GEN Section 8.11
       Test Method:                        RSS-GEN Section 6.11
       Limit:                              Kept within at least the central 80% of its permitted operating frequency band.

       Test setup:




       Test procedure:                     1.   The EUT is installed in an environment test chamber with external
                                                power source.
                                           2.   Set the chamber to operate at 50 centigrade and external power
                                                source to output at nominal voltage of EUT.
                                           3.   A sufficient stabilization period at each temperature is used prior to
                                                each frequency measurement.
                                           4.   When temperature is stabled, measure the frequency stability.
                                           5.   The test shall be performed under -20 to 50 centigrade and 85 to
                                                115 percent of the nominal voltage. Change setting of chamber
                                                and external power source to complete all conditions.
       Test Instruments:                   Refer to section 5.7 for details
       Test mode:                          Unmodulated carrier is not available, test at modulated carrier mode.
       Test results:                       Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                   Project No.: CCISE18091012
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                      Page 24 of 32


CCIS                                                                                            Report No: CCISE180910201

Measurement Data:
Voltage vs. Frequency Stability

       Temp(.c')l'est condltlocznage(ac)                    Measurement Frequency (MHz)                        Limit (MHz)

                                      3.2V                                    315.0
           20                         3.0V                                    314.9                             281 ~ 449
                                      2.5V                                    314.8
  Note: EUT stops working when the supply voltage is lower than DC 2.5V ..

Temperature vs. Frequency Stability
                  Test conditions
                                Temp(C)                                   Frequency(MHz)                       Limit (MHz)
      Voltage(de)

                                      20                                      315.0

           3.0V                       20                                      314.9                             281 ~ 449

                                      50                                      314.8


Test plot as follows :
                     @_                                              «raw n kn     marker i iri a
                                                                     «vew n ue               —re.ss can
                          mee s gen               mss    20 as        sur seo me      215.000000000 imz




                                                                 so knz                    span 500 knz




                     Date: 20.929.2018       19:d43:11




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                              Project No.: CCISE18091012
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                              Page 25 of 32



Document Created: 2018-11-16 11:54:03
Document Modified: 2018-11-16 11:54:03

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC