user manual

FCC ID: 2ANP7EGG170016

Users Manual

Download: PDF
FCCID_4439863

w w w.e g g t ro n i c .c o m   |   supportb2b@eggtronic.com




 Triple coil embedded wireless charging system


                                                                                                          F E AT U R E S

                                                                                 • Compatible with WPC Qi 1.2 wireless charging standard

                                                                                 • Designed for integration: a completely hidden solution

                                                                                 • Industrial adhesive mounting tape, no need for screws

                                                                                 • Quick and practical installation process, easy charger
                                                                                 removal without damaging the top

                                                                                 • Maximum power 5W

                                                                                 • Triple coil free positioning technology allows wider charging
                                                                                 area compared to standard solutions

                                                                                 • Designed to be installed under surfaces with maximum
                                                                                 thickness of 5 mm (0.19 in)




HOW TO USE
1. Remove the layer on the adhesive mounting tape

2. Apply under surface. Works with most non-metal surfaces

3. Connect the cable to the power source

4. Lay down any Qi-enabled smartphone on the wireless charging
area to start charging




GENERAL DESCRIPTION
The “Triple coil embedded wireless charging system” is a wireless charging module designed to be integrated in any surface.
Using the provided adhesive mounting tape, it can be installed under slim surfaces (maximum 5 mm thickness). No need for screws: the installation process is
quick and easy, and the charger can be removed without damaging the top. The “Triple coil embedded wireless charging system” embeds a Qi-compliant
chipset: it is compatible with the WPC Qi 1.2 wireless charging standard, and works with any Qi-compliant device. A triple-coil system ensures high positioning
freedom.




Copyright Eggtronic, All rights reserved


w w w.e g g t ro n i c .c o m   |   supportb2b@eggtronic.com




S P E C I F I C AT I O N S


  Physical Specifications
                                                               60 x 103 x 8.5 mm
  Dimensions
                                                               (2.36 x 4.05 x 0.39 in)

  Weight                                                       85 g (0.19 lbs)

  Cable length                                                 45 cm (1.5 ft)




  Electrical Specifications

  Input                                                        Min 11.4V Max 12.6V

  Input current                                                Max 1A

  Output                                                       wireless 5W

  Standby mode consumption                                     ~ 25 mA

  Storage temperature                                          -10°C / 70°C

  Operating temperature                                        0°C / 40°C

  Operating frequency                                          115 - 205 kHz




PIN OUTPUT
MOLEX 430250200




  PIN                                                          Signal

  1                                                            12V

  2                                                            GND




Copyright Eggtronic, All rights reserved


w w w.e g g t ro n i c .c o m   |   supportb2b@eggtronic.com




T EC H N I CA L D R AW I N G S




Copyright Eggtronic, All rights reserved


w w w.e g g t ro n i c .c o m   |   supportb2b@eggtronic.com




A P P E N D I X A – C L I M AT I C T E S T

1. CEI EN 60068-2-1: Cold

Test description
The sample stored at ambient temperature, is introduced into the climate chamber, whose temperature is the same of ambient
temperature (storing temperature: 25°C). Then the temperature lowers at -10°C and the sample is maintained at this
temperature for 16h. Humidity must be 0%.

Restoring the ambient temperature
The sample must be maintained at ambient temperature to allow defrosting (at least 1 hour)

Final measure
The sample must be inspected (visual and functional) and strength test must be executed.




  Test passed                                                         yes




                                                                                                               100
   150                                                                                                         %rh
   °C                                                                                                                temp
   100
   °C                                                                                                                hum
                                                                                                               50
   50                                                                                                          %rh
   °C
   0
   °C
                                                                                                               0
                                                                                                               %rh
                                     1h                                          16h




2. CEI EN 60068-2-2: Dry heat

Test description
The sample stored at ambient temperature, is introduced into the climate chamber, whose temperature is the same of ambient
temperature (storing temperature: 25°C). Then the temperature increases at 70°C and the sample is maintained at this
temperature for 16h. Humidity must be 0%.

Restoring the ambient temperature
The sample must be maintained at ambient temperature to allow restoring thermal stability (at least 1 hour).

Final measure
The sample must be inspected (visual and functional) and strength test must be executed.




  Test passed                                                         yes




Copyright Eggtronic, All rights reserved


w w w.e g g t ro n i c .c o m   |   supportb2b@eggtronic.com




                                                                                                                100
   150                                                                                                          %rh
   °C                                                                                                                 temp
   100
   °C                                                                                                                 hum
                                                                                                                50
   50                                                                                                           %rh
   °C
   0
   °C
                                                                                                                0
                                                                                                                %rh
                                     1h                                               16h




3. CEI EN 60068-2-14: Temperature change

Test description
The sample stored at ambient temperature, is introduced into the climate chamber, whose temperature is the same of ambient
temperature (storing temperature: 25°C). Then the temperature decreases at -10°C (with a variation velocity of 3±0.6°C/min)
and the sample is maintained at this temperature for 3h. Afterwards the temperature increases at 70°C (with a variation velocity
of 3±0.6°C/min) and the sample is maintained at this temperature for 3h. Hence bring back the temperature at 25°C, 10%rh
(with a variation velocity of 3±0.6°C/min).
This test must be executed two times without interruption (then 2 cycles) for a total execution time of 827min.

Restoring the ambient temperature
The sample must be maintained at ambient temperature to allow restoring thermal stability (at least 1 hour).

Final measure
The sample must be inspected (visual and functional) and strength test must be executed.




  Test passed                                                              YES with note 1




                                                                                                                100
   150                                                                                                          %rh
   °C                                                                                                                 temp
   100
   °C                                                                                                                 hum
                                                                                                                50
   50                                                                                                           %rh
   °C
   0
   °C
                                                                                                                0
                                                                                                                %rh
                  1h                      12’      12h               26’             12h          28’

                                                         2x cycles




Note 1: Climate chamber ESPEC SH-642 can’t follow the indication of 3±0.6°C/min for the first step, then the test was been
executed at 1.4°C/min (Step_1_time = 25’).




Copyright Eggtronic, All rights reserved


w w w.e g g t ro n i c .c o m    |   supportb2b@eggtronic.com




4. CEI EN 60068-2-30: Wet heat, cyclic (12h+12h)

Test description
The sample stored at ambient temperature, is introduced into the climate chamber, whose temperature is the same of ambient
temperature (storing temperature: 25°C). Then the temperature increases at 55°C (in a period not less than 3h) and the sample
is maintained at this temperature for 11h45’ at 93%rh and then for 15’ at 95%rh. Afterwards the temperature decreases at 25°C
(in a period between 3h and 6h). In the first 1h 30’ the decrease velocity must be sufficient to complete the temperature variation
in 3h and after this the sample must be maintained at this temperature (25°C) until 24h from the start of the test.

Restoring the ambient temperature
The sample must be maintained at ambient temperature to allow restoring thermal stability (at least 1 hour).

Final measure
The sample must be inspected (visual and functional) and strength test must be executed.




  Test passed                                                                                                        yes




                                                                                                                                                                  100
  150                                                                                                                                                             %rh
  °C                                                                                                                                                                    temp

  100
  °C                                                                                                                                                                    hum
                                                                                                                                                                  50
  50                                                                                                                                                              %rh
  °C
  0
  °C
                                                                                                                                                                  0
                                                                                                                                                                  %rh

                 1h                   3h                11h 45’                       15’                            3h                  6h                  1h
                                                                                                                                         test period = 24h
                                                  Final measure:
                                                         The sample must be inspected (visual and func�onal) and strength test must be executed.


                                                  assed:




APPENDIX B – CURRENT CONSUMPTION                  APPE NDIX B


The below screenshots are sampling for current consumption in different operating points:
- Stand by current with ping          APPE NDIX B – CUR R E NT CONS UMPTION
- Charging light load (only RX energized)
                                      The below s creens hots are s ampling for current cons umption in different operating
                                      points :
                                         ● S tand by current with ping
- Charging 5W load                       ● Charging light load (only R X energized)
                                                      ● Charging 5W load




                                                                                        Figura 1: WCP ping routine

                                                                                         1. WCP ping routine



Copyright Eggtronic, All rights reserved


w w w.e g g t ro n i c .c o m   |   supportb2b@eggtronic.com




                                                            Figura 2:Light load charging

                                                            3. Light load charging




                                                             Figura 2:Light load charging




                                                               Figura 3: 5W charging




                                                               Figura 3: 5W charging

                                                                3. 5W charging




FCC Warning

This device complies with part 18 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.

NOTE: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.



Copyright Eggtronic, All rights reserved