18_P1 RFExp r1

FCC ID: 2ANMU-P1

RF Exposure Info

Download: PDF
FCCID_3968311

                             Shenzhen Toby Technology Co., Ltd.
                                                                         Report No.: TB-MPE161002
                                                                         Page:       1 of 3


             Maximum Permissible Exposure
                     Evaluation
                                  FCC ID: 2ANMU-P1
1. Client Information
Applicant         : SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
                      A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU
Addres            :
                      INDUSTRIAL ZONE, GUANLAN, LONGHUA, SHENZHEN, CHINA
Manufacturer : SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
                      A2 2F BUILDING ENET NEW INDUSTRIAL PARK, DAFU
Address           :
                      INDUSTRIAL ZONE, GUANLAN, LONGHUA, SHENZHEN, CHINA

2. General Description of EUT
EUT Name                 : Smart Plug
Models No.               : P1
Model Different          : N/A
                           Operation
                                                      802.11b/g/n(HT20): 2412MHz~2462MHz
                           Frequency:
                           RF Output Power:           802.11b: 1.85dBm
                                                      802.11g: 4.67dBm
Product                                               802.11n (HT20): 4.75dBm
                         :
Description
                             Antenna Gain:            1dBi PCB Antenna
                             Modulation Type:         802.11b: DSSS(CCK, DQPSK, DBPSK)
                                                      802.11g/n: OFDM(BPSK,QPSK,16QAM,
                                                      64QAM)
Power Supply       : AC Voltage supplied
                     Input: AC 100~240V, 10A, 50/ 60Hz
Power Rating       :
                     Output: AC 100~240V, 10A, 50/ 60Hz
SoftwareVersion    : VI.0
Hardware Version   : V1.0
Connecting     I/O : Please refer to the User's Manual
Port(S)


                                                                                            TB-RF-075-1.0

         1A/F., Bldg.6, Yusheng Industrial Zone, The National Road No.107 Xixiang Section 467, Xixiang,
                                    Bao’an, Shenzhen, China
                                Tel: +86 75526509301       Fax: +86 75526509195


                                                                          Report No.: TB-MPE161002
                                                                          Page:       2 of 3


                                 MPE Calculations for WIFI

1. Antenna Gain:
                    PCB Antenna: 1dBi.

2. EUT Operation Condition:
   Software provided by client enabled the EUT to transmit and receive data at lowest, middle
   and highest channel individually.

3. Exposure Evaluation:
   Equation from page 18 of OET Bulletin 65, Edition 97-01
     S=(PG)/4πR2
   Where
      S: power density
      P: power input to the antenna
      G: power gain of the antenna in the direction of interest relative to an isotropic radiator.
      R: distance to the center of radiation of the antenna

4. Test Result:
                        Conducted                Max tune up                             Power
                                      Turn-up                  ANT Gain    Distance     Density
                        Power(max)                 power
          Mode                         Power                     (dBi)       (cm)              2
                          (dBm)                     (dBm)                              (mW/ cm )
                                        (dB)                      [G]         [R]
                                                      [P]                                 [S]

        802.11b           1.85        1±1            2           1           20         0.00040

        802.11g           4.67        5±1            6           1           20         0.00100

        802.11n
                          4.75        5±1            6           1           20         0.00100
         (HT20)




                                                                                       TB-RF-075-1.0


                                                                       Report No.: TB-MPE161002
                                                                       Page:       3 of 3


5. Conclusion:
As specified in Table 1B of 47 CFR 1.1310- Limits for Maximum Permissible Exposure (MPE),
                 Limits for General Population/ Uncontrolled Exposure
                        Frequency Range               Power density
                              (MHz)                     (mW/ cm2)
                            300-1,500                    F/1500
                          1,500-100,000                     1.0

  For 802.11b/g/n:2412~2462 MHz
  MPE limit S: 1mW/ cm2
  The MPE is calculated as 0.00100/ cm2 < limit 1mW / cm2. So, RF exposure limit warning
  or SAR test are not required.

  The EUT will only be used with a separation of 20cm or greater between the antenna and
  nearby persons and can therefore be considered a mobile transmitter per 47 CFR2.1091
  (b).

  The RF Exposure Information page from the manual is included here for reference.


Note
   For a more detailed features description, please refer to the RF Test Report.




                                  -----END OF REPORT-----




                                                                                   TB-RF-075-1.0



Document Created: 2018-08-16 10:56:22
Document Modified: 2018-08-16 10:56:22

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC