RF Exposure Info

FCC ID: 2AO23-1010QFC

RF Exposure Info

Download: PDF
FCCID_4347596

                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch




                                                                     Report No.: SZEM190601474602
                                                                     Page:        1 of 10


1     COVER PAGE

                       Human Exposure Report
Application No.:               SZEM1906014746CR
Applicant:                     Chug, Inc.
                               7157 Shady Oak Road Eden Prairie, Washington, Minnesota, 55344, United
Address of Applicant:
                               States
Manufacturer:                  HANK Electronics Co., Ltd.
                               Floor 2nd-7th, A8, Hongye Industry City, Lezhujiao, Zhoushi Road, Baoan
Address of Manufacturer:
                               District, Shenzhen, China
Equipment Under Test (EUT):
EUT Name:                      Wireless Charging Pad
Model No.:                     QIC-31, QIC-31S, QIC-31E       ♣
♣                              Please refer to section 3.2 of this report which indicates which model was
                               actually tested and which were electrically identical.
Trade Mark:                    Heyday
FCC ID:                        2AO23-1010QFC
Standards:                     47 CFR PART 1, Subpart I, Section 1.1310
Date of Receipt:               2019-06-04
Date of Test:                  2019-06-06 to 2019-06-13
Date of Issue:                 2019-06-17
Test Result :                    Pass*
* In the configuration tested, the EUT complied with the standards specified above




           Keny Xu
     EMC Laboratory Manager


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                           Report No.: SZEM190601474602
                                                           Page:       2 of 10




                                        Revision Record
     Version       Chapter               Date                 Modifier       Remark

     01                              2019-06-17                              Original




Authorized for issue by:




                             Bill Chen /Project Engineer




                             Eric Fu /Reviewer


                                               SGS-CSTC Standards Technical Services Co., Ltd.
                                               Shenzhen Branch
                                                                                                    Report No.: SZEM190601474602
                                                                                                    Page:       3 of 10




2         Contents
1      COVER PAGE ............................................................................................................................................1

1      COVER PAGE ............................................................................................................................................1

2      CONTENTS ................................................................................................................................................3

3      GENERAL INFORMATION ........................................................................................................................4
    3.1    DETAILS OF E.U.T. ...................................................................................................................................4
    3.2    DESCRIPTION OF SUPPORT UNITS .............................................................................................................4
    3.3    TEST LOCATION ........................................................................................................................................5
    3.4    TEST FACILITY ..........................................................................................................................................5
    3.5    DEVIATION FROM STANDARDS ...................................................................................................................5
    3.6    ABNORMALITIES FROM STANDARD CONDITIONS..........................................................................................5
4      EQUIPMENTS USED DURING TEST ........................................................................................................6

5      TEST RESULTS .........................................................................................................................................7
    5.1 RF EXPOSURE TEST .................................................................................................................................7
       5.1.1 E.U.T. Operation ............................................................................................................................7
       5.1.2 Measurement Data.........................................................................................................................8
6      PHOTOGRAPHS ......................................................................................................................................10
    6.1    TEST SETUP PHOTOS ..............................................................................................................................10


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                   Report No.: SZEM190601474602
                                                                   Page:       4 of 10




3     General Information
3.1     Details of E.U.T.
      Power supply:              Adapter:

                                 Model:HKAP1231Q
                                 Input: AC 100-240V 50/60Hz 0.5A Max
                                 Output: DC 5V/3A,9V/2A,15V/1.5A
                                 Wireless Charger:

                                 Input: DC 5V/2A,9V/1.7A, 12V/1.25A
                                 Output:10W
      Cable:                     USB cable:176cm unshielded
      Operation Frequency:       115.064kHz to 145.994kHz
      Modulation Type:           Load Modulation
      Antenna Type:              Loop Antenna
      Antenna Gain:              0dBi



3.2    Description of Support Units

      Description                  Manufacturer                 Model No.                  Serial No.
      Mobile Phone                  SAMSUNG                     SM-G9500                 R28J9140LPB
         iPhone 8                       Apple                     A1863                 F4GVQ656JC6D




      Remark:

      Model No.: QIC-31, QIC-31S, QIC-31E

      Only the model QIC-31 was tested, since the electrical circuit design, layout, components used, internal
      wiring and functions were identical for the above models, with only difference on model name.


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                  Report No.: SZEM190601474602
                                                                  Page:       5 of 10




3.3    Test Location
      All tests were performed at:
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab,
      No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China
      518057.
      Tel: +86 755 2601 2053         Fax: +86 755 2671 0594
      No tests were sub-contracted.

3.4    Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      • CNAS (No. CNAS L2929)
      CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
      Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
      Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
      Laboratories) for the competence in the field of testing.
      • A2LA (Certificate No. 3816.01)
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
      American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
      • VCCI
      The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
      Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
      Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
      been registered in accordance with the Regulations for Voluntary Control Measures with Registration
      No.: G-20026, R-14188, C-12383 and T-11153 respectively.
      • FCC –Designation Number: CN1178
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
      as an accredited testing laboratory.
      Designation Number: CN1178. Test Firm Registration Number: 406779.
      • Innovation, Science and Economic Development Canada
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
      by ISED as an accredited testing laboratory.
      CAB identifier: CN0006.
      IC#: 4620C.

3.5    Deviation from Standards
      None.

3.6    Abnormalities from Standard Conditions
      None.


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                         Report No.: SZEM190601474602
                                                         Page:       6 of 10




4   Equipments Used during Test

    Item     Test Equipment        Manufacturer   Model No.   Inventory No. Cal. Due date

           Electric and Magnetic
     1                                Narda       EHP-50F       EMC092        2020-02-06
              Field Analyzer


                                  SGS-CSTC Standards Technical Services Co., Ltd.
                                  Shenzhen Branch
                                                                      Report No.: SZEM190601474602
                                                                      Page:       7 of 10




5       Test Results
5.1       RF Exposure test
        Test Requirement:               47 CFR PART 1, Subpart I, Section 1.1310
        Measurement Distance:           15cm
        Limit:

    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                              (A) Limits for Occupational/Controlled Exposures
           0.3-3.0                 614                      1.63                *(100)             6
           3.0-30                1842/f                    4.89/f              *(900/f2)           6
           30-300                 61.4                     0.163                   1.0             6
          300-1500                  /                         /                  f/300             6
        1500-100,000                /                         /                    5               6
                          (B) Limits for General Population/Uncontrolled Exposure
          0.3-1.34                 614                      1.63                *(100)             30
           1.34-30                824/f                    2.19/f              *(180/f2)           30
           30-300                 27.5                     0.073                   0.2             30
          300-1500                  /                         /                 f/1500             30
        1500-100,000                /                         /                    1.0             30
    F=frequency in MHz
    *=Plane-wave equivalent power density
    RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules.
    The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
    150kHz:614V/m,1.63A/m).
5.1.1     E.U.T. Operation

        Operating Environment:
        Temperature:      24.5 °C           Humidity:    52 % RH         Atmospheric Pressure: 1015 mbar

        EUT Operation:
        This device has been tested the worst status of full load and the device has been tested with mobile
         phone at zero charge, intermediate charge, and full charge.


                                               SGS—CSTC Standards Technical Services Co., Ltd.
                                               Shenzhen Branch

                                                                                                                     Report No.: SZEM190601474602
                                                                                                                     Page:       8 of 10




5.1.2     Measurement Data


          Output Voltage=DC 12V; The max output power 18W;Calculation of resistor value=1.50
          Electric Field Emissions
              Operation              Test Distance                     Test Position                          Probe Measure                            50% Limit
              frequency                   (om)                                                                 Result (V/m)                              (V/im)

                                                                                Side 1                                    2.05                                 307

                                                                                Side 2                                    4.17                                 307
               136 kHz                            15                            Side 3                                    5.01                                 307
                                                                                Side 4                                    2.74                                 307
                                                                                  Top                                     3.86                                 307

          Magnetic Field Emissions

              Operation              Test Distance                     Test Position                          Probe Measure                            50% Limit
              frequency                        (om)                                                                 Result (A/m)                           (A/m)

                                                                                Side 1                                  0.2693                                 0.815
                                                                                Side 2                                  0.4534                                 0.815
               136 kHz                            15                            Side 3                                  0.5238                                 0.815
                                                                                Side 4                                  0.3124                                 0.815

                                                                                  Top                                   0.4116                                 0.815




                                Unless otherwise agreed in wriing, this document is issued by the Company subject to its General Conditions of Service printed
                                overleat, available on request or accessible at hitp://www.sg5.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                                subject to Terms and Conditions for Electronic Documents at hitpJwww.sgs.comfen/Terms—and—Conditions/Terms—6—Document.aspx.
                                Attention is drawn to the limitation of liabinty, indemnification andjurtsdiotion fesuge detined therein, Any holder of this document is
                                advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                Cllent‘s instructions, if any. The Company‘s sole responsibility is to its Client and this documentdoes not exonerate parties to a
                                transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the contant or
                                appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
                                results shown in this test report refer only to the sample(s)tested and such sample(s) are retained for 30 days only.
                                Aitention: To check the athenticlty of testing Inspection report & certificate. please contact us at felephone: (86—755) 8307 1443
                                or email: CN.Doccheck@sas.com
                      46 Co. id No.t Workshop,N—10, Mddle Section, Scence 8Technology Par, Shenchen, Clina 518057    t (B6—786) 26012058 1 (B6—786)26710504     wnimsgegroup.com.en
 Sterwhen B       Clatorioy     #B «20— RRBESHEM—108—S1                                             AB4: steo5r      t (B6—755) 26012058 1 (B6—785) 28710504     sgs.china@sgs.com
                                1
                                                                                                                                        Member of the SGS Group (SGS SA)


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                    Report No.: SZEM190601474602
                                                    Page:       9 of 10



Mobile phone has been charge at zero charge, intermediate charge, and full charge.

Electric Field Emissions

 Operation       Test                     Probe Measure Result(V/m)
                              Test                                        50%Limit
 frequency     Distance
                             Position    zero    intermediate     full
                                        charge      charge      charge      (V/m)
                  (cm)
                              Side 1     2.37        2.17        1.97        307
                              Side 2     4.44        4.21        3.98        307
  136 kHz          15         Side 3     5.35        5.13        4.89        307
                              Side 4     3.01        2.74        2.49        307
                               Top       4.16        3.95        3.72        307


Magnetic Field Emissions

 Operation       Test                     Probe Measure Result(A/m)
                              Test                                        50%Limit
 frequency     Distance
                             Position   zero     intermediate   full
                                        charge      charge      charge      (A/m)
                  (cm)
                              Side 1    0.2822      0.2687      0.2553      0.815
                              Side 2    0.4661      0.4548      0.4424      0.815
  136 kHz          15         Side 3    0.5326      0.5202      0.5067      0.815
                              Side 4    0.3231      0.3097      0.2969      0.815
                               Top      0.4239      0.4085      0.3941      0.815


                          SGS-CSTC Standards Technical Services Co., Ltd.
                          Shenzhen Branch
                                                         Report No.: SZEM190601474602
                                                         Page:       10 of 10




6     Photographs
6.1   Test setup photos




                                 - End of the Report -



Document Created: 2019-07-03 09:17:00
Document Modified: 2019-07-03 09:17:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC