Document 75940027-08 Issue 01

FCC ID: 2AOHPBST50A

RF Exposure Info

Download: PDF
FCCID_4013388

Report On
RF Exposure Assessment of the
Axnes Aviation AS
PNG BST50 Wireless intercom extension for use in demanding high
noise environments

FCC ID: 2AOHP BST50A




Document 75940027 Report 8 Issue 1                        April 2018


                  TÜV SÜD Product Service, Octagon House, Concorde Way, Segensworth North,
                              Fareham, Hampshire, United Kingdom, PO15 5RL
                            Tel: +44 (0) 1489 558100. Website: www.tuv-sud.co.uk




REPORT ON                          RF Exposure Assessment of the
                                   Axnes Aviation AS
                                   PNG BST50 Wireless intercom extension for use in demanding high
                                   noise environments

                                   Document 75940027 Report 8 Issue 1

                                   April 2018


PREPARED FOR                       Axnes Aviation AS
                                   Terje Lovasvei 1
                                   Grimstad
                                   N-4879
                                   Norway




PREPARED BY
                                   David Guyett-Smith
                                   Chief Safety Engineer - Technical Solutions




APPROVED BY
                                   Matthew Russell
                                   Authorised Signatory


DATED                                10 April 2018




Document 75940027 Report 8 Issue 1                                                           Page 1 of 12


                                                                   CONTENTS

Section                                                                                                                                        Page No

1         REPORT SUMMARY ................................................................................................................... 3
1.1       Introduction .................................................................................................................................... 4
1.2       Regional Requirements ................................................................................................................. 5
1.3       Product Information ....................................................................................................................... 6
1.3.1     Technical Description .................................................................................................................... 6
1.3.2     Supported Features ....................................................................................................................... 6
1.3.3     Antennas ........................................................................................................................................ 6
2         TEST DETAILS ............................................................................................................................ 8
2.1       Rationale for Assessment of the RF Exposure ............................................................................. 9
2.2       Test Result Details....................................................................................................................... 10
3         DISCLAIMERS AND COPYRIGHT............................................................................................ 11
3.1       Disclaimers and Copyright ........................................................................................................... 12




Document 75940027 Report 8 Issue 1                                                                                                            Page 2 of 12


                                        SECTION 1


                                     REPORT SUMMARY




                             RF Exposure Assessment of the
                                   Axnes Aviation AS
    PNG BST50 Wireless intercom extension for use in demanding high noise environments




Document 75940027 Report 8 Issue 1                                               Page 3 of 12


1.1     INTRODUCTION


        The information contained in this report is intended to show verification of the RF Exposure
        Assessment of the Axnes Aviation AS PNG BST50 Wireless intercom extention for use in
        demanding high noise environments to the requirements of the applied test specifications.

        Objective                           To perform RF Exposure Assessment to determine the
                                            Equipment Under Test's (EUT’s) compliance of the applied
                                            rules.
        Applicant                           Axnes Aviation AS

        Manufacturer                        Axnes Aviation AS

        Manufacturing Description           Wireless intercom extension for use in demanding high
                                            noise environments
        Model Number(s)                     PNG BST50

        Test Specification/Issue/Date       CFR 47 Pt1.1310 (2016)




Document 75940027 Report 8 Issue 1                                                             Page 4 of 12


1.2     REGIONAL REQUIREMENTS

        The table below shows the regional requirements that are referenced in this test report. A full list
        of the requirements is shown in Annex A.

         Report Reference                                    Regional Requirement

         FCC                                                 CFR 47 Pt1.1310 (2016)




Document 75940027 Report 8 Issue 1                                                                Page 5 of 12


1.3     PRODUCT INFORMATION


1.3.1   Technical Description

        The Equipment under test was a Axnes Aviation AS PNG BST50 Wireless intercom extension for
        use in demanding high noise environments. A full technical description can be found in the
        manufacturer’s documentation.

        All reported calculations were carried out on the relevant information supplied for the PNG BST50
        Wireless intercom extension for use in demanding high noise environments to demonstrate
        compliance with the applied test specification(s). The sample assessed was found to comply with
        the requirements of the applied rules.


1.3.2   Supported Features

        The following radio access technologies and frequency bands are supported by the equipment
        under test.

         Radio Access Technology                           UHF 16QAM


         Frequency Band (MHz)                              405.0125 to 469.9875



1.3.3   Antennas

        The following antennas are supported by the equipment under test.

         No.                                Model                               Gain(dBi)

         1                                  UHF                                 5



        The wireless device described within this report has been shown to be capable of compliance
        with the basic restrictions related to human exposure to electromagnetic fields for both General
        Public and Occupational. The calculations shown in this report were made in accordance with
        the procedures specified in the applied test specification(s).

         Required Compliance Boundary (m)

         Occupational                                      General Population

         0.2                                               0.2


                                                                 Table 1 – Compliance Boundary Results




Document 75940027 Report 8 Issue 1                                                             Page 6 of 12


                          Calculated RF exposure level at compliance boundary of 0.2 m
         Regional
                          S Field (W/m2)                   E Field (V/m)                   H Field (A/m)
         Requirement
                          Result           Limit           Result            Limit         Result           Limit

         FCC*             0.1258           1.3500          N/A               N/A           N/A              N/A
                                               2
        * Requirement and Result in mW/cm

                                                                                   Table 2 – Occupational Results

        The calculations show that the EUT complies with the occupational exposure levels described in
        CFR 47 Pt1.1310 (2016) at the point of investigation, 0.2 m.

                          Calculated RF exposure level at compliance boundary of 0.2 m
         Regional
                          S Field (W/m2)                   E Field (V/m)                   H Field (A/m)
         Requirement
                          Result           Limit           Result            Limit         Result           Limit

         FCC*             0.1258           0.2700          N/A               N/A           N/A              N/A
        * Requirement and Result in mW/cm2

                                                                           Table 3 – General Population Results

        The calculations show that the EUT complies with the general population exposure levels
        described in CFR 47 Pt1.1310 (2016) at the point of investigation, 0.2 m.




Document 75940027 Report 8 Issue 1                                                                         Page 7 of 12


                                      SECTION 2


                                     TEST DETAILS




Document 75940027 Report 8 Issue 1                  Page 8 of 12


2.1     RATIONALE FOR ASSESSMENT OF THE RF EXPOSURE


        The aim of the assessment report is to evaluate the compliance boundary for a set of given input
        power according to the basic restrictions (directly or indirectly via compliance with reference
        levels) related to human exposure to radio frequency electromagnetic fields.
        The chosen assessment method to establish the compliance boundary in the far-field region is
        the reference method as defined in the relevant specifications.

        The RF exposure assessment is based upon the following criteria:

        The PNG BST50 Wireless intercom extension for use in demanding high noise environments
        operates with the following transmitters active on the antenna ports shown in Section 1.3.3. For
        each transmitter, the Radio Access Technology (RAT), EIRP inclusive of antenna gain and duty
        cycle, gain of the antenna and lowest frequency of operation are shown as they contribute to the
        calculation of S Field, E field and H field values according to the following formulas.

        The power flux (S Field):

              PG ( ,  )
         S
               4r 2

        The electric field strength (E Field):

                30PG ( ,  )
         E
                   r
        The magnetic field strength (H Field):

                E
         H 
                   o




        Where:

        P = Average Power (W)
        G = Antenna Gain (dBi)
        r = Distance (cm) or (m)
         o = 377




Document 75940027 Report 8 Issue 1                                                            Page 9 of 12


2.2     TEST RESULT DETAILS

        The frequencies shown in the tables below have been chosen based on the lowest possible
        frequency that the EUT can transmit.

                                                                                  RF Exposure Level at compliance
                                                    Duty                          boundary of 0.2 m
         Antenna   Tx    Ant               EIRP               Gain    Frequency
                               RAT                  Cycle
         Port      No.   No.               (W)                (dBi)   (MHz)       S Field    E Field    H Field
                                                    (%)
                                                                                  (W/m2)     (V/m)      (A/m)

         1         1     1     UHF 16QAM   0.632    50        5       405.0125    1.2581     21.7779    0.0578


                                                            Table 4 – Occupational Transmitter Summary

                                                                                  RF Exposure Level at compliance
                                                    Duty                          boundary of 0.2 m
         Antenna   Tx    Ant               EIRP               Gain    Frequency
                               RAT                  Cycle
         Port      No.   No.               (W)                (dBi)   (MHz)       S Field    E Field    H Field
                                                    (%)
                                                                                  (W/m2)     (V/m)      (A/m)

         1         1     1     UHF 16QAM   0.632    50        5       405.0125    1.2581     21.7779    0.0578


                                                   Table 5 – General Population Transmitter Summary




Document 75940027 Report 8 Issue 1                                                                Page 10 of 12


                                      SECTION 3


                              DISCLAIMERS AND COPYRIGHT




Document 75940027 Report 8 Issue 1                        Page 11 of 12


3.1     DISCLAIMERS AND COPYRIGHT




                         This report relates only to the actual item/items tested.

       This report must not be reproduced, except in its entirety, without the written permission of
                                      TÜV SÜD Product Service

                                   © 2018 TÜV SÜD Product Service




Document 75940027 Report 8 Issue 1                                                              Page 12 of 12


                                        ANNEX A


                                 REGIONAL REQUIREMENTS




Document 75940027 Report 8 Issue 1                       Page A.1 of A.2


                                                           Electric Field Strength   Magnetic Field Strength
         Frequency Range (MHz)   Power Density (mW/cm2)
                                                           (V/m)                     (A/m)

         0 - 0.3                 -                         -                         -

         0.3 - 3                 100                       614                       1.63

         3 - 30                  900/f^2                   1842/f                    4.89/f

         30 - 300                1                         61.4                      0.163

         300 - 1500              f/300                     -                         -

         1500 - 100000           5                         -                         -


                                               Table A.1 – CFR 47 Pt1.1310 (2016) Occupational Limits

                                                           Electric Field Strength   Magnetic Field Strength
         Frequency Range (MHz)   Power Density (mW/cm2)
                                                           (V/m)                     (A/m)

         0 - 0.3                 -                         -                         -

         0.3 - 3                 100                       614                       1.63

         3 - 30                  180/f^2                   824/f                     2.19/f

         30 - 300                0.2                       27.5                      0.073

         300 - 1500              f/1500                    -                         -

         1500 - 100000           1                         -                         -


                                          Table A.2 – CFR 47 Pt1.1310 (2016) General Population Limits




Document 75940027 Report 8 Issue 1                                                            Page A.2 of A.2



Document Created: 2018-04-10 11:28:45
Document Modified: 2018-04-10 11:28:45

© 2024 FCC.report