Test Report revised 0604

FCC ID: 2AO5N-ONXD18

Test Report

Download: PDF
FCCID_3874130

FCC and IC Test Report for Parts
15.247, 15.207 and 15.209 (DTS)
     and RSS-247, RSS Gen




   Product name          : Onyx-PCB
   Applicant             : Feel Robotics
   FCC ID                : 2AO5N-ONXD18
   IC ID                 : 23801-ONXD18




      Test report No. : 180201427 002 v3.00


Report number: 180201427 002 v3.00


Laboratory information
Accreditation
Telefication is designated by the FCC as an Accredited Test Firm for compliance testing of equipment subject to
Certification under Parts 15 & 18. The Designation number is: NL0001.

The Industry Canada registration number for the 3 meter test chamber of Telefication is: 4173A-1.

Documentation

Telefication complies with the accreditation criteria for test laboratories as laid down in ISO/IEC 17025:2005.
The accreditation covers the quality system of the laboratory as well as the specific activities as described in
the authorized annex bearing the accreditation number L021 and is granted on 30 November 1990 by the
Dutch Council For Accreditation (RvA: Raad voor Accreditatie).

The test report must always be reproduced in full; reproduction of an excerpt only is subject to written
approval of the testing laboratory. The documentation of the testing performed on the tested devices is
archived for 10 years at Telefication Netherlands.

Testing Location

Test Site                                        Telefication BV
Test Site location                               Edisonstraat 12a
                                                 6902 PK Zevenaar
                                                 The Netherlands

                                                 Tel. +31889983600
                                                 Fax. +31316583189
Test Site FCC                                    NL0001




                                                                                                    Page 1 of 27


Report number: 180201427 002 v3.00

Revision History

  Version        Date                         Remarks                     By
   v0.50      23-04-2018                      First draft                 PvW
   v1.00      03-05-2018                    Initial release               PvW
   v2.00      24-05-2018        Updated emission designator on page 7     KR
   v3.00      04-06-2018      Updated channel 1 frequency type error on   KR
                                       page 12, 13, 16 and 17




                                                                               Page 2 of 27


Report number: 180201427 002 v3.00


Table of Contents
Revision History .............................................................................................................................................. 2
Summary of Test results .................................................................................................................................. 5
1      General Description ................................................................................................................................. 6
    1.1        Applicant................................................................................................................................................6
    1.2        Manufacturer ........................................................................................................................................6
    1.3        Tested Equipment Under Test (EUT) .....................................................................................................6
    1.4        Product specifications of Equipment under test ...................................................................................7
    1.5        Modification of the Equipment Under Test (EUT) .................................................................................7
    1.6        Observations and remarks.....................................................................................................................7
    1.7        Environmental conditions......................................................................................................................7
    1.8        Measurement Standards .......................................................................................................................7
    1.9        Applicable Standards .............................................................................................................................7
    1.10       Conclusions ............................................................................................................................................8
2      Test configuration of the Equipment Under Test ..................................................................................... 9
    2.1        Test mode ..............................................................................................................................................9
    2.2        Tested channels and Data rates ............................................................................................................9
    2.3        Test setups .............................................................................................................................................9
    2.4        Equipment used in the test configuration ...........................................................................................10
    2.5        Sample calculation ...............................................................................................................................11
3      Test results ............................................................................................................................................ 12
    3.1        6dB bandwidth Measurement .............................................................................................................12
       3.1.1       Limit.................................................................................................................................................12
       3.1.2       Measurement instruments .............................................................................................................12
       3.1.3       Test setup ........................................................................................................................................12
       3.1.4       Test procedure ................................................................................................................................12
       3.1.5       Test Results of the 6 dB bandwidth Measurement .........................................................................12
    3.2        99% Occupied Bandwidth ....................................................................................................................13
       3.2.1       Limit.................................................................................................................................................13
       3.2.2       Measurement instruments .............................................................................................................13
       3.2.3       Test setup ........................................................................................................................................13
       3.2.4       Test procedure ................................................................................................................................13
       3.2.5       Test results of the 99% occupied bandwidth measurement...........................................................13
       3.2.6       Plots of the 99% occupied bandwidth measurement .....................................................................14
    3.3        Output Power Measurement ..............................................................................................................16
       3.3.1       Limit.................................................................................................................................................16
       3.3.2       Measurement instruments .............................................................................................................16
       3.3.3       Test setup ........................................................................................................................................16


                                                                                                                                                        Page 3 of 27


Report number: 180201427 002 v3.00

    3.3.4      Test procedure ................................................................................................................................16
    3.3.5      Test results of Output Power Measurement...................................................................................16
  3.4       Power Spectral Density........................................................................................................................17
    3.4.1      Limit.................................................................................................................................................17
    3.4.2      Measurement instruments .............................................................................................................17
    3.4.3      Test setup ........................................................................................................................................17
    3.4.4      Test procedure ................................................................................................................................17
    3.4.5      Test results of Power Spectral Density Measurement ....................................................................17
  3.5       Band edge Measurement ....................................................................................................................18
    3.5.1      Limit.................................................................................................................................................18
    3.5.2      Measurement instruments .............................................................................................................18
    3.5.3      Test setup ........................................................................................................................................18
    3.5.4      Test procedure ................................................................................................................................18
    3.5.5      Measurement Uncertainty ..............................................................................................................18
    3.5.6      Plots of the Band edge Measurements ...........................................................................................18
  3.6       Radiated Spurious Emissions Measurement .......................................................................................20
    3.6.1      Limit.................................................................................................................................................20
    3.6.2      Measurement instruments .............................................................................................................20
    3.6.3      Test setup ........................................................................................................................................20
    3.6.4      Test procedure ................................................................................................................................20
    3.6.5      Notes ...............................................................................................................................................20
    3.6.6      Plots of the Radiated Spurious Emissions .......................................................................................21
    3.6.7      Measurement Uncertainty ..............................................................................................................25
  3.7       AC conducted mains measurement ....................................................................................................26
    3.7.1      Limit.................................................................................................................................................26
    3.7.2      Measurement instruments .............................................................................................................26
    3.7.3      Test setup ........................................................................................................................................26
    3.7.4      Test procedure ................................................................................................................................26
    3.7.5      Test results and plots of the AC conducted mains measurement ..................................................26
    3.7.6      Measurement uncertainty ..............................................................................................................26
    3.7.7      Plots of the AC conducted spurious measurement .........................................................................27




                                                                                                                                                    Page 4 of 27


Report number: 180201427 002 v3.00

Summary of Test results
   FCC            ISED         Description                                  Section in      Verdict
                                                                            report
15.247 (a)         --          6dB Bandwidth                                3.1             Pass
    --        RSS-Gen 6.6      99% Bandwidth                                3.2             Pass
15.247 (b)   RSS-247 5.1 (2)   RF output power                              3.3             Pass
15.247 (e)   RSS-247 5.2 (2)   Power spectral density                       3.4             Pass
15.247 (d)    RSS-247 5.5      Band edge                                    3.5             Pass
15.209 (a)    RSS-247 5.4      Radiated Spurious emissions                  3.6             Pass
15.205 (a)    RSS Gen 8.10     Spurious emissions in the restricted bands   3.6             Pass
15.207 (c)    RSS-Gen 8.8      Conducted spurious emissions on AC mains     3.7             Pass




                                                                                         Page 5 of 27


Report number: 180201427 002 v3.00

1     General Description
1.1    Applicant
Client name:                               Feel Robotics B.V.
Address                                    Amstelplein 62, 30th Floor, Amsterdam, the Netherlands
Zip code:                                  1096 BC
Telephone:                                 (0)20 737 1194
E-mail:                                    maurice@kiiroo.com
Contact name:                              Maurice op de Beek

1.2    Manufacturer
Manufacturer name:                         Feel Robotics B.V.
Address:                                   Amstelplein 62, 30th Floor, Amsterdam, the Netherlands
Zip code:                                  1096 BC
Telephone:                                 (0)20 737 1194
E-mail:                                    maurice@kiiroo.com
Contact name:                              Maurice op de Beek

1.3    Tested Equipment Under Test (EUT)
Product name:                              Massager
Brand name:                                Kiiroo
Product type:                              Onyx 3
FCC ID:                                    2AO5N-ONXD18
IC ID                                      23801-ONXD18
Software version:                          --
Hardware version:                          B
Date of receipt                            26-02-2018
Tests started:                             26-02-2018
Testing ended:                             09-03-2018




                                                                                 Page 6 of 27


Report number: 180201427 002 v3.00

1.4       Product specifications of Equipment under test
TX Frequency range (MHz)                          2400 – 2483.5
RX frequency range (MHz)                          2400 – 2483.5
Maximum output power to antenna (dBm)             -0.16
Antenna type                                      PCB antenna
Antenna gain (dBi)                                2.0
Type of modulation                                GFSK
Emission designator BLE                           1M01G1D

1.5       Modification of the Equipment Under Test (EUT)
The manufacturer provided both a radiated sample and a conducted sample for radio testing.

1.6       Observations and remarks
None.

1.7       Environmental conditions
Test date                           26-02-2018                27-02-2018                  09-03-2018
Ambient temperature                   20.9 °C                   20.4 °C                     21.4 °C
Humidity                              27.5 %                    26.6 %                      31.2 %

1.8       Measurement Standards
      •    FCC KDB Publication No. 558074 D01DTS Meas. Guidance V04
      •    ANSI C63.10:2013

1.9       Applicable Standards
According to the specifications of the manufacturer, the EUT must comply with the requirements of the
following standards:

      •    FCC Part 15 Subpart C §15.247, §15.207, §15.209
      •    RSS-247 Issue 1, RSS-Gen Issue 4




                                                                                                Page 7 of 27


Report number: 180201427 002 v3.00

1.10 Conclusions
The sample of the product showed NO NON-COMPLIANCES to the specifications stated in paragraph 1.9 of
this report.

The results of the test as stated in this report, are exclusively applicable to the product items as identified in
this report. Telefication accepts no responsibility for any properties of product items in this test report, which
are not supported by the tests as specified in paragraph 1.9 “Applicable standards”.


All tests are performed by:

Name          : P. van Wanrooij, BASC




Review of test methods and report by:

Name          : ing. R. van Barneveld




The above conclusions have been verified by the following signatory:

Date          : 04-06-2018

Name          : ing. K.A. Roes

Function      : Coordinator Radio Laboratory

Signature     :




                                                                                                     Page 8 of 27


Report number: 180201427 002 v3.00


2     Test configuration of the Equipment Under Test
2.1    Test mode
The applicant provided test mode firmware for the EUT, in which it was possible to configure the EUT into
different test channels.

2.2    Tested channels and Data rates
          Technology                      Channels                 Data rate          Frequency (MHz)
                                           1 (Low)                  1 Mbps                    2402
      Bluetooth Low Energy                18 (Mid)                  1 Mbps                    2440
                                          39 (High)                 1 Mbps                    2480


2.3    Test setups
                                Radiated emissions test setup 30 MHz - 1 GHz




                                 Radiated emissions test setup above 1 GHz




                                                                                                  Page 9 of 27


Report number: 180201427 002 v3.00

                                         Emissions test AC mains




2.4     Equipment used in the test configuration

      Description        Manufacturer                  Model              ID      Used at Par.
Spectrum Analyzer      Rohde & Schwarz                  FSV40           TE01269     3.1, 3.4
Spectrum Analyzer      Rohde & Schwarz                  FSP40           TE11125       3.5
Spectrum Analyzer      Rohde & Schwarz                   ESR7           TE01220     3.5 -3.6
Biconilog Antenna           Chase                     CBL6112A          TE00967       3.5
  Horn Antenna        EMCO The Electro –                3115            TE00531       3.5
                         Mechanics Co
  Horn Antenna         Flann Microwave                20240-25          TE00818       3.5
  SAC Chamber         Comtest Engineering                 -             TE00861       3.5
                              BV
 Band reject filter   5N45-2441/T83-0/0           WHK3.0/18G-10EF       TE00932       3.5
   Pre-amplifier            Miteq              Js4-18004000-30-8P-A1    TE11131       3.5
   Pre-amplifier            Miteq            AFS42-041001800-29-OP-42   TE00092       3.6
     Software          DARE Instruments          Radimation 2016.2.8       --         3.5
     Software          DARE Instruments          Radimation 2017.2.5       --         3.6
  Artificial Mains     Rohde & Schwarz                ESH3-Z5           TE00208       3.6
 Network (AMN)
   Pulse Limiter       Rohde & Schwarz                 ESH3-Z2          TE00756       3.6




                                                                                  Page 10 of 27


Report number: 180201427 002 v3.00

2.5    Sample calculation
Field Strength Measurement example:
Frequency (GHz)          Polarization                 Height(m)   Peak (dBµV/m)
7,236                    Horizontal                   2           52.5

The following relation applies:

E (dBµV/m) = U(dBµV) + AF (dB/m) – G (dB) + CL (dB)

Where:

E = Electric field strength
U = Measuring receiver voltage
AF = Antenna factor
G = Gain of the pre-amplifier
CL = Cable loss

(52.5 = 48.12 + 36.1 - 37.42 + 5.7)




                                                                            Page 11 of 27


Report number: 180201427 002 v3.00

3     Test results
3.1     6dB bandwidth Measurement
3.1.1 Limit
The minimum 6 dB Bandwidth shall be at least 500 kHz.

3.1.2 Measurement instruments
The measurement instruments are listed in chapter 2.4 of this report.

3.1.3 Test setup
The test setup is as shown in chapter 2.3 of this report.

3.1.4 Test procedure
The testing follows FCC KDB Publication No. 558074 D01 DTS Meas. Guidance v04.
IRN 017 - Occupied bandwidth (Hz) Method 4 – DTS Bandwidth.

3.1.5 Test Results of the 6 dB bandwidth Measurement
                                                   Frequency                        6dB bandwidth
      Technology Std.           Channel                                 Data rate
                                                     (MHz)                               (kHz)
                                   1                  2402               1 Mbps         651.6
Bluetooth Low energy               18                 2440               1 Mbps         652.0
                                   39                 2480               1 Mbps         651.0
Uncertainty                                                     ± 36.2 kHz




                                                                                        Page 12 of 27


Report number: 180201427 002 v3.00

3.2        99% Occupied Bandwidth

3.2.1 Limit
According to RSS-Gen 6.6

3.2.2 Measurement instruments
The measurement instruments are listed in chapter 2.4 of this report.

3.2.3 Test setup
The test setup is as shown in chapter 2.3 of this report.

3.2.4 Test procedure
IRN 017 - Occupied bandwidth (Hz) Method 1 – XX % power bandwidth.

      1.    Set the centre frequency to the nominal EUT channel centre frequency
      2.    Set span = 1.5 times to 0.5 times the Occupied Bandwidth
      3.    Set VBW ≥ 3x RBW
      4.    Video averaging is not permitted. Where practical, detection and single sweep mode shall be used.
            Otherwise, peak detection and max hold mode (until the trace stabilizes) shall be used.

3.2.5 Test results of the 99% occupied bandwidth measurement
                                                    Frequency                                99% bandwidth
      Technology Std.            Channel                                  Data rate
                                                      (MHz)                                      (kHz)
                                    1                  2402                1 Mbps                1008
Bluetooth Low energy                18                 2440                1 Mbps                1012
                                    39                 2480                1 Mbps                1008
Uncertainty                                                        ± 12 kHz




                                                                                                   Page 13 of 27


Report number: 180201427 002 v3.00

3.2.6 Plots of the 99% occupied bandwidth measurement
                                     Channel 1




                                                        Page 14 of 27


Report number: 180201427 002 v3.00

                                     Channel 18




                                     Channel 39




                                                  Page 15 of 27


Report number: 180201427 002 v3.00

3.3     Output Power Measurement
3.3.1 Limit
For systems using digital modulation in the 2400-2483.5 MHz, the limit for the peak output power is 30 dBm. If
transmitting antenna of directional gain greater than 6 dBi is used, the peak output power from the intentional
radiator shall be reduced below the above stated value by the amount in dB that the directional gain of the
antenna exceeds 6 dBi. In case of point to point operation, the limit has to be reduced by 1 dB for every 3 dB
that the directional gain of the antenna exceeds 6 dBi.

3.3.2 Measurement instruments
The measurement instruments are listed in chapter 2.4 of this report.

3.3.3 Test setup
The test setup is as shown in chapter 2.3 of this report.

3.3.4 Test procedure
The testing follows FCC KDB Publication No. 558074 D01 DTS Meas. Guidance v04.
IRN 014 - RF power (W) - Method 1 – AVGSA (DTS) according to ANSI C63.10.

3.3.5 Test results of Output Power Measurement
                                                  Peak method
                                                  Frequency                              Peak output power
      Technology Std.           Channel                                 Data rate
                                                    (MHz)                                      (dBm)
                                   1                 2402              1 Mbps                   -1.47
 Bluetooth Low Energy              18                2440              1 Mbps                   -0.53
                                   39                2480              1 Mbps                   -0.16
Uncertainty                                                      ±0.71 dB




                                                                                                  Page 16 of 27


Report number: 180201427 002 v3.00

3.4    Power Spectral Density
3.4.1 Limit
The peak power spectral density shall not be greater than 8 dBm in any 3 kHz band at any time interval of
continuous transmission.

3.4.2 Measurement instruments
The measurement instruments are listed in chapter 2.4 of this report.

3.4.3 Test setup
The test setup is as shown in chapter 2.3 of this report.

3.4.4 Test procedure
The testing follows FCC KDB Publication No. 558074 D01 DTS Meas. Guidance v04.
IRN 030 - Spectral power density (W per n.Hz) - Method 5 – Peak method PKPSD (PSD in 3 kHz band)

3.4.5 Test results of Power Spectral Density Measurement
                                          Peak Power spectral density
                                             Frequency                                      PSD/3 kHz
 Technology Std.           Channel                                 Data rate
                                                (MHz)                                         (dBm)
                              1                  2402               1 Mbps                    -17.69
  Bluetooth Low
                              18                 2440               1 Mbps                    -16.61
      Energy
                              39                 2480               1 Mbps                    -16.61
Uncertainty                                                    ±2 dB




                                                                                                 Page 17 of 27


Report number: 180201427 002 v3.00

3.5    Band edge Measurement
3.5.1 Limit
Band edge:
At the edge of the authorized band the RF power shall be at least 20 dB down.

3.5.2 Measurement instruments
The measurement instruments are listed in chapter 2.4 of this report.

3.5.3 Test setup
The test setup is as shown in chapter 2.3 of this report.

3.5.4 Test procedure
According to KDB Publication 558074 V04, sections 11.3 and 12.1.
IRN 026 - Radiated electrical disturbance (V per m) Method 6 – Radiated electrical disturbance at the
Authorized band edge.

3.5.5 Measurement Uncertainty
± 5.7 dB.

3.5.6 Plots of the Band edge Measurements
See next page




                                                                                                 Page 18 of 27


Report number: 180201427 002 v3.00

                                     BLE Lower band edge (Channel 1)




                                 BLE Upper band edge (Channel 39)




                                                                       Page 19 of 27


Report number: 180201427 002 v3.00

3.6       Radiated Spurious Emissions Measurement
3.6.1 Limit
The emissions from an intentional radiator shall not exceed the field strength levels specified in the
following table:

15.209
          Frequency (MHz)                 Field strength (µV/m)                Measurement distance(m)
            0.009 – 0.490                      2400/F(kHz)                              300
            0.490 – 1.705                      24000/F(kHz)                              30
              1.705 - 30                             30                                  30
                30 -88                              100                                  3
               88 - 216                             150                                  3
               216-960                              200                                  3
             Above 960                              500                                  3


3.6.2 Measurement instruments
The measurement instruments are listed in chapter 2.4 of this report.

3.6.3 Test setup
The test setup is as shown in chapter 2.3 of this report.

3.6.4 Test procedure
The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak
detector except for the frequency bands 9–90 kHz, 110–490 kHz and above 1000 MHz.
Radiated emission limits in these three bands are based on measurements employing an average detector.

Other details are according to KDB Publication 558074 V04, sections 11.3 and 12.1.

IRN 026 - Radiated electrical disturbance (V per m) Method 1 – 30 MHz – 1 GHz in SAR.
IRN 026 - Radiated electrical disturbance (V per m) Method 2 – 1 - 18 GHz in SAR.
IRN 026 - Radiated electrical disturbance (V per m) Method 3 – 18 - 26.5 GHz in SAR.

3.6.5 Notes
      •    In the frequency range of 1 – 26 GHz the green trace is measured using a peak detector and the red
           trace is measured using an average detector. The top limit line represent the peak limit and the
           bottom limit represents the average limit
      •    The peak exceeding the spurious limits at 2.4 GHz in the 1-18 GHz plots is the transmission frequency,
           and therefore not subject to the limit.




                                                                                                    Page 20 of 27


Report number: 180201427 002 v3.00

3.6.6 Plots of the Radiated Spurious Emissions
30 MHz to 1 GHz
                                                                                                                             Vertical polarization
                                                                                       15.209/15.247          RBW: 120 kHz, Vertical Max Peak
                                                                           65


                                                                           60


                                                                           55


                                                                           50


                                                                           45
                                               Electrical Field (dBµV/m)




                                                                           40



    Low ch                                                                 35


                                                                           30


                                                                           25


                                                                           20


                                                                           15


                                                                           10


                                                                           5
                                                                            30 M                   50 M                     100 M                        200 M      300 M      500 M        1G

                                                                                                                                            Frequency (Hz)


                                                                                   15.209/15.247          RBW: 120 kHz, Vertical Max Peak
                                              65


                                              60


                                              55


                                              50


                                              45
                  Electrical Field (dBµV/m)




                                              40


                                              35
    Mid ch
                                              30


                                              25


                                              20


                                              15


                                              10


                                              5
                                               30 M                                         50 M                        100 M                     200 M          300 M      500 M      1G

                                                                                                                                        Frequency (Hz)



                                                                                   15.209/15.247          RBW: 120 kHz, Vertical Max Peak
                                              65


                                              60


                                              55


                                              50


                                              45
                  Electrical Field (dBµV/m)




                                              40


                                              35
    High ch
                                              30


                                              25


                                              20


                                              15


                                              10


                                              5
                                               30 M                                         50 M                        100 M                     200 M          300 M      500 M      1G

                                                                                                                                        Frequency (Hz)




                                                                                                                                                                                                 Page 21 of 27


Report number: 180201427 002 v3.00

30 MHz to 1 GHz
                                                                                    Horizontal polarization
                                                      15.209/15.247    RBW: 120 kHz, Horizontal Max Peak
                                              65


                                              60


                                              55


                                              50


                                              45
                  Electrical Field (dBµV/m)




                                              40



    Low ch                                    35


                                              30


                                              25


                                              20


                                              15


                                              10


                                              5
                                               30 M             50 M                 100 M                     200 M   300 M   500 M   1G

                                                                                                     Frequency (Hz)


                                                      15.209/15.247    RBW: 120 kHz, Horizontal Max Peak



                                              60




                                              50




                                              40
                  Electrical Field (dBµV/m)




    Mid ch                                    30




                                              20




                                              10




                                              0



                                               30 M             50 M                 100 M                     200 M   300 M   500 M   1G

                                                                                                     Frequency (Hz)


                                                      15.209/15.247    RBW: 120 kHz, Horizontal Max Peak



                                              60




                                              50




                                              40
                  Electrical Field (dBµV/m)




    High ch                                   30




                                              20




                                              10




                                              0



                                               30 M             50 M                 100 M                     200 M   300 M   500 M   1G

                                                                                                     Frequency (Hz)




                                                                                                                                            Page 22 of 27


Report number: 180201427 002 v3.00

1 GHz to 18 GHz
                                                                                                Vertical polarization
                                                        Limit Average 1 - 18 GHz         Limit Peak 1 - 18 GHz           RBW: 1 MHz, Vertical Max Average
                                                        RBW: 1 MHz, Vertical Max Peak


                                              90


                                              80


                                              70
                  Electrical Field (dBµV/m)




                                              60



    Low ch                                    50


                                              40


                                              30


                                              20


                                              10



                                               1G                              2G                   3G                        5G                             10 G   18 G

                                                                                                                 Frequency (Hz)


                                                         Limit Average 1 - 18 GHz         Limit Peak 1 - 18 GHz           RBW: 1 MHz, Vertical Max Average
                                                         RBW: 1 MHz, Vertical Max Peak


                                              100


                                              90


                                              80


                                              70
                  Electrical Field (dBµV/m)




                                              60

    Mid ch
                                              50


                                              40


                                              30


                                              20


                                              10



                                                   1G                           2G                   3G                           5G                         10 G   18 G

                                                                                                                 Frequency (Hz)


                                                        Limit Average 1 - 18 GHz         Limit Peak 1 - 18 GHz           RBW: 1 MHz, Vertical Max Average
                                                        RBW: 1 MHz, Vertical Max Peak


                                              90


                                              80


                                              70
                  Electrical Field (dBµV/m)




                                              60



    High ch                                   50


                                              40


                                              30


                                              20


                                              10



                                               1G                              2G                   3G                        5G                             10 G   18 G

                                                                                                                 Frequency (Hz)




                                                                                                                                                                           Page 23 of 27


Report number: 180201427 002 v3.00

1 GHz to 18 GHz
                                                                                        Horizontal polarization
                                                     Limit Average 1 - 18 GHz        Limit Peak 1 - 18 GHz        RBW: 1 MHz, Horizontal Max Average
                                                     RBW: 1 MHz, Horizontal Max Peak


                                              100


                                              90


                                              80


                                              70
                  Electrical Field (dBµV/m)




                                              60

    Low ch
                                              50


                                              40


                                              30


                                              20


                                              10



                                                1G                          2G                  3G                        5G                           10 G   18 G

                                                                                                         Frequency (Hz)


                                                     Limit Average 1 - 18 GHz        Limit Peak 1 - 18 GHz        RBW: 1 MHz, Horizontal Max Average
                                                     RBW: 1 MHz, Horizontal Max Peak


                                              100


                                              90


                                              80


                                              70
                  Electrical Field (dBµV/m)




                                              60

    Mid ch
                                              50


                                              40


                                              30


                                              20


                                              10



                                                1G                          2G                  3G                        5G                           10 G   18 G

                                                                                                         Frequency (Hz)


                                                     Limit Average 1 - 18 GHz        Limit Peak 1 - 18 GHz        RBW: 1 MHz, Horizontal Max Average
                                                     RBW: 1 MHz, Horizontal Max Peak


                                              100


                                              90


                                              80


                                              70
                  Electrical Field (dBµV/m)




                                              60

    High ch
                                              50


                                              40


                                              30


                                              20


                                              10



                                                1G                          2G                  3G                        5G                           10 G   18 G

                                                                                                         Frequency (Hz)




                                                                                                                                                                     Page 24 of 27


Report number: 180201427 002 v3.00

18 GHz to 26 GHz


                                                         Limit Average 18 - 26 GHz         Limit Peak 18 - 26 GHz          RBW: 100 kHz, Vertical Max Average
                                                         RBW: 100 kHz, Vertical Max Peak
                                                 85


                                                 80


                                                 75


                                                 70


                                                 65
                     Electrical Field (dBµV/m)




      Vertical                                   60

    polarization                                 55


                                                 50
       Mid ch
                                                 45


                                                 40


                                                 35


                                                 30


                                                 25
                                                  18 G             19 G               20 G                21 G              22 G            23 G            24 G   25 G     26 G

                                                                                                                 Frequency (Hz)


                                                         Limit Average 18 - 26 GHz        Limit Peak 18 - 26 GHz           RBW: 100 kHz, Horizontal Max Average
                                                         RBW: 100 kHz, Horizontal Max Peak
                                                 85


                                                 80


                                                 75


                                                 70


                                                 65
                     Electrical Field (dBµV/m)




     Horizontal                                  60

    polarization                                 55


                                                 50
       Mid ch
                                                 45


                                                 40


                                                 35


                                                 30


                                                 25
                                                  18 G             19 G               20 G                21 G              22 G            23 G            24 G   25 G     26 G

                                                                                                                 Frequency (Hz)



3.6.7 Measurement Uncertainty
Measurement uncertainty Radiated emissions below 1 GHz
                          Horizontal polarization
         30 – 200 MHz                                4.5 dB
        200 – 1000 MHz                               3.6 dB
                           Vertical polarization
         30 – 200 MHz                                5.4 dB
        200 – 1000 MHz                               4.6 dB

Measurement uncertainty Radiated emissions above 1 GHz
        1000- 18000 MHZ                              5.7 dB
       18000 – 26000 MHZ                             3.9 dB




                                                                                                                                                                          Page 25 of 27


Report number: 180201427 002 v3.00

3.7    AC conducted mains measurement
3.7.1 Limit
According to 15.207 (c)

An intentional radiator that is designed to be connected to the public utility (AC) power line, the radio
frequency voltage that is conducted back onto the AC power line on any frequency or frequencies,
within the band 150 kHz to 30 MHz, shall not exceed the limits in the following table.




3.7.2 Measurement instruments
The measurement instruments are listed in chapter 2.4 of this report.

3.7.3 Test setup
The test setup is as shown in chapter 2.3 of this report.

3.7.4 Test procedure
According to ANSI C63.4: 2014, section 13.3.
IRN 029 - Conducted disturbance (V) Method 1 – AC mains conducted disturbance.

3.7.5 Test results and plots of the AC conducted mains measurement
The EUT normally receives power from another device that in turn connects to the public-utility ac power lines,
therefore the measurements are made with a representative charger with the EUT in operation to ensure that
the device continues to comply with the appropriate limits while providing the EUT with power.

The test results can be found on the next page.

3.7.6 Measurement uncertainty
+/- 3.6 dB.




                                                                                                     Page 26 of 27


Report number: 180201427 002 v3.00

3.7.7 Plots of the AC conducted spurious measurement

Phase


                               15.207      15.207 avg         RBW: 9 kHz, Line 1 Max Average       RBW: 9 kHz, Line 1 Max Peak




                      80




                      70




                      60




                      50
    Voltage (dBµV)




                      40




                      30




                      20




                      10




                      0




                       150 k            300 k           500 k 600 k             1M                  2M            3M                5M   10 M   20 M    30 M

                                                                                                Frequency (Hz)




Neutral


                               15.207      15.207 avg         RBW: 9 kHz, Neutral Max Average        RBW: 9 kHz, Neutral Max Peak




                      80




                      70




                      60




                      50
     Voltage (dBµV)




                      40




                      30




                      20




                      10




                      0




                       150 k            300 k           500 k 600 k             1M                  2M            3M                5M   10 M   20 M    30 M

                                                                                                Frequency (Hz)




                                                                                                                                                   Page 27 of 27



Document Created: 2019-09-23 09:23:56
Document Modified: 2019-09-23 09:23:56

© 2024 FCC.report