Document 75940027 Report 01 Issue 1

FCC ID: 2AOHPMP50A

Test Report

Download: PDF
FCCID_4013454

FCC Testing of the Axnes Aviation AS
Transceiver. Model: MP50 in conjunction with
Model: CHG50 and Model: CHG55 Chargers.
In accordance with FCC 47 CFR Part 15B
Prepared for:                  Axnes Aviation AS
                               Terje Lovasvei 1
                               Grimstad
                               N-4879
                               NORWAY

FCC ID: 2AOHP MP50A (MP50)

COMMERCIAL-IN-CONFIDENCE
Date: April 2018
Document Number: 75940027-01 | Issue: 01

RESPONSIBLE FOR                       NAME                                                                   DATE                               SIGNATURE

Project Management                    Steven White                                                           11 April 2018


Authorised Signatory                  Andy Lawson                                                            11 April 2018
Signatures in this approval box have checked this document in line with the requirements of TÜV SÜD Product Service document control rules.

ENGINEERING STATEMENT
The measurements shown in this report were made in accordance with the procedures described on test pages. All reported testing
was carried out on a sample equipment to demonstrate limited compliance with FCC 47 CFR Part 15B. The sample tested was
found to comply with the requirements defined in the applied rules.

RESPONSIBLE FOR                       NAME                                                                   DATE                               SIGNATURE

Testing                               Graeme Lawler                                                          11 April 2018

FCC Accreditation
90987 Octagon House, Fareham Test Laboratory

EXECUTIVE SUMMARY
A sample of this product was tested and found to be compliant with FCC 47 CFR Part 15B: 2017.




                                           DISCLAIMER AND COPYRIGHT
                                           This non-binding report has been prepared by TÜV SÜD Product Service with all reasonable skill and care. The document is confidential to the
                                           potential Client and TÜV SÜD Product Service. No part of this document may be reproduced without the prior written approval of TÜV SÜD
                                           Product Service. © 2018 TÜV SÜD Product Service.
                                           ACCREDITATION
                                           Our UKAS Accreditation does not cover opinions and interpretations and any expressed are outside the scope of our UKAS Accreditation.
                                           Results of tests not covered by our UKAS Accreditation Schedule are marked NUA (Not UKAS Accredited).



TÜV SÜD Product Service                         TUV SUD Ltd is a                            Phone: +44 (0) 1489 558100                    TÜV SÜD Product Service
is a trading name of TUV SUD Ltd                TÜV SÜD Group Company                       Fax: +44 (0) 1489 558101                      Octagon House
Registered in Scotland at East Kilbride,                                                    www.tuv-sud.co.uk                             Concorde Way
Glasgow G75 0QF, United Kingdom                                                                                                           Fareham
Registered number: SC215164                                                                                                               Hampshire PO15 5RL
                                                                                                                                          United Kingdom



     TÜV SÜD Product Service


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




Contents
1           Report Summary .........................................................................................................................2
1.1         Report Modification Record...........................................................................................................2
1.2         Introduction....................................................................................................................................2
1.3         Brief Summary of Results .............................................................................................................3
1.4         Application Form(s) .......................................................................................................................4
1.5         Product Information .......................................................................................................................7
1.6         Deviations from the Standard........................................................................................................7
1.7         EUT Modification Record ..............................................................................................................7
1.8         Test Location .................................................................................................................................8
2           Test Details ..................................................................................................................................9
2.1         Radiated Emissions.......................................................................................................................9
2.2         AC Power Line Conducted Emissions ........................................................................................17
3           Measurement Uncertainty ........................................................................................................21




      COMMERCIAL-IN-CONFIDENCE                                                                                                               Page 1 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




1          Report Summary

1.1        Report Modification Record

           Alterations and additions to this report will be issued to the holders of each copy in the form of a
           complete document.

            Issue           Description of Change                                               Date of Issue

            1               First Issue                                                         11 April 2018


                                                            Table 1

1.2        Introduction

           Applicant                                Axnes Aviation AS
           Manufacturer                             Axnes Aviation AS
           Model Number(s)                          MP50, (CHG50 / ZVC30NP12-I) and CHG55
           Serial Number(s)                         000 451, 000 121, Not Serialised (75940027-TSR0004)
                                                    and 000 149
           Hardware Version(s)                      R13 (MP50), R3 (CHG50), R3 (CHG55)
           Software Version(s)                      AXS-SW-0221 (MP50)
           Number of Samples Tested                 4
           Test Specification/Issue/Date            FCC 47 CFR Part 15B: 2017
           Order Number                             801584
           Date                                     26-July-2017
           Date of Receipt of EUT                   11-August-2017
           Start of Test                            11-September-2017
           Finish of Test                           13-September-2017
           Name of Engineer(s)                      Graeme Lawler
           Related Document(s)                      ANSI C63.4: 2014




      COMMERCIAL-IN-CONFIDENCE                                                                       Page 2 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




1.3       Brief Summary of Results

          A brief summary of the tests carried out in accordance with FCC 47 CFR Part 15B is shown below.

           Section      Specification Clause   Test Description                                       Result   Comments/Base Standard
           Configuration and Mode: PNG MP50 (Stand Alone) Idle
           2.1          15.109                 Radiated Emissions                                     Pass     ANSI C63.4
           Configuration and Mode: PNG MP50 + CHG55 Charger Charging
           2.1          15.109                 Radiated Emissions                                     Pass     ANSI C63.4
           Configuration and Mode: PNG MP50 + CHG50 Charger Charging
           2.2          15.107                 AC Power Line Conducted Emissions                      Pass     ANSI C63.4
           2.1          15.109                 Radiated Emissions                                     Pass     ANSI C63.4


                                                                                   Table 2




      COMMERCIAL-IN-CONFIDENCE                                                                                                     Page 3 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




1.4        Application Form(s)


1.1        DECLARATION OF BUILD STATUS


            Manufacturer                                  Axnes AS

            Country of origin                             Norway

            UK Agent                                      n/a

            Technical Description                         PNG MP50 Transceiver, component used in the PNG wireless
                                                          intercom system

            Model No                                      MP50

            Part No                                       AXS-HH-D0100-N-C0

            Serial No                                     000 451, 000 452

            Drawing Number                                AX-PNG-MCL-0176

            Build Status                                  R13

            Software Issue                                AXS-SW-0221

            Hardware Issue                                R13

            Highest Internally Generated                  1880MHz
            Frequency

            FCC ID                                        2AOHP MP50A (MP50)

            Industry Canada ID

                                                         Signature                    Petter Johnsen

                                                         Date                         07/09/2017

                                                         D of B S Serial No           75940027/001



           Note: This document has been prepared to enable manufacturers with no mechanism for producing their own Declaration of
           Build Status, to declare the build state of the equipment submitted for test.

           No responsibility will be accepted by TÜV SÜD Product Service as to the accuracy of the information declared in this
           document by the manufacturer.




      COMMERCIAL-IN-CONFIDENCE                                                                                       Page 4 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




           Manufacturer                                  Axnes AS

           Country of origin                             Norway

           UK Agent                                      n/a

           Technical Description                         PNG CHG50 Charger, component used in the PNG wireless
                                                         intercom system

           Model No                                      CHG50

           Part No                                       AXS-CHG-0100-N-C0

           Serial No                                     000 121

           Drawing Number                                AX-PNG-MCL-0427

           Build Status                                  R3

           Software Issue                                -

           Hardware Issue                                R3

           Highest Internally Generated                  -
           Frequency

           FCC ID                                        n/a

           Industry Canada ID                            n/a

                                                        Signature                    Petter Johnsen

                                                        Date                         07/09/2017

                                                        D of B S Serial No           75940027/002



          Note: This document has been prepared to enable manufacturers with no mechanism for producing their own Declaration of
          Build Status, to declare the build state of the equipment submitted for test.

          No responsibility will be accepted by TÜV SÜD Product Service as to the accuracy of the information declared in this
          document by the manufacturer.




   COMMERCIAL-IN-CONFIDENCE                                                                                         Page 5 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




           Manufacturer                                  Axnes AS

           Country of origin                             Norway

           UK Agent                                      n/a

           Technical Description                         PNG CHG55 Charger, component used in the PNG wireless
                                                         intercom system

           Model No                                      CHG55

           Part No                                       AXS-CHG-0150-N-C0

           Serial No                                     000 149

           Drawing Number                                AX-PNG-MCL-0184

           Build Status                                  R4

           Software Issue                                -

           Hardware Issue                                R4

           Highest Internally Generated                  -
           Frequency

           FCC ID                                        n/a

           Industry Canada ID                            n/a

                                                        Signature                    Petter Johnsen

                                                        Date                         07/09/2017

                                                        D of B S Serial No           75940027/003



          Note: This document has been prepared to enable manufacturers with no mechanism for producing their own Declaration of
          Build Status, to declare the build state of the equipment submitted for test.

          No responsibility will be accepted by TÜV SÜD Product Service as to the accuracy of the information declared in this
          document by the manufacturer.




   COMMERCIAL-IN-CONFIDENCE                                                                                         Page 6 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




1.5        Product Information


1.5.1      Technical Description

           PNG MP50 Transceiver, component used in the PNG wireless intercom system.

1.6        Deviations from the Standard

           No deviations from the applicable test standard were made during testing.

1.7        EUT Modification Record

           The table below details modifications made to the EUT during the test programme.
           The modifications incorporated during each test are recorded on the appropriate test pages.

                                                                                                            Date Modification
            Modification State   Description of Modification still fitted to EUT   Modification Fitted By
                                                                                                            Fitted
            Serial Number: 000 451

            0                    As supplied by the customer                       Not Applicable           Not Applicable

            Serial Number: 000 121
            0                    As supplied by the customer                       Not Applicable           Not Applicable
            Serial Number: Not Serialised (75940027-TSR0004)

            0                    As supplied by the customer                       Not Applicable           Not Applicable
            Serial Number: 000 149

            0                    As supplied by the customer                       Not Applicable           Not Applicable


                                                                     Table 3




      COMMERCIAL-IN-CONFIDENCE                                                                                   Page 7 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




1.8        Test Location

           TÜV SÜD Product Service conducted the following tests at our Fareham Test Laboratory.

            Test Name                                                       Name of Engineer(s)      Accreditation

            Configuration and Mode: PNG MP50 (Stand Alone) Idle

            Radiated Emissions                                              Graeme Lawler            UKAS

            Configuration and Mode: PNG MP50 + CHG55 Charger Charging

            Radiated Emissions                                              Graeme Lawler            UKAS

            Configuration and Mode: PNG MP50 + CHG50 Charger Charging

            AC Power Line Conducted Emissions                               Graeme Lawler            UKAS

            Radiated Emissions                                              Graeme Lawler            UKAS


                                                                  Table 4
           Office Address:

              Octagon House
              Concorde Way
              Segensworth North
              Fareham
              Hampshire
              PO15 5RL
              United Kingdom




      COMMERCIAL-IN-CONFIDENCE                                                                    Page 8 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2          Test Details

2.1        Radiated Emissions

2.1.1      Specification Reference

           FCC 47 CFR Part 15B, Clause 15.109

2.1.2      Equipment Under Test and Modification State

           MP50, S/N: 000 451 - Modification State 0
           CHG50, S/N: 000 121 - Modification State 0
           ZVC30NP12-I, S/N: Not Serialised (75940027-TSR0004) - Modification State 0
           CHG55, S/N: 000 149 - Modification State 0

2.1.3      Date of Test

           11-September-2017 to 12-September-2017

2.1.4      Test Method

           The test was performed in accordance with ANSI C63.4, clause 8.

2.1.5      Environmental Conditions

           Ambient Temperature        19.2 °C
           Relative Humidity          51.0 %




      COMMERCIAL-IN-CONFIDENCE                                                          Page 9 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2.1.6     Test Results

          PNG MP50 (Stand Alone) Idle

          Highest frequency generated or used within the EUT: 1880 MHz
          Upper frequency test limit: 10 GHz

           Frequency        QP Level         QP Limit       QP Margin
                                                                             Angle(Deg)   Height(m)   Polarity
           (MHz)            (dBuV/m)         (dBuV/m)       (dBuV/m)
            59.995          31.9             39.1           -7.2             103          1.00        Vertical

            60.005          30.4             39.1           -8.7             101          1.00        Vertical

            132.000         29.5             43.5           -14.0            55           1.00        Vertical
            132.004         29.2             43.5           -14.3            32           1.00        Vertical
            155.983         30.2             43.5           -13.3            346          1.00        Vertical

            155.993         30.8             43.5           -12.7            337          1.00        Vertical

            155.994         30.1             43.5           -13.4            8            1.00        Vertical


                                                Table 5 - 30 MHz to 1 GHz




                                   Figure 1 - 30 MHz to 1 GHz - Horizontal and Vertical




   COMMERCIAL-IN-CONFIDENCE                                                                      Page 10 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




           Frequency          Result (µV/m)                 Limit (µV/m)                 Margin (µV/m)       Angle (°)         Height   Polarisation
           (GHz)                                                                                                                (m)
                         Peak            Average           Peak      Average           Peak      Average
           *


                                                              Table 6 - 1 GHz to 10 GHz

          *No emissions were detected within 10 dB of the limit.

                                                                               * RBW   1 MHz     Marker 1 [T1 ]
                                                                               * VBW30 kHz               42.69 dBµV/m
                               Ref     80 dBµV/m           * Att   0 dB         SWT 340 ms            3.423076923 GHz

                               80
                                                                                                                         *
                               FC15BA_P                                                                                  A
                               70

                       1 PK
                       VIEW
                               60

                       2 PK
                       MAXH                                                                                              TDS
                               FC15BA_A
                               50
                                                       1                                                                 PA
                                                                                                                         PS
                               40



                               30

                                                                                                                         6DB
                               20                                                                                        AC



                               10



                               0



                               -10


                               -20

                               Start    1 GHz                             900 MHz/                       Stop   10 GHz




                       Date: 12.SEP.2017        22:09:45




                                         Figure 2 - 1 GHz to 10 GHz - Horizontal and Vertical




   COMMERCIAL-IN-CONFIDENCE                                                                                                         Page 11 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




          PNG MP50 + CHG55 Charger Charging

          Highest frequency generated or used within the EUT: 1880 MHz
          Upper frequency test limit: 10 GHz

           Frequency        QP Level         QP Limit       QP Margin
                                                                             Angle(Deg)   Height(m)   Polarity
           (MHz)            (dBuV/m)         (dBuV/m)       (dBuV/m)
            89.401          22.3             43.5           -21.2            248          1.00        Vertical
            90.883          29.9             43.5           -13.6            50           1.17        Vertical
            92.343          30.7             43.5           -12.8            161          1.00        Vertical

            93.816          24.7             43.5           -18.8            262          1.00        Vertical

            162.689         29.6             43.5           -13.9            277          1.00        Vertical
            165.611         29.0             43.5           -14.5            352          1.00        Vertical


                                                Table 7 - 30 MHz to 1 GHz




                                   Figure 3 - 30 MHz to 1 GHz - Horizontal and Vertical




   COMMERCIAL-IN-CONFIDENCE                                                                      Page 12 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




           Frequency          Result (µV/m)                 Limit (µV/m)                 Margin (µV/m)       Angle (°)         Height   Polarisation
           (GHz)                                                                                                                (m)
                          Peak           Average           Peak      Average           Peak      Average
           *


                                                              Table 8 - 1 GHz to 10 GHz

          *No emissions were detected within 10 dB of the limit.

                                                                               * RBW   1 MHz     Marker 1 [T1 ]
                                                                               * VBW30 kHz               43.37 dBµV/m
                               Ref     80 dBµV/m           * Att   0 dB         SWT 340 ms            3.451923077 GHz

                               80
                                                                                                                         *
                               FC15BA_P                                                                                  A
                               70

                       1 PK
                       VIEW
                               60

                       2 PK
                       MAXH                                                                                              TDS
                               FC15BA_A
                               50
                                                       1                                                                 PA
                                                                                                                         PS
                               40



                               30

                                                                                                                         6DB
                               20                                                                                        AC



                               10



                               0



                               -10


                               -20

                               Start    1 GHz                             900 MHz/                       Stop   10 GHz




                       Date: 12.SEP.2017        23:19:33




                                         Figure 4 - 1 GHz to 10 GHz - Horizontal and Vertical




   COMMERCIAL-IN-CONFIDENCE                                                                                                         Page 13 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




          PNG MP50 + CHG50 Charger Charging

          Highest frequency generated or used within the EUT: 1880 MHz
          Upper frequency test limit: 10 GHz


           Frequency        QP Level         QP Limit       QP Margin
                                                                             Angle(Deg)   Height(m)   Polarity
           (MHz)            (dBuV/m)         (dBuV/m)       (dBuV/m)
            202.217         37.3             43.5           -6.2             92           1.00        Vertical

            205.094         38.9             43.5           -4.6             110          1.00        Vertical

            206.605         38.7             43.5           -4.8             67           1.09        Vertical
            208.057         39.6             43.5           -3.9             82           1.00        Vertical

            209.542         39.5             43.5           -4.0             61           1.00        Vertical
            212.470         37.1             43.5           -6.4             86           1.00        Vertical


                                                Table 9 - 30 MHz to 1 GHz




                                   Figure 5 - 30 MHz to 1 GHz - Horizontal and Vertical




   COMMERCIAL-IN-CONFIDENCE                                                                      Page 14 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




           Frequency           Result (µV/m)                 Limit (µV/m)                 Margin (µV/m)       Angle (°)         Height   Polarisation
           (GHz)                                                                                                                 (m)
                           Peak           Average           Peak      Average           Peak      Average
           *


                                                              Table 10 - 1 GHz to 10 GHz

          *No emissions were detected within 10 dB of the limit.

                                                                                * RBW   1 MHz     Marker 1 [T1 ]
                                                                                * VBW30 kHz               42.51 dBµV/m
                                Ref     80 dBµV/m           * Att   0 dB         SWT 340 ms            3.423076923 GHz

                                80
                                                                                                                          *
                                FC15BA_P                                                                                  A
                                70

                        1 PK
                        VIEW
                                60

                        2 PK
                        MAXH                                                                                              TDS
                                FC15BA_A
                                50
                                                        1                                                                 PA
                                                                                                                          PS
                                40



                                30

                                                                                                                          6DB
                                20                                                                                        AC



                                10



                                0



                                -10


                                -20

                                Start    1 GHz                             900 MHz/                       Stop   10 GHz




                        Date: 12.SEP.2017        23:54:47




                                          Figure 6 - 1 GHz to 10 GHz - Horizontal and Vertical


          FCC 47 CFR Part 15, Limit Clause 15.109 (Class A)

           Frequency of Emission (MHz)                                                Field Strength (µV/m)

           30 to 88                                                                   90.0
           88 to 216                                                                  150.0
           216 to 960                                                                 210.0

           Above 960                                                                  300.0


                                                                              Table 11




   COMMERCIAL-IN-CONFIDENCE                                                                                                          Page 15 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2.1.7     Test Location and Test Equipment Used

          This test was carried out in EMC Chamber 5.

                                                                                   Calibration
           Instrument                 Manufacturer        Type No          TE No   Period        Calibration Due
                                                                                   (months)

           Antenna (Bilog)            Schaffner           CBL6143          287     24            18-Apr-2018

           Screened Room (5)          Rainford            Rainford         1545    36            20-Dec-2017

           Turntable Controller       Inn-Co GmbH         CO 1000          1606    -             TU

           Comb Generator             Schaffner           RSG1000          3034    -             TU

                                                          NPS-2302-8000-
           Cable (N-N, 8m)            Rhophase                             3248    12            02-May-2018
                                                          NPS

           EMI Test Receiver          Rohde & Schwarz     ESU40            3506    12            12-Nov-2017

           Tilt Antenna Mast          maturo Gmbh         TAM 4.0-P        3916    -             TU

           Mast Controller            maturo Gmbh         NCD              3917    -             TU

           Cable (Yellow, Rx, Km-Km                       KPS-1501-2000-
                                      Scott Cables                         4527    6             04-Nov-2017
           2m)                                            KPS

           Hygrometer                 Rotronic            HP21             4741    12            22-Aug-2018

           Double Ridge Broadband
                                      Schwarzbeck         BBHA 9120 B      4848    12            17-Feb-2018
           Horn Antenna

           Compliance 5 Emissions     Teseq               C5e Software     3275    -             N/A - Software


                                                        Table 12

          TU - Traceability Unscheduled




   COMMERCIAL-IN-CONFIDENCE                                                                      Page 16 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2.2        AC Power Line Conducted Emissions

2.2.1      Specification Reference

           FCC 47 CFR Part 15B, Clause 15.107

2.2.2      Equipment Under Test and Modification State

           MP50, S/N: 000 451 - Modification State 0
           CHG50, S/N: 000 121 - Modification State 0
           ZVC30NP12-I, S/N: Not Serialised (75940027-TSR0004) - Modification State 0

2.2.3      Date of Test

           13-September-2017

2.2.4      Test Method

           The test was performed in accordance with ANSI C63.4, clause 7.

2.2.5      Environmental Conditions

           Ambient Temperature        19.6 °C
           Relative Humidity          49.0 %




      COMMERCIAL-IN-CONFIDENCE                                                          Page 17 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2.2.6     Test Results

          PNG MP50 + CHG50 Charger Charging

          Applied supply Voltage: 60 Hz
          Applied supply frequency: 120 Vac

           Frequency        QP Level        QP Limit     QP Margin     AV Level       AV Limit    AV Margin
           (MHz)            (dBuV)          (dBuV)       (dBuV)        (dBuV)         (dBuV)      (dBuV)
            0.150           34.2            79.0         -44.8         19.8           66.0        -46.2

            0.192           51.7            79.0         -27.3         37.0           66.0        -29.0

            0.253           41.7            79.0         -37.3         29.0           66.0        -37.0
            19.835          31.0            73.0         -42.0         23.8           60.0        -36.2
            24.904          35.0            73.0         -38.0         31.7           60.0        -28.3

            29.304          36.8            73.0         -36.2         36.1           60.0        -23.9


                                           Table 13 - Live Line Emissions Results




                                           Figure 7 - Live Line - 150 kHz to 30 MHz




   COMMERCIAL-IN-CONFIDENCE                                                                      Page 18 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




           Frequency        QP Level         QP Limit     QP Margin        AV Level        AV Limit         AV Margin
           (MHz)            (dBuV)           (dBuV)       (dBuV)           (dBuV)          (dBuV)           (dBuV)
            0.150           37.4             79.0         -41.6            21.2            66.0             -44.8
            0.190           53.6             79.0         -25.4            39.4            66.0             -26.6

            0.255           43.9             79.0         -35.1            29.8            66.0             -36.2
            0.315           36.1             79.0         -42.9            22.2            66.0             -43.8
            20.471          31.3             73.0         -41.7            25.6            60.0             -34.4
            24.902          35.2             73.0         -37.8            33.1            60.0             -26.9


                                           Table 14 - Neutral Line Emissions Results




                                         Figure 8 - Neutral Line - 150 kHz to 30 MHz


          FCC 47 CFR Part 15, Limit Clause 15.107

           Frequency of Emission (MHz)                                  Conducted Limit (dBµV)
                                                           Quasi-Peak                             Average
           0.15 to 0.5                                            79                                  73
           0.5 to 30                                              66                                  60


                                                           Table 15




   COMMERCIAL-IN-CONFIDENCE                                                                                Page 19 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2.2.7     Test Location and Test Equipment Used

          This test was carried out in EMC Chamber 5.

                                                                                  Calibration
           Instrument                  Manufacturer        Type No        TE No   Period        Calibration Due
                                                                                  (months)

           Compliance 5 Emissions      Teseq               C5e Software   3275    -             N/A - Software

           Transient Limiter           Hewlett Packard     11947A         15      12            30-May-2018

           LISN (1 Phase)              Chase               MN 2050        336     12            07-Apr-2018

           Screened Room (5)           Rainford            Rainford       1545    36            20-Dec-2017

           Multimeter                  Iso-tech            IDM101         2417    12            30-Sep-2017

           EMI Test Receiver           Rohde & Schwarz     ESU40          3506    12            12-Nov-2017

           Digital thermo Hygrometer   Radio Spares        1260           4300    12            30-Aug-2018


                                                         Table 16




   COMMERCIAL-IN-CONFIDENCE                                                                     Page 20 of 21


Document Number: 75940027-01 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




3         Measurement Uncertainty

          For a 95% confidence level, the measurement uncertainties for defined systems are:

           Test Name                                       Measurement Uncertainty
           AC Power Line Conducted Emissions               150 kHz to 30 MHz, LISN, ±3.7 dB
           Radiated Emissions                              30 MHz to 1 GHz: ±5.2 dB
                                                           1 GHz to 40 GHz: ±6.3 dB


                                                     Table 17




    COMMERCIAL-IN-CONFIDENCE                                                                   Page 21 of 21



Document Created: 2018-04-11 14:23:01
Document Modified: 2018-04-11 14:23:01

© 2024 FCC.report