FCC PART BT4.0-15.249

FCC ID: 2AO94-H701

Test Report

Download: PDF
FCCID_3839625

                                            Page 1 of 24           Report No.: HK180420233-E




                          FCC TEST REPORT



                                  Test report
                                  On Behalf of
                         MOKO TECHNOLOGY LIMITED
                                      For
                           FITPOLO Smart Wristband
               Model No.: H701, H701A, H701S, H701R, H701BP, H702,
          H702A, H702P, H703, H704, H705, H706, H707, H708, H709, H710

                                    FCC ID: 2AO94-H701




 Prepared for :   MOKO TECHNOLOGY LIMITED
                  2F, Building1, No.37 Xiaxintang Xintang village, Fucheng Street, Longhua District,
                  Shenzhen,Guangdong Province, China




 Prepared By :    Shenzhen HUAK Testing Technology Co., Ltd.
                  1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street,
                  Bao'an District, Shenzhen City, China




Date of Test:     Apr. 20, 2018 ~ Apr. 27, 2018
Date of Report:   Apr. 27, 2018
Report Number:    HK180420233-E


                                                                  Page 2 of 24            Report No.: HK180420233-E




                                         TEST RESULT CERTIFICATION

Applicant’s name ................. : MOKO TECHNOLOGY LIMITED
                                                 2F, Building1, No.37 Xiaxintang Xintang village, Fucheng Street,
Address ................................. :
                                                 Longhua District,Shenzhen,Guangdong Province, China
Manufacture's Name ............ : MOKO TECHNOLOGY LIMITED
                                                 2F, Building1, No.37 Xiaxintang Xintang village, Fucheng Street,
Address ................................. :
                                                 Longhua District,Shenzhen,Guangdong Province, China
Product description


Trade Mark:


Product name ........................... : FITPOLO Smart Wristband
                                                 H701, H701A, H701S, H701R, H701BP, H702, H702A, H702P,
Model and/or type reference :
                                          H703, H704, H705, H706, H707, H708, H709, H710
                                          FCC Rules and Regulations Part 15 Subpart C Section 15.249
Standards ............................. :
                                          ANSI C63.10: 2013
This publication may be reproduced in whole or in part for non-commercial purposes as long as
the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source
of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will
not assume liability for damages resulting from the reader's interpretation of the reproduced
material due to its placement and context.
Date of Test ............................................ :
Date (s) of performance of tests ............. :                Apr. 20, 2018 ~ Apr. 27, 2018
Date of Issue ........................................... :     Apr. 27, 2018
Test Result ............................................... :   Pass




                          Testing Engineer                  :


                                                                            (Gary Qian)

                          Technical Manager                 :

                                                                             (Eden Hu)


                          Authorized Signatory :


                                                                           (Jason Zhou)


                                        Page 3 of 24   Report No.: HK180420233-E



                            Table of Contents                          Page


1 . TEST SUMMARY                                                              4
2 . GENERAL INFORMATION                                                       5
  2.1 GENERAL DESCRIPTION OF EUT                                              5
  2.2 Carrier Frequency of Channels                                           6
  2.3 Operation of EUT during testing                                         6
  2.4 DESCRIPTION OF TEST SETUP                                               6
  2.5 MEASUREMENT INSTRUMENTS LIST                                            7
3 . CONDUCTED EMISSIONS TEST                                                  8
  3.1 Conducted Power Line Emission Limit                                     8
  3.2 Test Setup                                                              8
  3.3 Test Procedure                                                          8
  3.4 Test Result                                                             8
4 RADIATED EMISSION TEST                                                   11
  4.1 Radiation Limit                                                      11
  4.2 Test Setup                                                           11
  4.3 Test Procedure                                                       12
  4.4 Test Result                                                          12
5 BAND EDGE                                                               18
  5.1 Limits                                                               18
  5.2 Test Procedure                                                       18
  5.3 Test Result                                                          18
6 OCCUPIED BANDWIDTH MEASUREMENT                                          20
  6.1 Test Setup                                                           20
  6.2 Test Procedure                                                       20
  6.3 Measurement Equipment Used                                           20
  6.4 Test Result                                                          20
7 ANTENNA REQUIREMENT                                                     22
8 PHOTOGRAPH OF TEST                                                      23
  8.1 Conducted Emission                                                   23
  8.2 Radiated Emission                                                    24


                                            Page 4 of 24            Report No.: HK180420233-E


1. TEST SUMMARY

1.1 TEST PROCEDURES AND RESULTS

  DESCRIPTION OF TEST                                            RESULT
  CONDUCTED EMISSIONS TEST                                      COMPLIANT
  RADIATED EMISSION TEST                                        COMPLIANT
  BAND EDGE                                                     COMPLIANT
  OCCUPIED BANDWIDTH MEASUREMENT                                COMPLIANT
  ANTENNA REQUIREMENT                                           COMPLIANT




1.2 TEST FACILITY

 Test Firm      : Shenzhen HUAK Testing Technology Co., Ltd.


 Address            1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai
                    Street, Bao'an District, Shenzhen City, China




1.3 MEASUREMENT UNCERTAINTY

  Measurement Uncertainty
  Conducted Emission Expanded Uncertainty                       =   2.23dB, k=2
  Radiated emission expanded uncertainty(9kHz-30MHz)            =   3.08dB, k=2
  Radiated emission expanded uncertainty(30MHz-1000MHz)         =   4.42dB, k=2
  Radiated emission expanded uncertainty(Above 1GHz)            =   4.06dB, k=2


                                        Page 5 of 24            Report No.: HK180420233-E




2. GENERAL INFORMATION

2.1 GENERAL DESCRIPTION OF EUT

     Equipment                FITPOLO Smart Wristband
     Model Name               H701
     Serial No.               H701A, H701S, H701R, H701BP, H702, H702A, H702P,
                              H703, H704, H705, H706, H707, H708, H709, H710


     Trade Mark


                              All model’s the function, software and electric circuit are
     Model Difference         the same, only with a product color and model named
                              different. Test sample model: H701.
     FCC ID                   2AO94-H701
     Antenna Type             PCB Antenna
     Antenna Gain             0dBi
     BT Operation frequency   2402-2480MHz
     Number of Channels       40CH
     Modulation Type          GFSK
                              DC3.7V From Battery or DC 5V from adapter with
     Power Source
                              AC 120V/60Hz
                              DC3.7V From Battery or DC 5V from adapter with
     Power Rating
                              AC 120V/60Hz


                                                Page 6 of 24           Report No.: HK180420233-E

2.2 Carrier Frequency of Channels

                                             Channel List
                  Frequency             Frequency              Frequency              Frequency
      Channel       (MHz)     Channel     (MHz)      Channel     (MHz)      Channel     (MHz)
         01        2402         11       2422           21      2442          31       2462
         02        2404         12       2424           22      2444          32       2464
         03        2406         13       2426           23      2446          33       2466
         04        2408         14       2428           24      2448          34       2468
         05        2410         15       2430           25      2450          35       2470
         06        2412         16       2432           26      2452          36       2472
         07        2414         17       2434           27      2454          37       2474
         08        2416         18       2436           28      2456          38       2476
         09        2418         19       2438           29      2458          39       2478
         10        2420         20       2440           30      2460          40       2480


2.3 Operation of EUT during testing


     Operating Mode
     The mode is used: Transmitting mode
                         Low Channel: 2402MHz
                         Middle Channel: 2440MHz
                         High Channel: 2480MHz



2.4 DESCRIPTION OF TEST SETUP

Operation of EUT during Conducted testing:




                AC 120V/60Hz                  Adapter                      EUT


Operation of EUT during Radiation and Above1GHz Radiation testing:




                                               EUT




●   Adapter information
    Model: HW-059100CHQ
    Input: 100-240V~, 50/60Hz, 0.5A
    Output: 5VDC, 1A


                                             Page 7 of 24          Report No.: HK180420233-E



2.5 MEASUREMENT INSTRUMENTS LIST

                                                                                          Cal.
Item      Equipment          Manufacturer    Model No.      Serial No.      Last Cal.
                                                                                         Interval
            L.I.S.N.
 1.     Artificial Mains        R&S           ENV216        HKE-002      Dec. 28, 2017 1 Year
            Network
 2.        Receiver             R&S            ESCI 7       HKE-010      Dec. 28, 2017 1 Year
         RF automatic
 3.                           Tonscend        JS0806-2      HKE-060      Dec. 28, 2017 1 Year
          control unit
 4.    Spectrum analyzer        R&S            FSP40        HKE-025      Dec. 28, 2017 1 Year
 5.    Spectrum analyzer       Agilent        N9020A        HKE-048      Dec. 28, 2017 1 Year
 6.       Preamplifier      Schwarzbeck      BBV 9743       HKE-006      Dec. 28, 2017 1 Year
 7.    EMI Test Receiver   Rohde & Schwarz     ESCI 7       HKE-010      Dec. 28, 2017 1 Year
       Bilog Broadband
 8.                         Schwarzbeck      VULB9163       HKE-012      Dec. 28, 2017 1 Year
           Antenna
                                             FMZB 1519
 9.      Loop Antenna        Schwarzbeck                    HKE-014      Dec. 28, 2017 1 Year
                                                 B
10.      Horn Antenna       Schewarzbeck       9120D        HKE-013      Dec. 28, 2017 1 Year
                                             EMC051845
11.      Pre-amplifier          EMCI                        HKE-015      Dec. 28, 2017 1 Year
                                                 SE
12.      Pre-amplifier         Agilent        83051A        HKE-016      Dec. 28, 2017 1 Year
       EMI Test Software                     JS1120-B
13.                           Tonscend                      HKE-083      Dec. 28, 2017    N/A
           EZ-EMC                             Version
14.      Power Sensor          Agilent        E9300A        HKE-086      Dec. 28, 2017 1 Year
15.    Spectrum analyzer       Agilent        N9020A        HKE-048      Dec. 28, 2017 1 Year
16.     Signal generator       Agilent        N5182A        HKE-029      Dec. 28, 2017 1 Year
17.    Signal Generator        Agilent        83630A        HKE-028      Dec. 28, 2017 1 Year
18.     Shielded room         Shiel Hong        4*3*3       HKE-039      Dec. 28, 2017 3 Year


                                                Page 8 of 24              Report No.: HK180420233-E


3.   CONDUCTED EMISSIONS TEST

 3.1 Conducted Power Line Emission Limit
 For unintentional device, according to § 15.107(a) Line Conducted Emission Limits is as following




 * Decreasing linearly with the logarithm of the frequency
   For intentional device, according to §15.207(a) Line Conducted Emission Limit is same as above table.

 3.2 Test Setup




 3.3 Test Procedure
 1, The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
    manual. The EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is placed
    on the ground plane as per ANSI C63.10.
 2, Support equipment, if needed, was placed as per ANSI C63.10.
 3, All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10.
 4, If a EUT received DC power from the USB Port of Notebook PC, the PC’s adapter received
    AC120V/60Hz power through a Line Impedance Stabilization Network (LISN) which supplied power
    source and was grounded to the ground plane.
 5, All support equipments received AC power from a second LISN, if any.
 6, The EUT test program was started. Emissions were measured on each current carrying line of the EUT
    using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two
    monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1
    connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1
    connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
 7, Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes.


 3.4 Test Result

     Pass


                                             Page 9 of 24           Report No.: HK180420233-E



Test Specification: Line




       Remark: Transd = Cable lose + Antenna factor - Pre-amplifier; Margin = Limit – Level


                                             Page 10 of 24           Report No.: HK180420233-E



Test Specification: Neutral




       Remark: Transd = Cable lose + Antenna factor - Pre-amplifier; Margin = Limit – Level


                                                  Page 11 of 24               Report No.: HK180420233-E


4 RADIATED EMISSION TEST

 4.1 Radiation Limit
  For unintentional device, according to § 15.109(a), except for Class A digital devices, the field strength of
  radiated emissions from unintentional radiators at a distance of 3 meters shall not exceed the following
  values:
   Frequency                Distance                 Radiated                 Radiated
   (MHz)                    (Meters)                 (dBμV/m)                 (μV/m)
   30-88                    3                        40                       100
   88-216                   3                        43.5                     150
   216-960                  3                        46                       200
   Above 960                3                        54                       500

  For intentional device, according to § 15.209(a), the general requirement of field strength of radiated
  emissions from intentional radiators at a distance of 3 meters shall not exceed the above table.


 4.2 Test Setup

   (1)Radiated Emission Test-Up Frequency Below 30MHz




   (2)Radiated Emission Test-Up Frequency 30MHz~1GHz


                                               Page 12 of 24              Report No.: HK180420233-E



  (3)Radiated Emission Test-Up Frequency Above 1GHz




4.3 Test Procedure
 1. Below 1GHz measurement the EUT is placed on turntable which is 0.8m above ground plane.
    And above 1GHz measurement EUT was placed on low permittivity and low tangent turn table
    which is 1.5m above ground plane.
 2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission level.
 3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the highest
   emissions.
 4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
 5. And also, each emission was to be maximized by changing the polarization of receiving antenna both
   horizontal and vertical.
 6. Repeat above procedures until the measurements for all frequencies are complete.
 7. The test frequency range from 9KHz to 25GHz per FCC PART 15.33(a).

 Note:
 For battery operated equipment, the equipment tests shall be performed using a new battery.


4.4 Test Result

   PASS
   All the test modes completed for test. The worst case of Radiated Emission
   is CH 2402; the test data of this mode was reported.


                                          Page 13 of 24           Report No.: HK180420233-E



Below 1GHz Test Results:


Antenna polarity: H




    Remark: Transd = Cable lose + Antenna factor - Pre-amplifier; Margin = Limit – Level


                                                   Page 14 of 24             Report No.: HK180420233-E



      Antenna polarity: V




         Remark: Transd = Cable lose + Antenna factor - Pre-amplifier; Margin = Limit – Level

Remark:
(1) Measuring frequencies from 9 KHz to the 1 GHz, Radiated emission test from 9KHz to 30MHz was verified,
and no any emission was found except system noise floor.
(2) * denotes emission frequency which appearing within the Restricted Bands specified in
 provision of 15.205, then the general radiated emission limits in 15.209 apply.
(3) The IF bandwidth of EMI Test Receiver between 30MHz to 1GHz was 120KHz, 1 MHz
 for measuring above 1 GHz, below 30MHz was 10KHz.


                                             Page 15 of 24                Report No.: HK180420233-E


Above 1 GHz Test Results:
 CH Low (2402MHz)


 Horizontal:


   Frequency   Meter Reading      Factor     Emission Level       Limits          Margin
                                                                                            Detector
     (MHz)         (dBμV)          (dB)         (dBμV/m)         (dBμV/m)          (dB)      Type

     2402          112.84          -5.84           107             114              -7        peak

     2402           86.56          -5.84          80.72            94             -13.28      AVG

     4804           56.27          -3.64          52.63            74             -21.37      peak

     4804           46.35          -3.64          42.71            54             -11.29      AVG

     7206           55.41          -0.95          54.46            74             -19.54      peak

     7206           42.28          -0.95          41.33            54             -12.67      AVG

       ---           ---            ---             ---             ---             ---        ---

       ---           ---            ---             ---             ---             ---        ---

 Remark: Factor = Antenna Factor + Cable Loss – Pre-amplifier.




 Vertical:


  Frequency    Meter Reading      Factor     Emission Level       Limits          Margin
                                                                                            Detector
    (MHz)          (dBμV)          (dB)         (dBμV/m)         (dBμV/m)          (dB)      Type

     2402          111.96         -5.84          106.12            114             -7.88      peak

     2402          86.13          -5.84           80.29             94            -13.71      AVG

     4804          56.45          -3.64           52.81             74            -21.19      peak

     4804          45.88          -3.64           42.24             54            -11.76      AVG

     7206          55.37          -0.95           54.42             74            -19.58      peak

     7206          41.69          -0.95           40.74             54            -13.26      AVG

      ---            ---            ---             ---             ---             ---        ---

      ---            ---            ---             ---             ---             ---        ---

 Remark: Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                                              Page 16 of 24               Report No.: HK180420233-E



 CH Middle (2440MHz)


 Horizontal:


 Frequency     Meter Reading     Factor     Emission Level       Limits         Margin
                                                                                          Detector
   (MHz)          (dBμV)          (dB)         (dBμV/m)         (dBμV/m)          (dB)     Type

    2440          111.77         -5.71          106.06            114            -7.94      peak

    2440           85.26         -5.71           79.55            94             -14.45     AVG

    4880           55.43         -3.51           51.92            74             -22.08     peak

    4880           45.72         -3.51           42.21            54             -11.79     AVG

    7320           55.68         -0.82           54.86            74             -19.14     peak

    7320           41.54         -0.82           40.72            54             -13.28     AVG

     ---            ---            ---             ---             ---            ---        ---

     ---            ---            ---             ---             ---            ---        ---

Remark: Factor = Antenna Factor + Cable Loss – Pre-amplifier.




 Vertical:


 Frequency     Meter Reading     Factor     Emission Level       Limits         Margin
                                                                                          Detector
   (MHz)          (dBμV)          (dB)         (dBμV/m)         (dBμV/m)          (dB)     Type

    2440          111.34         -5.71          105.63            114            -8.37      peak

    2440           86.29         -5.71           80.58            94             -13.42     AVG

    4880           55.46         -3.51           51.95            74             -22.05     peak

    4880           45.57         -3.51           42.06            54             -11.94     AVG

    7320           55.19         -0.82           54.37            74             -19.63     peak

    7320           41.22         -0.82            40.4            54             -13.6      AVG

     ---            ---            ---             ---             ---            ---        ---

     ---            ---            ---             ---             ---            ---        ---

Remark: Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                                              Page 17 of 24                Report No.: HK180420233-E

CH High (2480MHz)
Horizontal:
 Frequency    Meter Reading      Factor      Emission Level       Limits          Margin
                                                                                            Detector
   (MHz)          (dBμV)          (dB)          (dBμV/m)        (dBμV/m)           (dB)      Type

    2480          110.62          -5.65          104.97            114             -9.03      peak

    2480           84.37          -5.65           78.72            94             -15.28      AVG

    4960           55.09          -3.43           51.66            74             -22.34      peak

    4960           45.73          -3.43           42.3             54              -11.7      AVG

    7440           54.15          -0.75           53.4             74              -20.6      peak

    7440           40.88          -0.75           40.13            54             -13.87      AVG

     ---            ---            ---             ---             ---              ---        ---

     ---            ---            ---             ---             ---              ---        ---

Remark: Factor = Antenna Factor + Cable Loss – Pre-amplifier.

 Vertical:
 Frequency    Meter Reading      Factor     Emission Level       Limits          Margin
                                                                                           Detector
   (MHz)          (dBμV)          (dB)         (dBμV/m)         (dBμV/m)           (dB)     Type

    2480          109.89         -5.65          104.24            114             -9.76      peak

    2480          84.25          -5.65            78.6            94              -15.4      AVG

    4960          54.71          -3.43           51.28            74              -22.72     peak

    4960          43.68          -3.43           40.25            54              -13.75     AVG

    7440          53.46          -0.75           52.71            74              -21.29     peak

    7440          40.33          -0.75           39.58            54              -14.42     AVG

     ---            ---            ---             ---             ---             ---        ---

     ---            ---            ---             ---             ---             ---        ---

Remark: Factor = Antenna Factor + Cable Loss – Pre-amplifier.


 Remark:
 (1) Measuring frequencies from 1 GHz to the 25 GHz。
 (2) “F” denotes fundamental frequency; “H” denotes spurious frequency. “E” denotes band edge
 frequency.
 (3) * denotes emission frequency which appearing within the Restricted Bands specified in
 provision of 15.205, then the general radiated emission limits in 15.209 apply.
 (4) Data of measurement within this frequency range shown “--- ” in the table above means the
 reading of emissions are attenuated more than 20dB below the permissible limits or the field
 strength is too small to be measured.
 (5) The IF bandwidth of EMI Test Receiver between 30MHz to 1GHz was 120KHz, 1 MHz for
 measuring above 1 GHz, below 30MHz was 10KHz. The resolution bandwidth of test
 receiver/spectrum analyzer is 1MHz and video bandwidth is 3MHz for peak measurement with
 peak detector at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum
 analyzer is 1MHz and video bandwidth is 10Hz for Average measurement with peak
 detection at frequency above 1GHz.
 (6) When the test results of Peak Detected below the limits of Average Detected, the Average
 Detected is not need completed. For example: Top Channel at Fundamental 73.16dBuV/m(PK
 Value) <93.98(AV Limit), at harmonic 53.20 dBuV/m(PK Value) <54 dBuV/m(AV Limit), the
 Average Detected not need to completed.
 (7)All modes of operation were investigated and the worst-case emissions are reported.


                                                 Page 18 of 24               Report No.: HK180420233-E

5 BAND EDGE

  5.1 Limits
  FCC PART 15.249(d) Emissions radiated outside of the specified frequency bands, except for harmonics,
  shall be attenuated by at least 50 dB below the level of the fundamental or to the general radiated emission
  limits in §15.209, whichever is the lesser attenuation.


  5.2 Test Procedure
  The band edge compliance of RF radiated emission should be measured by following the guidance
  in ANSI C63.10 with respect to maximizing the emission by rotating the EUT, measuring the emission
  while the EUT is situated in three orthogonal planes (if appropriate), adjusting the measurement antenna
  height and polarization etc. Set RBW to 100KHz and VBM to 300KHz to measure the peak field strength
  and set RBW to 1MHz and VBW to 10Hz to measure the average radiated field strength.The conducted
  RF band edge was measured by using a spectrum analyzer. Set span wide enough to capture
  the highest in-band emission and the emission at the band edge. Set RBW to 100 KHz and VBW to
  300 KHz, to measure the conducted peak band edge.


  5.3 Test Result

            PASS

Radiated Band Edge Test:
Operation Mode: TX CH Low (2402MHz)
Horizontal (Worst case)


  Frequency    Meter Reading      Factor      Emission Level        Limits          Margin        Detector
                                                                                                   Type
    (MHz)           (dBμV)         (dB)          (dBμV/m)          (dBμV/m)           (dB)

     2390           55.67          -5.81           49.86              74            -24.14         peak

     2390             /            -5.81             /                54                      /    AVG

     2400           53.74          -5.84           47.9               74              -26.1        peak

     2400             /            -5.84             /                54                  /        AVG

                      Remark: Factor = Antenna Factor + Cable Loss – Pre-amplifier.



Vertical:
  Frequency    Meter Reading      Factor      Emission Level        Limits          Margin        Detector
                                                                                                   Type
    (MHz)           (dBμV)         (dB)          (dBμV/m)          (dBμV/m)           (dB)

     2390           56.35          -5.81           50.54              74            -23.46         peak

     2390             /            -5.81             /                54              /            AVG

     2400           54.19          -5.84           48.35              74            -25.65         peak

     2400             /            -5.84             /                54                  /        AVG

Remark: Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                                                Page 19 of 24               Report No.: HK180420233-E



Operation Mode: TX CH High (2480MHz)
Horizontal (Worst case)


  Frequency   Meter Reading      Factor      Emission Level        Limits         Margin      Detector
                                                                                               Type
    (MHz)         (dBμV)           (dB)         (dBμV/m)         (dBμV/m)           (dB)

    2483.5         56.48          -5.65           50.83              74            -23.17       peak

    2483.5           /            -5.65             /                54              /          AVG

Remark: Factor = Antenna Factor + Cable Loss – Pre-amplifier.



Vertical:


  Frequency   Meter Reading      Factor      Emission Level        Limits         Margin      Detector
                                                                                               Type
    (MHz)         (dBμV)           (dB)         (dBμV/m)         (dBμV/m)           (dB)

    2483.5         54.21          -5.65           48.56              74            -25.44       peak

    2483.5           /            -5.65             /                54              /          AVG

Remark: Factor = Antenna Factor + Cable Loss – Pre-amplifier.

Remark: All the other emissions not reported were too low to read and deemed to comply with FCC limit.


                                               Page 20 of 24             Report No.: HK180420233-E


6 OCCUPIED BANDWIDTH MEASUREMENT


6.1 Test Setup
   Same as Radiated Emission Measurement


6.2 Test Procedure
  1. The EUT was placed on a turn table which is 0.8m above ground plane.
  2. Set EUT as normal operation.
  3. Based on ANSI C63.10 section 6.9.2: RBW= 100KHz. VBW= 300 KHz, Span=3MHz.
  4. The useful radiated emission from the EUT was detected by the spectrum analyser with peak detector.


6.3 Measurement Equipment Used

   Same as Radiated Emission Measurement


6.4 Test Result

          PASS

                                          20dB Bandwidth
                   Frequency                                              Result
                                                (MHz)
                   2402 MHz                     1.214                     PASS
                   2440 MHz                     1.213                     PASS
                   2480 MHz                     1.213                     PASS

         CH: 2402MHz


              Page 21 of 24   Report No.: HK180420233-E




CH: 2440MHz




CH: 2480MHz


                                                Page 22 of 24               Report No.: HK180420233-E


7 ANTENNA REQUIREMENT

 Standard Applicable
 For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be
 designed to ensure that no antenna other than that furnished by the responsible party shall be used
 with the device. And according to FCC 47 CFR Section 15.249, if transmitting antennas of directional
 gain greater than 6dBi are used, the power shall be reduced by the amount in dB that the directional
 gain of the antenna exceeds 6dBi.

 Refer to statement below for compliance.
 The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
 standard antenna jack or electrical connector is prohibited. Further, this requirement does not apply to
 intentional radiators that must be professionally installed.

 Antenna Connected Construction
 The antenna used in this product is a PCB Antenna, The directional gains of antenna used for
 transmitting is 0dBi.

  ANTENNA


                         Page 23 of 24   Report No.: HK180420233-E


8 PHOTOGRAPH OF TEST


8.1 Conducted Emission


                        Page 24 of 24   Report No.: HK180420233-E



8.2 Radiated Emission



Document Created: 2018-05-04 18:49:44
Document Modified: 2018-05-04 18:49:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC