Test Report

FCC ID: 2ANDR-AC0011807

Test Report

Download: PDF
FCCID_4278687

                               FCC PART 15B
                     ICES-003, ISSUE 6, JANUARY 2016

                                              TEST REPORT
                                                             For

                       SZ DJI Osmo Technology Co.,Ltd.
2F, Building 3, Binhai Mingzhu Industrial Park No. 291 Louming Road, Xinhu Street Guangming
                                  District, Shenzhen, China


                                           Model: AC001
                                     FCC ID: 2ANDR-AC0011807



           Report Type:                                          Product Type:
           Original Report                                      OSMO ACTION

                 Report Number:           RDG190117002-00A

                      Report Date:        2019-01-29


                     Reviewed By:         Jerry Zhang
                                          EMC Manager
                                          Bay Area Compliance Laboratories Corp. (Dongguan)
                                          No.69 Pulongcun, Puxinhu Industry Area,
                                          Tangxia, Dongguan, Guangdong, China
                Test Laboratory:
                                          Tel: +86-769-86858888
                                          Fax: +86-769-86858891
                                          www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan).This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal
Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                     Report No.: RDG190117002-00A




                                                      TABLE OF CONTENTS

General Information ..................................................................................................................................................... 3
  PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .................................................................................... 3
  OBJECTIVE .................................................................................................................................................................. 3
  RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................ 3
  TEST METHODOLOGY .................................................................................................................................................. 3
  MEASUREMENT UNCERTAINTY ................................................................................................................................... 3
  TEST FACILITY ............................................................................................................................................................ 4
System Test Configuration ........................................................................................................................................... 5
  DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 5
  EQUIPMENT MODIFICATIONS ....................................................................................................................................... 5
  EUT EXERCISE SOFTWARE ......................................................................................................................................... 5
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................ 5
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................ 5
  BLOCK DIAGRAM OF TEST SETUP ............................................................................................................................... 6
  TEST EQUIPMENT LIST ................................................................................................................................................ 7
  ENVIRONMENTAL CONDITIONS ................................................................................................................................... 7
Summary of Test Results.............................................................................................................................................. 8
Conducted emissions ..................................................................................................................................................... 9
  EUT SETUP ................................................................................................................................................................. 9
  EMI TEST RECEIVER SETUP ........................................................................................................................................ 9
  TEST PROCEDURE ........................................................................................................................................................ 9
  TEST DATA ................................................................................................................................................................ 11
Radiated emissions ...................................................................................................................................................... 13
  EUT SETUP ............................................................................................................................................................... 13
  EMI TEST RECEIVER SETUP ...................................................................................................................................... 14
  TEST PROCEDURE ...................................................................................................................................................... 14
  CORRECTED AMPLITUDE & MARGIN CALCULATION ................................................................................................. 14
  TEST DATA ................................................................................................................................................................ 15




                                                                                                                                                         Page 2 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                     Report No.: RDG190117002-00A


GENERAL INFORMATION

Product Description for Equipment under Test (EUT)

                        EUT Name:      OSMO ACTION
                        EUT Model:     AC001
                Rated Input Voltage:   DC3.85V from Battery
   The Highest Operating Frequency:    5825MHz
                External Dimension:    65mm(L)* 42mm(W)*35mm(H)
                     Serial Number:    190117002
                EUT Received Date:     2019.01.17



Objective

This report is prepared on behalf of SZ DJI Osmo Technology Co.,Ltd. in accordance with FCC Part 15B
Part 2, subpart J, and Part 15, Subpart A and B of the Federal Communications Commission’s rules, and
ICES-003, Issue 6, January 2016 Information Technology Equipment (Including Digital Apparatus) —
Limits and Methods of Measurement.

The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15 B Class B, and
ICES-003, Issue 6, January 2016.


Related Submittal(s)/Grant(s)

FCC Part 15C DTS submissions with FCC ID: 2ANDR-AC0011807.
FCC Part 15E NII submissions with FCC ID: 2ANDR-AC0011807.


Test Methodology

All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratories
Corp. (Dongguan).


Measurement Uncertainty

                         Parameter                         Measurement Uncertainty

                                                    30M~200MHz: 4.55 dB,200M~1GHz: 5.92
                Unwanted Emissions, radiated         dB,1G~6GHz: 4.98 dB, 6G~18GHz: 5.89
                                                    dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB

                       Temperature                                    ±1℃
                         Humidity                                     ±5%
             AC Power Lines Conducted Emission            3.12 dB (150 kHz to 30 MHz)




                                                                                           Page 3 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                     Report No.: RDG190117002-00A


Test Facility

The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier : CN0022.




                                                                                           Page 4 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190117002-00A


SYSTEM TEST CONFIGURATION

Description of Test Configuration

The system was configured for testing in operating and downloading mode.


Equipment Modifications

No modification was made to the EUT.


EUT Exercise Software

The software "Winthrax.exe" was used during test.


Local Support Equipment List and Details

       Manufacturer           Description             Model                       Serial Number
           DELL                   Laptop              PP11L                      QDS-BRCM1017
            HP                    Printer             C3941A                       JPTVOB2337
           DELL                  Keyboard              L100                CNORH656658907BL05DC
           SAST                  Modem               AEM-2100                             293
          SanDisk           Micro SD card                  4G                              /



Support Cable List and Details

                        Shielding       Ferrite     Length
  Cable Description       Type           Core                        From Port                    To
                                                     (m)
     Serial Cable          Yes              No       1.2        Serial Port of Laptop           Modem
   Keyboard Cable          Yes              Yes      1.2              Keyboard             USB Port of Laptop
    Parallel Cable         Yes              No       1.2        Parallel Port of Laptop         Pribter
     USB Cable             Yes              No       0.5                 EUT                    Laptop




                                                                                                  Page 5 of 22


                   TT T TT M M T   T T TT   NT   T O e O TTOCOOCOCOS




LISN2                                                                                                                  LISN1




                                                                           |         |                                 A
         Printer   |«!0cm»| Modem                 |<«l0Ocm»            Laptop   4«10cm»|   EUT   |«1i0cm»|   Adapter




                                                                                                                       =
                                                                                                                       <.
                                                                                                                       C
                                                                                                                       CD




      Non—Conductive Table 80
      cm above Ground Plane
                                                                          Keyboard
 «s                                                                1.5 Meter


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190117002-00A


Test Equipment List

                                                                      Serial       Calibration    Calibration
   Manufacturer       Description              Model
                                                                     Number           Date         Due Date
                                             Conducted emissions
                       EMI Test
        R&S                                   ESCS 30               830245/006      2018-12-10    2019-12-10
                       Receiver
     Unknown         Coaxial Cable           C-NJNJ-50              C-0200-01       2018-09-05    2019-09-05
                       Two-line
        R&S                                   ENV 216                 101614        2018-12-10    2019-12-10
                      V-network
        R&S             L.I.S.N             ESH2-Z5             892107/021          2018-09-19    2019-09-19
        R&S          Test Software           EMC32             Version8.53.0           N/A           N/A
                                       Radiated emissions Below 1GHz
                       EMI Test
        R&S                                     ESCI                  100224        2018-12-10    2019-12-10
                       Receiver
   Sunol Sciences      Antenna                 JB3               A060611-1          2017-11-10    2020-11-10
     Unknown         Coaxial Cable          C-NJNJ-50            C-0400-01          2018-09-05    2019-09-05
     Unknown         Coaxial Cable          C-NJNJ-50            C-0075-01          2018-09-05    2019-09-05
     Unknown         Coaxial Cable          C-NJNJ-50            C-1400-01          2018-05-06    2019-05-06
        HP             Amplifier              8447D             2727A05902          2018-09-05    2019-09-05
       Farad         Test Software           EZ-EMC               V1.1.4.2             N/A           N/A
                                       Radiated emissions Above 1GHz
                      Spectrum
      Agilent                                  E4440A              SG43360054       2019-01-04    2020-01-04
                       Analyzer
                      Spectrum
        R&S                                    FSP 38                 100478        2018-12-10    2019-12-10
                       Analyzer
   ETS-Lindgren      Horn Antenna               3115                000 527 35      2018-10-12    2021-10-12
    Ducommun                                                        1007726-01
                     Horn Antenna           ARH-4223-02                             2016-11-18    2019-11-18
   Technolagies                                                        1304
    Ducommun                                                        1007726-01
                     Horn Antenna           ARH-2823-02                             2016-11-18    2019-11-18
   Technolagies                                                        1302
     Unknown         Coaxial Cable          C-SJSJ-50               C-0800-01       2018-09-05    2019-09-05
     Unknown         Coaxial Cable        C-2.4J2.4J-50              C-0700-02      2018-06-27    2019-06-27
      MITEQ           Amplifier       AFS42-00101800-25-S-42          2001271       2018-09-05    2019-09-05
      Quinstar         Amplifier         QLW-18405536-JO           15964001001      2018-06-27    2019-06-27
       Farad         Test Software            EZ-EMC                 V1.1.4.2          N/A            N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Environmental Conditions

                                              Radiated           Radiated
                         Conducted
        Test Item:                            emissions       emissions Above
                         emissions
                                            Below 1GHz             1GHz
       Test Date:        2019-01-25          2019-01-27         2019-01-23
          Tester:         Lily Xie            Neil Liao          Tyler Pan
    Temperature:           22.9oC               24oC              21.2oC
         Relative
                             33%                32 %                35 %
       Humidity:
   ATM Pressure:          100.5kPa             101kPa             100.6kPa




                                                                                                     Page 7 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RDG190117002-00A


SUMMARY OF TEST RESULTS

           Rule and Clause                 Description of Test          Test Result
            FCC §15.107
                                          Conducted emissions           Compliance
         ICES-003 Clause 6.1
            FCC §15.109
                                           Radiated emissions           Compliance
         ICES-003 Clause 6.2




                                                                                      Page 8 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190117002-00A


CONDUCTED EMISSIONS

EUT Setup




The setup of EUT is according with per ANSI C63.4-2014 measurement procedure. The specification used
was with the FCC Part 15 B and Innovation, Science and Economic Development Canada ICES-003 Class
B limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The adapter was connected to the Main LISN with 120V/60Hz AC power source.


EMI Test Receiver Setup

The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                             Frequency Range                       IF B/W
                             150 kHz – 30 MHz                       9 kHz



Test Procedure

During the conducted emission test, the adapter of Laptop was connected to the outlet of the first LISN
and the other support equipments were connected to the outlet of the second LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.




                                                                                             Page 9 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190117002-00A

Corrected Amplitude & Margin Calculation

The basic equation is as follows:

VC = VR + AC + VDF

Herein,
VC: corrected voltage amplitude

VR: reading voltage amplitude

Ac: attenuation caused by cable loss

VDF: voltage division factor of AMN or ISN

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

                                    Margin = Limit – Corrected Amplitude




                                                                                         Page 10 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                                              Report No.: RDG190117002-00A



Test Data

Please refer to following table and plots:

 Model Number:                                        AC001
 Port:                                                L
 Test Mode:                                           Downloading
 Power Source:                                        AC120V/60Hz



                       80

                       70
                                                                                                       Quasi-Peak Limit
                       60

                                                                                                          Average Limit
                       50
        Level in dBμ




                       40

                       30

                       20

                       10

                        0
                        150k         300    400 500     800 1M           2M    3M    4M 5M 6   8 10M         20M     30M

                                                                   Frequency in Hz



Final Result 1
 Frequency                  QuasiPeak      Bandwidth     Line    Corr.   Margin       Limit
   (MHz)                     (dBμV)          (kHz)               (dB)     (dB)       (dBμV)
   0.167702                       53.3          9.000    L1       10.9      11.8        65.1
   0.216409                       45.3          9.000    L1       10.5      17.7        63.0
   0.259937                       39.1          9.000    L1       10.3      22.3        61.4
   0.511698                       34.8          9.000    L1        9.9      21.2        56.0
  17.183363                       40.5          9.000    L1       10.0      19.5        60.0
  18.460903                       38.4          9.000    L1       10.0      21.6        60.0



Final Result 2
 Frequency                   Average       Bandwidth     Line    Corr.   Margin       Limit
   (MHz)                     (dBμV)          (kHz)               (dB)     (dB)       (dBμV)
   0.157346                       36.5          9.000    L1       11.1      19.1        55.6
   0.163741                       34.3          9.000    L1       11.0      21.0        55.3
   0.173134                       37.7          9.000    L1       10.9      17.1        54.8
   0.225205                       29.9          9.000    L1       10.5      22.7        52.6
  16.644319                       36.1          9.000    L1       10.0      13.9        50.0
  17.881783                       31.4          9.000    L1       10.0      18.6        50.0




                                                                                                                          Page 11 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                                             Report No.: RDG190117002-00A




 Model Number:                                       AC001
 Port:                                               N
 Test Mode:                                          Downloading
 Power Source:                                       AC120V/60Hz



                      80

                      70
                                                                                                      Quasi-Peak Limit
                      60

                                                                                                         Average Limit
                      50
       Level in dBμ




                      40

                      30

                      20

                      10

                       0
                       150k         300    400 500     800 1M           2M    3M    4M 5M 6   8 10M         20M     30M

                                                                  Frequency in Hz



Final Result 1
 Frequency                 QuasiPeak      Bandwidth     Line    Corr.   Margin       Limit
   (MHz)                    (dBμV)          (kHz)               (dB)     (dB)       (dBμV)
   0.151200                      53.9          9.000    N        11.1      12.0        65.9
   0.174519                      51.7          9.000    N        10.8      13.0        64.7
   0.243884                      36.2          9.000    N        10.3      25.8        62.0
   0.262017                      38.7          9.000    N        10.3      22.7        61.4
  16.512221                      41.0          9.000    N         9.9      19.0        60.0
  18.169036                      39.2          9.000    N        10.0      20.8        60.0



Final Result 2
 Frequency                  Average       Bandwidth     Line    Corr.   Margin       Limit
   (MHz)                    (dBμV)          (kHz)               (dB)     (dB)       (dBμV)
   0.162441                      35.9          9.000    N        11.0      19.4        55.3
   0.207957                      29.9          9.000    N        10.6      23.4        53.3
   0.483938                      23.2          9.000    N         9.9      23.1        46.3
   1.488418                      23.4          9.000    N         9.8      22.6        46.0
  16.381172                      33.6          9.000    N         9.9      16.4        50.0
  17.881783                      32.7          9.000    N        10.0      17.3        50.0




                                                                                                                         Page 12 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                    Report No.: RDG190117002-00A


RADIATED EMISSIONS

EUT Setup

Below 1GHz:




Above 1GHz:




The radiated emission below 1GHz tests were performed in the 3 meters chamber test site A, above 1GHz
tests were performed in the 3 meters chamber test site B, 1GHz-26.5GHz were performed at the 3 m
distance and 26.5-30 GHz was performed at 1 m distance, using the setup accordance with the ANSI
C63.4-2014. The specification used was with the FCC Part 15 B and Innovation, Science and Economic
Development Canada ICES-003 Class B limits.




                                                                                        Page 13 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190117002-00A



EMI Test Receiver Setup

The system was investigated from 30 MHz to 30 GHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:

             Frequency Range             RBW          Video B/W        IF B/W      Measurement
            30 MHz – 1000 MHz           120 kHz         300 kHz        120 kHz           QP
                                        1 MHz           3 MHz              /            Peak
               Above 1 GHz                           Reduced video
                                        1 MHz                              /           AVG
                                                      bandwidth

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is
unnecessary to perform an QP/Average measurement.


Test Procedure

During the radiated emissions, the adapter of laptop was connected to the first AC floor outlet and the
other support equipments were connected to the second AC floor outlet.

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

The data was recorded in the Quasi-peak detection mode for below 1 GHz, peak and average detection
mode above 1 GHz.

According to C63.4, the above 1G test result shall be extrapolated to the specified distance using an
extrapolation factor of 20dB/decade from 3m to 1 m
Distance extrapolation factor =20 log (specific distance [3m]/test distance [1m]) dB= 9.54 dB


Corrected Amplitude & Margin Calculation

The basic equation is as follows:

Result = Meter Reading+ Corrected

Note:
Corrected = Antenna Factor + Cable Loss - Amplifier Gain
or
Corrected = Antenna Factor + Cable Loss + Distance extrapolation factor - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation
is as follows:

                                        Margin = Limit – Result




                                                                                               Page 14 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190117002-00A



Test Data

Please refer to following table and plots:

Condition:          FCC Part 15B Class B                     Polarization:              Horizontal
EUT:                OSMO ACTION                              Power:                     AC 120V/60Hz
Model:              AC001                                    Distance:                  3m
Test Mode:          Downloading




     Frequency       Reading       Detector    Corrected      Result           Limit         Margin
       (MHz)         (dBμV)                     (dB/m)      (dBμV/m)         (dBμV/m)         (dB)
     30.0000          25.76          peak           1.72     27.48            40.00          12.52
     119.2400         35.44          peak           -4.84    30.60            43.50          12.90
     210.4200         44.47           QP            -7.37    37.10            43.50           6.40
     359.8000         45.60           QP            -2.80    42.80            46.00           3.20
     600.3600         32.88          peak           1.03     33.91            46.00          12.09
     799.2100         31.02          peak           4.40     35.42            46.00          10.58




                                                                                             Page 15 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190117002-00A




Condition:         FCC Part 15B Class B                      Polarization:              Vertical
EUT:               OSMO ACTION                               Power:                     AC 120V/60Hz
Model:             AC001                                     Distance:                  3m
Test Mode:         Downloading




     Frequency      Reading       Detector     Corrected      Result           Limit         Margin
       (MHz)        (dBμV)                      (dB/m)      (dBμV/m)         (dBμV/m)         (dB)
     30.0000         26.93         peak             1.72     28.65            40.00          11.35
     210.4200        41.73         peak             -7.37    34.36            43.50           9.14
     359.8000        38.15         peak             -2.80    35.35            46.00          10.65
     472.3200        34.50         peak             -0.40    34.10            46.00          11.90
     600.3600        32.54         peak             1.03     33.57            46.00          12.43
     934.0400        38.71         peak             -3.43    35.28            46.00          10.72




                                                                                             Page 16 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190117002-00A




Condition:         FCC Part 15 Class B                        Polarization:           Horizontal
EUT:               OSMO ACTION                                Power:                  AC 120V/60Hz
Model:             AC001                                      Distance:               3m
Test Mode:         Downloading




   Frequency      Reading       Detector      Corrected     Result        Limit          Margin
   (MHz)          (dBμV)                      (dB/m)        (dBμV/m)      (dBμV/m)       (dB)
     1943.500        64.30         peak             -7.39      56.91          74.00        17.09
     1943.500        43.15         AVG              -7.39      35.76          54.00        18.24
     3184.500        54.93         peak             -4.24      50.69          74.00        23.31
     3184.500        37.52         AVG              -4.24      33.28          54.00        20.72
     17983.000       46.06         peak             17.02      63.08          74.00        10.92
     17983.000       30.10         AVG              17.02      47.12          54.00        6.88




                                                                                           Page 17 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190117002-00A




Condition:         FCC Part 15 Class B                          Polarization:           Vertical
EUT:               OSMO ACTION                                  Power:                  AC 120V/60Hz
Model:             AC001                                        Distance:               3m
Test Mode:         Downloading




   Frequency      Reading       Detector      Corrected     Result        Limit           Margin
   (MHz)          (dBμV)                      (dB/m)        (dBμV/m)      (dBμV/m)        (dB)
     1799.000        60.71         peak             -7.77      52.94            74.00       21.06
     1799.000        42.36         AVG              -7.77      34.59            54.00       19.41
     4782.500        50.38         peak             -1.18      49.20            74.00       24.80
     4782.500        35.69         AVG              -1.18      34.51            54.00       19.49
     17889.500       46.52         peak             16.34      62.86            74.00       11.14
     17889.500       30.21         AVG              16.34      46.55            54.00       7.45




                                                                                            Page 18 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190117002-00A




Condition:         FCC Part 15 Class B                        Polarization:           Horizontal
EUT:               OSMO ACTION                                Power:                  AC 120V/60Hz
Model:             AC001                                      Distance:               3m
Test Mode:         Downloading




   Frequency      Reading       Detector      Corrected     Result        Limit          Margin
   (MHz)          (dBμV)                      (dB/m)        (dBμV/m)      (dBμV/m)       (dB)
     26482.966       40.36         peak             21.76      62.12          74.00        11.88
     26482.966       25.19         AVG              21.76      46.95          54.00        7.05




                                                                                           Page 19 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190117002-00A




Condition:         FCC Part 15 Class B                        Polarization:           Vertical
EUT:               OSMO ACTION                                Power:                  AC 120V/60Hz
Model:             AC001                                      Distance:               3m
Test Mode:         Downloading




   Frequency      Reading       Detector      Corrected     Result        Limit         Margin
   (MHz)          (dBμV)                      (dB/m)        (dBμV/m)      (dBμV/m)      (dB)
     26431.864       40.40         peak             21.54      61.94          74.00        12.06
     26431.864       26.41         AVG              21.54      47.95          54.00        6.05




                                                                                           Page 20 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190117002-00A



Condition:         FCC Part 15 Class B                         Polarization:           Horizontal
EUT:               OSMO ACTION                                 Power:                  AC 120V/60Hz
Model:             AC001                                       Distance:               1m
Test Mode:         Downloading




   Frequency      Reading       Detector      Corrected     Result        Limit          Margin
   (MHz)          (dBμV)                      (dB/m)        (dBμV/m)      (dBμV/m)       (dB)
     29880.762       45.12         peak             15.87      60.99           74.00        13.01
     29880.762       31.52         AVG              15.87      47.39           54.00        6.61




                                                                                           Page 21 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190117002-00A




Condition:         FCC Part 15 Class B                         Polarization:           Vertical
EUT:               OSMO ACTION                                 Power:                  AC 120V/60Hz
Model:             AC001                                       Distance:               1m
Test Mode:         Downloading




   Frequency      Reading       Detector      Corrected     Result        Limit          Margin
   (MHz)          (dBμV)                      (dB/m)        (dBμV/m)      (dBμV/m)       (dB)
     29950.902       44.55         peak             16.37      60.92           74.00        13.08
     29950.902       30.21         AVG              16.37      46.58           54.00        7.42


                                  *****END OF REPORT*****




                                                                                           Page 22 of 22



Document Created: 2019-05-15 18:00:44
Document Modified: 2019-05-15 18:00:44

© 2024 FCC.report