Test Report

FCC ID: 2ANR7-TPMS4

Test Report

Download: PDF
FCCID_3879693

                             FCC Test Report
            FCC ID                 : 2ANR7-TPMS4
            Equipment              : Tire-pressure monitoring system (TPMS)
            Model No.              : TPMS4 ; SUN TPMX
                                      (Two models are for marketing purpose)
            Brand Name             : Snap-on
            Applicant              : ATEQ INSTRUMENTS (ASIA) PTE LTD.TAIWAN
                                     BRANCH (SINGAPORE)
            Address                : 3 LANE223, SAN JIA DONG STREET, 40642,
                                     TAICHUNG
            Standard               : 47 CFR FCC Part 15.209
            Received Date          : Oct. 30, 2017
            Tested Date            : Apr. 10 ~ Apr. 16, 2018


      We, International Certification Corp., would like to declare that the tested sample has been
      evaluated and in compliance with the requirement of the above standards. The test results
      contained in this report refer exclusively to the product. It may be duplicated completely for
      legal use with the approval of the applicant. It shall not be reproduced except in full without
      the written approval of our laboratory.



      Reviewed by:                        Approved by:




      Along Chen / Assistant Manager      Gary Chang / Manager




Report No.: FR7O3001                                                                  Page : 1 of 21
Report Version: Rev. 01


                                                         Table of Contents
1        GENERAL DESCRIPTION .................................................................................................................... 5

1.1      Information.............................................................................................................................................. 5
1.2      Test Setup Chart .................................................................................................................................... 6
1.3      The Equipment List ................................................................................................................................ 7
1.4      Test Standards ....................................................................................................................................... 7
1.5      Measurement Uncertainty ...................................................................................................................... 7

2        TEST CONFIGURATION ....................................................................................................................... 8

2.1      Testing Condition ................................................................................................................................... 8
2.2      The Worst Test Modes and Channel Details ......................................................................................... 8

3        TRANSMITTER TEST RESULTS.......................................................................................................... 9

3.1      Conducted Emissions ............................................................................................................................. 9
3.2      Radiated Emissions ..............................................................................................................................12

4        TEST LABORATORY INFORMATION ...............................................................................................21




Report No.: FR7O3001                                                                                                                Page : 2 of 21
Report Version: Rev. 01


                                    Release Record
     Report No.           Version                   Description      Issued Date
     FR7O3001             Rev. 01   Initial issue                    May 11, 2018




Report No.: FR7O3001                                              Page : 3 of 21
Report Version: Rev. 01


                                  Summary of Test Results
   FCC Rules                      Test Items                Measured                  Result
                                                 [dBuV/m at 3m]: 0.168MHz
      15.207         Conducted Emissions                                               Pass
                                                 54.56 (Margin -10.52dB) - QP
                                                 [dBuV/m at 3m]: 117.30MHz
      15.209         Radiated Emissions                                                Pass
                                                 42.45 (Margin -1.05dB) - QP




Report No.: FR7O3001                                                      Page : 4 of 21
Report Version: Rev. 01


1           General Description
1.1         Information
1.1.1       Specification of the Equipment under Test (EUT)
                                               RF General Information
 Frequency Range                                    Ch. Frequency
                                 Modulation                                Channel Number        Data Rate
      (kHz)                                              (kHz)
        123 ~ 127                   CW                      125                     1             10 kbps


1.1.2       Antenna Details
 Ant. No.                 Type                  Gain (dBi)               Connector              Remark
        1            Wirebound                        ---                     ---                   ---


1.1.3       EUT Operational Condition
                                  5Vdc from AC adapter
Supply Voltage
                                  3.8Vdc from Lithium battery


1.1.4       Accessories
 No.             Equipment              Description
                                        Brand: NEXcell Battery Co., Ltd.
    1               Battery             Model Name: NLI-N7100.
                                        Power Rating: 3.8Vdc, 3050mAh
                                        Brand: JS
                                        Model: FJ-SW1260502000UN
    2               Adapter
                                        I/P: 100-240Vac, 50/60Hz, 0.4A
                                        O/P: 5Vdc, 2000mA
    3            USB cable              1.1m shielded with 2 cores
    4         Tire Tread Depth          1.76m shielded with 1 core




Report No.: FR7O3001                                                                        Page : 5 of 21
Report Version: Rev. 01


                                       Support Equipment List
 No.     Equipment        Brand       Model         S/N         FCC ID    Signal cable / Length (m)
         Tire Tread                                                      RJ45, 1.76m shielded with 1
   1                       ---          ---         ---            ---
        Depth (TTD)                                                      core.


1.2       Test Setup Chart
                                  Test Setup Diagram (Charger mode)




                                    Test Setup Diagram (TX mode)




Report No.: FR7O3001                                                             Page : 6 of 21
Report Version: Rev. 01


1.3       The Equipment List
      Test Item        Radiated Emission
      Test Site        966 chamber1 / (03CH01-WS)
      Instrument           Manufacturer             Model No.           Serial No.   Calibration Date       Calibration Until
 Spectrum Analyzer             R&S                    FSV40              101498       Dec. 04, 2017          Dec. 03, 2018
       Receiver                R&S                    ESR3               101658       Nov. 20, 2017          Nov. 19, 2018
    Bilog Antenna         SCHWARZBECK               VULB9168          VULB9168-522     Jul. 25, 2017          Jul. 24, 2018
    Loop Antenna               R&S                   HFH2-Z2             100330       Nov. 13, 2017          Nov. 12, 2018
 Loop Antenna Cable        KOAX KABEL              101354-BW           101354-BW      Dec. 07, 2017          Dec. 06, 2018
     Preamplifier              EMC                 EMC02325              980225        Jul. 28, 2017          Jul. 27, 2018
      RF Cable            HUBER+SUHNER           SUCOFLEX104           MY16014/4      Dec. 07, 2017          Dec. 06, 2018
      RF Cable            HUBER+SUHNER           SUCOFLEX104           MY16019/4      Dec. 07, 2017          Dec. 06, 2018
      RF Cable            HUBER+SUHNER           SUCOFLEX104           MY16139/4      Dec. 07, 2017          Dec. 06, 2018
                                               EMCCFD400-NM-N
     LF cable 1M               EMC                                        16052       Dec. 07, 2017          Dec. 06, 2018
                                                   M-1000
     LF cable 3M              Woken              CFD400NL-LW          CFD400NL-001    Dec. 07, 2017          Dec. 06, 2018
    LF cable 10M              Woken              CFD400NL-LW          CFD400NL-002    Dec. 07, 2017          Dec. 06, 2018
    Measurement
                              AUDIX                     e3             6.120210g           NA                      NA
     Software
Note: Calibration Interval of instruments listed above is one year.



1.4       Test Standards
According to the specification of EUT, the EUT must comply with following standards and KDB documents.
47 CFR FCC Part 15.209
ANSI C63.10-2013
FCC KDB 414788 D01 Radiated Test Site v01


1.5       Measurement Uncertainty
ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions test
results be included in the report. The measurement uncertainties given below are based on a 95% confidence
level (based on a coverage factor (k=2)

                                                   Measurement Uncertainty
                                              Parameters                                                 Uncertainty
AC conducted emission                                                                                      ±2.90 dB
Radiated emission                                                                                          ±3.66 dB




Report No.: FR7O3001                                                                                   Page : 7 of 21
Report Version: Rev. 01


2         Test Configuration
2.1       Testing Condition
          Test Item                Test Site           Ambient Condition              Tested By
AC Conduction                     CO01-WS                  22°C / 59%                  Alex Tsai
Radiated Emissions               03CH01-WS                 24°C / 61%                Akun Chung
 FCC Designation No.:     TW2732
 FCC site registration No.:   181692
 IC site registration No.: 10807A-1


2.2       The Worst Test Modes and Channel Details
          Test item            Modulation Mode        Test Frequency (kHz)        Test Configuration
AC Conducted Emissions                  ---                     ---                 Charger mode
                                        ---                     ---                 Charger mode
Radiated Emissions
                                        CW                      125                    TX mode
NOTE:
The EUT was pretested with 3 orientations placed on the table for the radiated emission measurement – X,
Y, and Z-plane. The X-plane results were found as the worst case and were shown in this report




Report No.: FR7O3001                                                                 Page : 8 of 21
Report Version: Rev. 01


3         Transmitter Test Results
3.1       Conducted Emissions
3.1.1     Limit of Conducted Emissions
                                        Conducted Emissions Limit
     Frequency Emission (MHz)                   Quasi-Peak                            Average
                0.15-0.5                          66 - 56 *                            56 - 46 *
                  0.5-5                              56                                   46
                   5-30                              60                                   50
Note 1: * Decreases with the logarithm of the frequency.


3.1.2     Test Procedures
1.    The device is placed on a test table, raised 80 cm above the reference ground plane. The vertical
      conducting plane is located 40 cm to the rear of the device.
2.    The device is connected to line impedance stabilization network (LISN) and other accessories are
      connected to other LISN. Measured levels of AC power line conducted emission are across the 50 Ω
      LISN port.
3.    AC conducted emission measurements is made over frequency range from 150 kHz to 30 MHz.
4.    This measurement was performed with AC 120V / 60Hz.


3.1.3     Test Setup




Report No.: FR7O3001                                                                    Page : 9 of 21
Report Version: Rev. 01


Charger mode
3.1.4     Test Result of Conducted Emissions
Power Phase               Line                      Test Freq. (kHz)             125




Note 1: Level (dBuV) = Read Level (dBuV) + LISN Factor (dB) + Cable Loss (dB).
     2: Over Limit (dB) = Level (dBuV) – Limit Line (dBuV).




Report No.: FR7O3001                                                                   Page : 10 of 21
Report Version: Rev. 01


Power Phase               Neutral                   Test Freq. (kHz)             125




Note 1: Level (dBuV) = Read Level (dBuV) + LISN Factor (dB) + Cable Loss (dB).
     2: Over Limit (dB) = Level (dBuV) – Limit Line (dBuV).




Report No.: FR7O3001                                                                   Page : 11 of 21
Report Version: Rev. 01


C           Infernational
            Certification
            Corp.




3.2          Radiated Emissions

3.2.1       Limit of Radiated Emissions

                                             Restricted Band Emissions Limit
Frequency Range (MHz)|            Field Strength (uV/m)        |Field Strength (dBuV/m)|        Measure Distance (m)
         0.009~0.490                    2400/F(kHz)                    48.5 — 13.8                         300
         0.490~1.705                   24000/F(kHz)                     33.8 — 23                          30
          1.705~30.0                           30                         29.54                            30
             30~88                            100                           40                              3
            88~216                            150                          43.5                             3
            216~960                           200                           46                              3
          Above 960                           500                           54                              3
Note 1:
Qusai—Peak value is measured for frequency below 1GHz except for 9—90 kHz, 110—490 kHz frequency band. Peak and
average value are measured for frequency above 1GHz. The limit on average radio frequency emission is as above table.
The limit on peak radio frequency emissions is 20 dB above the maximum permitted average emission limit
Note 2:
Measurements may be performed at a distance other than what is specified provided. When performing measurements at
a distance other than that specified, the results shall be extrapolated to the specified distance using an extrapolation
factor as below, Frequency at or above 30 MHz: 20 dB/decade Frequency below 30 MHz: 40 dB/decade.



3.2.2      Test Procedures
1.      Measurement is made at a semi—anechoic chamber that incorporates a turntable allowing a EUT
        rotation of 360°. A continuously—rotating, remotely—controlled turntable is installed at the test site to
        support the EUT and facilitate determination of the direction of maximum radiation for each EUT
        emission frequency. The EUT is placed at a height of 0.8 m test table above the ground plane.
2.      Measurement is made with the antenna positioned in both the horizontal and vertical planes of
        polarization. The measurement antenna is varied in height (1m ~4m) above the reference ground plane
      to obtain the maximum signal strength. Distance between EUT and antenna is 3 m.
3.      This investigation is performed with the EUT rotated 360°, the antenna height scanned between 1 m
        and 4 m, and the antenna rotated to repeat the measurements for both the horizontal and vertical
        antenna polarizations.
Note:
1.      120kHz measurement bandwidth of test receiver and Quasi—peak detector is for radiated emission below 1GHz.

2.      Correction values between measurement form the semi—anechoic chamber and open—field test site have been
        confirmed and added to the factor.




Report No.: FR703001                                                                                 Page : 12 of 21
Report Version: Rev. 01


3.2.3     Test Setup
Radiated Emissions below 30MHz




Radiated Emissions below 1 GHz




Report No.: FR7O3001             Page : 13 of 21
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




TX mode
3.2.4       Transmitter Radiated Unwanted Emissions (9kHz ~ 1.705MHz)
 Polarization              Loop Open
                           Emission          imi            .       SA
  Frequency (MHz)            Level      dII;m\‘II/t   Me:lrgln    Reading    Factor        Remark
                            dBuv/im     (dBuV/m)       (dB)       (dBuV/m)
    1          0.125         77.17       105.67       —28.50       54.20     22.97         Average
    2          0.125         77.25       125.67       —48.42       54.20     22.97           Peak
    3          0.250         60.90       99.65        —38.75       37.50     22.59         Average
    4          0.250         61.49       119.65       —58.16       38.90     22.59           Peak
    5          0.375         57.70       96.12        —38.42       35.40     22.30         Average
    6          0.375         58.40       116.12       —57.72       36.10     22.30           Peak


 Polarization              Loop Close
                           Emission         imi            .        SA
  Frequency (MHz)            Level      dlém\‘lllt    M(ng)m      Reading    Factor        Remark
                            dBuv/im     (dBuV/m)                  (dBuV/m)
    1          0.125         72.27       105.67       —33.40       49.30     22.97         Average
    2          0.125         72.35       125.67       —53.32       49.30     22.97           Peak
    3          0.250         55.19       99.65        —44.46       32.60     22.59         Average
    4          0.250         56.29       119.65       —63.36       33.70     22.59           Peak
    5          0.375         55.10       96.12        —41.02       32.80     22.30         Average
    6          0.375         56.40       116.12       —59.72       34.10     22.30           Peak
Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor® (dB).
       *Factor includes antenna factor and cable loss.
Note 2: Margin (dB) = Emission level (dBuV/m) — Limit (dBuV/m).




Report No.: FR703001                                                             Page : 14 of 21
Report Version: Rev. 01


TX mode
3.2.5     Transmitter Radiated Unwanted Emissions (Below 30MHz)
Polarization              Loop Open                Test Freq. (kHz)   125




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor (dB)
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m)




Report No.: FR7O3001                                                        Page : 15 of 21
Report Version: Rev. 01


Polarization              Loop Close               Test Freq. (kHz)   125




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor (dB)
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m)




Report No.: FR7O3001                                                        Page : 16 of 21
Report Version: Rev. 01


TX mode
3.2.6     Transmitter Radiated Unwanted Emissions (Above 30MHz)
Polarization              Horizontal                Test Freq. (kHz)    125




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m)




Report No.: FR7O3001                                                          Page : 17 of 21
Report Version: Rev. 01


Polarization              Vertical                  Test Freq. (kHz)    125




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m)




Report No.: FR7O3001                                                          Page : 18 of 21
Report Version: Rev. 01


Charger mode
3.2.7     Transmitter Radiated Unwanted Emissions (Above 30MHz)
Polarization              Horizontal                Test Freq. (kHz)    125




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m)




Report No.: FR7O3001                                                          Page : 19 of 21
Report Version: Rev. 01


Polarization              Vertical                  Test Freq. (kHz)    125




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m)




Report No.: FR7O3001                                                          Page : 20 of 21
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




4          Test laboratory information
Established in 2012, ICC provides foremost EMC & RF Testing and advisory consultation services by our
skilled engineers and technicians. Our services employ a wide variety of advanced edge test equipment and
one of the widest certification extents in the business.


International Certification Corp (EMC and Wireless Communication Laboratory), it is our definitive objective is
to institute long term, trust—based associations with our clients. The expectation we set up with our clients is
based on outstanding service, practical expertise and devotion to a certified value structure. Our passion is to
grant our clients with best EMC / RF services by oriented knowledgeable and accommodating staff.


Our Test sites are located at Linkou District and Kwei Shan District. Location map can be found on our
website http://www.icertifi.com.tw.


Linkou                                 Kwei Shan                            Kwei Shan Site II
Tel: 886—2—2601—1640                   Tel: 886—3—271—8666                  Tel: 886—3—271—8640
No. 30—2, Ding Fwu Tsuen, Lin          No. 3—1, Lane 6, Wen San 3rd St.,    No. 14—1, Lane 19, Wen San 3rd
Kou District, New Taipei City,         Kwei Shan District, Tao Yuan City    St., Kwei Shan District, Tao Yuan
Taiwan, R.0.C.                         333, Taiwan, R.O.C.                  City 333, Taiwan, R.O.C.

If you have any suggestion, please feel free to contact us as below information.

Tel: 886—3—271—8666
Fax: 886—3—318—0155
Email: ICC_Service@icertifi.com.tw




==END=




Report No.: FR703001                                                                       Page : 21 of 21
Report Version: Rev. 01



Document Created: 2018-05-11 10:54:44
Document Modified: 2018-05-11 10:54:44

© 2024 FCC.report