RF Exposure Report

FCC ID: 2ANOT-204531

RF Exposure Info

Download: PDF

                                   SGS-CSTC Standards Technical Services Co., Ltd.
                                   Shenzhen Branch




                                                                         Report No.: SZEM190301204105
                                                                         Page:        1 of 8
1    Cover page


          RF Exposure Evaluation Report
Application No.:                 SZEM1903012041CR
Applicant:                       Alliance Laundry Systems LLC
Address of Applicant:            PO Box 990, Shepard St., Ripon, Wisconsin 54971, United States
Manufacturer:                    Alliance Laundry Systems LLC
Address of Manufacturer:         PO Box 990, Shepard St., Ripon, Wisconsin 54971, United States
Factory:                         Embest Technology Co., Ltd
Address of Factory:              Tower B 4/F, Shanshui Building, Nanshan Yungu Innovation Industry Park,
                                 Liuxian Ave. No.1183, Nanshan District, Shenzhen, Guangdong, China
EUT Name:                        Network Gateway
Model No.:                       204531
FCC ID:                          2ANOT-204531
Standards:                       47 CFR Part 1.1307 (2016)
                                 47 CFR Part 1.1310 (2016)
Date of Receipt:                 2019-03-25
Date of Test:                    2019-03-30 to 2019-04-28
Date of Issue:                   2019-05-06
Test Result :                    PASS*
*   In the configuration tested, the EUT complied with the standards specified above.




            Keny Xu
      EMC Laboratory Manager


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                             Report No.: SZEM190301204105
                                                             Page:       2 of 8

2 Version


                                           Revision Record
       Version       Chapter               Date                  Modifier       Remark

       01                               2019-05-06                              Original




  Authorized for issue by:




                                Leo Lai /Project Engineer




                                Eric Fu /Reviewer


                                                SGS-CSTC Standards Technical Services Co., Ltd.
                                                Shenzhen Branch
                                                                                                      Report No.: SZEM190301204105
                                                                                                      Page:       3 of 8

3         Contents
                                                                                                                                                            Page
1       COVER PAGE .............................................................................................................................................. 1

2       VERSION ...................................................................................................................................................... 2

3       CONTENTS .................................................................................................................................................. 3

4       GENERAL DESCRIPTION OF EUT ............................................................................................................. 4
    4.1     TEST LOCATION .......................................................................................................................................... 5
    4.2     TEST FACILITY ............................................................................................................................................ 5
    4.3     DEVIATION FROM STANDARDS ..................................................................................................................... 5
    4.4     ABNORMALITIES FROM STANDARD CONDITIONS............................................................................................ 5
    4.5     OTHER INFORMATION REQUESTED BY THE CUSTOMER ................................................................................. 5
5       RF EXPOSURE EVALUATION .................................................................................................................... 6
    5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ................................................................................................ 6
       5.1.1 Limits ................................................................................................................................................ 6
       5.1.2 Test Procedure ................................................................................................................................ 6
    4.1.3 EUT RF EXPOSURE EVALUATION ............................................................................................................... 7


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                           Report No.: SZEM190301204105
                                                           Page:       4 of 8


4    General Description of EUT
     Power supply:                 Power by AC/DC adapter
                                   Model: DSA-13PFC-05 FCA
                                   Input: 100-240V~50/60Hz
                                   Output: DC 5.1V 2.5A
For BT:
     Operation Frequency:          2402MHz to 2480MHz
     Spectrum Spread Technology:   Frequency Hopping Spread Spectrum(FHSS)
     Bluetooth Version:            V4.1 Classic
     Modulation Type:              GFSK, π/4DQPSK, 8DPSK
     Number of Channels:           79
     Channel Spacing:              1MHz
     Antenna Type:                 Chip Antenna
     Antenna Gain:                 1.5dBi
For BLE:
     Operation Frequency:          2402MHz to 2480MHz
     Bluetooth Version:            V4.1 LE
     Modulation Type:              GFSK
     Number of Channels:           40
     Channel Spacing:              2MHz
     Antenna Type:                 Chip Antenna
     Antenna Gain:                 1.5dBi
For 2.4G Wifi:
     Operation Frequency:          802.11b/g/n(HT20): 2412MHz to 2462MHz
     Modulation Type:              802.11b: DSSS (CCK, DQPSK, DBPSK)
                                   802.11g/n: OFDM (64QAM, 16QAM, QPSK, BPSK)
     Number of Channels:           802.11b/g/n(HT20):11
     Channel Spacing:              5MHz
     Antenna Type:                 Chip Antenna
     Antenna Gain:                 1.5dBi


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                Report No.: SZEM190301204105
                                                                Page:       5 of 8



4.1 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
    No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
    518057.
    Tel: +86 755 2601 2053     Fax: +86 755 2671 0594
    No tests were sub-contracted.

4.2 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.
4.3 Deviation from Standards
    None.

4.4 Abnormalities from Standard Conditions
    None.

4.5 Other Information Requested by the Customer
    None.


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                                     Report No.: SZEM190301204105
                                                                     Page:       6 of 8


5       RF Exposure Evaluation

5.1     RF Exposure Compliance Requirement
5.1.1 Limits
        According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b)




F= Frequency in MHz
Friis Formula
Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2)
Where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416

R = distance between observation point and center of the radiator in cm
Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to
the antenna, through the calculation, we will know the distance r where the MPE limit is reached.

5.1.2 Test Procedure
        Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
        highest channel individually.


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                   Report No.: SZEM190301204105
                                                                   Page:       7 of 8

4.1.3 EUT RF Exposure Evaluation
Remark: The Bluetooth and Wifi function can’t synchronous transmission at the same time.
For BT
Antenna: 1.5dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.41 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:
 Channel    Frequency      Max Conducted       Output Power          Power Density     Limit    Result
                  (MHz)        Peak Output          to Antenna       at R = 20 cm
                              Power (dBm)             (mW)             (mW/cm2)
  Highest         2480             9.95                9.89             0.0028          1.0     PASS
Note: Refer to report No. SZEM190301204102 for EUT test Max Conducted Peak Output Power value.
The distancer calculated from the Fries transmission formula is far greater than 20 cm separation requirement.

For BLE
Antenna: 1.5dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.41 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:
 Channel    Frequency      Max Conducted       Output Power          Power Density     Limit    Result
                  (MHz)        Peak Output          to Antenna       at R = 20 cm
                              Power (dBm)             (mW)            (mW/cm2)
  Highest         2480             9.9                 9.77             0.0027          1.0     PASS
Note: Refer to report No. SZEM190301204103 for EUT test Max Conducted Peak Output Power value.
The distancer calculated from the Fries transmission formula is far greater than 20 cm separation
requirement.

For 2.4G Wifi
Antenna: 1.5dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.41 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:
 Channel    Frequency      Max Conducted       Output Power          Power Density     Limit    Result
                  (MHz)        Peak Output          to Antenna       at R = 20 cm
                              Power (dBm)             (mW)            (mW/cm2)
  Highest         2462            26.61               458.14            0.1285          1.0     PASS
Note: Refer to report No. SZEM190301204104 for EUT test Max Conducted Peak Output Power value.
The distancer calculated from the Fries transmission formula is far greater than 20 cm separation
requirement.


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                       Report No.: SZEM190301204105
                                                                       Page:       8 of 8

For 2.4G Wifi from FCC ID: VVX-LM820-0462
Antenna: 0dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:
 Channel    Frequency      Max Conducted       Output Power             Power Density         Limit    Result
                (MHz)          Peak Output           to Antenna         at R = 20 cm
                              Power (dBm)                 (mW)           (mW/cm2)
  Lowest        2412               17.89                  61.52               0.0122          1.0      PASS
Note: The distancer calculated from the Fries transmission formula is far greater than 20 cm separation
      requirement.


For LTE from FCC ID: XMR201807EG91NA
Antenna: 4dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 2.51 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:
                                              Power Density
      Band               PG(mW)                     at R = 20 cm                 Limited Value (mW/cm2)
                                                     (mW/cm2)
  LTE Band 12            707.946                          0.141                           0.47
Note: The distancer calculated from the Fries transmission formula is far greater than 20 cm separation
      requirement.


∑ rations of simultaneous transmitting= Wi-Fi + WiFi + LTE property:
 Ratio of Power      Ratio of Power                             Total ratios of
                                           Ratio of Power
  Density for         Density for                               simultaneous
                                           Density for LTE                             Limit          Result
 WIFI at R = 20      WIFI at R = 20                           transmitting at R
                                            at R = 20 cm
       cm                  cm                                      =20cm
      0.1285             0.0122              0.141/0.47              0.4407             1.0           PASS

                                             - End of the Report -



Document Created: 2019-05-29 09:10:01