MPE

FCC ID: 2ANRXUPAIR2

RF Exposure Info

Download: PDF
FCCID_3592645

                                Shenzhen BCTC Technology Co., Ltd.
                    FCC §15.247 (i), §2.1091 – RF Exposure

                  FCC ID: 2ANRXUPAIR2
Applied procedures / limit
According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this
section shall be operated in a manner that ensures that the public is not exposed to radio
frequency energy level in excess of the Commission’s guidelines.

                        Limits for Occupational / Controlled Exposure
                    Electric Field     Magnetic Field                        Averaging Time
  Frequency                                              Power Density (S)
                     Strength (E)       Strength (H)                           |E|2,|H|2or S
 Range (MHz)                                                 (mW/ cm2)
                         (V/m)              (A/m)                               (minutes)
    0.3-3.0               614                1.63               (100)*               6
     3.0-30             1842 / f            4.89 / f          (900 / f)*             6
    30-300                61.4              0.163                 1.0                6
   300-1500                                                     F/300                6
 1500-100,000                                                      5                 6
Note: ƒ is frequency in MHz
     * = Power density limit is applicable at frequencies greater than 100 MHz
                  Limits for General Population / Uncontrolled Exposure

                     Electric Field   Magnetic Field                   Averaging Time
   Frequency                                         Power Density (S)
                     Strength (E)      Strength (H)               2     |E|2,|H|2 or S
  Range (MHz)                                           (mW/ cm )
                         (V/m)            (A/m)                          (minutes)
     0.3-1.34             614              1.63           (100)*              30
     1.34-30             824/f            2.19/f         (180/f)*             30
     30-300               27.5            0.073             0.2               30
    300-1500                                              F/1500              30
  1500-100,000                                              1.0               30


Note: f = frequency in MHz
       * = Plane-wave equivalent power density


                                      Shenzhen BCTC Technology Co., Ltd.

MPE PREDICTION

      Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01


Where: S = power density
       P = power input to antenna
       G = power gain of the antenna in the direction of interest relative to an isotropic radiator
       R = distance to the center of radiation of the antenna, R=0.2m

TEST RESULTS


                                                                Total Power Density     Limit of
                   tune up power     max. output     Antenna            (S)             Power
                  tolerance (dBm)    power(mW)        Gain                                          Result
                                                                    (mW/ cm2)         Density (S)
                                                    (numeric)
                                                                                      (mW/ cm2)
                  ANT1     ANT2     ANT1    ANT2                 ANT1       ANT2

                                                       2.0
        802.11a   17±1     17±1     63.10   63.10               0.02505    0.02505        1         Pass
                                                    (3.0dBi)


        802.11n                                       3.98
                  15±1     15±1     39.81   39.81                    0.06306              1         Pass
          20                                        (6.0dBi)


        802.11n                                       3.98
                  14±1     14±1     31.62   31.62                     0.0501              1         Pass
          40                                        (6.0dBi)



Document Created: 2019-09-25 14:10:56
Document Modified: 2019-09-25 14:10:56

© 2024 FCC.report