MPE

FCC ID: 2AOKB-T8113

RF Exposure Info

Download: PDF
FCCID_4455690

                                                                                               REPORT No.:SZ19070443S01




                                            RF EXPOSURE
                         EVALUATION REPORT

                    APPLICANT                             : Anker Innovations Limited

                    PRODUCT NAME                          : eufyCam 2C

                    MODEL NAME                            : T8113

                    BRAND NAME                            : eufy SECURITY

                    FCC ID                                : 2AOKB-T8113
                                                               47CFR 2.1091
                    STANDARD(S)                           :
                                                               KDB 447498
                    RECEIPT DATE                          : 2019-08-12

                    TEST DATE                             : 2019-09-16

                    ISSUE DATE                            : 2019-09-16




                                                                       Edited by:
                                                                                               Gan yueming (Rapporteur)


                                                                       Approved by:
                                                                                               Peng Huarui (Supervisor )


NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.


 MORLAB
                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                                  Page1of 9


                                                                                           REPORT No.:SZ19070443S01

                                                         DIRECTORY

1. Technical Information ········································································································ 4
1.1    Applicant and Manufacturer Information ····································································· 4
1.2    Equipment under Test (EUT) Description ···································································· 4
1.3    Identification of all used EUT ························································································ 5
1.4    Applied Reference Documents ····················································································· 5
2. Device Category and RF Exposure Limit········································································ 6
3. RF Output Power ················································································································ 7
4. RF Exposure Evaluation ··································································································· 8
Annex A General Information ································································································· 9




MORLAB
                     SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                     FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                     Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page2of 9


                                                                                  REPORT No.:SZ19070443S01
                                                        Change history
    Version                                        Date                                     Reason of changed
      1.0                                     2019-09-16                                                 Original




MORLAB
            SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555       Fax: 86-755-36698525
            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn       E-mail: service@morlab.cn

                                                                                                                                    Page3of 9


                                                                                       REPORT No.:SZ19070443S01
1. Technical Information
   Note: Provide by manufacturer.

1.1 Applicant and Manufacturer Information

 Applicant:                               Anker Innovations Limited
                                          Room 1318-19,Hollywood Plaza,610 Nathan Road,Mongkok,Kowloon,
 Applicant Address:
                                          Hong Kong
 Manufacturer:                            Anker Innovations Limited
                                          Room 1318-19,Hollywood Plaza,610 Nathan Road,Mongkok,Kowloon,
 Manufacturer Address:
                                          Hong Kong


1.2 Equipment under Test (EUT) Description

 EUT Name:                               eufyCam 2C
 Hardware Version:                       V3
 Software Version:                       V1.1.3

 Frequency Bands:                        WLAN 2.4GHz: 2412 MHz ~2462 MHz

                                         802.11b: DSSS
 Modulation Mode:
                                         802.11g/n-HT20: OFDM
 Antenna Type:                           FPC antenna
 Antenna Gain:                           0 dBi




MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page4of 9


                                                                                        REPORT No.:SZ19070443S01
1.3 Identification of all used EUT
The EUT identity consists of numerical and letter characters, the letter character indicates the test
sample, and the following two numerical characters indicate the software version of the test sample.


        EUT Identity                               Hardware Version                                    Software Version
             1#                                                  V3                                            V1.1.3




1.4 Applied Reference Documents
Leading reference documents for testing:
                                                                                                                           Method
No.           Identity                                                 Document Title                                   determination
                                                                                                                          /Remark
                                              Radio Frequency Radiation Exposure Evaluation:
 1         47 CFR§2.1091                                                                                                  No deviation
                                              mobile devices
 2     KDB 447498 D01v06                      General RF Exposure Guidance                                                No deviation




MORLAB
                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                      Page5of 9


                                                                                        REPORT No.:SZ19070443S01
2. Device Category and RF Exposure Limit
Per user manual, Based on 47CFR 2.1091, this device belongs to mobile device category with
General Population/Uncontrolled exposure.
Mobile Devices:
47CFR 2.1091(b)
For purposes of this section, a mobile device is defined as a transmitting device designed to be
used in other than fixed locations and to generally be used in such a way that a separation distance
of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s)
and the body of the user or nearby persons. In this context, the term “fixed location” means that the
device is physically secured at one location and is not able to be easily moved to another location.
Transmitting devices designed to be used by consumers or workers that can be easily re-located,
such as wireless devices associated with a personal computer, are considered to be mobile devices
if they meet the 20 centimeter separation requirement.
GENERAL POPULATION / UNCONTROLLED EXPOSURE
The general population/uncontrolled exposure limits are applicable to situations in which the
general public may be exposed or in which persons who are exposed as a consequence of their
employment may not be made fully aware of the potential for exposure or cannot exercise control
over their exposure. Members of the general public would come under this category when exposure
is not employment-related; for example, in the case of a wireless transmitter that exposes persons
in its vicinity. Warning labels placed on low-power consumer devices such as cellular telephones
are not considered sufficient to allow the device to be considered under the occupational/controlled
category, and the general population/uncontrolled exposure limits apply to these devices.
                         TABLE 1—LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

      Frequency                 Electric field                       Magnetic field                Power               Averaging
        range                     strength                             strength                   density                time
        (MHz)                       (V/m)                               (A/m)                    (mW/cm2)              (minutes)

                      (B) Limits for General Population/Uncontrolled Exposure

       0.3-1.34                         614                                   1.63                   *(100)                   30

       1.34-30                         824/f                                 2.19/f                *(180/f2)                  30

        30-300                         27.5                                  0.073                     0.2                    30

       300-1500                            -                                     -                  f/1500                    30

    1500-100,000                           -                                     -                     1.0                    30
    f = frequency in MHz* = Plane-wave equivalent power density




MORLAB
                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                      Page6of 9


                                                                                      REPORT No.:SZ19070443S01
3. RF Output Power
<WLAN 2.4GHz>
                                                                                     Average
                                                                  Frequency                                  Tune-up                Duty
                        Mode                  Channel                                power
                                                                     (MHz)                                   Power               Cycle %
                                                                                     (dBm)
                                                CH 1                  2412            17.65                   18.0
                      802.11b
                                                CH 6                  2437            17.78                   18.0                 99.28
                       1Mbps
                                               CH 11                  2462            17.92                   18.0
 2.4GHz WLAN
                                                CH 1                  2412            16.35                   17.0
                      802.11g
                                                CH 6                  2437            16.42                   17.0                 95.49
                       6Mbps
                                               CH 11                  2462            16.51                   17.0
                                                CH 1                  2412            16.47                   17.0
                 802.11n-HT20
                                                CH 6                  2437            16.38                   17.0                 95.13
                        MCS0
                                               CH 11                  2462            16.52                   17.0




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                    Tel: 86-755-36698555      Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn      E-mail: service@morlab.cn

                                                                                                                                       Page7of 9


                                                                                           REPORT No.:SZ19070443S01

4. RF Exposure Evaluation
    Standalone transmission evaluation:
                                                      Maximum                   Antenna                            Power              Limit for
                           Frequency                                                             EIRP
        Bands                                     Tune-up Power                    Gain                            density                 MPE
                              (MHz)                                                              (mW)
                                                         (dBm)                     (dBi)                          (mW/cm²)           (mW/cm²)
    WLAN 2.4GHz                2462                       18.0                         0          63.1             0.012                    1.0
Note:
1. According to KDB 447498, SAR test exclusion conditions are based on source-based time-averaged
     maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up
     tolerance, and the minimum test separation distance required for the exposure conditions.
2. MPE calculate method
                       Power Density = EIRP/4πR²
    Where: EIRP = P+G
          P = Output Power (dBm)
          G = Antenna Gain (dBi)
          R = Separation Distance (20cm)


 Simultaneous transmission evaluation:
This device only incorporates a WLAN 2.4G transmitter, Therefore simultaneous SAR evaluation is
not required.




MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                       Tel: 86-755-36698555     Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China       Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                           Page8of 9


                                                                                     REPORT No.:SZ19070443S01
Annex A General Information
1. Identification of the Responsible Testing Laboratory
                                                    Shenzhen Morlab Communications Technology Co., Ltd.
  Laboratory Name:
                                                    Morlab Laboratory
                                                    FL.3, Building A, FeiYang Science Park, No.8 LongChang Road,
  Laboratory Address:                               Block 67, BaoAn District, ShenZhen, GuangDong Province, P.
                                                    R. China
  Telephone:                                        +86 755 36698555
  Facsimile:                                        +86 755 36698525


2. Identification of the Responsible Testing Location
                                                    Shenzhen Morlab Communications Technology Co., Ltd.
  Name:
                                                    Morlab Laboratory
                                                    FL.3, Building A, FeiYang Science Park, No.8 LongChang Road,
  Address:                                          Block 67, BaoAn District, ShenZhen, GuangDong Province, P.
                                                    R. China




                                                        END OF REPORT



MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page9of 9



Document Created: 2019-09-18 11:32:07
Document Modified: 2019-09-18 11:32:07

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC