14_UPPXF5KBK-T TestRpt 8CC r1

FCC ID: 2AOAF-800

Test Report

Download: PDF
FCCID_4508901

                                              TEST REPORT
Reference No. ....................        :   WTF19S10071528W001 V1
FCC ID ................................   :   2AOAF-800
Applicant ............................    :   TYLT, inc.

Address ..............................    :   685 Cochran St.Suite 200 Simi Valley, California, 93065 United States

Manufacturer ....................         :   SHENZHEN GOODWIN TECHNOLOGY CO., LTD
                                              4/F Buiding A, Huayuan Industrial park, Fenghuang No.1 Industrial
Address ..............................    :
                                              Area, Fuyong, Baoan Dist, Shenzhen, China
Product...............................    :   Xact Flip 5K

Model(s). ............................    :   UPPXF5KBK-T, UPPXF5KXX-T, UPPXF5KB-TC, UPPXF5KXX-TC

Standards ..........................      :   FCC PART 18, SUBPART C

Date of Receipt sample ....               :   2019-10-23

Date of Test .......................      :   2019-10-24 to 2019-10-28

Date of Issue ......................      :   2019-11-08
Test Result .........................     :   Pass


Remarks:
The results shown in this test report refer only to the sample(s) tested, this test report cannot be
reproduced, except in full, without prior written permission of the company. The report would be invalid
without specific stamp of test institute and the signatures of compiler and approver.

                                               Prepared By:
                                  Waltek Services (Shenzhen) Co., Ltd.
     Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                            Guangdong, China
                                          Tel :+86-755-83551033
                                          Fax:+86-755-83552400

        Compiled by:                                                        Approved by:




        Ford Wang / Project Engineer                                        Philo Zhong / Manager




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                                     Page 1 of 16


Reference No.: WTF19S10071528W001 V1                  Page 2 of 16




2       Laboratories Introduction
Waltek Services (Shenzhen) Co., Ltd is a professional third-party testing and certification laboratory with
multi-year product testing and certification experience, established strictly in accordance with ISO/IEC 17025
requirements, and accredited by ILAC (International Laboratory Accreditation Cooperation) member. A2LA
(American Association for Laboratory Accreditation, the certification number is 4243.01) of USA, CNAS
(China National Accreditation Service for Conformity Assessment, the registration number is L3110) of China.
Meanwhile, Waltek has got recognition as registration and accreditation laboratory from EMSD (Electrical
and Mechanical Services Department), and American Energy star, FCC (The Federal Communications
Commission), CEC (California energy efficiency), ISED (Innovation, Science and Economic Development
Canada). It’s the strategic partner and data recognition laboratory of international authoritative organizations,
such as Intertek (ETL-SEMKO), TÜV Rheinland, TÜV SÜD, etc.




Waltek Services (Shenzhen) Co., Ltd is one of the largest and the most comprehensive third party testing
laboratory in China. Our test capability covered four large fields: safety test. Electro Magnetic Compatibility
(EMC), and energy performance, wireless radio. As a professional, comprehensive, justice international test
organization, we still keep the scientific and rigorous work attitude to help each client satisfy the international
standards and assist their product enter into globe market smoothly.




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1             Page 3 of 16


Test Facility:


      A. Accreditations for Conformity Assessment (International)


        Country/Region         Scope Covered By             Scope                Note
        USA                                                 FCC ID \ DOC \ VOC   1
        Canada                                              IC ID \ VOC          2
        Japan                                               MIC-T \ MIC-R        -
        Europe                                              EMCD \ RED           -
        Taiwan                                              NCC                  -
                               ISO/IEC 17025
        Hong Kong                                           OFCA                 -
        Australia                                           RCM                  -
        India                                               WPC                  -
        Thailand                                            NTC                  -
        Singapore                                           IDA                  -
        Note:
        1.   FCC Designation No.: CN1201. Test Firm Registration No.: 523476.
        2.   ISED CAB identifier: CN0013. Test Firm Registration No.: 7760A.

      B. TCBs and Notify Bodies Recognized Testing Laboratory.


        Recognized Testing Laboratory of …                  Notify body number
        TUV Rheinland
        Intertek
                                                            Optional.
        TUV SUD
        SGS
        Phoenix Testlab GmbH                                0700
        Element Materials Technology Warwick Ltd            0891
        Timco Engineering, Inc.                             1177
        Eurofins Product Service GmbH                       0681




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1                                            Page 4 of 16




3       Contents
                                                                                                                                                                   Page

1      COVER PAGE ················································································································· 1
2      LABORATORIES INTRODUCTION ................................................................................................................... 2

3      CONTENTS ............................................................................................................................................................ 4

4      REVISION HISTORY ............................................................................................................................................ 5

