RF Exposure

FCC ID: 2ANJPAFCC01-10W

RF Exposure Info

Download: PDF
FCCID_4134778

                            Shenzhen BCTC Testing Co., Ltd.        Report No.: BCTC-FY181206917-1E




                    RF EXPOSURE REPORT
                              For
                   FCC ID: 2ANJPAFCC01-10W

Product Name:       Wireless charging

Trademark:          N/A


Model Number:       AFCC01-10W


Prepared For :      SHENZHEN AVATARCONTROLS CO., LTD.

                    Room 502, 5F, W1-A Block, High-Tech Industrial Park, Nanshan District, Shenzhen,
Address :
                    Guangdong, China

Prepared By :       Shenzhen BCTC Testing Co., Ltd.

                    BCTC Building & 1-2F, East of B Building, Pengzhou Industrial, Fuyuan 1st Road,
Address :
                    Qiaotou Community, Fuyong Street, Bao’an District, Shenzhen, China

Test Date:          Dec. 20, 2018 – Jan. 02, 2019


Date of Report :    Jan. 02, 2019


Report No.:         BCTC-FY181206917-1E


                                 Shenzhen BCTC Testing Co., Ltd.           Report No.: BCTC-FY181206917-1E




                                 TEST RESULT CERTIFICATION

Applicant’s name ................. : SHENZHEN AVATARCONTROLS CO., LTD.
Address ................................. : Room 502, 5F, W1-A Block, High-Tech Industrial Park, Nanshan
                                       District, Shenzhen, Guangdong, China
Manufacture's Name ............ : SHENZHEN AVATARCONTROLS CO., LTD.
Address ................................. : Room 502, 5F, W1-A Block, High-Tech Industrial Park, Nanshan
                                       District, Shenzhen, Guangdong, China
Product description
Product name ........................... : Wireless charging
Trademark ............................ : N/A
Model and/or type reference          : AFCC01-10W
Serial Model                         : N/A
Power Supply                           Input: 24V/0.5A
                                       Output: 5V*2A
Model Difference                     : N/A

Standards ............................. : FCC CFR 47 part1, 1.1307(b), 1.1310
This device described above has been tested by BCTC, and the test results show that the
equipment under And it is applicable only to the tested sample identified in the report.
This report shall not be reproduced except in full, without the written approval of BCTC, this
document may be altered or revised by BCTC, personal only, and shall be noted in the revision of
the document.




  Prepared by(Engineer):               Lake Xie


   Reviewer(Supervisor):               Eric Yang


      Approved(Manager):               Carson Zhang




EMF      Tel: 400-788-9558      0755-33019988              Web:Http//www.bctc-lab.com.cn       Page 2 of 12


                            Shenzhen BCTC Testing Co., Ltd.       Report No.: BCTC-FY181206917-1E




                                  Table of Contents                                 Page


 1 . GENERAL INFORMATION                                                                4
      1.1 . Independent Operation Mode                                                   4
      1.2 . Test Supporting System                                                       4
 2 .LIST OF TEST AND MEASUREMENT INSTRUMENTS                                            5
      2.1 . For conducted emission at the mains terminals test                           5
 3. METHOD OF MEASUREMENT                                                               6
 3. 1.Applicable Standard                                                               6
 3. 2. Test Modes                                                                       6
 3. 3. MAXIMUM PERMISSIBLE EXPOSURE                                                     6
 4. TEST RESULT                                                                         7
 4.1. Conducted Emission at the Mains Terminals Test                                    7
 4.2. Equipment Approval Considerations:                                                8
 4.3. E and H field Strength                                                            9
 5. Photographs of test set-up                                                         10




EMF     Tel: 400-788-9558   0755-33019988         Web:Http//www.bctc-lab.com.cn     Page 3 of 12


                            Shenzhen BCTC Testing Co., Ltd.      Report No.: BCTC-FY181206917-1E


1. GENERAL INFORMATION
1.1. Independent Operation Mode

      The basic operation mode is:

      1.1.1. Charging


1.2. Test Supporting System

      Adapter
      Description : Adapter
      Model No. : BCTC-002
      Power Input : AC 100-240V~50/60Hz
      Output: 24     1A

      DC Line : Unshielded, Detachable 1m

      Mobile phone
      Model No. : iPhone8




EMF     Tel: 400-788-9558   0755-33019988        Web:Http//www.bctc-lab.com.cn     Page 4 of 12


                            Shenzhen BCTC Testing Co., Ltd.      Report No.: BCTC-FY181206917-1E


 2.LIST OF TEST AND MEASUREMENT INSTRUMENTS
 2.1. For conducted emission at the mains terminals test

 Equipment       Manufacturer      Model No.      Serial No.     Last Cal.         Next Cal.
  Exposure
                    Narda           ELT-400        N-0231      Aug. 08, 2017     Aug. 07, 2019
Level Tester
Magnetic field                   B-Field Probe
                    Narda                           M0675      Aug. 08, 2017     Aug. 07, 2019
probe 100cm2                        100cm2
843 Chamber          ETS              843           84301      Aug. 27, 2017     Aug. 26, 2019




EMF     Tel: 400-788-9558   0755-33019988        Web:Http//www.bctc-lab.com.cn       Page 5 of 12


                           Shenzhen BCTC Testing Co., Ltd.      Report No.: BCTC-FY181206917-1E


3. METHOD OF MEASUREMENT

3. 1.Applicable Standard
 According to §1.1307(b)(1), systems operating under the provisions of this section shall be
 operated in a manner that ensures that the public is not exposed to radio frequency energy
 level in excess of the Commission’s guidelines. According to §1.1310 and §2.1093 RF
 exposure is calculated. According KDB680106 D01v03: RF Exposure Wireless Charging
 Apps v02.

3. 2. Test Modes

      Test Modes                     keeping TX+Charging mode


3. 3. MAXIMUM PERMISSIBLE EXPOSURE




EMF    Tel: 400-788-9558   0755-33019988        Web:Http//www.bctc-lab.com.cn     Page 6 of 12


                             Shenzhen BCTC Testing Co., Ltd.        Report No.: BCTC-FY181206917-1E

 4. TEST RESULT
 4.1. Conducted Emission at the Mains Terminals Test




Note: Measurements should be made from all sides and the top of the primary/client pair, with the 15
cm measured from the center of the probe(s) to the edge of the device

Test Procedure:

a) The RF exposure test was performed on 360 degree turn table in anechoic chamber.
b) The measurement probe was placed at test distance (15cm) which is between the edge of
the charger and the geometric centre of probe.
c) The turn table was rotated 360d degree to search of highest strength.
d) The highest emission level was recorded and compared with limit as soon as measurement
of each points (A, B, C, D, E) were completed.
e) The EUT were measured according to the dictates of KDB 680106D01v03.




 EMF     Tel: 400-788-9558   0755-33019988         Web:Http//www.bctc-lab.com.cn       Page 7 of 12


                            Shenzhen BCTC Testing Co., Ltd.       Report No.: BCTC-FY181206917-1E

4.2. Equipment Approval Considerations:
      The EUT does comply with item 5(b) of KDB 680106 D01v03

      1) Power transfer frequency is less than 1MHz
        Yes, the device operate in the frequency range from 120 KHz to 205 KHz

      2) Output power from each primary coil is less than or equal to 15 watts.

         Yes, the maximum output power of the primary coil is 10W.

      3) The transfer system includes only single primary and secondary coils. This includes
        charging systems that may have multiple primary coils and clients that able to detect
        and allow coupling onlybetween individual pair of coils.

        Yes, the transfer system includes only single primary and secondary coils.

      4) Client device is inserted in or placed directly in contact with the transmitter.

        Yes, client device is placed directly in contact with the transmitter.

      5) Mobile exposure conditions only (portable exposure conditions are not covered by
        this exclusion).

        Yes, the EUT is a Mobile Wireless Charger

      6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above
        the top surface from all simultaneous transmitting coils are demonstrated to be less
        than 50% of the MPE limit.

        Yes, the EUT field strength levels are 50% x MPE limit.




EMF     Tel: 400-788-9558   0755-33019988         Web:Http//www.bctc-lab.com.cn      Page 8 of 12


                                Shenzhen BCTC Testing Co., Ltd.              Report No.: BCTC-FY181206917-1E

4.3. E and H field Strength
      (The worst data)

       E-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the EUT
       Battery     Frequency      Test        Test       Test       Test       Test       Test      50%     Limits
        level    Range (MHz)     Position   Position   Position   Position   Position   Position   Limits    Test

                                    A           B          C         D          E           F       Test    (V/m)

                                                                                                   (V/m)

         1%       0.110-0.205     0.75        0.54       0.53       0.68       0.51       0.65      307      614

        50%       0.110-0.205     0.60        0.46       0.51       0.57       0.48       0.61      307      614

        99%       0.110-0.205     0.55        0.42       0.46       0.53       0.47       0.57      307      614

       H-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the EUT
       Battery    Frequency       Test       Test       Test       Test       Test       Test      50%      Limits
        level    Range (MHz)    Position    Position   Position   Position   Position   Position   Limits   Test

                                   A           B          C          D          E          F       Test     (A/m)

                                                                                                   (A/m)

        1%       0.110-0.205      0.22       0.17       0.14       0.18       0.13       0.16      0.815    1.63

        50%      0.110-0.205      0.17       0.14       0.15       0.19       0.10       0.12      0.815    1.63

        99%      0.110-0.205      0.13       0.07       0.11       0.16       0.09       0.05      0.815    1.63




EMF      Tel: 400-788-9558      0755-33019988             Web:Http//www.bctc-lab.com.cn            Page 9 of 12


                          Shenzhen BCTC Testing Co., Ltd.      Report No.: BCTC-FY181206917-1E

5. Photographs of test set-up




EMF   Tel: 400-788-9558   0755-33019988        Web:Http//www.bctc-lab.com.cn     Page 10 of 12


                          Shenzhen BCTC Testing Co., Ltd.      Report No.: BCTC-FY181206917-1E




EMF   Tel: 400-788-9558   0755-33019988        Web:Http//www.bctc-lab.com.cn     Page 11 of 12


                          Shenzhen BCTC Testing Co., Ltd.      Report No.: BCTC-FY181206917-1E




                            ※※※※※ END OF REPORT ※※※※※




EMF   Tel: 400-788-9558   0755-33019988        Web:Http//www.bctc-lab.com.cn     Page 12 of 12



Document Created: 2019-03-29 07:27:24
Document Modified: 2019-03-29 07:27:24

© 2024 FCC.report