RF Exposure

FCC ID: 2ANP7PPBK2

RF Exposure Info

Download: PDF
FCCID_4473626

I#]
       TEST                                                                                      Model: PRBK2




                 Measurement and Test Report
                                               For

                              Eggtronic Engineering Srl

                 Via Giorgio Campagna 8 41126 Modena (MO) Italy


                                FCC ID: 2ANP7PPBK2


 FCC Rule(s):                       KDB 680106 DO1 VO3

 Product Description:              Wireless Power Bank

 Tested Model:                      PRBK2

 Report No.:                       WTX19X09062900W—2

 Tested Date:                      2019—09—09

 Issued Date:                      2019—09—09 to 2019—09—16

 Tested By:                        2019—09—16                         Make Shi
                                                                      (~. I..f 1   -"‘.-"r   _


 Reviewed By:                       Silin Chen / EMC Manager          VNtw SSEA

 Approved & Authorized By:         Jandy So / PSQ Manager             j”"%fi?

 Prepared By:
                        Shenzhen SEM Test Technology Co., Ltd.
                      1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road,
                      Bao‘an District, Shenzhen, P.R.C. (518101)
          Tel.: +86—755—33663308   Fax.: +86—755—33663309     Website: www.semtest.com.cn




   Note: This test report is limited to the above client company and the product model only. It
   may not be duplicated without prior permitted by Shenzhen SEM Test Technology Co., Ltd.




REPORT NO.: WTX19X09062900W—2                   PAGE 1 OF 8                                       RF Exposure


                                                                                                                                                         Model: PRBK2


TABLE OF CONTENTS
1. GENERAL INFORMATION ...................................................................................................................................4
   1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...............................................................................4
2. RF EXPOSURE TEST REPORT ............................................................................................................................5
   2.1 STANDARD APPLICABLE.........................................................................................................................................5
   2.2 TEST CONDITIONS ..................................................................................................................................................5
   2.3 TEST PROCEDURE ...................................................................................................................................................6
   2.4 TEST RESULT..........................................................................................................................................................6
   2.4 TEST PHOTOS .........................................................................................................................................................8




REPORT NO.: WTX19X09062900W-2                                                        PAGE 2 OF 8                                                           RF Exposure


                                                                Model: PRBK2


Report version
  Version No.       Date of issue                 Description

    Rev.00           2019-09-16                    Original

       /                  /                            /




REPORT NO.: WTX19X09062900W-2       PAGE 3 OF 8                 RF Exposure


                                                                                                    Model: PRBK2


1. GENERAL INFORMATION

1.1 Product Description for Equipment Under Test (EUT)

  Client Information
  Applicant:                                     Eggtronic Engineering Srl
  Address of applicant:                          Via Giorgio Campagna 8 41126 Modena (MO) Italy

  Manufacturer:                                  Shenzhen Pilot Technology Co.,Ltd
  Address of manufacturer:                       A1 Building, No.7 Shankeng Road, Shankeng
                                                 Industrial Park, Shanxia Community, Pinghu Street,
                                                 Longgang District, Shenzhen, China.

  General Description of EUT
  Product Name:                                  Wireless Power Bank
  Trade Name:                                    EGGTRONIC
  Model No.:                                     PRBK2
  Adding Model(s):                               PRBL2,PRGR2,PPBK2,PPBL2,PPGR2
  Battery Capacity                               1500mAh


  Note: The test data is gathered from a production sample, provided by the manufacturer. The appearance of
  others models listed in the report is different from main-test model PRBK2, but the circuit and the electronic
  construction do not change, declared by the manufacturer.


  Technical Characteristics of EUT
  Frequency Range:                               110~205kHz
  Antenna Type:                                  Coil Antenna
  Rated Voltage:                                 DC5V (Wireless output)
  Rated Current:                                 ≤1A (Wireless output)
  Rated Power:                                   ≤ 5W (Wireless output)




REPORT NO.: WTX19X09062900W-2                          PAGE 4 OF 8                                   RF Exposure


I#]
            TEest                                                                                         Model: PRBK2



2. RF Exposure Test Report

2.1 Standard Applicable

According to § 1.1310 system operating under the provisions of this section shall be operating in a manner that
the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure.


                                    Taeue 1—Limits ror Maxmun Permwissioce Exeosure (MPE)


 Frequency range      |Electric field strength      Magnetic field strength         Power density     |Averaging time
 (MHz)                (Vim)                         (A/m)                           {mW!cmE}          (minutes)
                                   (A) Limits for Occupational/Controlled Exposure
 0.3—3.0                                        614                          1.63                *100                    6
 3.0—30                                      1842/7                        4. 89/Tf           *300/f2                    6
 30—300                                           61.4                        0.163            1.0                       6
 300—1,500                                                                                    300                        6
 1,500—100,000                                                                                   5                       6
                             (B) Limits for General Population/Uncontrolled Exposure
 0.3—1.34                                     614                       1.63                    *100                    30
 1.34—30                                     824/f                     2.19/f                *180/f2                    30
 30—300                                        27.5                           0.073            02                       30
 300—1,500                                                                                   1500                       30
 1,500—100,000                                                                                 1.0                      30

     f= frequency in MHz *= Plane—wave equivalent power density


2.2 Test Conditions

      Test Mode                     Description                   Remark                     Power Supply Mode
                                .              .                          .              DC 5V (with a adapter input
            TM1              Wireless charging                    Transmit
                                                                                                AC 120V/60H2z)


    Measurement
        .                                                            15 cm
      Distance:




REPORT NO.: WTX19X09062900W—2                              PAGE 5 OF 8                                     RF Exposure


                                                                                             Model: PRBK2



2.3 Test Procedure




a. The measurement probe was placed at test distance(15 cm for A,B,C,D,F and 20 cm for E) which is between
   the edge of the charger and the geometric center of probe.
b. The highest emission level was recorded at the measurement points(A, B, C, D, E, F).
c. The EUT was measured according to the distance of KDB 680106 D01 V03.

2.4 Test Result

The EUT dose comply with item 5.2 of KDB 680106 D01V03

1. Power transfer frequency is less that 1 MHz
     Yes, the device operate in the frequency range from 110kHz to 205kHz.


2. Output power from each primary coil is less than 15 watts
     Yes, the maximum output power of the primary coil is less than 15W.


3. The transfer system includes only single primary and secondary coils. This includes
     charging systems that may have multiple primary coils and clients that are able
     to detect and allow coupling only between individual pairs of coils
     Yes, the client device includes only single primary coils.


4. Client device is inserted in or placed directly in contact with the transmitter
     Yes, Client device is placed directly in contact with the transmitter.


5. Mobile exposure conditions only (portable exposure conditions are not covered by
     this exclusion).
     Yes, It is mobile exposure conditions only.


REPORT NO.: WTX19X09062900W-2                       PAGE 6 OF 8                                RF Exposure


                                                                               Model: PRBK2



6. The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above
   the top surface from all simultaneous transmitting coils are demonstrated to be
   less than 50% of the MPE limit.
   Yes, The EUT field strength levels are less than 50% of the MPE limit, refer to
   test TM1, TM2 list, and the coils can’t transmitted simultaneous.


Test Mode: TM1
                                  Electric Field Emissions
     Test Position         Measure Value (V/m)               Limit(V/m)   50% Limit (V/m)
         Top                      6.41                          614            307
        Bottom                    6.46                          614            307
        Side 1                    7.53                          614            307
        Side 2                    8.70                          614            307
        Side 3                    6.00                          614            307
        Side 4                    5.65                          614            307


                                 Magnetic Field Emissions
     Test Position         Measure Value (A/m)               Limit(A/m)   50% Limit (A/m)
         Top                      0.80                          1.63           0.815
        Bottom                    0.78                          1.63           0.815
        Side 1                    0.71                          1.63           0.815
        Side 2                    0.62                          1.63           0.815
        Side 3                    0.81                          1.63           0.815
        Side 4                    0.80                          1.63           0.815




REPORT NO.: WTX19X09062900W-2               PAGE 7 OF 8                         RF Exposure


                                                            Model: PRBK2



2.4 Test Photos




                                ***** END OF REPORT *****




REPORT NO.: WTX19X09062900W-2              PAGE 8 OF 8      RF Exposure



Document Created: 2019-10-09 10:11:11
Document Modified: 2019-10-09 10:11:11

© 2024 FCC.report