18_IP99 RFExp r1

FCC ID: 2ANBQ-IP99

RF Exposure Info

Download: PDF
FCCID_4312071

                      EXPOSURE
                      REPORT

                      FCC ID: 2ANBQ-IP99


                      Date of issue: June 10, 2019

Report Number:        MTi190423E155


Sample Description:   Q. POWER PRO


Model(s):             IP99


Applicant:            Momax Technology (Shenzhen) Limited


Address:              No.709, Floor 7, Vanke Fuchun Eastern Mansion Shennan
                      Road 7006, Futian District, Shenzhen, China


Date of Test:         Feb. 21, 2019 – June 10, 2019




                      Shenzhen Microtest Co., Ltd.
                         http://www.mtitest.com


                                      Table of Contents


  Applicant’s name:           Momax Technology (Shenzhen) Limited

                              No.709, Floor 7, Vanke Fuchun Eastern Mansion Shennan Road
  Address:
                              7006, Futian District, Shenzhen, China

  Manufacture's name:         iMX Electronic (Shenzhen) Co., LTD

                              F/4 East Side Mech. Factory, EVOC Tech. Industrial. Park, No.11
  Address:                    Gaoxin Rd., Gaoxin Area, Guangming New Area, Shenzhen City,
                              Guangdong, PRC.

  Product name:               Q. POWER PRO

  Trademark:                  MOMAX


  Model name:                 IP99


  Standard:                   FCC CFR 47 PART 1 , 1.1310


  RF Exposure Procedures:     KDB 680106 D01 RF Exposure Wireless Charging App v03



This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results
show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable
only to the tested sample identified in the report.




                Tested by:


                                                Jone Lee                   June 10, 2019


               Reviewed by:


                                                Blue Zheng                 June 10, 2019

              Approved by:

                                                Smith Chen                 June 10, 2019


1 General Information
1.1 Description of EUT

    Product name:                Q. POWER PRO

    Brand name:                  MOMAX

    Model name:                  IP99

    Series model:                N/A

    Deference in serial model:   N/A

    Operation frequency:         115–205 kHz

    Operational mode:            Wireless charging

    Modulation type:             Load modulation

    Antenna type:                Coil antenna

    Power source:                DC 5V from adapter or DC 3.8V by battery

    Battery:                     3.8V 8000mAh

    Adapter information:         N/A


1.2 Ancillary equipment list

          Equipment                Model                    S/N             Manufacturer

           Adapter                HA832                         /              ZIMI

               Load                     /                       /                /


1.3 Measurement uncertainty
Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y)

     Radiated emission(150kHz~30MHz)                 ± 2.5 dB
     Radiated emission(30MHz~1GHz)                   ± 4.2 dB
     Radiated emission (above 1GHz)                  ± 4.3 dB
     Temperature                                     ±1 degree
     Humidity                                        ±5%


2 Testing site
   Test Site               Shenzhen Microtest Co., Ltd

                           No.102A & 302A, East Block, Hengfang Industrial Park, Xingye
   Test Site Location
                           Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China

   FCC Registration No.:   448573


3 List of test equipment
 Equipment   Equipment                                 Serial   Calibration
                             Manufacturer     Model                           Due date
 No.         Name                                      No.      date

                             Narda Safety
             Broadband                        NBM-
 MTI-E068                    Test Solutions            D-1699   2018/07/13    2019/07/12
             Field Meter                      520
                             GmbH

                             Narda Safety
 MTI-E069    Probe E-Field                    EF0691   H-0571   2018/07/13    2019/07/12
                             Test Solutions


4 Test Results
4.4 Maximum permissible exposure
4.4.1        Limit


   Frequency          Electric field        Magnetic field            Power             Averaging
   range(MHz)         strength(V/m)         strength(A/m)        density(mW/cm2)      time(minutes)

                           (A) Limits for Occupational/Controlled Exposure
       0.3-3.0              614                 1.63                 *100                    6
       3.0-30             1842/f               4.89/f               *900/f2                  6
       30-300              61.4                0.163                 1.0 6                   6
     300-1500                                                        f/300                   6
   1500-100000                                                          5                    6
                       (B) Limits for General Population/Uncontrolled Exposure
      0.3-1.34              614                 1.63                 *100                   30
      1.34-30              824/f               2.19/f               *180/f2                 30
       30-300              27.5                0.073                  0.2                   30
     300-1500                                                       f/1500                  30
   1500-100000                                                          1                   30
f = frequency in MHz * = Plane-wave equivalent power density

4.4.2        Test Procedures
E and H-field measurements should be made with the center of the probe at a distance of 15 cm
surrounding the device and 20 cm above the top surface of the primary/client pair.

These measurements should be repeated for three different client battery levels, 1%, 50%, and 99%.

Record the test results.

KDB 680106 D01 RF Exposure Wireless Charging App v03:

(1) Power transfer frequency is less than 1MHz.

(2) Output power from each primary coil is less than or equal to 15 watts.

(3) The transfer system includes only single primary and secondary coils. This includes charging
systems that may have multiple primary coils and clients that are able to detect and allow coupling
only between individual pairs of coils.

(4) Client device is placed directly in contact with the transmitter.

(5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).

(6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top
surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE
limit.

Note: The device is in compliance with KDB 680106 D01 RF Exposure Wireless Charging App v03 6
conditions.


4.4.3   Test Setup


                                              Top Side


                                                            Back Side




                     Left Side
                                                                   15cm
                                                                 Right Side
                                                                              Field Probe


                                 Front Side

                                              Bottom Side


4.4.4   Test Result

                              Maximum permissible Exposure
          Battery                             Test
                        Test sides                      E –field(V/m)   H–field(A/m)
          levels                         distance(cm)
           <1%              Top                20          0.416           0.116
           <1%            Bottom               15          0.424           0.110
           <1%              Left               15          0.421           0.112
           <1%             Right               15          0.423           0.107
           <1%             Front               15          0.418           0.104
           <1%             Back                15          0.414           0.109
                           Limit                             614           1.63

                      Margin Limit (%)                    0.069%          7.12%



                              Maximum permissible Exposure
          Battery                             Test
                        Test sides                      E –field(V/m)   H–field(A/m)
          levels                         distance(cm)
          <50%              Top                20          0.423           0.120
          <50%            Bottom               15          0.409           0.116
          <50%              Left               15          0.413           0.113
          <50%             Right               15          0.414           0.109
          <50%             Front               15          0.416           0.112
          <50%             Back                15          0.411           0.107
                           Limit                             614           1.63

                      Margin Limit (%)                    0.069%          7.36%



                              Maximum permissible Exposure
          Battery                             Test
                        Test sides                      E –field(V/m)   H–field(A/m)
          levels                         distance(cm)
          <99%              Top                20          0.435           0.119
          <99%            Bottom               15          0.424           0.108
          <99%              Left               15          0.421           0.103
          <99%             Right               15          0.418           0.102
          <99%             Front               15          0.422           0.113
          <99%             Back                15          0.416           0.105
                           Limit                             614           1.63

                      Margin Limit (%)                    0.071%          7.30%


4.4.5   MPE Setup photo




                          ----END OF REPORT----



Document Created: 2019-06-10 18:28:05
Document Modified: 2019-06-10 18:28:05

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC