18_UPPXF5KBK-T RFExp r1

FCC ID: 2AOAF-800

RF Exposure Info

Download: PDF
FCCID_4508903

                                               TEST REPORT
 Reference No. ...................         :   WTF19S10071528W002 V1

 FCC ID ................................   :   2AOAF-800

 Applicant ............................    :   TYLT, inc.

 Address ..............................    :   685 Cochran St.Suite 200 Simi Valley, California, 93065 United States

 Manufacturer ....................         :   SHENZHEN GOODWIN TECHNOLOGY CO., LTD
                                               4/F Buiding A, Huayuan Industrial park, Fenghuang No.1 Industrial
 Address ..............................    :
                                               Area, Fuyong, Baoan Dist, Shenzhen, China
 Product...............................    :   Xact Flip 5K

 Model(s) ............................     :   UPPXF5KBK-T, UPPXF5KXX-T, UPPXF5KB-TC, UPPXF5KXX-TC
                                               FCC CFR 47 Part 1.1307
 Standards...........................      :
                                               FCC CFR 47 Part 1.1310
 Date of Receipt sample ....               :   2019-10-23

 Date of Test .......................      :   2019-10-24 to 2019-10-28

 Date of Issue ......................      :   2019-11-08

 Test Result .........................     :   Pass


 Remarks:
 The results shown in this test report refer only to the sample(s) tested, this test report cannot be
 reproduced, except in full, without prior written permission of the company. The report would be invalid
 without specific stamp of test institute and the signatures of compiler and approver.


                                                Prepared By:
                                   Waltek Services (Shenzhen) Co., Ltd.
      Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                             Guangdong, China
                                           Tel :+86-755-83551033
                                           Fax:+86-755-83552400

         Compiled by:                                                        Approved by:




         Ford Wang / Project Engineer                                        Philo Zhong / Manager




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                                      Page 1 of 14


Reference No.: WTF19S10071528W002 V1                    Page 2 of 14




1     Laboratories Introduction
Waltek Services (Shenzhen) Co., Ltd is a professional third-party testing and certification laboratory with
multi-year product testing and certification experience, established strictly in accordance with ISO/IEC 17025
requirements, and accredited by ILAC (International Laboratory Accreditation Cooperation) member. A2LA
(American Association for Laboratory Accreditation, the certification number is 4243.01) of USA, CNAS
(China National Accreditation Service for Conformity Assessment, the registration number is L3110) of
China.Meanwhile, Waltek has got recognition as registration and accreditation laboratory from EMSD
(Electrical and Mechanical Services Department), and American Energy star, FCC(The Federal
Communications Commission), CEC(California energy efficiency), ISED Canada (Innovation, Science and
Economic Development Canada). It’s the strategic partner and data recognition laboratory of international
authoritative organizations, such as Intertek(ETL-SEMKO), TÜV Rheinland, TÜV SÜD, etc.




Waltek Services (Shenzhen) Co., Ltd is one of the largest and the most comprehensive third party testing
laboratory in China. Our test capability covered four large fields: safety test. ElectroMagnetic
Compatibility(EMC), and energy performance, wireless radio. As a professional, comprehensive, justice
international test organization, we still keep the scientific and rigorous work attitude to help each client satisfy
the international standards and assist their product enter into globe market smoothly.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S10071528W002 V1               Page 3 of 14




1.1 Test Facility
      A. Accreditations for Conformity Assessment (International)
       Country/Region        Scope Covered By            Scope                    Note
       USA                                               FCC ID \ SDoC(VOC/DOC)   1
       Canada                                            IC ID \ VOC              2
       Japan                                             MIC-T \ MIC-R            -
       Europe                                            EMCD \ RED               -
       Taiwan                                            NCC                      -
                             ISO/IEC 17025
       Hong Kong                                         OFCA                     -
       Australia                                         RCM                      -
       India                                             WPC                      -
       Thailand                                          NTC                      -
       Singapore                                         IDA                      -
       Note:
       1.   FCC Designation No.: CN1201. Test Firm Registration No.: 523476.
       2.   ISED CAB identifier : CN0013. Test Firm Registration No.: 7760A.

      B.TCBs and Notify Bodies Recognized Testing Laboratory.


       Recognized Testing Laboratory of …                   Notify body number
       TUV Rheinland
       Intertek
                                                            Optional.
       TUV SUD
       SGS
       Phoenix Testlab GmbH                                 0700
       Element Materials Technology Warwick Ltd.            0891
       Timco Engineering, Inc.                              1177
       Eurofins Product Service GmbH                        0681




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S10071528W002 V1                                             Page 4 of 14



2    Contents
                                                                                                                                                              Page
    COVER PAGE ...................................................................................................................................... 1

1   LABORATORIES INTRODUCTION ................................................................................................................... 2
    1.1          TEST FACILITY ............................................................................................................................................ 3
2   CONTENTS ............................................................................................................................................................ 4

3   REVISION HISTORY ............................................................................................................................................ 5

4   GENERAL INFORMATION .................................................................................................................................. 6
    4.1          GENERAL DESCRIPTION OF E.U.T ............................................................................................................. 6
    4.2          DETAILS OF ACCESSORIES ......................................................................................................................... 6
    4.3          TEST MODE ................................................................................................................................................ 6
5   EQUIPMENT USED DURING TEST .................................................................................................................. 7
    5.1          EQUIPMENTS LIST ...................................................................................................................................... 7
    5.2          DESCRIPTION OF AUXILIARY EQUIPMENT .................................................................................................. 7
    5.3          TEST EQUIPMENT CALIBRATION ................................................................................................................ 7
6   RF EXPOSURE ...................................................................................................................................................... 8
    6.1          TEST SETUP ............................................................................................................................................... 8
    6.2          RF EXPOSURE LIMIT................................................................................................................................... 9
    6.3          TEST DATA ................................................................................................................................................. 9
    6.4          EUT COUPLING SURFACE AREA ............................................................................................................... 11
7   PHOTOGRAPH – RF EXPOSURE TEST SETUP ......................................................................................... 12




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


 Reference No.: WTF19S10071528W002 V1                 Page 5 of 14



 3       Revision History
                     Date of
                                                          Date of
Test report No.      Receipt           Date of Test                  Purpose     Comment   Approved
                                                           Issue
                     sample

                                       2019-10-24
WTF19S1007152
                   2019-10-23              to           2019-10-29    original      -      Replaced
      8W002                            2019-10-28

                                       2019-10-24
WTF19S1007152
                   2019-10-23              to           2019-11-08   Version 1   Updated    Valid
     8W002 V1                          2019-10-28




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S10071528W002 V1                Page 6 of 14



4    General Information

4.1 General Description of E.U.T
     Product:                     Xact Flip 5K
     Model(s):                    UPPXF5KBK-T, UPPXF5KXX-T, UPPXF5KB-TC, UPPXF5KXX-TC
     Model Description:           XX means different colors
     Frequency Range:             110~205kHz

     Modulation Type:             ASK

     Antenna Type:                Coil Antenna

     Antenna Gain:                0dBi


4.2 Details of accessories
                                 Input: USB-C 5V/2A, Output: 5V/2.4A
     Ratings:
                                 Wireless Output: 5W, Battery DC 3.7V, 5000mAh

4.3 Test Mode
     All the test model(s) and condition(s) mentioned were considered and evaluated respectively by
     performing full tests, the worst data were recorded and reported.


                 Description                     Test channel                 Test mode

                  Full Load*                      123.4kHz               Transmitting with Ant

                  Half Load                       123.4kHz               Transmitting with Ant

                  No Load                         123.4kHz               Transmitting with Ant
     All the mode were tested and passed, “*” show the worst case mode which were recorded in
     this report.




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


       Reference No.: WTF19S10071528W002 V1              Page 7 of 14



       5     Equipment Used during Test
       5.1 Equipments List
RF EXPOSURE
                                                                                     Last
                                                                                                Calibration
Item         Equipment           Manufacturer        Model No.       Serial No.   Calibration
                                                                                                 Due Date
                                                                                     Date
           MPE Measuring
 1                                   Narda           TLE-400          M-0170      2019-07-15    2020-07-14
             Instrument

       5.2 Description of Auxiliary Equipment
             Equipment           Manufacturer             Model No.                  Specification
           Wireless charging     Waltek Services
                               (Shenzhen) Co., Ltd               /                        5W
                receiver
            Resistive Load       Waltek Services                 /                        5W
                               (Shenzhen) Co., Ltd

       5.3 Test Equipment Calibration
             All the test equipments used are valid and calibrated by GUANG ZHOU GRG METROLOGY & TES
             T CO., LTD. address is No.163, Pingyun Rd. West of Huangpu Ave,Tianhe District, Guangzhou,
             Guangdong, China.




       Waltek Services (Shenzhen) Co.,Ltd.
       http://www.waltek.com.cn


Reference No.: WTF19S10071528W002 V1                 Page 8 of 14



6     RF Exposure
     Test Requirement:
     Environmental evaluation and exposure limit according to FCC CFR 47 Part 1.1307 (c) and (d),
     1.1310. According KDB680106 D01 RF Exposure Wireless Charging Apps v03
6.1 Test Setup

      These testing were performed at test configuration as follows.
     EUT was placed on a table, and the measure probe was placed at a measurement distance of 20cm
     from the top of EUT to the center of the probe and 15cm from other directions of EUT to the center
     of the probe..
     The EUT was put in different directions (Left, Right, Front, Rear, Top) to obtain the
     maximum reading.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S10071528W002 V1                Page 9 of 14


6.2 RF Exposure limit

     (A) Limits for Occupational / Controlled Exposure
                                               Magnetic Field                       Averaging Time
     Frequency Range        Electric Field                      Power Density (S)
                                                Strength (H)                         |E|2,|H|2or S
           (MHz)         Strength (E) (V/m)                        (mW/ cm2)
                                                   (A/m)                              (minutes)
          0.3-3.0               614                1.63              (100)*               6
           3.0-30             1842 / f            4.89 / f          (900 / f)*            6
          30-300                61.4              0.163                1.0                6
         300-1500                                                    F/300                6
       1500-100,000                                                     5                 6

      (B) Limits for General Population / Uncontrolled Exposure
                                              Magnetic Field                        Averaging Time
     Frequency Range        Electric Field                      Power Density (S)
                                               Strength (H)                          |E|2,|H|2 or S
           (MHz)         Strength (E) (V/m)                        (mW/ cm2)
                                                   (A/m)                               (minutes)
          0.3-1.34              614                1.63              (100)*               30
          1.34-30              824/f              2.19/f             (180/f)*             30
          30-300                27.5              0.073                0.2                30
         300-1500                                                    F/1500               30
       1500-100,000                                                    1.0                30
       Note: f = frequency in MHz ; *Plane-wave equivalent power density
6.3 Test Data

E-Field(Transmitting with Ant Load):
      Test Side           Separation              E-Field          MPE Limit(V/m)          Result
                         Distance(cm)         Measured(V/m)
        Left                   15                  2.35                  614            Compliance
        Right                  15                  2.64                  614            Compliance
        Front                  15                  2.60                  614            Compliance
        Rear                   15                  2.59                  614            Compliance
        Top                    20                  3.01                  614            Compliance
   % of MPE Limit                        0.49%                          Limit                 50%




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S10071528W002 V1              Page 10 of 14



H-Field(Transmitting with Ant Load):
      Test Side           Separation             H-Field          MPE Limit(A/m)     Result
                         Distance(cm)        Measured(A/m)
        Left                   15                 0.35                 1.63        Compliance
        Right                  15                 0.31                 1.63        Compliance
        Front                  15                 0.32                 1.63        Compliance
        Rear                   15                 0.37                 1.63        Compliance
        Top                    20                 0.45                 1.63        Compliance
   % of MPE Limit                       27.61%                        Limit           50%




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S10071528W002 V1                    Page 11 of 14



Remark: The device meets the RF exposure limit at separation distance as specified
in §1.1310 of the FCC Rules and meeting all of the following requirements as follows.
 (1) Power transfer frequency is less than 1 MHz.
(2) Output power from each primary coil is less than or equal to 15 watts.
(3) The transfer system includes only single primary and secondary coils. This includes charging systems
that may have multiple primary coils and clients that are able to detect and allow coupling only between
individual pairs of coils.
(4) Client device is placed directly in contact with the transmitter.
(5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).
(6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from
all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.


6.4 EUT coupling surface area

       The inductive area is below:




                                                     Ant




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S10071528W002 V1            Page 12 of 14



7     Photograph – RF Exposure Test Setup
                               Left Side(measurement distance of 15cm)




                              Right Side(measurement distance of 15cm)




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S10071528W002 V1            Page 13 of 14




                              Front Side(measurement distance of 15cm)




                               Rear Side(measurement distance of 15cm)




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S10071528W002 V1             Page 14 of 14


                               Top Side(measurement distance of 20cm)




                                      ======End of Report======




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn



Document Created: 2019-11-08 20:37:01
Document Modified: 2019-11-08 20:37:01

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC