Test Report

FCC ID: 2AOAF-120

Test Report

Download: PDF
FCCID_4275101

                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                  1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
                                  Shenzhen, China
                                  Telephone:     +86-755-26648640
                                  Fax:           +86-755-26648637                  Report Template Version: V03
                                  Website:       www.cqa-cert.com                  Report Template Revision Date: Mar.1st, 2017



                                            Test Report

Report No.:                     CQASZ20190400261E-01
Applicant:                      TYLT, inc.
Address of Applicant:           685 Cochran St. Suite 200, Simi Valley, California 93065, United States
Manufacturer:                   TYLT, inc.
Address of                      685 Cochran St. Suite 200, Simi Valley, California 93065, United States
Manufacturer:
Factory:                        DONGGUAN KINTEC DIGITAL TECHNOLOGY CO.,LIMITED
Address of Factory:             8F, JINYE BUILDING, NO.306, CHANGQING SOUTH ROAD, CHANG'AN,
                                DONGGUANG CITY, GUANGDONG, CHINA
Equipment Under Test (EUT):
Product:                Wireless charger
Model No.:              QIVENTBK3-T, 4588L, KQI-C32SM
Test Model No.:         QIVENTBK3-T
Brand Name:             N/A
FCC ID:                 2AOAF-120
Standards:                      47 CFR Part 15, Subpart C
Date of Test:                   2019-04-22 to 2019-04-28
Date of Issue:                  2019-04-28
Test Result :                   PASS*




Tested By:
                                                (Daisy Qin)


Reviewed By:
                                                (Aaron Ma )


Approved By:
                                                 ( Jack Ai)




* In the configuration tested, the EUT complied with the standards specified above.

The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only

to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full.


                                      Shenzhen Huaxia Testing Technology Co., Ltd
                                                              Report No.: CQASZ20190400261E-01


1   Version


                           Revision History Of Report

         Report No.         Version                 Description            Issue Date
    CQASZ20190400261E-01    Rev.01                  Initial report         2019-04-28




                                     Page:2 of 26


                                            Shenzhen Huaxia Testing Technology Co., Ltd
                                                               Report No.: CQASZ20190400261E-01


2      Test Summary
         Test Item               Test Requirement               Test method         Result
                          47 CFR Part 15, Subpart C Section
    Antenna Requirement                                       ANSI C63.10 2013      PASS
                                       15.203
      AC Power Line
                          47 CFR Part 15, Subpart C Section
       Conducted                                              ANSI C63.10 2013      PASS
                                       15.207
        Emission
      20dB Occupied       47 CFR Part 15, Subpart C Section
                                                              ANSI C63.10 2013      PASS
        Bandwidth                      15.215
    Radiated Emission ,
                          47 CFR Part 15, Subpart C Section
     Radiated Spurious                                        ANSI C63.10 2013      PASS
                                       15.209
        Emissions




                                           Page:3 of 26


                                                                          Shenzhen Huaxia Testing Technology Co., Ltd
                                                                                                          Report No.: CQASZ20190400261E-01




3         Contents

                                                                                                                                                           Page
1      VERSION .................................................................................................................................................... 2
2      TEST SUMMARY ....................................................................................................................................... 3
3      CONTENTS ................................................................................................................................................ 4
4      GENERAL INFORMATION ........................................................................................................................ 5
    4.1      CLIENT INFORMATION.............................................................................................................................. 5
    4.2      GENERAL DESCRIPTION OF EUT ............................................................................................................. 5
    4.3      TEST ENVIRONMENT ............................................................................................................................... 6
    4.4      DESCRIPTION OF SUPPORT UNITS ........................................................................................................... 6
    4.5      STATEMENT OF THE MEASUREMENT UNCERTAINTY ................................................................................... 7
    4.6      TEST LOCATION ...................................................................................................................................... 7
    4.7      TEST FACILITY ........................................................................................................................................ 7
    4.8      DEVIATION FROM STANDARDS ................................................................................................................. 7
    4.9      OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................. 7
    4.10     EQUIPMENT LIST..................................................................................................................................... 8
5      TEST RESULTS AND MEASUREMENT DATA ........................................................................................ 9
    5.1    ANTENNA REQUIREMENT......................................................................................................................... 9
    5.2    CONDUCTED EMISSIONS ....................................................................................................................... 10
    5.3    20DB OCCUPY BANDWIDTH .................................................................................................................. 13
    5.4    RADIATED SPURIOUS EMISSION & RESTRICTED BANDS ........................................................................... 15
       5.4.1   Spurious Emissions .................................................................................................................... 15
6      PHOTOGRAPHS - EUT TEST SETUP .................................................................................................... 20
    6.1      RADIATED EMISSION ............................................................................................................................. 20
    6.2      CONDUCTED EMISSION ......................................................................................................................... 21
7      PHOTOGRAPHS - EUT CONSTRUCTIONAL DETAILS ........................................................................ 22




                                                                        Page:4 of 26


                                                   Shenzhen Huaxia Testing Technology Co., Ltd
                                                                      Report No.: CQASZ20190400261E-01


4       General Information
4.1 Client Information
        Applicant:                   TYLT, inc.
        Address of Applicant:        685 Cochran St. Suite 200, Simi Valley, California 93065, United
                                     States
        Manufacturer:                TYLT, inc.
        Address of Manufacturer:     685 Cochran St. Suite 200, Simi Valley, California 93065, United
                                     States
        Factory:                     DONGGUAN KINTEC DIGITAL TECHNOLOGY CO.,LIMITED
        Address of Factory:          8F, JINYE BUILDING, NO.306, CHANGQING SOUTH ROAD,
                                     CHANG'AN, DONGGUANG CITY, GUANGDONG, CHINA

4.2 General Description of EUT
        Product Name:                Wireless charger
        Model No.:                   QIVENTBK3-T, 4588L, KQI-C32SM
        Test Model No.:              QIVENTBK3-T
        Brand Name:                  N/A
        Hardware Version:            M05-C151-110
        Software Version:            0x4955A4
        Equipment Category            Non-ISM frequency
        Operation Frequency range    110-205KHz
        Modulation Type:             Induction
        Antenna Type:                Induction coil
        Antenna Gain:                0dBi
        EUT Power Supply:            DC 5V

Note:
1. All model: QIVENTBK3-T, 4588L, KQI-C32SM
Only the model QIVENTBK3-T was tested, since the electrical circuit design, layout, components used and
internal wiring were identical for the above models, with difference being color of appearance and model
name.

2. In section 15.31(m), regards to the operating frequency range less 1 MHz.




                                                  Page:5 of 26


                                               Shenzhen Huaxia Testing Technology Co., Ltd
                                                                    Report No.: CQASZ20190400261E-01




4.3 Test Environment
     Operating Environment:
     Temperature:                25.0 C
     Humidity:                   53 % RH
     Atmospheric Pressure:       1010mbar
     Test Mode:
     Mode a:                                  Wireless charging Mode at 5V (Full load)
     Mode b:                                  Wireless charging Mode at 5V (half load)
      Mode c:                               Wireless charging Mode at 5V (Null load)
Note:
The mode a was the worst case and only the data of the worst case record in this report.

4.4 Description of Support Units
      The EUT has been tested with associated equipment below.

    Description        Manufacturer          Model No.              Remark         FCC certification
      Adaptor            Samsung            EP-TA50CBC           Provide by lab       Verification
     Wireless
                                                                 Provide by lab            -
  electronic Load            -                    -




                                             Page:6 of 26


                                                Shenzhen Huaxia Testing Technology Co., Ltd
                                                                        Report No.: CQASZ20190400261E-01




4.5 Statement of the measurement uncertainty
     The data and results referenced in this document are true and accurate.
     The reader is cautioned that there may be errors within the calibration limits of the equipment and
     facilities.
     The measurement uncertainty was calculated for all measurements listed in this test report acc. to
     CISPR 16 - 4 „Specification for radio disturbance and immunity measuring apparatus and methods –
     Part 4: Uncertainty in EMC Measurements“ and is documented in the Shenzhen Huaxia Testing
     Technology Co., Ltd. quality system acc. to DIN EN ISO/IEC 17025.
     Furthermore, component and process variability of devices similar to that tested may result in
     additional deviation. The manufacturer has the sole responsibility of continued compliance of the
     device.
     Hereafter the best measurement capability for CQA laboratory is reported:

      No.      Item                                       Uncertainty            Notes

      1        Radiated Emission (Below 1GHz)             ±5.12dB                (1)

      2        Radiated Emission (Above 1GHz)             ±4.60dB                (1)

      3        Occupied Bandwidth                         1.1%                   (1)

      4        Temperature test                           0.8℃                   (1)

      5        Humidity test                              2.0%                   (1)

     (1)This uncertainty represents an expanded uncertainty expressed at approximately the 95%
     confidence level using a coverage factor of k=2.



4.6 Test Location
     Shenzhen Huaxia Testing Technology Co., Ltd,
     1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
     Shenzhen, China


4.7 Test Facility
    • A2LA (Certificate No. 4742.01)
    Shenzhen Huaxia Testing Technology Co., Ltd., Shenzhen EMC Laboratory is accredited by the
     American Association for Laboratory Accreditation(A2LA). Certificate No. 4742.01.
    • FCC Registration No.: 522263
    Shenzhen Huaxia Testing Technology Co., Ltd., Shenzhen EMC Laboratory has been registered and
    fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance
    letter from the FCC is maintained in our files. Registration No.:522263

4.8 Deviation from Standards
    None.


4.9 Other Information Requested by the Customer
    None.




                                               Page:7 of 26


                                            Shenzhen Huaxia Testing Technology Co., Ltd
                                                              Report No.: CQASZ20190400261E-01


4.10 Equipment List

                                                            Instrument   Calibration   Calibration
  Test Equipment     Manufacturer         Model No.             No.        Date        Due Date
 EMI Test Receiver      R&S                 ESR7             CQA-005     2018/9/26     2019/9/25
                                    AFS4-00010300-18-10P-                2018/9/26     2019/9/25
    Preamplifier       MITEQ                  4             CQA-035
   Loop antenna      Schwarzbeck         FMZB1516           CQA-087      2018/10/28    2020/10/27
   Bilog Antenna        R&S                HL562            CQA-011      2018/9/26     2020/9/25
  Coaxial Cable
  (Above 1GHz)          CQA                 N/A               C019       2018/9/26     2019/9/25
  Coaxial Cable
  (Below 1GHz)          CQA                  N/A              C020       2018/9/26     2019/9/25
 EMI Test Receiver      R&S                 ESPI3           CQA-013      2018/9/26     2019/9/25
       LISN             R&S                ENV216           CQA-003      2018/11/5     2019/11/4
   Coaxial cable        CQA                  N/A            CQA-C009     2018/9/26     2019/9/25




                                          Page:8 of 26


                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                      Report No.: CQASZ20190400261E-01


5   Test results and Measurement Data
5.1 Antenna Requirement
    Standard requirement:         47 CFR Part 15C Section 15.203
    15.203 requirement:
    An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
    responsible party shall be used with the device. The use of a permanently attached antenna or of an
    antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
    so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
    electrical connector is prohibited.
    15.247(b) (4) requirement:
    The conducted output power limit specified in paragraph (b) of this section is based on the use of
    antennas with directional gains that do not exceed 6 dBi. Except as shown in paragraph (c) of this
    section, if transmitting antennas of directional gain greater than 6 dBi are used, the conducted output
    power from the intentional radiator shall be reduced below the stated values in paragraphs (b)(1),
    (b)(2), and (b)(3) of this section, as appropriate, by the amount in dB that the directional gain of the
    antenna exceeds 6 dBi.
    EUT Antenna:




    The antenna is Induction coil. The best case gain of the antenna is 0dBi.




                                               Page:9 of 26


                                            Shenzhen Huaxia Testing Technology Co., Ltd
                                                               Report No.: CQASZ20190400261E-01




5.2 Conducted Emissions
   Test Requirement:    47 CFR Part 15C Section 15.207
   Test Method:         ANSI C63.10: 2013
   Test Frequency Range: 150kHz to 30MHz
   Limit:                                                            Limit (dBuV)
                           Frequency range (MHz)
                                                           Quasi-peak               Average
                                  0.15-0.5                   66 to 56*              56 to 46*
                                    0.5-5                       56                     46
                                      5-30                        60                   50
                        * Decreases with the logarithm of the frequency.
   Test Procedure:      1) The mains terminal disturbance voltage test was conducted in a shielded
                            room.
                        2) The EUT was connected to AC power source through a LISN 1 (Line
                            Impedance Stabilization Network) which provides a 50Ω/50µH + 5Ω linear
                            impedance. The power cables of all other units of the EUT were
                            connected to a second LISN 2, which was bonded to the ground reference
                            plane in the same way as the LISN 1 for the unit being measured. A
                            multiple socket outlet strip was used to connect multiple power cables to a
                            single LISN provided the rating of the LISN was not exceeded.
                        3) The tabletop EUT was placed upon a non-metallic table 0.8m above the
                            ground reference plane. And for floor-standing arrangement, the EUT was
                            placed on the horizontal ground reference plane.
                        4) The test was performed with a vertical ground reference plane. The rear of
                            the EUT shall be 0.4 m from the vertical ground reference plane. The
                            vertical ground reference plane was bonded to the horizontal ground
                            reference plane. The LISN 1 was placed 0.8 m from the boundary of the
                            unit under test and bonded to a ground reference plane for LISNs
                            mounted on top of the ground reference plane. This distance was between
                            the closest points of the LISN 1 and the EUT. All other units of the EUT
                            and associated equipment was at least 0.8 m from the LISN 2.
                        5) In order to find the maximum emission, the relative positions of equipment
                             and all of the interface cables must be changed according to
                           ANSI C63.10: 2013 on conducted measurement.
   Test Setup:




   Test Results:        Pass



                                        Page:10 of 26


                                                   Shenzhen Huaxia Testing Technology Co., Ltd
                                                                        Report No.: CQASZ20190400261E-01


Measurement Data
the worst case
Mode a:
Live line:




Remark:
1. The following Quasi-Peak and Average measurements were performed on the EUT:
2. Final Test Level =Receiver Reading + LISN Factor + Cable Loss.
3. If the Peak value under Average limit, the Average value is not recorded in the report.



                                                 Page:11 of 26


                                                   Shenzhen Huaxia Testing Technology Co., Ltd
                                                                        Report No.: CQASZ20190400261E-01

the worst case
Mode a:
Neutral line:




Remark:
1. The following Quasi-Peak and Average measurements were performed on the EUT:
2. Final Test Level =Receiver Reading + LISN Factor + Cable Loss.
3. If the Peak value under Average limit, the Average value is not recorded in the report.




                                                 Page:12 of 26


                                            Shenzhen Huaxia Testing Technology Co., Ltd
                                                                 Report No.: CQASZ20190400261E-01




5.3 20dB Occupy Bandwidth
   Test Requirement:       47 CFR Part 15C Section 15.215
   Test Method:            ANSI C63.10 2013
   Test Setup:




                           Remark: Offset=Cable loss+ attenuation factor.
   Test Results:           Pass

Measurement Data

                                              Mode a
    Test Frequency (KHz)               20dB Occupy Bandwidth (kHz)                  Result
           147.7                                   0.075                            Pass




                                          Page:13 of 26


                                                         Shenzhen Huaxia Testing Technology Co., Ltd
                                                                        Report No.: CQASZ20190400261E-01



Test plot as follows:


                                                          Graphs




     110K




                        Date: 26.APR.2019   18:01:53




                                                       Page:14 of 26


                                             Shenzhen Huaxia Testing Technology Co., Ltd
                                                                   Report No.: CQASZ20190400261E-01


5.4 Radiated Spurious Emission & Restricted bands
5.4.1 Spurious Emissions
    Test Requirement:   47 CFR Part 15C Section 15.209 and 15.205
    Test Method:        ANSI C63.10 2013
    Test Site:          Measurement Distance: 3m (Semi-Anechoic Chamber)
    Receiver Setup:             Frequency              Detector        RBW        VBW        Remark
                           0.009MHz-0.090MHz              Peak        10kHz      30kHz         Peak
                           0.009MHz-0.090MHz           Average        10kHz      30kHz       Average
                           0.090MHz-0.110MHz          Quasi-peak      10kHz      30kHz     Quasi-peak
                           0.110MHz-0.490MHz              Peak        10kHz      30kHz         Peak
                           0.110MHz-0.490MHz           Average        10kHz      30kHz       Average
                            0.490MHz -30MHz           Quasi-peak      10kHz      30kHz     Quasi-peak
                               30MHz-1GHz             Quasi-peak     100 kHz     300kHz    Quasi-peak
                                                          Peak         1MHz       3MHz         Peak
                               Above 1GHz
                                                          Peak         1MHz       10Hz       Average
    Limit:                                       Field strength     Limit                   Measurement
                              Frequency                                         Remark
                                                (microvolt/meter) (dBuV/m)                  distance (m)
                        0.009MHz-0.490MHz         2400/F(kHz)          -           -              300
                        0.490MHz-1.705MHz         24000/F(kHz)         -           -              30
                          1.705MHz-30MHz               30              -           -              30
                            30MHz-88MHz                100          40.0      Quasi-peak           3
                           88MHz-216MHz                150          43.5      Quasi-peak           3
                          216MHz-960MHz                200          46.0      Quasi-peak           3
                            960MHz-1GHz                500          54.0      Quasi-peak           3
                             Above 1GHz                500          54.0       Average             3
                               Note: 15.35(b), Unless otherwise specified, the limit on peak radio
                        frequency emissions is 20dB above the maximum permitted average emission
                        limit applicable to the equipment under test. This peak limit applies to the total
                        peak emission level radiated by the device.




                                          Page:15 of 26


                                       Shenzhen Huaxia Testing Technology Co., Ltd
                                                                 Report No.: CQASZ20190400261E-01

Test Setup:




                                 Figure 1. Below 30MHz




                                                     150cm




Figure 2. 30MHz to 1GHz                                      Figure 3. Above 1 GHz
Test Procedure:      a. 1) Below 1G: The EUT was placed on the top of a rotating table 0.8
                        meters above the ground at a 3 meter semi-anechoic camber. The table
                        was rotated 360 degrees to determine the position of the highest
                        radiation.
                        2) Above 1G: The EUT was placed on the top of a rotating table 1.5
                        meters above the ground at a 3 meter semi-anechoic camber. The table
                        was rotated 360 degrees to determine the position of the highest
                        radiation.
                        Note: For the radiated emission test above 1GHz:
                        Place the measurement antenna away from each area of the EUT
                        determined to be a source of emissions at the specified measurement
                        distance, while keeping the measurement antenna aimed at the source
                        of emissions at each frequency of significant emissions, with polarization
                        oriented for maximum response. The measurement antenna may have
                        to be higher or lower than the EUT, depending on the radiation pattern of
                        the emission and staying aimed at the emission source for receiving the
                        maximum signal. The final measurement antenna elevation shall be that
                        which maximizes the emissions. The measurement antenna elevation
                        for maximum emissions shall be restricted to a range of heights of from
                        1 m to 4 m above the ground or reference ground plane.
                     b. The EUT was set 3 meters away from the interference-receiving
                        antenna, which was mounted on the top of a variable-height antenna
                        tower.
                     c. The antenna height is varied from one meter to four meters above the
                        ground to determine the maximum value of the field strength. Both
                        horizontal and vertical polarizations of the antenna are set to make the


                                     Page:16 of 26


                                                     Shenzhen Huaxia Testing Technology Co., Ltd
                                                                           Report No.: CQASZ20190400261E-01

                                    measurement.
                                 d. For each suspected emission, the EUT was arranged to its worst case
                                    and then the antenna was tuned to heights from 1 meter to 4 meters (for
                                    the test frequency of below 30MHz, the antenna was tuned to heights 1
                                    meter) and the rotatable table was turned from 0 degrees to 360
                                    degrees to find the maximum reading.
                                 e. The test-receiver system was set to Peak Detect Function and Specified
                                    Bandwidth with Maximum Hold Mode.
                                 f. If the emission level of the EUT in peak mode was 10dB lower than the
                                    limit specified, then testing could be stopped and the peak values of the
                                    EUT would be reported. Otherwise the emissions that did not have 10dB
                                    margin would be re-tested one by one using peak, quasi-peak or
                                    average method as specified and then reported in a data sheet.
                                 g. Repeat above procedures until all frequencies measured was complete.
        Test Results:            Pass



Radiated Emission below 9K~30MHz
the worst case
Test mode:                       Mode a



                                                 Factor           Level          Limit
Frequency                       Reading                                                       Margin
                 Polarization                      dB           dB(uV/m)       dB(uV/m)                   Pass/Fail
   MHz                           dB(uV)                                                         dB
                                                  (1/m)           Peak         Average
  0.1477            Face          48.32           19.54           67.86         104.28         36.42        Pass
   0.1477          Side           47.65          19.54           67.19         104.28         37.09         Pass
Note: No other emissions found between lowest internal used/generated frequencies to 30MHz. The peak
level of the emission is less than the average limit, so the average level shall be less than the limit without test.




                                                  Page:17 of 26


                                               Shenzhen Huaxia Testing Technology Co., Ltd
                                                                   Report No.: CQASZ20190400261E-01



Radiated Emission
30MHz~1GHz, the worst case
Test mode:                    Mode a                                   Vertical




Remark:
   The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
   equation with a sample calculation is as follows:
   Final Test Level =Receiver Reading + Antenna Factor + Cable Factor




                                             Page:18 of 26


                                               Shenzhen Huaxia Testing Technology Co., Ltd
                                                                   Report No.: CQASZ20190400261E-01

30MHz~1GHz, the worst case
Test mode:                    Mode a                                    Horizontal




Remark:
   The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
   equation with a sample calculation is as follows:
   Final Test Level =Receiver Reading + Antenna Factor + Cable Factor




                                             Page:19 of 26


                            Shenzhen Huaxia Testing Technology Co., Ltd
                                           Report No.: CQASZ20190400261E-01


6   Photographs - EUT Test Setup

6.1 Radiated Emission
    9KHz~30MHz:




    30MHz~1GHz:




                          Page:20 of 26


                           Shenzhen Huaxia Testing Technology Co., Ltd
                                          Report No.: CQASZ20190400261E-01




6.2 Conducted Emission




                         Page:21 of 26


                                    Shenzhen Huaxia Testing Technology Co., Ltd
                                                   Report No.: CQASZ20190400261E-01




7   Photographs - EUT Constructional Details
    Test Model No.: QIVENTBK3-T




                                  Page:22 of 26


  Shenzhen Huaxia Testing Technology Co., Ltd
                 Report No.: CQASZ20190400261E-01




Page:23 of 26


  Shenzhen Huaxia Testing Technology Co., Ltd
                 Report No.: CQASZ20190400261E-01




Page:24 of 26


  Shenzhen Huaxia Testing Technology Co., Ltd
                 Report No.: CQASZ20190400261E-01




Page:25 of 26


  Shenzhen Huaxia Testing Technology Co., Ltd
                 Report No.: CQASZ20190400261E-01




  .The End




Page:26 of 26



Document Created: 2019-05-14 02:51:50