RF Exposure Info

FCC ID: 2AO23-2210

RF Exposure Info

Download: PDF
FCCID_4355527

                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch




                                                                    Report No.: SZEM190601543302
                                                                    Page:        1 of 11

COVER PAGE
                       Human Exposure Report
Application No.:           SZEM1906015433CR
Applicant:                 Chug, Inc.
                           7157 Shady Oak Road Eden Prairie, Washington, Minnesota, United States
Address of Applicant:
                           55344
Manufacturer:              HANK Electronics Co., Ltd.
                           Floor 2nd-7th, A8, Hongye Industry City, Lezhujiao, Zhoushi Road, Baoan
Address of Manufacturer:
                           District, Shenzhen, China 518101
Equipment Under Test (EUT):
EUT Name:                  Stand wireless charger
Model No.:                 QIC-30, QIC-30S, QIC-30E ♣
                           Please refer to section 2.1 this report which indicates which model was
♣
                           actually tested and which were electrically identical.
Trade mark:                Heyday
FCC ID:                    2AO23-2210
Standards:                 47 CFR PART 1, Subpart I, Section 1.1310
Date of Receipt:           2019-05-24
Date of Test:                  2019-05-24 to 2019-06-20
Date of Issue:                 2019-06-20
Test Result :                    Pass*

* In the configuration tested, the EUT complied with the standards specified above.




            Keny Xu
      EMC Laboratory Manager


                                               SGS-CSTC Standards Technical Services Co., Ltd.
                                               Shenzhen Branch
                                                                                                    Report No.: SZEM190601543302
                                                                                                    Page:       2 of 11


1         Contents
                                                                                                                                                           Page
1      CONTENTS ................................................................................................................................................2

2      GENERAL INFORMATION ........................................................................................................................3
    2.1    DETAILS OF E.U.T. ...................................................................................................................................3
    2.2    DESCRIPTION OF SUPPORT UNITS .............................................................................................................4
    2.3    TEST LOCATION ........................................................................................................................................5
    2.4    TEST FACILITY ..........................................................................................................................................5
    2.5    DEVIATION FROM STANDARDS ...................................................................................................................6
    2.6    ABNORMALITIES FROM STANDARD CONDITIONS..........................................................................................6
3      EQUIPMENTS USED DURING TEST ........................................................................................................7

4      TEST RESULTS .........................................................................................................................................8
    4.1 RF EXPOSURE TEST .................................................................................................................................8
       4.1.1 E.U.T. Operation ............................................................................................................................8
       4.1.2 Measurement Data.........................................................................................................................9
5      PHOTOGRAPHS- TEST PHOTOS ..........................................................................................................11


                                      SGS—CSTC Standards Technical Services Co., Ltd.
                                      Shenzhen Branch

                                                                                                                Report No.: SZEM190601543302
                                                                                                                Page:                     3 of 11




General Information
Details of E.U.1T.

Power supply:                            Model:HKAP1231Q
                                          Input: AC 100—240V 50/60Hz 0.5A Max
                                         Output: DC 5V/3.0A,9V/2A,12V/1 .5A
                                         Wireless Charger:
                                          Input: DC 5V/2A,9V/1.7A, 12V/1 .25A
                                         Output: 10W
Cable:                                   USB cable: 175¢m unshielded
Operation Frequency:                      126.282kHz to 128.686kHz
Modulation Type:                         Load Modulation
Antenna Type:                            Loop Antenna
Antenna Gain:                            OdBi
Remark:                                  Tests were conducted in all three load modes and the worst case (DC 9V,
                                          1.7A) is reported only.


 Declaration of EUT Family Grouping:

 Model No.: QIC—30, QIC—30S, QIC—30E

 Only the model QIC—30 was tested, since the electrical circuit design, layout, components used,
 internal wiring and functions were identical for the above models, with only difference on model No..




                      Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                      overleaf, available on request or accessible at http://www.sgs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                      subject to Terms and Conditions for Electronic Documents at http://www.sqs.com/en/Terms—and—Conditions/Terms—e—Document.aspx.
                      Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                      advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                      Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                      transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                      except in full, without prior written approval of the Company. Any unauthorized alteration, for$ery or falsification of the content or
                      appearance of this document is unlawful and offenders may be prosecuted to the fullest extent         the law. Unless otherwise stated the
                      results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                      Attention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86—755) 8307 1443,
                      or email: CN.Doccheck@sgs.com
                                 CN.Doccheck@sgs.com
                . Ltd. No.1 Workshop, M—10, Middle Section, Science & Technology Park, Shenzhen, China 518057   t (86—755) 26012053 f (86—755) 26710594   www.sgsgroup.com.cn
                       +5 ~X— NKRFHEKM—10G—SJB                                                  BB&M: 518057    t (86—755) 26012053 f (86—755) 26710594   sgs.china@sgs.com
                      I
                                                                                                                                   Member of the SGS Group (SGS SA)


                       SGS-CSTC Standards Technical Services Co., Ltd.
                       Shenzhen Branch
                                              Report No.: SZEM190601543302
                                              Page:       4 of 11




2.2 Description of Support Units
    Description             Manufacturer   Model No.          Serial No.
    Mobile Phone              SAMSUNG      SM-G9500         R28J9140LPB
      iPhone 8                     Apple    A1863          F4GVQ656JC6D


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                     Report No.: SZEM190601543302
                                                                     Page:       5 of 11




2.3 Test Location
     All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
    No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
    518057.
    Tel: +86 755 2601 2053          Fax: +86 755 2671 0594
     No tests were sub-contracted.

2.4 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                             Report No.: SZEM190601543302
                                             Page:       6 of 11




2.5 Deviation from Standards
    None.

2.6 Abnormalities from Standard Conditions
    None.


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                         Report No.: SZEM190601543302
                                                         Page:       7 of 11




3   Equipments Used during Test

                                                             Inventory   Cal. Due date
    Item    Test Equipment        Manufacturer   Model No.
                                                                No.       (yyyy-mm-dd)

           3m Semi-Anechoic
     1                            ETS-LINDGREN     N/A       SEL0017      2020-06-10
               Chamber

     2     Electric Field Meter     Schaffner     EMC20       EMC068      2020-03-21


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                   Report No.: SZEM190601543302
                                                                   Page:       8 of 11




4     Test Results
4.1 RF Exposure test
      Test Requirement:               47 CFR PART 1, Subpart I, Section 1.1310
      Measurement Distance:           15cm
      Limit:

    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                            (A) Limits for Occupational/Controlled Exposures
         0.3-3.0                614                       1.63               *(100)              6
          3.0-30               1842/f                    4.89/f             *(900/f2)            6
         30-300                 61.4                     0.163                   1.0             6
        300-1500                  /                         /                 f/300              6
      1500-100,000                /                         /                    5               6
                         (B) Limits for General Population/Uncontrolled Exposure
         0.3-1.34               614                       1.63               *(100)             30
         1.34-30                824/f                    2.19/f             *(180/f2)           30
         30-300                 27.5                     0.073                   0.2            30
        300-1500                  /                         /                f/1500             30
      1500-100,000                /                         /                    1.0            30
    F=frequency in MHz
    *=Plane-wave equivalent power density
    RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules.
    The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
    150kHz:614V/m,1.63A/m).
4.1.1 E.U.T. Operation

      Operating Environment:
      Temperature:     25.0 °C            Humidity:    51 % RH         Atmospheric Pressure: 1015 mbar

       EUT Operation:
      This device has been tested with mobile phone at zero charge, intermediate charge, and full charge.


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                            Report No.: SZEM190601543302
                                                            Page:       9 of 11




4.1.2   Measurement Data


        Output Voltage=DC 9V; The max output power =10W;Calculation of resistor value=1.1Ω
        Electric Field Emissions
           Operation      Test Distance   Test Position   Probe Measure      50% Limit
           frequency                                       Result (V/m)
                              (cm)                                             (V/m)
                                             Side 1            3.51             307
                                             Side 2            2.22             307
          127.492 kHz          15            Side 3            3.74             307
                                             Side 4            2.01             307
                                              Top              1.37             307


        Magnetic Field Emissions
           Operation      Test Distance   Test Position   Probe Measure      50% Limit
           frequency                                       Result (A/m)
                              (cm)                                             (A/m)
                                             Side 1           0.1333            0.815
                                             Side 2           0.0916            0.815
          127.492 kHz          15            Side 3           0.1504            0.815
                                             Side 4           0.0721            0.815
                                              Top             0.0543            0.815


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                    Report No.: SZEM190601543302
                                                    Page:       10 of 11



Mobile phone has been charge at zero charge, intermediate charge, and full charge.

Electric Field Emissions

 Operation       Test                     Probe Measure Result(V/m)
                              Test                                        50%Limit
 frequency     Distance
                             Position    zero    intermediate     full
                                        charge      charge      charge      (V/m)
                  (cm)
                              Side 1     3.81        3.61        3.43        307
                              Side 2     2.52        2.27        2.09        307
   127.492
                   15         Side 3     4.02        3.73        3.53        307
    kHz
                              Side 4     2.26        2.01        1.79        307
                               Top       1.65        1.37        1.18        307


Magnetic Field Emissions

 Operation       Test                     Probe Measure Result(A/m)
                              Test                                        50%Limit
 frequency     Distance
                             Position   zero     intermediate   full
                                        charge      charge      charge      (A/m)
                  (cm)
                              Side 1    0.1448      0.1297      0.1153      0.815
                              Side 2    0.1044      0.0933      0.0796      0.815
   127.492
                   15         Side 3    0.1622      0.151       0.1365      0.815
    kHz
                              Side 4    0.0811      0.067       0.0526      0.815
                               Top      0.0632      0.0473      0.0329      0.815


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                          Report No.: SZEM190601543302
                                                          Page:       11 of 11




5     Photographs- Test photos
5.1    Test setup photos




                                  - End of the Report -



Document Created: 2019-07-11 12:12:39
Document Modified: 2019-07-11 12:12:39

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC