Test report

FCC ID: 2AOJULP-006D

Test Report

Download: PDF
FCCID_4288208

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE180913007

1        Cover Page

                                      FCC REPORT
Applicant:                                 Shenzhen Light Pioneer Technology Co., Ltd

Address of Applicant:                      10th Floor, Block B, Guanghao International Centre, Longhua
                                           District, Shenzhen, China
Equipment Under Test (EUT)

    Product Name:                          Handheld RFID Reader

    Model No.:                             LP-006D

    Trade mark:                            LightPioneer

FCC ID:                                    2AOJULP-006D

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    26 Sep., 2018

Date of Test:                              26 Sep., 2018 to 18 Apr., 2019

Date of report issued:                     18 Apr., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE180913007

2      Version
      Version No.                            Date                                  Description
             00                         18 Apr., 2019                                Original




    Tested by:                                                           Date:          18 Apr., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          18 Apr., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1809130
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 2 of 18


                                                                                                                            Report No: CCISE180913007

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.9    LABORATORY LOCATION ................................................................................................................................................... 6
    5.10      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1809130
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 18


                                                                              Report No: CCISE180913007

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1809130
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


                                                                              Report No: CCISE180913007

5      General Information
5.1 Client Information
        Applicant:                              Shenzhen Light Pioneer Technology Co., Ltd
        Address:                                10th Floor, Block B, Guanghao International Centre, Longhua
                                                District, Shenzhen, China
        Manufacturer:                           Shenzhen Light Pioneer Technology Co., Ltd
        Address:                                10th Floor, Block B, Guanghao International Centre, Longhua
                                                District, Shenzhen, China

5.2 General Description of E.U.T.
        Product Name:                           Handheld RFID Reader
        Model No.:                              LP-006D
        Power supply:                           Rechargeable Li-ion Battery DC3.7V-4500mAh
                                                Model: GME10C-050200FCu
        AC adapter :                            Input: AC100-240V, 50/60Hz, 0.28A
                                                Output: DC 5.0V, 2A
        Test Sample Condition:                  The test samples were provided in good working order with no
                                                visible defects.

5.3 Test Mode
           Operating mode               Detail description
              PC mode                   Keep the EUT in Downloading mode(Worst case)
    Charging+Recording mode             Keep the EUT in Charging+Recording mode
      Charging+Playing mode             Keep the EUT in Charging+Playing mode
              FM mode                   Keep the EUT in FM receiver mode
            GPS mode                  Keep the EUT in GPS receiver mode
 The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
 vertical polarities were performed. During the test, each emission was maximized by: having the EUT
 continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
 typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
 varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case
 are shown in Test Results of the following pages.

5.4 Measurement Uncertainty
                    Parameters                                            Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                    ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                    ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                   ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                     ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                    ±2.88 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1809130
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                          Page 5 of 18


CCIS                                                                            Report No: CCISE180913007

5.5 Description of Support Units
      Manufacturer                Description                 Model          Serial Number           FCC ID/DoC

           DELL                        PC                 OPTIPLEX745               N/A                  DoC
           DELL                    MONITOR                   E178FPC                N/A                  DoC
           DELL                   KEYBOARD                   SK—8115                N/A                  DoC
           DELL                     MOUSE                    MOCSUO                 N/A                  DoC
        LENOVO                       Laptop                   SL510              2B47A65                 DoC

5.6 Related Submittal(s) / Grant (s)
       This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
        Cable Type                     Description                 Length           From                  To
   Detached USB Cable                   Unshielded                  1.0m             EUT              PC/Adapter
   Detached USB Cable                   Unshielded                  1.0m             EUT               Adapter

5.8 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
       ®   FCC — Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
       ®    IC — Registration No.: 10106A—1
       The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A—1.
       ® CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of testing.
       The Registration No. is CNAS L6048.
       ® A2LA — Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la. org/scopepdf/4346—0 1 .pdf

5.9 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bac‘an District, Shenzhen, Guangdong, China
        Tel: +86—755—23118282, Fax: +86—755—23116366
       Email: info@ccis—cb.com, Website: http//www.ccis—cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1809130
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                             Page 6 of 18


                                                                                    Report No: CCISE180913007

5.10 Test Instruments list
 Radiated Emission:
                                                                                          Cal. Date      Cal. Due date
    Test Equipment            Manufacturer            Model No.           Serial No.
                                                                                         (mm-dd-yy)       (mm-dd-yy)
        3m SAC                  SAEMC                 9m*6m*6m                966        07-22-2017       07-21-2020
     Loop Antenna            SCHWARZBECK             FMZB1519B              00044        03-16-2018       03-15-2019
   BiConiLog Antenna         SCHWARZBECK              VULB9163                497        03-16-2018       03-15-2019
     Horn Antenna            SCHWARZBECK             BBHA9120D                916        03-16-2018       03-15-2019
     Horn Antenna            SCHWARZBECK             BBHA9120D               1805        06-22-2017       06-21-2020
     Horn Antenna            SCHWARZBECK             BBHA 9170           BBHA9170582     11-21-2018       11-20-2019
   EMI Test Software              AUDIX                   E3                        Version: 6.110919b
                                                                                        03-07-2018        03-06-2019
      Pre-amplifier                 HP                  8447D            2944A09358
                                                                                        03-07-2019        03-06-2020
                                                                                        03-07-2018        03-06-2019
      Pre-amplifier                 CD                PAP-1G18              11804
                                                                                        03-07-2019        03-06-2020
                                                                                        03-07-2018        03-06-2019
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454
                                                                                        03-07-2019        03-06-2020
   Spectrum analyzer        Rohde & Schwarz             FSP40              100363       11-21-2018        11-20-2019
                                                                                         03-07-2018       03-06-2019
   EMI Test Receiver         Rohde & Schwarz            ESRP7              101070
                                                                                         03-07-2019       03-06-2020
                                                                                         03-07-2018       03-06-2019
          Cable                   ZDECL             Z108-NJ-NJ-81          1608458
                                                                                         03-07-2019       03-06-2020
                                                                                         03-07-2018       03-06-2019
          Cable               MICRO-COAX              MFR64639            K10742-5
                                                                                         03-07-2019       03-06-2020
                                                                                         03-07-2018       03-06-2019
          Cable                  SUHNER             SUCOFLEX100           58193/4PE
                                                                                         03-07-2019       03-06-2020


 Conducted Emission:
                                                                                          Cal. Date     Cal. Due date
    Test Equipment            Manufacturer            Model No.           Serial No.
                                                                                        (mm-dd-yy)       (mm-dd-yy)
                                                                                         03-07-2018      03-06-2019
   EMI Test Receiver        Rohde & Schwarz              ESCI              101189
                                                                                         03-07-2019      03-06-2020
                                                                                         03-07-2018      03-06-2019
      Pulse Limiter          SCHWARZBECK             OSRAM 2306             9731
                                                                                         03-07-2019      03-06-2020
                                                                                         03-19-2018      03-18-2019
          LISN                    CHASE                MN2050D              1447
                                                                                         03-19-2019      03-18-2020
          LISN              Rohde & Schwarz            ESH3-Z5           8438621/010     07-21-2018      07-20-2019
                                                                                         03-07-2018      03-06-2019
          Cable                     HP                  10503A               N/A
                                                                                         03-07-2019      03-06-2020
   EMI Test Software              AUDIX                   E3                         Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1809130
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                              Page 7 of 18


                                                                              Report No: CCISE180913007

6      Test results and Measurement Data
6.1 Conducted Emission
       Test Requirement:                FCC Part 15 B Section 15.107
       Test Method:                     ANSI C63.4:2014
       Test Frequency Range:            150kHz to 30MHz
       Class / Severity:                Class B                  Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                        Limit (dBµV)
                                          Frequency range (MHz)
                                                                          Quasi-peak                Average
                                                 0.15-0.5                   66 to 56*               56 to 46*
                                                   0.5-5                       56                      46
                                                  0.5-30                       60                      50
                                        * Decreases with the logarithm of the frequency.
       Test setup:




       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                           line impedance stabilization network(L.I.S.N.). The provide a
                                           50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through a
                                           LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                           termination. (Please refers to the block diagram of the test setup and
                                           photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                           interference. In order to find the maximum emission, the relative
                                           positions of equipment and all of the interface cables must be changed
                                           according to ANSI C63.4: 2014 on conducted measurement.
       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1809130
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 18


c c I s                                                                                   Report No: CCISE180913007

Measurement data:
 Product name:                     Handheld RFID Reader            Product model:                LP—006D

 Test by:                          Yaro                           Test mode:                     PC mode

 Test frequency:                   150 kHz ~ 30 MHz                Phase:                        Line

 Test voltage:                     AC 120 V/60 Hz                  Environment:                  Temp: 22.5°C            Huni: 55%



                 gp Level (dBuy)

                 70
                 60                                                                                     FCC CLASS—8 OP
                 50\
                                                                                                        FCC CLASS—B AV


                      *                                                    11
                                                                “. ‘ H “ wn   ..
                ::‘{\V.-,‘     1A                    u‘ '"\M‘ t
                                                                                      U Tt
                 20           t tbf\""%“ |                                          \ A   |U |
                                                                                             |                      \\_

                 10

                      A5 2                    5        1          2               5              10            20        30
            Frace: 97                                        Frequency (MHz)

            Remark
                                              Read   LISN    Cable                Limit        Over
                               Freq          Level Factor     Loss     Level       Line       Limit Remark



               1              0.158          30.72    0.17   10.77     41.66      65.56      —23.90       QP
               2              0.162          27.06    0.17   10.77     38.00      5§5.34     —17.34       Average
               3              0.904          30.88    0.13   10.84     41.85      56.00      —14.15       QP
               4              0.904          28.33    0.13   10.84     39.30      46.00       —6.70       Average
               5              1.544          34.16    0.14   10.93     45.23      56.00      —10.77       QP
               6              1.552          30.57    0.14   10.93     41.64      46.00       —4.36       Average
               T              2.201          32.89    0.15   10.95     43.99      56.00      —12.01       QP
               8              2.201          27.92    0.15   10.95     39.02      46.00       —6.98       Average
               9              2.978          30.78    0.16   10.92     41.86      56.00      —14.14       QP
              10             10.233          23.60    0.32   10.94     34.86      50.00      —15.14       Average
              11             19.532          29.68    0.27   10.93     40.88      60.00      —19.12       qP
              12             23.140          24.97    0.31   10.89     36.17      50.00      —13.83       Average

 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                          Project No.: CCISE1809130
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                          Page 9 of 18


CCIS                                                                                                     Report No: CCISE180913007


 Product name:                      Handheld RFID Reader                       Product model:                          LP—006D

Test by:                            Yaro                                       Test mode:                              PC mode

Test frequency:                     150 kHz ~ 30 MHz                           Phase:                                  Neutral

Test voltage:                       AC 120 V/60 Hz                             Environment:                            Temp: 22.5°C            Huni: 55%



                5 Level (dBuy)

                70

                so\                                                                                                           Fee cLass—8 oP
                50\\\                                                     &                                                   FCC CLA$5—B AV

                40)            t                           |        l'                I        ,‘                      (8s,               K
                  »|)\, \
                       A       II          it
                                                         CHaUnOT
                                                            \
                                                                 SA || ? NMubyt!
                                                                    l
                                                                           Om
                                                                               ;4 ‘        U        M              M         *
                                                                                                                                     |
                                                                                                                                    [ )
                                                                                                                                              N
                  20          Y ul\nfl                           \                                            M

                  10

                       15 2                       5        1                   2                     5                 10            20        30
            Trace:2%                                                    Frequency (MHz)


            Remark
                                                 Read    LISN       Cable                           Limnit         Over
                              Freq              Level Factor         Loss                 Level      Line         Limit Remark

                       """"""NHz                 dBu¥      dB                 dB           dBu¥y dBuy _                 db
              1             0. 258              25. 81   0.95       10.75                 37.51     51.51        —14.00          Average
              2             0. 899              31.68    0.97       10.84                 43.49     56.00        —12.51          qP
              3             0. 904              27.18    0.97       10.84                 38.99     46.00         —7.01          Average
              4             1.536               29.03    0.98       10.93                 40.94     46.00         —5.06          Average
              5             1.671               $3.32    0.98       10.94                 45.24     56.00        —10.76          qP
              6             2.178               28.26    0.98       10.95                 40.19     46.00         —5.81          Average
              T             2. 321              33.30    0.98       10.94                 45.22     56.00        —10.78          QP
              8             3. 584              33. 14   1.00       10.90                 45.04     56.00        —10.96          QP
              9            10. 125              30. 33   1.02       10.94                 42.29     60.00        —17.71          qP
             10            10. 508              27. 64   1.01       10.94                 39.59     50.00        —10.41          Average
             11            23.263               30.70    0.68       10.89                 42.27     60.00        —17.73          QP
             12            23.263               28.16    0.63       10.89                 39.73     50.00        —10.27          Average


 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                Project No.: CCISE1809130
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                   Page 10 of 18


                                                                         Report No: CCISE180913007

6.2 Radiated Emission
        Test Requirement:             FCC Part 15 B Section 15.109
        Test Method:                  ANSI C63.4:2014
        Test Frequency Range:         30MHz to 6000MHz
        Test site:                    Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                 Frequency       Detector        RBW      VBW           Remark
                                       30MHz-1GHz      Quasi-peak      120kHz   300kHz    Quasi-peak Value
                                                         Peak           1MHz     3MHz       Peak Value
                                       Above 1GHz
                                                         RMS            1MHz     3MHz      Average Value
        Limit:                               Frequency           Limit (dBuV/m @3m)          Remark
                                           30MHz-88MHz                    40.0           Quasi-peak Value
                                          88MHz-216MHz                    43.5           Quasi-peak Value
                                          216MHz-960MHz                   46.0           Quasi-peak Value
                                           960MHz-1GHz                    54.0           Quasi-peak Value
                                                                          54.0            Average Value
                                            Above 1GHz
                                                                          74.0             Peak Value
        Test setup:                   Below 1GHz




                                      Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE1809130
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                    Page 11 of 18


                                                                               Report No: CCISE180913007


        Test Procedure:                 1. The EUT was placed on the top of a rotating table 0.8 meters above
                                           the ground at a 3 meter semi-anechoic camber. The table was rotated
                                           360 degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and
                                           Specified Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of
                                           the EUT would be reported. Otherwise the emissions that did not have
                                           10dB margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
        Test Instruments:               Refer to section 5.9 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed
        Remark:                         All of the observed value above 6GHz ware the niose floor , which were
                                        no recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1809130
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


c c I s                                                                                              Report No: CCISE180913007

Measurement Data:
Below 1GHz:

 Product Name:               Handheld RFID Reader                                   Product model:           LP—006D

Test By:                     Yaro                                                  Test mode:                PC mode

Test Frequency:              30 MHz ~1 GHz                                          Polarization:            Vertical

Test Voltage:                AC 120/60Hz                                            Environment:             Temp: 24°C          Huni: 57%



              3 Level (dBuVim)


              70

              60
                                                                                                            FCC PART1S CLAS$ 8




                   30         50                 100                              200                       500             1000
                                                                         Frequency (MHz)


           Remark
                                     Readéntenna       Cable Preamp                                 Limit    Over
                           Freq     Level Factor         Loss Factor                       Level     Line   Limit Remark

                            MHz      dBu¥       dB/n                      dB        dB dBu¥/m dBu¥/m              dB

              1          36.637     43.17    12.08                       .11   29.93       26.43    40.00 —13.57 QP
                                                        > C ho No + ++




              2         103.442     41.16    11.91                        97   29.50       25.54    43.50 —17.96 qP
              3         137.420     55.45     8.25                        37   29.29       36.78    43.50 —6.72 qP
              4         196. 510    42.14    11.40                       .84   28.85       27.53    43.50 —15.97 QP
              5         480.528     52.80    16. 97                      .46   28.92       44.31    46.00 —1.69 QP
              6         T21.726     45.19    20.33                       .26   28.58       41.20    46.00 —4.80 QP


 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                 Project No.: CCISE1809130
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                  Page 13 of 18


c c I s                                                                                   Report No: CCISE180913007



 Product Name:                     Handheld RFID Reader                  Product model:           LP—006D

 Test By:                          Yaro                                 Test mode:                PC mode

 Test Frequency:                   30 MHz ~ 1 GHz                        Polarization:            Horizontal

 Test Voltage:                     AC 120/60Hz                           Environment:             Temp: 24°C      Huni: 57%



              80Level (dBuVim)


              70

              60
                                                                                                 FCC PART15 CLAS$ B
              50




                   30               50                100               200                      500             1000
                                                              Frequency (MHz)

            Remark
                                           Read&ntenna      Cable Preamp                 Limit    Over
                                 Freq     Level Factor        Loss Factor       Level     Line   Limit Remark

                        ~——      WNHz _ dBu¥        dB/m       dB       dB dBu¥/m dBu¥/mdb —
              1               102. 719    44.47     11.87    1.96   29.51       28.79    43.50   —14.71   QP
              2               171.393     48.59      9.46    2.66   29.04       31.67    43.50   —11.83   QP
              3               274.194     51.46     13.45    2.87   28.50       39.28    46.00    —6.72   9P
              4               308.913     §3.81     13.79    2.97   28.47       42.10    46.00    —3.90   QP
              5               377.259     45.79     15.11    3.09   28.68       35.31    46.00   —10.69   QP
              6               480.528     43.25     16.97    3.46   28.92       34.76    46.00   —11.24   QP


 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1809130
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                      Page 14 of 18


c c I s                                                                                  Report No: CCISE180913007

Above 1GHz:
 Product Name:               Handheld RFID Reader                       Product model:            LP—006D

 Test By:                    Yaro                                       Test mode:                PC mode

 Test Frequency:             1 GHz ~ 6 GHz                              Polarization:             Vertical

 Test Voltage:               AC 120/60Hz                                Environment:              Temp: 24°C         Huni: 57%



             so Level (dBuWVim)
                                                                                                    FCC PART 15 (PK)
             70

             60
                                                                                                    FCC PART 15 (AV)
             50                                                                                                      :

             40                                                  1
             30

             20

             10


                  1000   1200        1500            2000                                                    5000   6000
                                                            Frequency (MHz)


            Renark
                                     Readéntenna       Cable Preanp                     Limit     Over
                          Freq      Level Factor         Loss Factor          Level      Line    Limit Remark

                            NHz ~ dbuvy       db/m          dB          dB dBu¥/n dBu¥/m             db
              1      2333.810       49.36    26.90      4.63         41.85    39.04     74.00   —34.96    Peak
              2      2333.810       40.22    26.90      4.63         41.85    29.90     54.00   —24.10    Average
              3      4111.131       48.33    30.32      6.27         41.81    43.11     74.00   —30.89    Peak
              4       41i1.131      39.44    30.32      6.27         41.81    34.22     54.00   —19.78    Average
              5       5882.902      48.59    32.68      T.91         42.03    47.15     T4.00   —26.85    Peak
              6       5882.902      39.17    32.68      T.91         42.03    37.73     54.00   —16.27    Average


 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1809130
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                         Page 15 of 18


c c I s                                                                                                  Report No: CCISE180913007



 Product Name:                         Handheld RFID Reader                             Product model:            LP—006D

Test By:                               Yaro                                             Test mode:                PC mode

Test Frequency:                        1 GHz ~6 GHz                                     Polarization:             Horizontal

Test Voltage:                          AC 120/60Hz                                      Environment:              Temp: 24°C          Huni: 57%



                   8Olevel (dBuVim)
                                                                                                                   FCC PART 15 (PK)

                   70

                  60
                                                                                                                   FCC PART 15 (AV)

                   50




                             1000   1200       1500           2000                                                       5000    6000
                                                                             Frequency (MHz)


           Remark
                                               Readéntenna     Cable Preanp                             Linit     Over
                                     Freq     Level Factor       Loss Factor                   Level     Line    Limit Remark

                                      MHz      dBu¥    dB/m                   dB       dB dBu¥/m dBu¥/m             dB

                                2683.869      47.62   27.83                  .03   41.78       38.70    74.00   —35.30   Peak
                                                                —1— o o oc
             o omm co no +




                                2683.869      37.25   27.83                  .03   41.78       28.33    54.00   —25.67   Average
                                3980.656      49.11   30.24                        41.81       43.65    74.00   —30.35   Peak
                                3980.656      39.84   30.24                  .11   41.81        34.38   54.00   —19.62   Average
                                5226.T772     48.16   31.96                  .09   41.94       45.87    74.00   —28.13   Peak
                                §226.T72      39.43   31.96                  .09   41.94       36.54    54.00 —17.46 Average


 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                      Project No.: CCISE1809130
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                        Page 16 of 18



Document Created: 2019-05-15 10:13:33
Document Modified: 2019-05-15 10:13:33

© 2024 FCC.report