LCS190322010AEA-report-DSS

FCC ID: 2AN8NSKBZ04

Test Report

Download: PDF
FCCID_4246261

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA




                                                 FCC TEST REPORT
                                                               FOR
                                Shenzhen Hui Yu E-Commerce Co., Ltd.

                                               TRIPOD SELFIE STICK

                                                 Test Model: SKBZ04




  Prepared for                             :    Shenzhen Hui Yu E-Commerce Co., Ltd.
  Address                                  :    No.150-3 Hao 209, Jinyun Road, Buji Street, Longgang Distric,
                                                shenzhen, Guangdong, 518116, China

  Prepared by                              :    Shenzhen LCS Compliance Testing Laboratory Ltd.
  Address                                  :    1/F, Xingyuan Industrial Park, Gushu Community, Xixiang Street,
                                                Bao'an District, Shenzhen, Guangdong, China
  Tel                                      :    (+86)755-82591330
  Fax                                      :    (+86)755-82591332
  Web                                      :    www.LCS-cert.com
  Mail                                     :    webmaster@LCS-cert.com

  Date of receipt of test sample           :    March 26, 2019
  Number of tested samples                 :    1
  Serial number                            :    Prototype
  Date of Test                             :    March 26, 2019 ~ March 30, 2019
  Date of Report                           :    April 04, 2019




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 1 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


                                                     FCC TEST REPORT
                                            FCC CFR 47 PART 15 C(15.247)
Report Reference No. ................. : LCS190322010AEA

Date of Issue ................................... : April 04, 2019

Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd.

Address ........................................... : 1/F, Xingyuan Industrial Park, Gushu Community, Xixiang Street,
                                                 Bao'an District, Shenzhen, Guangdong, China
Testing Location/ Procedure........... : Full application of Harmonised standards ■
                                         Partial application of Harmonised standards □
                                         Other standard testing method □

Applicant’s Name .......................... : Shenzhen Hui Yu E-Commerce Co., Ltd.
Address ........................................... : No.150-3 Hao 209, Jinyun Road, Buji Street, Longgang Distric,
                                                      shenzhen, Guangdong, 518116, China
Test Specification
Standard.......................................... : FCC CFR 47 PART 15 C(15.247)

Test Report Form No. ..................... : LCSEMC-1.0

TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd.

Master TRF ..................................... : Dated 2011-03

Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.

Test Item Description. .................. : TRIPOD SELFIE STICK
Trade Mark ...................................... : humixx
Test Model ...................................... : SKBZ04
Ratings ............................................ : DC 3.7V by battery(65mAh)
Result ........................................... : Positive

            Compiled by:                                     Supervised by:                               Approved by:




 Peter Xiao / File administrators               Calvin Weng / Technique principal                    Gavin Liang/ Manager




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 2 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


                                                       FCC -- TEST REPORT

                                                                                                April 04, 2019
      Test Report No. :                LCS190322010AEA
                                                                                                Date of issue


   Test Model...........................           : SKBZ04

   EUT.........................................    : TRIPOD SELFIE STICK


   Applicant...............................        : Shenzhen Hui Yu E-Commerce Co., Ltd.
   Address..................................       : No.150-3 Hao 209, Jinyun Road, Buji Street, Longgang Distric,
                                                     shenzhen, Guangdong, 518116, China
   Telephone...............................        : /
   Fax..........................................   : /


   Manufacturer........................            : Shenzhen Hui Yu E-Commerce Co., Ltd.
   Address...................................      : No.150-3 Hao 209, Jinyun Road, Buji Street, Longgang Distric,
                                                     shenzhen, Guangdong, 518116, China
   Telephone...............................        : /
   Fax..........................................   : /



   Factory...................................      :   /
   Address...................................      :   /
   Telephone...............................        :   /
   Fax..........................................   :   /




                            Test Result                                                     Positive
  The test report merely corresponds to the test sample.
  It is not permitted to copy extracts of these test result without the written permission of the test
  laboratory.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 3 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


                                                        Revision History

          Revision                        Issue Date                          Revisions                        Revised By
            000                          April 04, 2019                      Initial Issue                     Gavin Liang




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 4 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                     FCC ID: 2AN8NSKBZ04                    Report No.: LCS190322010AEA



                                                          TABLE OF CONTENTS

    Description                                                                                                                                       Page
   1. GENERAL INFORMATION ........................................................................................................ 6
       1.1 Description of Device (EUT) .............................................................................................................. 6
       1.2 Support equipment List ...................................................................................................................... 6
       1.3 External I/O Cable ............................................................................................................................... 6
       1.4 Description of Test Facility................................................................................................................. 6
       1.5 Statement of the Measurement Uncertainty ................................................................................... 7
       1.6 Measurement Uncertainty .................................................................................................................. 7
       1.7 Description of Test Modes ................................................................................................................. 7
   2. TEST METHODOLOGY .............................................................................................................. 8
       2.1 EUT Configuration............................................................................................................................... 8
       2.2 EUT Exercise ....................................................................................................................................... 8
       2.3 General Test Procedures ................................................................................................................... 8
   3. SYSTEM TEST CONFIGURATION .......................................................................................... 9
       3.1 Justification........................................................................................................................................... 9
       3.2 EUT Exercise Software ...................................................................................................................... 9
       3.3 Special Accessories ............................................................................................................................ 9
       3.4 Block Diagram/Schematics ................................................................................................................ 9
       3.5 Equipment Modifications .................................................................................................................... 9
       3.6 Test Setup ............................................................................................................................................ 9
   4. SUMMARY OF TEST RESULTS............................................................................................. 10
   5. SUMMARY OF TEST EQUIPMENT ....................................................................................... 11
   6. MEASUREMENT RESULTS .................................................................................................... 12
       6.1 Peak Power ........................................................................................................................................ 12
       6.2 Frequency Separation and 20 dB Bandwidth ............................................................................... 13
       6.3 Number of Hopping Frequency ....................................................................................................... 14
       6.4 Time of Occupancy (Dwell Time) ................................................................................................... 15
       6.5 Conducted Spurious Emissions and Band Edges Test .............................................................. 16
       6.6 Restricted Band Emission Limit ...................................................................................................... 17
       6.7. AC Power line conducted emissions ............................................................................................. 26
       6.8. Band-edge measurements for radiated emissions ..................................................................... 28
       6.9. Pseudorandom frequency hopping sequence ............................................................................. 30
       6.10. Antenna requirement ..................................................................................................................... 31
   7. TEST SETUP PHOTOGRAPHS .............................................................................................. 33
   8. EXTERIOR PHOTOGRAPHS OF THE EUT ......................................................................... 33
   9. INTERIOR PHOTOGRAPHS OF THE EUT .......................................................................... 33




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 5 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


1. GENERAL INFORMATION
  1.1 Description of Device (EUT)

    EUT                                     : TRIPOD SELFIE STICK
    Test Model                              : SKBZ04

    Power Supply                            : DC 3.7V by battery(65mAh)

    Hardware version                        : V1.0
    Software version                        : V1.0
    BluetoothOperation frequency : 2402MHz-2480MHz
    Bluetooth Version                       : V3.0
    Bluetooth Channel Number                : 79 Channels for Bluetooth V3.0(BT Classics)
    Bluetooth Channel Spacing               : 1MHz for Bluetooth V3.0 (BT Classics)
    Bluetooth Modulation Type               : GFSK, π/4-DQPSK for Bluetooth V3.0 (BT Classics)
    Antenna Description                     : PCB Antenna,2.3dBi(Max.)


  1.2 Support equipment List

             Manufacturer                Description                   Model             Serial Number         Certificate
                    --                         --                        --                      --                 --

  1.3 External I/O Cable

             I/O Port Description                           Quantity                                  Cable
                    DC IN Port                                    1                                     N/A


  1.4 Description of Test Facility
    FCC Registration Number. is 254912.
    Industry Canada Registration Number. is 9642A-1.
    ESMD Registration Number. is ARCB0108.
    UL Registration Number. is 100571-492.
    TUV SUD Registration Number. is SCN1081.
    TUV RH Registration Number. is UA 50296516-001
    NVLAP Registration Code is 600167-0


    The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.10:2013 and
    CISPR 16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 6 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


  1.5 Statement of the Measurement Uncertainty
    The data and results referenced in this document are true and accurate. The reader is cautioned that
    there may be errors within the calibration limits of the equipment and facilities. The measurement
    uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
    “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4:
    Uncertainty in EMC Measurements” and is documented in the LCS quality system acc. To DIN EN
    ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may
    result in additional deviation. The manufacturer has the sole responsibility of continued compliance of
    the device.

  1.6 Measurement Uncertainty
                    Test Item                       Frequency Range                      Uncertainty               Note
                                                      9KHz~30MHz                          3.10dB                    (1)
                                                    30MHz~200MHz                          2.96dB                    (1)
            Radiation Uncertainty           :      200MHz~1000MHz                         3.10dB                    (1)
                                                     1GHz~26.5GHz                         3.80dB                    (1)
                                                    26.5GHz~40GHz                         3.90dB                    (1)
           Conduction Uncertainty :                  150kHz~30MHz                         1.63dB                    (1)
             Power disturbance    :                 30MHz~300MHz                          1.60dB                    (1)
    (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95%
    confidence level using a coverage factor of k=2.

  1.7 Description of Test Modes
    Bluetooth operates in the unlicensed ISM Band at 2.4GHz. With basic data rate feature, the data rates
    can be up to 1 Mb/s by modulating the RF carrier using GFSK techniques. The EUT works in the X-axis,
    Y-axis, Z-axis. The following operating modes were applied for the related test items. All test modes
    were tested, only the result of the worst case was recorded in the report.

                                                        Frequency Range                        Data Rate
                     Mode of Operations
                                                             (MHz)                              (Mbps)
                                                              2402                                1/2
                            BT V 3.0                          2441                                1/2
                                                              2480                                1/2
                                                   For Conducted Emission
                                   Test Mode                                          TX Mode
                                                    For Radiated Emission
                                   Test Mode                                          TX Mode


    Worst-case mode and channel used for 150 kHz-30 MHz power line conducted emissions was the
    mode and channel with the highest output power that was determined to be TX (1Mbps).
    Worst-case mode and channel used for 9kHz-1000 MHz radiated emissions was the mode and
    channel with the highest output power, that was determined to be TX(1Mbps-MCH).
    Pre-test AC conducted emission at charge from PC mode, recorded worst case.
    Pre-test AC conducted emission at both voltage AC 120V/60Hz and AC 240V/50Hz, recorded worst
    case.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 7 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


2. TEST METHODOLOGY
    The tests documented in this report were performed in accordance with ANSI C63.10-2013, FCC CFR
    PART 15C 15.207, 15.209, 15.247 and DA 00-705.

  2.1 EUT Configuration
    The EUT configuration for testing is installed on RF field strength measurement to meet the
    Commissions requirement and operating in a manner that intends to maximize its emission
    characteristics in a continuous normal application.

  2.2 EUT Exercise
    The EUT was operated in the normal operating mode for Hopping Numbers and Dwell
    Time test and a continuous transmits mode for other tests.
    According to its specifications, the EUT must comply with the requirements of the Section 15.207,
    15.209, 15.247 under the FCC Rules Part 15 Subpart C.

  2.3 General Test Procedures
  2.3.1 Conducted Emissions

    The EUT is placed on the turntable, which is 0.8 m above ground plane.. According to the requirements
    in Section 6.2.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the frequency
    range between 0.15 MHz and 30MHz using Quasi-peak and average detector modes.

  2.3.2 Radiated Emissions

    The EUT is placed on the turntable, which is 0.8 m above ground plane.The turntable shall rotate 360
    degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving
    antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to
    be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to
    find out the maximum emissions, exploratory radiated emission measurements were made according
    to the requirements in Section 6.3 of ANSI C63.10-2013




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 8 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


3. SYSTEM TEST CONFIGURATION
  3.1 Justification
    The system was configured for testing in a continuous transmits condition.

  3.2 EUT Exercise Software
    The system was configured for testing in a continuous transmits condition and change test channels by
    software (FCCAssist 2.4) provided by applicant.

  3.3 Special Accessories
                                                                                         Serial
             Manufacturer                Description                 Model                                  Certificate
                                                                                        Number
                 Lenovo                       PC                     B470                  --                 SDOC
                 Lenovo             AC/DC ADAPTER               ADP-90DDB                   --                SDOC

  3.4 Block Diagram/Schematics
    Please refer to the related document.

  3.5 Equipment Modifications
    Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

  3.6 Test Setup
    Please refer to the test setup photo.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 9 of 33


 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


4. SUMMARY OF TEST RESULTS

                                    Applied Standard: FCC Part 15 Subpart C
      FCC Rules                   Description of Test       Test Sample                            Result              Remark
                              Maximum Conducted Output
    §15.247(b)(1)                                             Sample 1                           Compliant          Appendix A.1
                                        Power
     §15.247(c)                  Frequency Separation         Sample 1                           Compliant          Appendix A.3
     §15.247(c)                99% and 20dB Bandwidth         Sample 1                           Compliant          Appendix A.2
   §15.247(a)(1)(ii)         Number Of Hopping Frequency      Sample 2                           Compliant          Appendix A.4
                                  Time Of Occupancy
   §15.247(a)(1)(iii)                                         Sample 2                           Compliant          Appendix A.5
                                     (Dwell Time)
      §15.209,
                              Radiated Spurious Emissions                    Sample 1            Compliant               Note 1
     §15.247(d)
      §15.209,                                                                                                      Appendix A.6
                             Conducted Spurious Emissions                    Sample 1            Compliant
     §15.247(d)                                                                                                     Appendix A.7
      §15.205                 Emissions at Restricted Band                   Sample 1            Compliant          Appendix A.8
     §15.207(a)              AC Mains Conducted Emissions                    Sample 1            Compliant             Note 1
       §15.203                  Antenna Requirements                         Sample 1            Compliant             Note 1
  §15.247(i)§2.1093                  RF Exposure                               N/A               Compliant             Note 2


Remark:
Note 1 --- Test results inside test report.
Note 2 --- Test results in other test report (RF Exposure Evaluation).




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 10 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AN8NSKBZ04             Report No.: LCS190322010AEA

5. SUMMARY OF TEST equipment
Item                Equipment                   Manufacturer          Model No.              Serial No.          Cal Date       Due Date
 1                 Power Meter                       R&S                 NRVS                 100444           2018-06-16      2019-06-15
 2                 Power Sensor                      R&S               NRV-Z81                100458           2018-06-16      2019-06-15
 3                 Power Sensor                      R&S               NRV-Z32                10057            2018-06-16      2019-06-15
 4                 Test Software                  Tonscend             JS1120-2                N/A                 N/A             N/A
 5                RF Control Unit                 Tonscend             JS0806-2                N/A             2018-06-16      2019-06-15
 6              MXA Signal Analyzer                 Agilent             N9020A             MY50510140          2018-06-16      2019-06-15
 7               DC Power Supply                    Agilent             E3642A                 N/A             2018-11-15      2019-11-14
 8               EMI Test Software                  AUDIX                  E3                  N/A             2018-06-16      2019-06-15
 9          3m Semi Anechoic Chamber           SIDT FRANKONIA           SAC-3M              03CH03-HY          2018-06-16      2019-06-15
 10            Positioning Controller                 MF               MF-7082                 N/A             2018-06-16      2019-06-15
 11            Active Loop Antenna              SCHWARZBECK          FMZB 1519B               00005            2018-07-26      2019-07-25
 12               By-log Antenna                SCHWARZBECK            VULB9163              9163-470          2018-07-26      2019-07-25
 13                Horn Antenna                 SCHWARZBECK          BBHA 9120D            9120D-1925          2018-07-02      2019-07-01
 14          Broadband Horn Antenna             SCHWARZBECK           BBHA 9170                 791            2018-09-20      2019-09-19
 15           Broadband Preamplifier            SCHWARZBECK            BBV 9719              9719-025          2018-09-20      2019-09-19
 16              EMI Test Receiver                   R&S                 ESR 7                101181           2018-06-16      2019-06-15
 17          RS SPECTRUM ANALYZER                    R&S                 FSP40                100503           2018-11-15      2019-11-14
 18                 AMPLIFIER                      QuieTek                QTK             CHM/0809065          2018-11-15      2019-11-14
 19               RF Cable-R03m                    Jye Bao              RG142                 CB021            2018-06-16      2019-06-15
 20                RF Cable-HIGH                   SUHNER           SUCOFLEX 106            03CH03-HY          2018-06-16      2019-06-15
 21               6dB Attenuator                       /              100W/6dB               1172040           2018-06-16      2019-06-15
 22               3dB Attenuator                       /                2N-3dB                   /             2018-06-16      2019-06-15
 23              EMI Test Receiver                   R&S                  ESPI                101840           2018-06-16      2019-06-15
 24               Artificial Mains                   R&S                ENV216                101288           2018-06-16      2019-06-15
 25              10dB Attenuator                SCHWARZBECK          MTS-IMP-136        261115-001-0032        2018-06-16      2019-06-15
Note: All equipment is calibrated through GUANGZHOU LISAI CALIBRATION AND TEST CO.,LTD.




     This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 11 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


6. MEASUREMENT RESULTS
  6.1 Peak Power
  6.1.1 Block Diagram of Test Setup




  6.1.2 Limit

    According to §15.247(b)(1), For frequency hopping systems operating in the 2400–2483.5 MHz band
    employing at least 75 non-overlapping hopping channels, and all frequency hopping systems in the
    5725–5850 MHz band: 1 watt. For all other frequency hopping systems in the 2400–2483.5 MHz band:
    0.125 watts.

  6.1.3 Test Procedure
   The transmitter output is connected to the spectrum.

  6.1.4. Test Procedures
  1) Span: Approximately five times the 20 dB bandwidth, centered on a hopping channel.
  2) RBW > 20 dB bandwidth of the emission being measured.
  3) VBW ≥ RBW.
  4) Sweep: Auto.
  5) Detector function: Peak.
  6) Trace: Max hold.


  6.1.5 Test Results
       Please See appendix A for A.1test data.


    Remark:
    1) Test results including cable loss;
    2) Measured output power at difference Packet Type for each mode and recorded worst case for each
    mode.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 12 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA

  6.2 Frequency Separation and 20 dB Bandwidth

  6.2.1 Limit

    According to §15.247(a) (1), Frequency hopping systems shall have hopping channel carrier
    frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping channel,
    whichever is greater. Alternatively, frequency hopping systems operating in the 2400-2483.5 MHz band
    may have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB
    bandwidth of the hopping channel, whichever is greater, provided the systems operate with an output
    power no greater than 125 mW.

  6.2.2 Block Diagram of Test Setup




  6.2.3 Test Procedure

    Frequency separation test procedure:
    1). Place the EUT on the table and set it in transmitting mode.
    2). Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to
    the Spectrum Analyzer.
    3). Set center frequency of Spectrum Analyzer = middle of hopping channel.
    4). Set the Spectrum Analyzer as RBW = 100 kHz, VBW = 300 kHz, Span = wide enough to capture
    the peaks of two adjacent channels, Sweep = auto.
    5). Max hold, mark 2 peaks of hopping channel and record the 2 peaks frequency.

    20dB bandwidth test procedure:
    1). Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel.
    2). RBW ≥1% of the 20 dB bandwidth, VBW ≥RBW.
    3). Detector function = peak.
    4). Trace = max hold.

  6.2.4 Test Results
      Please See appendix A for A.2 test data.
     Please See appendix A for A.3 test data.

     Remark:
     1) Test results including cable loss;
     2) Measured at difference Packet Type for each mode and recorded worst case for each mode.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 13 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


  6.3 Number of Hopping Frequency

  6.3.1 Limit

    According to §15.247(a)(1)(ii) or A8.1 (d), Frequency hopping systems operating in the band
    2400-2483.5 MHz shall use at least 15 hopping channels.

  6.3.2 Block Diagram of Test Setup




  6.3.3 Test Procedure

    1). Place the EUT on the table and set it in transmitting mode.
    2). Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to
    the Spectrum Analyzer.
    3). Set Spectrum Analyzer Start=2400MHz, Stop = 2483.5MHz, Sweep = auto.
    4). Set the Spectrum Analyzer as RBW, VBW=1MHz.
    5). Max hold, view and count how many channel in the band.

  6.3.4 Test Results

    Please See appendix A for A.4 test data.
    Remark:
    1) Test results including cable loss;
    2) Measured number of hopping channels at difference Packet Type for each mode and recorded worst
    case for each mode.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 14 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


  6.4 Time of Occupancy (Dwell Time)

  6.4.1 Limit

    According to §15.247(a)(1)(iii) or A8.1 (d), Frequency hopping systems operating in the 2400MHz-
    2483.5 MHz bands. The average time of occupancy on any channels shall not greater than 0.4 s within
    a period 0.4 s multiplied by the number of hopping channels employed.

  6.4.2 Block Diagram of Test Setup




  6.4.3 Test Procedure

    1). Place the EUT on the table and set it in transmitting mode.
    2). Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to
    the Spectrum Analyzer.
    3). Set center frequency of Spectrum Analyzer = operating frequency.
    4). Set the Spectrum Analyzer as RBW=1MHz, VBW=3MHz, Span = 0Hz, Sweep = auto.
    5). Repeat above procedures until all frequency measured was complete.

  6.4.4 Test Results


  Please See appendix A for A.5 test data
  The Dwell Time=Burst Width*Total Hops. The detailed calculations are showed as follows:
  The duration for dwell time calculation: 0.4[s]*hopping number=0.4[s]*79[ch]=31.6[s*ch];
  The burst width [ms/hop/ch], which is directly measured, refers to the duration on one channel hop.
  The hops per second for all channels: The selected EUT Conf uses a slot type of 5-Tx&1-Rx and a
  hopping rate of 1600 [ch*hop/s] for all channels. So the final hopping rate for all channels is
  1600/6=266.67 [ch*hop/s]
  The hops per second on one channel: 266.67 [ch*hops/s]/79 [ch]=3.38 [hop/s];
  The total hops for all channels within the dwell time calculation duration: 3.38 [hop/s]*31.6[s*ch]=106.67
  [hop*ch];
  The dwell time for all channels hopping: 106.67 [hop*ch]*Burst Width [ms/hop/ch].

   Remark:
  1)Test results including cable loss;
  2)Measured at difference Packet Type for each mode and recorded woest case for each mode.
  3)Dwell Time Calculate formula:
    DH5: Dwell time=Pulse Time (ms) × (1600 ÷ 6 ÷ 79) ×31.6 Second
  4)Measured at low, middle and high channel, recorded worst at middle channel;




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 15 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


  6.5 Conducted Spurious Emissions and Band Edges Test
  6.5.1 Limit

    In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally
    modulated intentional radiator is operating, the radio frequency power that is produced by the
    intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that
    contains the highest level of the desired power, based on either an RF conducted or a radiated
    measurement. Attenuation below the general limits specified in Section 15.209(a) is not required.

  6.5.2 Block Diagram of Test Setup




  6.5.3 Test Procedure

    Conducted RF measurements of the transmitter output were made to confirm that the EUT antenna
    port conducted emissions meet the specified limit and to identify any spurious signals that require
    further investigation or measurements on the radiated emissions site.
    The transmitter output is connected to the spectrum analyzer. The resolution bandwidth is set to 100
    KHz. The video bandwidth is set to 300 KHz.
    Measurements are made over the 30 MHz to 25GHz range with the transmitter set to the lowest,
    middle, and highest channels

  6.5.4 Test Results of Conducted Spurious Emissions

    Please See appendix A for A.6 test data.

    Please See appendix A for A.7 test data.


    Remark:
    1) Test results including cable loss;
    2) Measured at difference Packet Type for each mode and recorded worst case for each mode.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 16 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA

  6.6 Restricted Band Emission Limit
    6.6.1. Standard Applicable
    15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in
    any of the frequency bands listed below:

             MHz                                           MHz                             MHz                           GHz
          0.090-0.110                 16.42-16.423                   399.9-410                     4.5-5.15
          \1\ 0.495-0.505             16.69475-16.69525              608-614                       5.35-5.46
          2.1735-2.1905               16.80425-16.80475              960-1240                      7.25-7.75
          4.125-4.128                 25.5-25.67                     1300-1427                     8.025-8.5
          4.17725-4.17775             37.5-38.25                     1435-1626.5                   9.0-9.2
          4.20725-4.20775             73-74.6                        1645.5-1646.5                 9.3-9.5
          6.215-6.218                 74.8-75.2                      1660-1710                     10.6-12.7
          6.26775-6.26825             108-121.94                     1718.8-1722.2                 13.25-13.4
          6.31175-6.31225             123-138                        2200-2300                     14.47-14.5
          8.291-8.294                 149.9-150.05                   2310-2390                     15.35-16.2
          8.362-8.366                 156.52475-156.52525            2483.5-2500                   17.7-21.4
          8.37625-8.38675             156.7-156.9                    2690-2900                     22.01-23.12
          8.41425-8.41475             162.0125-167.17                3260-3267                     23.6-24.0
          12.29-12.293.               167.72-173.2                   3332-3339                     31.2-31.8
          12.51975-12.52025           240-285                        3345.8-3358                   36.43-36.5
          12.57675-12.57725           322-335.4                      3600-4400                     (\2\)
          13.36-13.41
    \1\ Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
    \2\ Above 38.6
    According to §15.247 (d): 20dBc in any 100 kHz bandwidth outside the operating frequency band. In
    case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the
    table below has to be followed.
             Frequencies                         Field Strength               Measurement Distance
                 (MHz)                         (microvolts/meter)                    (meters)
             0.009~0.490                          2400/F(KHz)                           300
             0.490~1.705                         24000/F(KHz)                           30
              1.705~30.0                               30                               30
                 30~88                                100                                3
                88~216                                150                                3
               216~960                                200                                3
              Above 960                               500                                3

    6.6.2. Measuring Instruments and Setting
    Please refer to section 6 of equipment list in this report. The following table is the setting of spectrum
    analyzer and receiver.
    Spectrum Parameter                             Setting
    Attenuation                                    Auto
    Start Frequency                                1000 MHz
    Stop Frequency                                 10th carrier harmonic
    RB / VB (Emission in restricted band)          1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average
    RB / VB (Emission in non-restricted band) 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 17 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


   Receiver Parameter                                           Setting
   Attenuation                                                  Auto
   Start ~ Stop Frequency                                       9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG
   Start ~ Stop Frequency                                       150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG
   Start ~ Stop Frequency                                       30MHz~1000MHz / RB/VB 120kHz/1MHz for QP

 6.6.3. Test Procedures
    1) Sequence of testing 9 kHz to 30 MHz


    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or
    described by manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna height is 0.8 meter.
    --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
    emissions

    Final measurement:
    --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
    position (0°to 360°) and by rotating the elevation axes (0°to 360°).
    --- The final measurement will be done in the position (turntable and elevation) causing the highest
    emissions with QPK detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin
    to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will
    be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 18 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


    2) Sequence of testing 30 MHz to 1 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or
    described by manufacturer.
    --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground
    plane.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height changes from 1 to 3 meter.
    --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak
    to find the maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software
    maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4
    meter.
    --- The final measurement will be done with QP detector with an EMI receiver.
    --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization,
    turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the
    graph of the premeasurement with marked maximum final measurements and the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 19 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


    3) Sequence of testing 1 GHz to 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or
    described by manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height scan range is 1 meter to 2.5 meter.
    --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find
    the maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software
    maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4
    meter. This procedure is repeated for both antenna polarizations.
    --- The final measurement will be done in the position (turntable, EUT-table and antenna polarization)
    causing the highest emissions with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position,
    antenna polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the
    graph of the premeasurement with marked maximum final measurements and the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 20 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


    4) Sequence of testing above 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or
    described by manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 1 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The antenna is moved spherical over the EUT in different polarizations of the antenna.

    Final measurement:
    --- The final measurement will be performed at the position and antenna orientation for all detected
    emissions that were found during the premeasurements with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and limit
    will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 21 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


  6.6.4. Test Setup Layout




    Above 10 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20
    dB/decade form 3m to 1.5m.
    Distance extrapolation factor = 20 log (specific distanc [3m] / test distance [1.5m]) (dB);
    Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB].




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 22 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


   6.6.5. EUT Operation during Test
    The EUT was programmed to be in continuously transmitting mode.

   6.6.6. Results of Radiated Emissions (9 kHz~30MHz)

            Temperature                          23.1℃                       Humidity                        53.8%
            Test Engineer                     Diamond Lu                   Configurations                     BT

               Freq.                   Level                Over Limit               Over Limit
                                                                                                               Remark
              (MHz)                   (dBuV)                  (dB)                    (dBuV)
                 -                        -                       -                        -                  See Note

    Note:
    The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible
    value has no need to be reported.
    Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
    Limit line = specific limits (dBuV) + distance extrapolation factor.


    PASS.
    Only record the worst test result in this report.
    The test data please refer to following page.

Below 1GHz (Worst case: GFSK, Low Channel)
     Vertical




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 23 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


    Horizontal




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 24 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


Above 1GHz

Note: All the modes have been tested and recorded worst mode in the report.


The worst test result for GFSK, Channel 0 / 2402 MHz
                               Ant.         Pre.       Cab.
  Freq.        Reading                                            Measured         Limit        Margin
                               Fac         Fac.        Loss                                                 Remark             Pol.
  MHz           dBuV                                               dBuV/m         dBuV/m         dB
                              dB/m          dB          dB
 4804.00         47.81        33.06        35.04       3.94         49.77           74.00       -24.23       Peak          Horizontal
 4804.00         31.15        33.06        35.04       3.94         33.11           54.00       -20.89      Average        Horizontal
 4804.00         48.22        33.06        35.04       3.94         50.18           74.00       -23.82       Peak           Vertical
 4804.00         33.60        33.06        35.04       3.94         35.56           54.00       -18.44      Average         Vertical
     The worst test result for GFSK, Channel 39 / 2441 MHz
                                Ant.        Pre.       Cab.
   Freq.       Reading                                            Measured         Limit        Margin
                                Fac         Fac.       Loss                                                  Remark            Pol.
   MHz          dBuV                                               dBuV/m         dBuV/m         dB
                               dB/m          dB         dB
 4882.00         47.95         33.16       35.15       3.96          49.92          74.00       -24.08       Peak          Horizontal
 4882.00         33.72         33.16       35.15       3.96          35.69          54.00       -18.31      Average        Horizontal
 4882.00         50.51         33.16       35.15       3.96          52.48          74.00       -21.52       Peak           Vertical
 4882.00         35.74         33.16       35.15       3.96          37.71          54.00       -16.29      Average         Vertical
     The worst test result for GFSK, Channel 78 / 2480 MHz
                                Ant.        Pre.        Cab.
  Freq.        Reading                                            Measured         Limit        Margin
                                Fac        Fac.         Loss                                                 Remark            Pol.
  MHz           dBuV                                               dBuV/m         dBuV/m         dB
                               dB/m         dB           dB
 4960.00         49.49         33.26       35.14        3.98         51.59          74.00        -22.41       Peak         Horizontal
 4960.00         33.18         33.26       35.14        3.98         35.28          54.00        -18.72      Average       Horizontal
 4960.00         49.91         33.26       35.14        3.98         52.01          74.00        -21.99       Peak          Vertical
 4960.00         35.48         33.26       35.14        3.98         37.58          54.00        -16.42      Average        Vertical


     Notes:
     1). Measuring frequencies from 9 KHz - 10th harmonic (ex. 26GHz), No emission found between lowest
     internal used/generated frequency to 30 MHz.
     2). Radiated emissions measured in frequency range from 9 KHz - 10th harmonic (ex. 26GHz) were
     made with an instrument using Peak detector mode.
     3). 18~25GHz at least have 20dB margin. No recording in the test report.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 25 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


  6.7. AC Power line conducted emissions
  6.7.1 Standard Applicable

    According to §15.207 (a): For an intentional radiator which is designed to be connected to the public
    utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on
    any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The
    limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The
    limits at specific frequency range is listed as follows:

         Frequency Range                                                       Limits (dBμV)
               (MHz)                                      Quasi-peak                                      Average
            0.15 to 0.50                                   66 to 56                                       56 to 46
              0.50 to 5                                      56                                             46
               5 to 30                                       60                                             50

              * Decreasing linearly with the logarithm of the frequency

  6.7.2 Block Diagram of Test Setup




  6.7.3 Test Results

   PASS.
   The test data please refer to following page.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 26 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


AC Conducted Emission of charge from PC mode @ AC 120V/60Hz @ GFSK (worst case)

Line




Neutral




***Note: Pre-scan all modes and recorded the worst case results in this report (GFSK).

   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 27 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA




   6.8. Band-edge measurements for radiated emissions

   6.8.1 Standard Applicable
   In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally
   modulated intentional radiator is operating, the radio frequency power that is produced by the intentional
   radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the
   highest level of the desired power, based on either an RF conducted or a radiated measurement,
   provided the transmitter demonstrates compliance with the peak conducted power limits. If the
   transmitter complies with the conducted power limits based on the use of RMS averaging over a time
   interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this
   paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a)
   is not required. In addition, radiated emissions which fall in the restricted bands, as defined in
   §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).

   6.8.2. Test Setup Layout




   6.8.3. Measuring Instruments and Setting
   Please refer to section 6 of equipment list in this report. The following table is the setting of Spectrum
   Analyzer.

   6.8.4. Test Procedures
    According to KDB 412172 D01 section 1.1 Field Strength Approach (linear terms):
    eirp = pt x gt = (E x d)2/30
    Where:
    pt
    gt

     d = measurement distance in meters (m).
     erp = eirp/1.64 = (E x d)2/(30 x 1.64)
     Where all terms are as previously defined.

1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Remove the antenna from the EUT and then connect to a low loss RF cable from the antenna port to a
   EMI test receiver, then turn on the EUT and make it operate in transmitting mode. Then set it to Low
   Channel and High Channel within its operating range, and make sure the instrument is operated in its
   linear range.
3. Set both RBW and VBW of spectrum analyzer to 100 kHz with a convenient frequency span including
   100kHz bandwidth from band edge, for Radiated emissions restricted band RBW=1MHz, VBW=3MHz
   for peak detector and RBW=1MHz, VBW=1/B for Peak detector.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.
6. Measure the conducted output power (in dBm) using the detector specified by the appropriate regulatory
   agency for guidance regarding measurement procedures for determining quasi-peak, peak, and average
   conducted output power, respectively).
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 28 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA
7. Add the maximum transmit antenna gain (in dBi) to the measured output power level to determine the
    EIRP level (see 12.2.5 for guidance on determining the applicable antenna gain)
8. Add the appropriate maximum ground reflection factor to the EIRP level (6 dB for frequencies ≤ 30 MHz,
    4.7 dB for frequencies between 30 MHz and 1000 MHz, inclusive and 0 dB for frequencies > 1000 MHz).
9. For devices with multiple antenna-ports, measure the power of each individual chain and sum the EIRP
    of all chains in linear terms (e.g., Watts, mW).
10. Compare the resultant electric field strength level to the applicable regulatory limit.
11. Perform radiated spurious emission test duress until all measured frequencies were complete.

   6.8.5. Test Results

     Please See appendix A for A.8 test data.


     Remark:
     1) Measured at difference Packet Type for each mode and recorded worst case for each mode.
     2) Measured at Hopping and Non-Hopping mode, recorded worst at Non-Hopping mode.
     3) The other emission levels were very low against the limit.
     4) The average measurement was not performed when the peak measured data under the limit of
     average detection.
     5) Detector AV is setting spectrum/receiver. RBW=1MHz/VBW=330Hz/Sweep
     time=Auto/Detector=Peak.
     6) Since the out-of-band characteristics of the EUT transmit antenna will often be unknown, the use of
     a conservative antenna gain value is necessary. Thus, when determining the EIRP based on the
     measured conducted power, the upper bound on antenna gain for a device with a single RF output
     shall be selected as the maximum in-band gain of the antenna across all operating bands, or 2 dBi,
     whichever is greater. However, for devices that operate in multiple frequency bands while using the
     same transmit antenna, the highest gain of the antenna within the operating band nearest in frequency
     to the restricted band emission being measured may be used in lieu of the overall highest gain when
     the emission is at a frequency that is within 20 percent of the nearest band edge frequency, but in no
     case shall a value less than 2 dBi be used.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 29 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


   6.9. Pseudorandom frequency hopping sequence

   6.9.1 Standard Applicable
   For 47 CFR Part 15C sections 15.247 (a) (1) requirement:

   Frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of
   25 kHz or the 20 dB bandwidth of the hop-ping channel, whichever is greater. Alternatively, frequency
   hopping systems operating in the 2400–2483.5 MHz band may have hopping channel carrier
   frequencies that are separated by 25 kHz or two-thirds of the 20 dB bandwidth of the hopping channel,
   whichever is greater, provided the systems operate with an output power no greater than 125 mW. The
   system shall hop to channel frequencies that are selected at the system hopping rate from a pseudo
   randomly ordered list of hopping frequencies. Each frequency must be used equally on the average by
   each transmitter. The system receivers shall have input bandwidths that match the hop-ping channel
   bandwidths of their corresponding transmitters and shall shift frequencies in synchronization with the
   transmitted signals.

   6.9.2 EUT Pseudorandom Frequency Hopping Sequence Requirement

  The pseudorandom frequency hopping sequence may be generated in a nice-stage shift register whose
  5th first stage. The sequence begins with the first one of 9 consecutive ones, for example: the shift
  register is initialized with nine ones.
● Number of shift register stages:9
● Length of pseudo-random sequence:29-1=511 bits
● Longest sequence of zeros:8(non-inverted signal)




   An example of pseudorandom frequency hopping sequence as follows:




    Each frequency used equally one the average by each transmitter.
   The system receiver have input bandwidths that match the hopping channel bandwidths of their
   corresponding transmitter and shift frequencies in synchronization with the transmitted signals.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 30 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA


  6.10. Antenna requirement

    6.10.1 Standard Applicable
    According to antenna requirement of §15.203.
    An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
    responsible party shall be used with the device. The use of a permanently attached antenna or of an
    antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply
    with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can
    be re-placed by the user, but the use of a standard antenna jack or electrical connector is prohibited.
    This requirement does not apply to carrier current devices or to devices operated under the provisions
    of Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to
    intentional radiators that must be professionally installed, such as perimeter protection systems and
    some field disturbance sensors, or to other intentional radiators which, in accordance with Section
    15.31(d), must be measured at the installation site. However, the installer shall be responsible for
    ensuring that the proper antenna is employed so that the limits in this Part are not exceeded.

    And according to §15.247(4)(1), system operating in the 2400-2483.5MHz bands that are used
    exclusively for fixed, point-to-point operations may employ transmitting antennas with directional gain
    greater than 6dBi provided the maximum peak output power of the intentional radiator is reduced by 1
    dB for every 3 dB that the directional gain of the antenna exceeds 6dBi.

    6.10.2 Antenna Connected Construction
    6.10.2.1. Standard Applicable

    According to § 15.203 & RSS-Gen, an intentional radiator shall be designed to ensure that no antenna
    other than that furnished by the responsible party shall be used with the device.

    6.10.2.2. Antenna Connector Construction

    The gains of antenna used for transmitting is 2.3dBi, and the antenna is an PCB antenna connect to
    PCB board and no consideration of replacement. Please see EUT photo for details.

    6.10.2.3. Results: Compliance.

    Measurement
    The antenna gain of the complete system is calculated by the difference of radiated power in EIRP and
    the conducted power of the module. For normal BT devices, the GFSK mode is used.

    Conducted power refer ANSI C63.10:2013 Section 7.8.5 Output power test procedure for
    frequency-hopping spread-spectrum (FHSS) devices
     Radiated power refers to ANSI C63.10:2013 Section 6.6.4 Radiated emissions tests.


    Measurement parameters

                                                               Measurement parameter
                              Detector:                                                      Peak
                              Sweep Time:                                                    Auto
                              Resolution bandwidth:                                          1MHz
                              Video bandwidth:                                               3MHz
                              Trace-Mode:                                                    Max hold




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 31 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA



        Limits
                                              FCC                                                           IC
                                                           Antenna Gain
                                                               6 dBi


     Note: The antenna gain of the complete system is calculated by the difference of radiated power in
     EIRP and the conducted power of the module. For BT V3.0 devices, the GFSK mode is used;
                                                  Lowest Channel             Middle Channel            Highest Channel
              Tnom                Vnom
                                                    2402 MHz                   2441 MHz                   2480 MHz
            Conducted power [dBm]
                Measured with                             0.46                      0.87                         0.26
              GFSK modulation
             Radiated power [dBm]
                Measured with                             2.50                      2.85                         2.38
              GFSK modulation
              Gain [dBi] Calculated                       2.04                      1.98                         2.12

                        Measurement uncertainty                                 ± 1.6 dB (cond.) / ± 3.8 dB (rad.)




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 32 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN8NSKBZ04            Report No.: LCS190322010AEA



7. TEST SETUP PHOTOGRAPHS


    Please refer to separated files for Test Setup Photos of the EUT.


8. EXTERIOR PHOTOGRAPHS OF THE EUT


    Please refer to separated files for External Photos of the EUT.


9. INTERIOR PHOTOGRAPHS OF THE EUT


    Please refer to separated files for Internal Photos of the EUT.




                           ----------------THE END OF REPORT---------------




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 33 of 33



Document Created: 2019-04-17 18:41:12
Document Modified: 2019-04-17 18:41:12

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC