RF Exposure Report

FCC ID: 2ANI5SA200

RF Exposure Info

Download: PDF
FCCID_4379082

                                                         FCC MPE REPORT
                                                                          Certification

Applicant Name:                                                                          Date of Issue:
Safetrust Inc                                                                            July 12, 2019
                                                                                         Test Site/Location:
Address:                                                                                 EMCE Engineering
8116 Mill Creek Rd.                                                                      1726 Ringwood Avenue San Jose, California USA
Fremont, CA 94539, U.S.A.                                                                Report No.: EMCE-R-1907-F005


FCC ID:                                        2ANI5SA200
IC:                                            23133-SA200
APPLICANT:                                     Safetrust Inc

Model:                                         SA200

Additional Model:                              N/A

EUT Type:                                      SABRE Module




   The measurements shown in this report were made in accordance with the procedures specified in §2.947. I assume full responsibility for the


   accuracy and completeness of these measurements, and for the qualifications of all persons taking them.


   EMCE Engineering, Inc. Certifies that no party to this application has subject to a denial of Federal benefits that includes FCC benefits pursuant


   to section 5301 of the Anti-Drug Abuse Act of 1998,21 U.S. C.853(a)




   Steve In                                                                              Billy Kim
   Test Engineer                                                                         Technical Manager
   Certification Division                                                                Certification Division
   This report only responds to the tested sample and may not be reproduced, except in full, without written approval of the EMCE Engineering, Inc..




Report No.: EMCE-R-1907-F005
                                                                                                                                                       1/4

      This document may not be copied or reproduced (reprinted) without written consent by EMCE Engineering, Inc.
                      EMCE Engineering, Inc., 1726 Ringwood Avenue, San Jose, CA 95131, USA
                                   TEL: +1-510-933-8848 FAX: +1-510-933-8849


                                                 Version
       TEST REPORT NO.                   DATE                                     DESCRIPTION

       EMCE-R-1907-F005              July 12, 2019                           - First Approval Report




Report No.: EMCE-R-1907-F005
                                                                                                                   2/4

     This document may not be copied or reproduced (reprinted) without written consent by EMCE Engineering, Inc.
                     EMCE Engineering, Inc., 1726 Ringwood Avenue, San Jose, CA 95131, USA
                                  TEL: +1-510-933-8848 FAX: +1-510-933-8849


   RF Exposure Statement
   1. LIMITS
   According to §1.1310 and §2.1091 RF exposure is calculated.


                                 (B) Limits for General Population/Uncontrolled Exposures

              Frequency range                     Electric field       Magneticfield          Power density    Averaging time
                   (MHz)                         Strength (V/m)      Strength (A/m)             (mW/cm²)         (minutes)




 0.3 - 1.34…………………………………                                   614                   1.63                *(100)                 30
 1.34 - 30…………………………………                                   824/f                2.19/f             *(180/ f²)                30
 30 - 300…………………………………                                     27.5                0.073                     0.2                30
 300 - 1500………………………………                                 …………...              …………...                 f/1500                 30
 1500 - 100.000……………………………                              …………...              …………...                     1.0                30



        F = frequency in MHz
        * = Plane-wave equivalent power density



   2. MAXIMUM PERMISSIBLE EXPOSURE Prediction
   Prediction of MPE limit at a given distance


   S = PG/4πR²

   S = Power density
   P = power input to antenna
   G = power gain of the antenna in the direction of interest relative to an isotropic radiator
   R = distance to the center of radiation of the antenna




Report No.: EMCE-R-1907-F005
                                                                                                                           3/4

     This document may not be copied or reproduced (reprinted) without written consent by EMCE Engineering, Inc.
                     EMCE Engineering, Inc., 1726 Ringwood Avenue, San Jose, CA 95131, USA
                                  TEL: +1-510-933-8848 FAX: +1-510-933-8849


   3. RESULTS

   3-1. Bluetooth
   Average output Power at antenna input terminal                    1.74             dBm

   Average output Power at antenna input terminal                    1.49             mW

   Prediction distance                                               20.000           cm

   Prediction frequency                                              2402 ~ 2480      MHz

   Antenna Gain(typical)                                             2.0              dBi

   Antenna Gain(numeric)                                             1.59             -

   Power density at prediction frequency( S)                         0.000471         mW/cm2

   MPE limit for uncontrolled exposure at prediction frequency       1.000            mW/cm2

   3-2. DTS

   Average output Power at antenna input terminal                    18.75            dBm

   Average output Power at antenna input terminal                    74.99            mW

   Prediction distance                                               20.000           cm

   Prediction frequency                                              2 412 ~ 2 462    MHz

   Antenna Gain(typical)                                             2                dBi

   Antenna Gain(numeric)                                             1.59             -

   Power density at prediction frequency( S)                         0.023645         mW/cm2

   MPE limit for uncontrolled exposure at prediction frequency       1.000            mW/cm2



   -> Worst Case: Simultaneous MPE 20cm is

   Simultaneous MPE 20cm is WLAN(2.4 GHz) (0.023645/1.0) + Bluetooth (0.000471/1.0) = 0.024116 < 1




Report No.: EMCE-R-1907-F005
                                                                                                                   4/4

     This document may not be copied or reproduced (reprinted) without written consent by EMCE Engineering, Inc.
                     EMCE Engineering, Inc., 1726 Ringwood Avenue, San Jose, CA 95131, USA
                                  TEL: +1-510-933-8848 FAX: +1-510-933-8849



Document Created: 2019-07-16 10:08:52
Document Modified: 2019-07-16 10:08:52

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC