Test Report

FCC ID: 2AO23-2210

Test Report

Download: PDF
FCCID_4355528

                                  SGS-CSTC Standards Technical Services Co., Ltd.
                                  Shenzhen Branch




                                                                     Report No.: SZEM190601543301
                                                                     Page:        1 of 26


                                    TEST REPORT
Application No.:                SZEM1906015433CR
Applicant:                      Chug, Inc.
Address of Applicant:           7157 Shady Oak Road Eden Prairie, Washington, Minnesota, United States
                                55344
Manufacturer:                   HANK Electronics Co., Ltd.
Address of Manufacturer:        Floor 2nd-7th, A8, Hongye Industry City, Lezhujiao, Zhoushi Road, Baoan
                                District, Shenzhen, China 518101
Equipment Under Test (EUT):
EUT Name:                       Stand wireless charger
Model No.:                      QIC-30, QIC-30S, QIC-30E ♣
♣                               Please refer to section 2 of this report which indicates which model was
                                actually tested and which were electrically identical.
Trade mark:                     Heyday
FCC ID:                         2AO23-2210
Standard(s) :                   47 CFR Part 15, Subpart C 15.209
Date of Receipt:                2019-06-20
Date of Test:                   2019-06-21 to 2019-06-27
Date of Issue:                  2019-07-01
Test Result:                    Pass*
* In the configuration tested, the EUT complied with the standards specified above.




             Keny Xu
       EMC Laboratory Manager


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                           Report No.: SZEM190601543301
                                                           Page:       2 of 26



                                        Revision Record
     Version       Chapter               Date                 Modifier       Remark

     01                              2019-07-01                              Original




Authorized for issue by:




                             Bill Chen /Project Engineer




                             Eric Fu /Reviewer


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                 Report No.: SZEM190601543301
                                                                 Page:       3 of 26



2   Test Summary
    Radio Spectrum Technical Requirement
             Item               Standard               Method                 Requirement           Result
                            47 CFR Part 15,                             47 CFR Part 15, Subpart
    Antenna Requirement                                  N/A                                         Pass
                               Subpart C                                      C 15.203


    Radio Spectrum Matter Part
             Item               Standard               Method                 Requirement           Result
    Conducted Emissions
                            47 CFR Part 15,      ANSI C63.10 (2013)     47 CFR Part 15, Subpart
     at AC Power Line                                                                                Pass
                               Subpart C            Section 6.2               C 15.207
      (150kHz-30MHz)
                            47 CFR Part 15,      ANSI C63.10 (2013)     47 CFR Part 15, Subpart
       20dB Bandwidth                                                                                Pass
                               Subpart C           Section 6.9.2              C 15.215
                            47 CFR Part 15,      ANSI C63.10 (2013)     47 CFR Part 15, Subpart
      Restricted Bands                                                                               Pass
                               Subpart C           Section 6.10.5             C 15.205
     Radiated Emissions     47 CFR Part 15,      ANSI C63.10 (2013)     47 CFR Part 15, Subpart
                                                                                                     Pass
       (9kHz-30MHz)            Subpart C            Section 6.4            C 15.205 & 15.209
     Radiated Emissions     47 CFR Part 15,      ANSI C63.10 (2013)     47 CFR Part 15, Subpart
                                                                                                     Pass
       (30MHz-1GHz)            Subpart C            Section 6.5            C 15.205 & 15.209

    Declaration of EUT Family Grouping:

    Model No.: QIC-30, QIC-30S, QIC-30E

    Only the model QIC-30 was tested, since the electrical circuit design, layout, components used, internal
    wiring and functions were identical for the above models, with only difference on model No..


                                                             SGS—CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch

                                                                                                                               Report No.: SZEM190601543301
                                                                                                                               Page:                    4 of 26



3            Contents
                                                                                                                                                                                              Page
            COVER PAGE ...... .. 0nmeneneenmeerreernerrernernerrneennerrrerennerenerennerenerennereeenerennenerennenen en en nnenenennnnenenennnnennn en en nne 1
2           TEST SUMMARY .........ncmmmmmmmeermirirremireeemereeermereeemereerenmerereerenmeeeenmeneeereerenneereerenneeneerennennner en3
3           CONTENTS ... .c cccmmmmmnneenmireieeireeemireeemereeenmereeremereerenenmereenmeereerenmeneeereerenmeereerenneeneerennennerneee 4
4           GENERAL INFORMATION .......... .nn mmeemmmrreermireeermereeemereeermereeenmerereeeeeeereerenmeereerenmeereerenmeereer en 5
      4.1           DETAILS OF EULT : iescs




                                                                                                                                                                                                 a o o o in in in
      4.2           DescRiPtion oF Support Units
      4.3           MEASUREMENT UNCERTAINTY .
      4.4           TEST LOCATION: :scc
      4.5           TEST FACIUITY enc
      4.6           DEVIATION FROM STANDARDS..                                                                                               .
      4.7           ABNORMALITIES FROM STANDARD CONDITIONS 1. ... ... ce ce eenee en en n en eeneneneneneeneeneneneeneneneneenenenenennenen ns

5           EQUIPMENT LIST ...... .0 ce e000 00e 09e erereerererereerererereerererereerenerereenen en en nenenenenen en en nennen en en nenenevnenenenevnenenennevene 7

6           RADIO SPECTRUM TECHNICAL REQUIREMENT .........ccececneeneneneremernenenerernenennenerernenenenenerneneneenenenennenene 9
      6.1           ANTENNA REQUIREMENT .. ... e e mm en rn en en n en en en nen en en n en en n n eneere n n en en n en enenneneneneneenenenennnnenenene 9
            6.1.1       Test Requirement:
            6.1.2        Conclusion ..
7           RADIO SPECTRUM MATTER TEST RESULTS ... .. cce ccecnemmeemmenememernenenerernenenereenernenenenenerneneneenenenennenenen 10
      7.1           Conbuctep Emissions at AC Power Linge (150KkHz—30MHz).                                                                                                                    «... 10
            7.1.1       EU.T. OD@ANION........cccccmmemerememereerememernerenememenenne                                                                                                         11
            7.1.2       Test SQ@tup Di@QIAM ...                                                                                                                                               2211
            7.1.3     Measurement Procedure and Data                                                                                                                                             411
      7.2           200B BANDWIDTH.....                                                                                                                                                          A4
            7.2.1       E.U.T. Operation.                                                                                                                                                        .14
            7.2.2        Test Setup Diagram.                                                                                                                                                     .14
            7.2.3     Measurement Procedure and Data                                                                                                                                             .14
      7.3           ResTRICTED BANDS ..                                                                                                                                                          16
            7.3.1       E.U.T. Operation...                                                                                                                                                      16
            7.3.2        Test Setup Diagram.                                                                                                                                                     16
            7.3.3     Measurement Procedure and Data                                                                                                                                             .16
      7.4           RADIATED EMISSIONS (OKHz—30MHz).......                                                                                                                                    ... 18
            7.4.1       E.U.T. Operation......                                                                                                                                                ... 19
            7.4.2       Test Setup Diagram.                                                                                                                                                   ... 19
            7.4.3       Measurement Procedure and Data...                                                                                                                                       .. 19
      7.5           RADIATED EMISSIONS (3OMHz—1GHz) ......                                                                                                                                    ....22
            7.5.1     EU.T. Operation......                                                                                                                                                   ... 22
            7.5.2        Test Setup Diagram.                                                                                            ... 22
            7.5.3       M@ASUF@M@Nt PrOCB@UU@ @MQ DBIA.............ccccceceeeeeerememeemerenemeenerenereenerneneneneneeneneneenenenenereene 23


      8.1           TEST SETUP ... cce en en n en en en en eeneneneneeneneneneeneneneneeneneneneeneneneneeneneneneneeneeneneneeveneneneevenenenennenen ns 26
      8.2           EUT CONSTRUCTIONAL DETAILS (EUT PHOTOS) :. . .000 en en en en eererer en eerenene reveeneneneneeneneneneenenenen en 26
                                            Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                            overleaf, available on request or accessible at h“g://www.sgs.com/en/Terms-and-Cnndilrons.asQ{x and, for electronic format documents,
                                            subject to Terms and Conditions for Electronic Documents at hiip:/wwnw.sgs.com/en/Terms—and—Gonditions/Terms—e—Document.aspx.
                                            Attention is drawn to the limitation of lability, indomnification and jurlsdiction Issues defined therein, Any holder of this document is
                                            advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                            Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exoncrate parties to a
                                            fransaction from excreising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                            except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
                                            appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless othenwise stated the
                                            results shown in this test report refer only to the sample() tested and such sample(s) are retained for 30 days only.
                                            Aftention: To check the authenticity of testing /inspection report & cortificate, please contact us at telophone: (B6—755) 8307 1443,
        s                                   or email: CN.Doecheck@sgs.com
    S6SCS                              4.       [No— Woristop, —10, MiddlSecion, Scence & Technology PShanthen, China 518057   t (86—768)26012053 1 (%6—768)26710504    wnnwsgsgroup.com.en
    StenwhenBoan             "ahooky            B —Ril— HARREM—108—S1 6                                        #B4i: 518057    t (€6—755)26012050 f (@6—755) 26710504   sgs:china@sgs.com
                                            t
                                                                                                                                                 Member of the SGS Group (SGS SA)


                                                          SGS—CSTC Standards Technical Services Co., Ltd.
                                                          Shenzhen Branch

                                                                                                                                Report No.: SZEM190601543301
                                                                                                                                Page:       5 of 26


4       General Information
4.1     Details of E.U.T.
        Power supply:                                    Model:HKAP1231Q
                                                         Input: AC 100—240V 50/60Hz 0.5A Max
                                                         Output: DC 5V/3.0A,9V/2A,12V/1.5A
                                                         Wireless Charger:
                                                         Input: DC 5V/2A,9V/1.7A, 12V/1.25A
                                                         OQOutput:1OW
        Cable:                                           USB cable: 175¢cm unshielded
        Operation Frequency:                             126.282kHz to 128.686kHz
        Modulation Type:                                 Load Modulation
        Antenna Type:                                    Loop Antenna
        Antenna Gain:                                    OdBi
        Remark:                                          Tests were conducted in all three load modes and the worst case (DC 9V,
                                                         1.7A) is reported only.


4.2 Description of Support Units

        Description                                             Manufacturer                                             Model No.                                       Serial No.
        Mobile Phone                                                  SAMSUNG                                            SM—G9500                                       R28J9140LPB
             iPhone 8                                                    Apple                                                 A1863                              F4GVQbSEJCGD


4.3     Measurement Uncertainty

            No.                                                        Item                                                             Measurement Uncertainty
               1                                       Conduction emission                                                             + 3.0dB (150kHz to 30MHz)
                                                                  .                20.                                                      + 4.5dB (9kHz—30MHz)
              2                                           Radiated emission
                                                                                                                                           + 4.50B (3OMHz—1GHz)
              3                                            Restricted Bands                                                                                +3%
              4                                             200B Bandwidth                                                                                 +3%
              5                                            Temperature test                                                                                £1°C
              6                                                Humidity test                                                                               +3%




                                        Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                        overleaf, available on request or accessible at hitp/waw.sas..comen/Terms—and—Conditions.aspx and, for electronic format documents,
                                        Subject to Terms and Gonditions for Electronte Documents at hylwim sgs. comfenTerms—ang:Condiions/erms.6.booument aspx.
                                        Attention is drawn to the limitation of lability, indamnification and jurlsdiction issues defined tharein. Any holder of this document is
                                        advised that information contained hereon raflects the Company‘s findings at the time of ts intervention only and within the limits of
                                        Clients instructions, if any. The Company‘s sole responsibiity is to its Client and this document does not exoncrate parties to a
                                        fransaction from exereising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                        except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
           olEie 7.
      a Inpecton                        appearance of this documentis unlawful and offendars may be prosecuted to the fullest extent of the law. Unlss othenwise stated the
                                        results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                 d TesingSevices        Aftention: To check the authenticity of testing /inspection report & certificate, please contact us at télophone: (86—755) 8307 1443,
                                        or email: CN.Doecheck@sgs.com
                                   5.       [No—t Woristep,N—1, Middl Secion,Scence & Technology Part Shenthen, China 518057   t (86—756)26012053 1 (%6—759) 26710504    wnnwcsgegroup.com.en
                                            hB «BRABRdEN—108—S1 B                                           #B4i: 518057       t (€6—755)26012050 f (@6—755) 26710504    sgs:china@sgs.com
                                        t
                                                                                                                                                 Member of the SGS Group (SGS SA)


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                               Report No.: SZEM190601543301
                                                               Page:       6 of 26


4.4 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
    No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
    518057.
    Tel: +86 755 2601 2053        Fax: +86 755 2671 0594
    No tests were sub-contracted.
4.5 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.
4.6 Deviation from Standards
    None
4.7 Abnormalities from Standard Conditions
    None


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                 Report No.: SZEM190601543301
                                                                 Page:       7 of 26



5      Equipment List
Conducted Emissions at AC Power Line (150kHz-30MHz)
       Equipment           Manufacturer          Model No      Inventory No    Cal Date    Cal Due Date
     Shielding Room      ZhongYu Electron         GB-88        SEM001-06      2019-06-13    2024-06-12
Measurement Software          AUDIX            e3 V5.4.1221d       N/A           N/A           N/A
      Coaxial Cable            SGS                 N/A         SEM024-01      2018-07-12    2019-07-11
          LISN           Rohde & Schwarz         ENV216        SEM007-01      2018-09-25    2019-09-24
          LISN            ETS-LINDGREN            3816/2       SEM007-02      2019-04-01    2020-03-31
    EMI Test Receiver    Rohde & Schwarz           ESCI        SEM004-02      2019-04-01    2020-03-31


20dB Bandwidth
       Equipment           Manufacturer          Model No      Inventory No    Cal Date    Cal Due Date
    DC Power Supply           ZhaoXin           RXN-305D       SEM011-02      2018-09-25    2019-09-24
    Spectrum Analyzer    Rohde & Schwarz           FSP         SEM004-06      2018-09-27    2019-09-26
                                                 JS1120-2
Measurement Software        JS Tonscend                            N/A           N/A           N/A
                                                BT/WIFI V2.
      Coaxial Cable            SGS                 N/A         SEM031-02      2018-07-12    2019-07-11
        Attenuator      Weinschel Associates      WA41         SEM021-09         N/A           N/A
     Signal Generator       KEYSIGHT             N5173B        SEM006-05      2018-09-27    2019-09-26
       Power Meter       Rohde & Schwarz          NRVS         SEM014-02      2018-09-25    2019-09-24


Restricted Bands Measurement
       Equipment           Manufacturer          Model No      Inventory No    Cal Date    Cal Due Date
    DC Power Supply           ZhaoXin           RXN-305D       SEM011-02      2018-09-25    2019-09-24
    Spectrum Analyzer    Rohde & Schwarz           FSP         SEM004-06      2018-09-27    2019-09-26
                                                 JS1120-2
Measurement Software        JS Tonscend                            N/A           N/A           N/A
                                                BT/WIFI V2.
      Coaxial Cable            SGS                 N/A         SEM031-02      2018-07-12    2019-07-11
        Attenuator      Weinschel Associates      WA41         SEM021-09         N/A           N/A
     Signal Generator       KEYSIGHT             N5173B        SEM006-05      2018-09-27    2019-09-26
       Power Meter       Rohde & Schwarz          NRVS         SEM014-02      2018-09-25    2019-09-24


Radiated Emissions (9kHz-30MHz)
       Equipment           Manufacturer          Model No      Inventory No    Cal Date    Cal Due Date
    10m Semi-Anechoic
                              SAEMC             FSAC1018       SEM001-03      2018-03-31    2021-03-30
        Chamber
                                               e3 V8.2014-6-
Measurement Software          AUDIX                                N/A           N/A           N/A
                                                    27
      Coaxial Cable            SGS                 N/A         SEM029-01      2018-07-12    2019-07-11
    EMI Test Receiver
                         Rohde & Schwarz           ESR         SEM004-03      2019-04-01    2020-03-31
      (9kHz-7GHz)


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                 Report No.: SZEM190601543301
                                                                 Page:       8 of 26

   Trilog-Broadband
        Antenna            Schwarzbeck          VULB9168       SEM003-18       2019-02-22    2022-02-21
    (30MHz-1GHz)
                         Sonoma Instrument
     Pre-amplifier                                 310N        SEM005-04       2019-04-12    2020-04-11
                               Co
 Active Loop Antenna       ETS-Lindgren            6502        SEM003-08       2017-08-22    2020-08-21

Radiated Emissions (30MHz-1GHz)
    Test Equipment        Manufacturer          Model No.      Inventory No.    Cal. Date   Cal. Due date
 3m Semi-Anechoic
                         ETS-LINDGREN             N/A          SEM001-01       2017-08-05    2020-08-04
      Chamber
 MXE EMI Receiver            Agilent
                                                N9038A         SEM004-05       2018-09-25    2019-09-24
   (20Hz-8.4GHz)          Technologies
 BiConiLog Antenna
                         ETS-LINDGREN            3142C         SEM003-01       2017-06-27    2020-06-26
   (26-3000MHz)
    Pre-amplifier            Agilent
                                                 8447D         SEM005-01       2019-04-01    2020-03-31
   (0.1-1300MHz)          Technologies
Measurement Software         AUDIX           e3 V8.2014-6-27       N/A            N/A           N/A
    Coaxial Cable             SGS                 N/A          SEM025-01       2018-07-12    2019-07-11


General used equipment
     Equipment             Manufacturer         Model No       Inventory No     Cal Date    Cal Due Date
                             Shanghai
Humidity/ Temperature
                           Meteorological         ZJ1-2B       SEM002-03       2018-09-27    2019-09-26
      Indicator
                          Industry Factory
                             Shanghai
Humidity/ Temperature
                           Meteorological         ZJ1-2B       SEM002-04       2018-09-27    2019-09-26
      Indicator
                          Industry Factory
Humidity/ Temperature
                              Mingle               N/A         SEM002-08       2018-09-27    2019-09-26
      Indicator
                            Changchun
      Barometer            Meteorological         DYM3         SEM002-01       2019-04-04    2020-04-03
                          Industry Factory


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                  Report No.: SZEM190601543301
                                                                  Page:       9 of 26



6    Radio Spectrum Technical Requirement
6.1 Antenna Requirement
6.1.1 Test Requirement:
      47 CFR Part 15, Subpart C 15.203

6.1.2 Conclusion
      Standard Requirement:
      An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
      responsible party shall be used with the device. The use of a antenna that uses a unique coupling to
      the intentional radiator, the manufacturer may design the unit permanently attached antenna or of an
      so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
      electrical connector is prohibited.

      EUT Antenna:

      The antenna is integrated on the main PCB and no consideration of replacement. The best case gain
      of the antenna is 0dBi.

      Antenna location: Refer to Appendix(Internal photos)


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                   Report No.: SZEM190601543301
                                                                   Page:       10 of 26



7     Radio Spectrum Matter Test Results
7.1 Conducted Emissions at AC Power Line (150kHz-30MHz)
      Test Requirement         47 CFR Part 15, Subpart C 15.207
      Test Method:             ANSI C63.10 (2013) Section 6.2
      Limit:

                                                          Conducted limit(dBμV)
Frequency of emission(MHz)
                                            Quasi-peak                            Average
            0.15-0.5                          66 to 56*                           56 to 46*
             0.5-5                                56                                 46
             5-30                                 60                                 50
*Decreases with the logarithm of the frequency.


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                   Report No.: SZEM190601543301
                                                                   Page:       11 of 26




7.1.1 E.U.T. Operation
      Operating Environment:
      Temperature:      22.1 °C      Humidity: 55.6 % RH           Atmospheric Pressure: 1010         mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.1.2 Test Setup Diagram




7.1.3 Measurement Procedure and Data
      1) The mains terminal disturbance voltage test was conducted in a shielded room.
      2) The EUT was connected to AC power source through a LISN 1 (Line Impedance Stabilization
      Network) which provides a 50ohm/50μH + 5ohm linear impedance. The power cables of all other
      units of the EUT were connected to a second LISN 2, which was bonded to the ground reference
      plane in the same way as the LISN 1 for the unit being measured. A multiple socket outlet strip was
      used to connect multiple power cables to a single LISN provided the rating of the LISN was not
      exceeded.
      3) The tabletop EUT was placed upon a non-metallic table 0.8m above the ground reference plane.
      And for floor-standing arrangement, the EUT was placed on the horizontal ground reference plane,
      4) The test was performed with a vertical ground reference plane. The rear of the EUT shall be 0.4 m
      from the vertical ground reference plane. The vertical ground reference plane was bonded to the
      horizontal ground reference plane. The LISN 1 was placed 0.8 m from the boundary of the unit under
      test and bonded to a ground reference plane for LISNs mounted on top of the ground reference
      plane. This distance was between the closest points of the LISN 1 and the EUT. All other units of the
      EUT and associated equipment was at least 0.8 m from the LISN 2.
      5) In order to find the maximum emission, the relative positions of equipment and all of the interface
      cables must be changed according to ANSI C63.10 on conducted measurement.
      Remark: LISN=Read Level+ Cable Loss+ LISN Factor


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Shenzhen Branch
                                               Report No.: SZEM190601543301
                                               Page:       12 of 26



Mode:a; Line:Live Line


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                  Report No.: SZEM190601543301
                                                  Page:       13 of 26



Mode:a; Line:Neutral Line


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                Report No.: SZEM190601543301
                                                                Page:       14 of 26



7.2 20dB Bandwidth
     Test Requirement        47 CFR Part 15, Subpart C 15.215
     Test Method:            ANSI C63.10 (2013) Section 6.9.2
     Limit:                  N/A

7.2.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C        Humidity: 51 % RH             Atmospheric Pressure: 1010    mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.2.2 Test Setup Diagram




7.2.3 Measurement Procedure and Data
     Test Frequency(KHz)            20dB bandwidth (KHz)                Limit (KHz)             Results
              127.492                       0.026                          N/A                   Pass


                                    SGS-CSTC Standards Technical Services Co., Ltd.
                                    Shenzhen Branch
                                                                           Report No.: SZEM190601543301
                                                                           Page:       15 of 26

                                                         * RBW 10 Hz     Marker 1 [T1 ]
                                                         * VBW 30 Hz               -41.25 dBm
       Ref -10 dBm                * Att    10 dB          SWT 1 s           127.492307692 kHz

       -10                                                               ndB [T1]   20.00   dB
                                                                         BW 25.961538462    Hz
       -20
                                                                         Temp 1 [T1 ndB]          A
                                                                                   -61.12   dBm
1 PK                                                                        127.479487179   kHz
VIEW
       -30                                                               Temp 2 [T1 ndB]
                                                                                   -61.34   dBm
                                                     1                      127.505448718   kHz
       -40



       -50


                                          T1                        T2
       -60

                                                                                                  3DB
       -70



       -80



       -90



       -100


       -110

       Center   127.4923077 kHz                    10 Hz/                        Span   100 Hz


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                               Report No.: SZEM190601543301
                                                               Page:       16 of 26



7.3 Restricted Bands
     Test Requirement        47 CFR Part 15, Subpart C 15.205
     Test Method:            ANSI C63.10 (2013) Section 6.10.5
     Limit:                  The fundamental wave can not fall in the restricted band 90KHz-110KHz



7.3.1 E.U.T. Operation
      Operating Environment:
      Temperature:      56.3 °C      Humidity: 58.6 % RH           Atmospheric Pressure: 1020    mbar
      Test mode:        a:TX mode_Keep the EUT in transmitting with modulation mode.
7.3.2 Test Setup Diagram




7.3.3 Measurement Procedure and Data


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                                   Report No.: SZEM190601543301
                                                                   Page:       17 of 26



                                                   * RBW 1 kHz   Marker 1 [T1 ]
                                                   * VBW 3 kHz             -29.09 dBm
       Ref    0 dBm            * Att   10 dB        SWT 100 ms      127.564102564 kHz

       0                                                         OBW 2.403846154    kHz
                                                                 Temp 1 [T1 OBW]
       -10                                                                 -44.12   dBm   A
                                                                    126.282051282   kHz
1 PK                                                             Temp 2 [T1 OBW]
VIEW
       -20                                                                 -44.15   dBm
                                                                    128.685897436   kHz
                           1
       -30



       -40                T1T2


       -50

                                                                                          3DB
       -60



       -70



       -80



       -90


       -100

       Center   150 kHz                        10 kHz/                  Span   100 kHz




According the test data above, the fundamental wave is not fall in the restricted band 90KHz-110KHz, the
field strength also meet the 15.209 requirement, so this test is Pass.


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                                              Report No.: SZEM190601543301
                                                                              Page:       18 of 26



7.4 Radiated Emissions (9kHz-30MHz)
      Test Requirement      47 CFR Part 15, Subpart C 15.237(c)
      Test Method:          ANSI C63.10 (2013) Section 6.4&6.5
      Measurement Distance: 10m
      Limit:

       Frequency(MHz)                Field strength(microvolts/meter)                 Measurement distance(meters)
          0.009-0.490                              2400/F(kHz)                                          300
          0.490-1.705                             24000/F(kHz)                                           30
          1.705-30.0                                     30                                              30
             30-88                                       100                                              3
            88-216                                       150                                              3
            216-960                                      200                                              3
           Above 960                              500                                 3
Remark: The emission limits shown in the above table are based on measurements employing a CISPR
quasi-peak detector except for the frequency bands 9-90kHz, 110-490kHz and above 1000 MHz. Radiated
emission limits in these three bands are based on measurements employing an average detector, the peak
field strength of any emission shall not exceed the maximum permitted average limits specified above by
more than 20 dB under any condition of modulation.

If field strength is measured at only a single point, then that point shall be at the radial from the EUT that
produces the maximum emission at the frequency being measured, as described in 5.4. If that point is closer
to the EUT than λ/2π and the limit distance is greater than λ/2π, the measurement shall be extrapolated to
the limit distance by conservatively presuming that the field strength decreases at a 40 dB/decade of distance
rate to the λ/2π distance, and at a 20 dB/decade of distance rate beyond λ/2π. This shall be accomplished
using Equation (2):

                         FS(10m) = FS(30/300m) + 40log{d(near field)/d(10m)} + 20log{d(30/300m)/d(near field)}   (2)

If the single point measured is at a distance greater than λ/2π, then extrapolation to the limit distance shall be
calculated using Equation (3):

                         FS(10m) = FS(30/300m) + 20log{d(30/300m)/d(10m)}                                        (3)

If both the single point and the limit distance are equal to or closer to the EUT than λ/2π, then extrapolation to
the limit distance shall be calculated using Equation (4):

                         FS(10m) = FS(30/300m) + 40log{d(30/300m)/d(10m)}                                        (4)

Remark:
                       dnear field = 47.77 / fMHz
where fMHz is the frequency of the emission being measured in MHz.


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                   Report No.: SZEM190601543301
                                                                   Page:       19 of 26


7.4.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C        Humidity: 51 % RH             Atmospheric Pressure: 1010         mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.4.2 Test Setup Diagram




7.4.3 Measurement Procedure and Data
      For testing performed with the loop antenna, the center of the loop was positioned 1 m above the
      ground and positioned with its plane vertical at the specified distance from the EUT. During testing
      the loop was rotated about its vertical axis for maximum response at each azimuth and also
      investigated with the loop positioned in the horizontal plane. Only the worst position of vertical was
      shown in the report.


              SGS-CSTC Standards Technical Services Co., Ltd.
              Shenzhen Branch
                                    Report No.: SZEM190601543301
                                    Page:       20 of 26

Mode a:
9kHz-150kHz


               SGS-CSTC Standards Technical Services Co., Ltd.
               Shenzhen Branch
                                     Report No.: SZEM190601543301
                                     Page:       21 of 26

150kHz-30MHz


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                Report No.: SZEM190601543301
                                                                Page:       22 of 26



7.5 Radiated Emissions (30MHz-1GHz)
     Test Requirement      47 CFR Part 15, Subpart C 15.237(c)
     Test Method:          ANSI C63.10 (2013) Section 6.4&6.5
     Measurement Distance: 10m
     Limit:
      Frequency(MHz)             Field strength(microvolts/meter)     Measurement distance(meters)
         0.009-0.490                        2400/F(kHz)                             300
         0.490-1.705                       24000/F(kHz)                              30
         1.705-30.0                             30                                   30
            30-88                               100                                   3
           88-216                               150                                  3
           216-960                              200                                  3
           Above 960                              500                                 3
Remark: The emission limits shown in the above table are based on measurements employing a CISPR
quasi-peak detector except for the frequency bands 9-90kHz, 110-490kHz and above 1000 MHz. Radiated
emission limits in these three bands are based on measurements employing an average detector, the peak
field strength of any emission shall not exceed the maximum permitted average limits specified above by
more than 20 dB under any condition of modulation.

7.5.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C        Humidity: 51 % RH             Atmospheric Pressure: 1010     mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.5.2 Test Setup Diagram


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                   Report No.: SZEM190601543301
                                                                   Page:       23 of 26

7.5.3 Measurement Procedure and Data
      a. The EUT was placed on the top of a rotating table 0.8 meters above the ground for below 1GHz at
      a 3 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of
      the highest radiation.
      b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on
      the top of a variable-height antenna tower.
      c. The antenna height is varied from one meter to four meters above the ground to determine the
      maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set
      to make the measurement.
      d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was
      tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was
      tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find
      the maximum reading.
      e. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum
      Hold Mode.
      f. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing
      could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that
      did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method
      as specified and then reported in a data sheet.
      g. Test the EUT in the lowest channel,the middle channel,the Highest channel
      h. The radiation measurements are performed in X, Y, Z axis positioning for Transmitting mode,And
      found the X axis positioning which it is worse case.
      i. Repeat above procedures until all frequencies measured was complete.
      Remark: Level= Read Level+ Cable Loss+ Antenna Factor- Preamp Factor


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                     Report No.: SZEM190601543301
                                                     Page:       24 of 26

Mode:a; Polarization:Horizontal;


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                       Report No.: SZEM190601543301
                                                       Page:       25 of 26

Mode:a; Polarization:Vertical;


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                Report No.: SZEM190601543301
                                                                Page:       26 of 26



8   Photographs
8.1 Test Setup
    Refer to Setup Photos


8.2 EUT Constructional Details (EUT Photos)
    Refer to EUT external and internal photos




                                        - End of the Report -



Document Created: 2019-07-12 08:23:31
Document Modified: 2019-07-12 08:23:31

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC