RF Exposure

FCC ID: 2AOIU-C00220

RF Exposure Info

Download: PDF
FCCID_4376608

 FCC ID: 2AOIU-C00220




                          FCC 47 CFR MPE REPORT




                                    Pelican Products, Inc.

                                          EMS Recharge

                                  Model Number: C00220

                                  FCC ID: 2AOIU-C00220




Prepared for:   Pelican Products, Inc.
                23215 Early Avenue, Torrance, California, 90505, United States


Prepared By:    EST Technology Co., Ltd.
                Chilingxiang, Qishantou, Santun, Houjie, Dongguan, Guangdong, China
                                   Tel: 86-769-83081888-808




                        Report Number:         ESTE-R1907002
                        Date of Test:          Jun. 25~Jul. 29, 2019
                        Date of Report:        Jul. 29, 2019




                EST Technology Co. ,Ltd         Report No. ESTE-R1907002   Page 1 of 11


  FCC ID: 2AOIU-C00220



Environmental evaluation and exposure limit according to FCC CFR 47 Part
1.1307(b), 1.1310

1. Limits for Maximum Permissible Exposure (MPE)




2. Test equipment

Equipment              Manufacturer Model No. Serial No.               Last Cal. Next Cal.
E-Magnetic field probe Narda        2304/03   M-0018                   June,29,18 1 Year
Broadband field meter Narda         ELT-400   N-0045                   June,29,18 1 Year

3. Test setup
A:
                                            15cm
                20 cm




                  EST Technology Co. ,Ltd   Report No. ESTE-R1907002        Page 2 of 11


 FCC ID: 2AOIU-C00220




B:




a. The test was performed on 360 degree turn table in anechoic chamber.
b. The probe was placed at 15 cm surrounding the device and 20 cm above the top of
the charger and the geometric centre of the probe, for test setup A.
c. Measure magnetic and electrical field strength at a distance 10cm to 1cm at 1cm
iteration, Which is between the edge of the charger and the edge of of probe, for test
setup B.
d. The highest emission level was recorded and compared with limit as soon as
measurement of each point; A, B, C, D, E were completed.
e. The EUT was measured according to the dictates of KDB680106D01v03; And
KDB Tracking Number 671578; TCB Workshop, October 2018, 5.2 RF Exposure
Procedures.




                 EST Technology Co. ,Ltd     Report No. ESTE-R1907002   Page 3 of 11


  FCC ID: 2AOIU-C00220

4. Equipment Approval Considerations
According to the item 5(b) of KDB 680106 D01 RF Exposure Wireless Charging App
v03.

1 Power transfer frequency is less that 1 MHz
  YES; the device operated in the frequency range from 110.5-205KHz.
2 Output power from each primary coil is less than or equal to 15 watts.
  YES; the maximum output power of the primary coil is 5W.
  The transfer system includes only single primary and secondary coils. This includes
3 charging systems that may have multiple primary coils and clients that are able to
  detect and allow coupling only between individual pairs of coils.
  YES; the transfer system includes only single primary and secondary coils.
4 Client device is placed directly in contact with the transmitter.
  YES; Client device is placed directly in contact with the transmitter.
  Mobile exposure conditions only (portable exposure conditions are not covered by
5
  this exclusion).
  No.
  The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the
6 top surface from all simultaneous transmitting coils are demonstrated to be less than
  50% of the MPE limit.
  YES; The EUT field strength levels are 50% x MPE limts.

5. Test Mode
                  Mode                                       Description
                                                              Full Load
     Charging mode with dummy load                            Half Load
                                                             Empty Load
All power supplies working mode have been tested, The worst is the internal battery
working mode, and only the worst results have been reported.




                  EST Technology Co. ,Ltd     Report No. ESTE-R1907002   Page 4 of 11


  FCC ID: 2AOIU-C00220

6. Test Result
Test Result for Test setup A:

E-Filed Strength at (15 cm from edges A,B,C,D, 20 cm from top E) surrounding the
EUT (V/m)
   Test Mode                      Full Load        Half Load      Empty Load
   Frequency range (kHz)                       110.5 to 205 kHz
   Position A(V/m)                  1.348           1.211            1.171
   Position B(V/m)                  1.322           1.212            1.168
   Position C(V/m)                  1.344           1.152            1.121
   Position D(V/m)                  1.205           1.201            1.115
   Position E(V/m)                  1.511           1.352            1.315
   Limits (V/m)                                       614
   50% Limits(V/m)                                    304



H-Filed Strength at (15 cm from edges A,B,C,D, 20 cm from top E) surrounding the
EUT (A/m)
   Test Mode                      Full Load        Half Load     Empty Load
   Frequency range (kHz)                       110.5 to 205 kHz
   Position A(A/m)                  0.128           0.127           0.101
   Position B(A/m)                  0.112           0.121           0.110
   Position C(A/m)                  0.115            0.115          0.114
   Position D(A/m)                  0.110            0.115          0.099
   Position E(A/m)                  0.198           0.195           0.155
   Limits (A/m)                                     1.630
   50% Limits (A/m)                                 0.625




                 EST Technology Co. ,Ltd   Report No. ESTE-R1907002   Page 5 of 11


  FCC ID: 2AOIU-C00220



Test Result for Test setup B:

Empty , Half , Full load all have been tested ,only worse case Max load (Full) is
reported.

E-Filed Strength at (distance 10cm to 1cm at 1cm iteration, i.e. at a distance of 10cm,
9cm, 8cm, ……. 1cm, Which is between the edge of the charger and the edge of of
probe,) surrounding the EUT (V/m)
 Test distance   Position A     Position B   Position C   Position D      Position E          Limits
     (cm)          (V/m)          (V/m)        (V/m)        (V/m)           (V/m)             (V/m)

      1            1.685          1.648        1.685         1.678            2.187            614

      2            1.678          1.669        1.677         1.664            2.168            614

      3            1.584          1.578        1.598         1.654            2.141            614

      4            1.545          1.554        1.588         1.599            2.121            614

      5            1.544          1.541        1.586         1.585            2.045            614

      6            1.535          1.534        1.575         1.578            1.981            614

      7            1.531          1.532        1.571         1.571            1.878            614

      8            1.489          1.498        1.568         1.561            1.868            614

      9            1.487          1.488        1.561         1.550            1.850            614

      10           1.454          1.455        1.544         1.549            1.774            614


H-Filed Strength at (distance 10cm to 1cm at 1cm iteration, i.e. at a distance of 10cm,
9cm, 8cm, ……. 1cm, Which is between the edge of the charger and the edge of of
probe,) surrounding the EUT (A/m)
 Test distance   Position A     Position B   Position C   Position D      Position E          Limits
     (cm)          (A/m)          (A/m)        (A/m)        (A/m)           (A/m)             (A/m)

      1            0.301          0.304        0.331         0.315            0.415            1.63

      2            0.289          0.301        0.300         0.305            0.300            1.63

      3            0.285          0.289        0.298         0.295            0.298            1.63

      4            0.274          0.277        0.288         0.277            0.288            1.63

      5            0.266          0.258        0.282         0.268            0.278            1.63

      6            0.248          0.249        0.276         0.255            0.276            1.63

      7            0.221          0.245        0.266         0.251            0.268            1.63

      8            0.201          0.212        0.240         0.221            0.241            1.63

      9            0.195          0.199        0.224         0.201            0.215            1.63

      10           0.175          0.187        0.201         0.198            0.204            1.63



                   EST Technology Co. ,Ltd         Report No. ESTE-R1907002           Page 6 of 11


 FCC ID: 2AOIU-C00220
8. Test Setup Photo

    Position A




                 EST Technology Co. ,Ltd   Report No. ESTE-R1907002   Page 7 of 11


FCC ID: 2AOIU-C00220



   Position B




                EST Technology Co. ,Ltd   Report No. ESTE-R1907002   Page 8 of 11


FCC ID: 2AOIU-C00220



   Position C




                EST Technology Co. ,Ltd   Report No. ESTE-R1907002   Page 9 of 11


FCC ID: 2AOIU-C00220



  Position D




               EST Technology Co. ,Ltd   Report No. ESTE-R1907002   Page 10 of 11


 FCC ID: 2AOIU-C00220



     Position E




Note: The dummy load must be placed horizontal of the EUT at the top.(Parallel to the coil)
                               ====END====


                  EST Technology Co. ,Ltd   Report No. ESTE-R1907002   Page 11 of 11