5      GENERAL INFORMATION.................................................................................................................................. 6
       5.1          GENERAL DESCRIPTION OF E.U.T. ........................................................................................................... 6
       5.2          DETAILS OF E.U.T. ..................................................................................................................................... 6
       5.3          STANDARDS APPLICABLE FOR TESTING .................................................................................................... 6
       5.4          SUBCONTRACTED ....................................................................................................................................... 6
       5.5          ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 6
6      TEST SUMMARY .................................................................................................................................................. 7

7      EQUIPMENT USED DURING TEST .................................................................................................................. 8
       7.1          EQUIPMENT LIST......................................................................................................................................... 8
       7.2          DESCRIPTION OF SUPPORT UNITS ............................................................................................................. 8
       7.3          MEASUREMENT UNCERTAINTY................................................................................................................... 8
8      EMISSION TEST RESULTS ................................................................................................................................ 9
       8.1          POWER LINE CONDUCTED EMISSION, 150KHZ TO 30MHZ ...................................................................... 9
       8.2          RADIATION EMISSION, 9KHZ TO 30MHZ ................................................................................................. 12
9      PHOTOGRAPHS – TEST SETUP FCC ID 2AOAF-800 ............................................................................... 15
       9.1          PHOTOGRAPH –POWER LINE CONDUCTED EMISSION TEST SETUP AT TEST SITE 1# ........................... 15
       9.2          PHOTOGRAPH – RADIATED EMISSION TEST SETUP FOR 9KHZ~30MHZ AT TEST SITE 2# ................... 16




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1               Page 5 of 16




4       Revision History


                       Date of
                                                      Date of
Test report No.        Receipt      Date of Test                  Purpose     Comment   Approved
                                                       Issue
                       sample

                                    2019-10-24
WTF19S10071
                     2019-10-23         to          2019-10-29     original      -      Replaced
      528W001                       2019-10-28

                                    2019-10-24
WTF19S10071
                     2019-10-23         to          2019-11-08    Version 1   Updated     Valid
    528W001 V1                      2019-10-28




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1                   Page 6 of 16




5       General Information

5.1 General Description of E.U.T.
        Product:                       Xact Flip 5K
        Model(s):                      UPPXF5KBK-T, UPPXF5KXX-T, UPPXF5KB-TC, UPPXF5KXX-TC
        Model Description:             XX means different colors
        Frequency Range:               110~205kHz

        Modulation Type:               ASK

        Antenna Type:                  Coil Antenna

        Antenna Gain:                  0dBi

5.2 Details of E.U.T.
                                       Input: USB-C 5V/2A, Output: 5V/2.4A
        Ratings:
                                       Wireless Output :5W, Battery DC 3.7V, 5000mAh



5.3 Standards Applicable for Testing
          The tests were performed according to following standards:
          FCC PART 18, SUBPART C           Industrial, Scientific, and medical medical equipment.

5.4 Subcontracted
          Whether parts of tests for the product have been subcontracted to other labs:

             Yes             No
          If Yes, list the related test items and lab information:

          Test Lab:       N/A
          Lab address: N/A

          Test items:    N/A

5.5 Abnormalities from Standard Conditions
         None.




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1                Page 7 of 16




6       Test Summary


                      Test Items                       Test Requirement   Test Result


           Power Line Conducted Emission
                                                       FCC PART 18.307       Pass
                (150kHz to 30MHz)


                  Radiated Emission
                                                       FCC PART 18.305       Pass
                   9KHz to 30MHz)


      Remark:
      Pass    Test item meets the requirement
      Fail    Test item does not meet the requirement
      N/A     Test case does not apply to the test object




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


   Reference No.: WTF19S10071528W001 V1                Page 8 of 16




  7        Equipment Used during Test

  7.1 Equipment List
Conducted Emissions Test Site 1#
                                                                                       Last
                                                                                                       Calibration
 Item         Equipment           Manufacturer       Model No.         Serial No.   Calibration
                                                                                                        Due Date
                                                                                       Date
  1.       EMI Test Receiver          R&S                 ESCI          100947      2019-09-17         2020-09-16
  2.              LISN                R&S              ENV216           101215      2019-09-17         2020-09-16
  3.             Cable                 Top          TYPE16(3.5M)           -        2019-09-17         2020-09-16

3m Semi-anechoic Chamber for Radiation Emissions Test site 2#
                                                                                       Last
                                                                                                       Calibration
 Item         Equipment           Manufacturer       Model No.         Serial No    Calibration
                                                                                                        Due Date
                                                                                       Date
  1          Test Receiver            R&S                 ESCI          101296      2019-04-20         2020-04-19
  2       Active Loop Antenna Com-Power Corp.          AL-130R         10160007     2019-04-28         2020-04-27
  3             Amplifier          H/P                  8447F           880456      2019-09-10         2020-09-09
  4              Cable          HUBER+SUHNER              CBL2          525178      2019-04-20         2020-04-19




  7.2 Description of Support Units
       Equipment                 Manufacturer                     Model No.         Series No.

       MacBook Air               APPLE                            A1465             C17KTQDNF5N7
                                 LPS DELTA ELECTRNICS
       Power Supply                                               ADP-45GD          -
                                 UIANG CO,.LTD

  7.3 Measurement Uncertainty

               Test Item               Frequency Range                Uncertainty            Note

         Conduction Emission             150kHz~30MHz                  ±3.64dB                   (1)

          Radiation Emission                 9kHz~30MHz                ±5.03dB                   (1)

      Confidence interval:95%. Confidence factor:k=2




       Waltek Services (Shenzhen) Co.,Ltd.
       http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1                               Page 9 of 16




8       Emission Test Results

8.1 Power Line Conducted Emission, 150kHz to 30MHz

        Test Requirement ...............             :   FCC PART 18.307

        Test Method ........................         :   ANSI C63.4-2014

        Test Result ..........................       :   Pass
        Frequency Range ...............              :   150kHz to 30MHz

        Class ...................................    :   Class B
        Limit ...................................... :                                      Limit (dBμV)
                                                            Frequency (MHz)
                                                                                   Quasi-peak             erage
                                                                0.15 to 0.5         66 to 56*          56 to 46*
                                                                 0.5 to 5              56                 46
                                                                  5 to 30              60                 50

8.1.1 E.U.T. Operation
        Operating Environment:

        Temperature .......................          :   23°C
        Humidity ..............................      :   53.6%RH

        Atmospheric Pressure ........                :   101kPa

        EUT Operation:

        Input Voltage .......................        :   AC 120V/60Hz by PC adapter

        Operating Mode ..................            :   Wireless charging, Wired charging

8.1.2 Block Diagram of Test Setup
        The Mains Terminals Disturbance Voltage tests were performed in accordance with ANSI C63.4-2014.



                     0.4m

                                           PC            EUT                         Receiver      PC System



                                                                                                                   0.8m

               LISN


                                                                                             :50Ω Terminator




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1            Page 10 of 16


8.1.3 Measurement Data
     The maximised peak emissions from the EUT was scanned and measured for both the Live and
     Neutral Lines. Quasi-peak & average measurements were performed if peak emissions were within
     6dB of the average limit line. According to the data in below section, the EUT complied with the FCC
     PART 18, SUBPART C standards.

8.1.4 Power Line Conducted Emission Test Data
     Wireless charging(worst mode):
     Live Line:




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1   Page 11 of 16


   Wireless charging(worst mode):
      Neutral Line:




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1                              Page 12 of 16



8.2 Radiation Emission, 9KHz to 30MHz

     Test Requirement ...............             :    FCC PART 18.305
     Test Method ........................         :    ANSI C63.4-2014
     Test Result ..........................       :    Pass
     Frequency Range ...............              :    9KHz to 30MHz

     Class.                                        :   Class B

     Limit ....................................... :
                                                                                   Distance   Limit (dBμV/m)
                                                              Frequency (MHz)
                                                                                   (Meter)      Quasi-peak
                                                                 0.009 to 30           3           103.5



8.2.1 E.U.T. Operation
     Operating Environment:
     Temperature .......................          :    22.5°C
     Humidity ..............................      :    52.6%RH
     Atmospheric Pressure ........                :    101.2kPa
     EUT Operation:
     Input Voltage .......................        :    AC 120V/60Hz by PC adapter
     Operating Mode ..................            :    Wireless charging, Wired charging

8.2.2 Block Diagram of Test Setup
     The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site, using the
     setup accordance with the ANSI C63.4-2014.

     The test setup for emission measurement below 30MHz.




                    Semi-anechoic 3m Chamber
                    Turn Table From 0°to 360°




                                                                           3m
                                             EUT


                                         Turn Table
               0.8m




                                                 PC                  Spectrum         AMP      Combining
                                               System                Analyzer                   Network


 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1               Page 13 of 16


8.2.3 Measurement Data
     The maximised peak emissions from the EUT was scanned and measured for both the Antenna
     Vertical Polarization and Antenna Horizontal Polarization. Quasi-peak measurements were
     performed if peak emissions were within 6dB of the Quasi-peak limit line.

8.2.4 Radiated Emission Test Data, 9KHz to 30MHz

     Wireless charging(worst mode):
     Antenna Polarization: Vertical




 Factor= antenna factor + cable loss - preamplifier factor
 Result = Reading + Factor




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1                 Page 14 of 16


    Wireless charging(worst mode):
    Antenna Polarization: Horizontal




Factor= antenna factor + cable loss - preamplifier factor
Result = Reading + Factor
Note : Test with carry on X, Y, Z. The worst is Z.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1      Page 15 of 16




9       Photographs – Test Setup FCC ID 2AOAF-800

9.1 Photograph –Power Line Conducted Emission Test Setup at Test Site 1#




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


Reference No.: WTF19S10071528W001 V1            Page 16 of 16


9.2 Photograph – Radiated Emission Test Setup for 9KHz~30MHz at Test Site 2#




                                       ======End of Report======